1 대한치주과학회지 2008;38: Resonance Frequency Analysis(RFA) 를이용한임플란트종류간의초기안정성비교 오준호, 장문택 * 전북대학교치의학전문대학원치주과학교실 Comparison of initial implant stability measured by Resonance Frequency Analysis between different implant systems Jun-ho Oh, Moontaek Chang * Department of Periodontology, School of Dentistry, Chonbuk National University ABSTRACT Purpose: The objective of this study was to compare initial implant stability measured by RFA between different implant systems during the initial healing period. Material and Methods: Fifty-four patients (36 males/18 females) who had been treated at the Department of Periodontology, Chonbuk National University Dental Hospital during the period between January and November in 2007 were included in the study. The mean age of the subjects was 49 years old (18 to 77). A total of 104 implants (Type A: 3i Osseotite, Type B: Replace select, Type C: ITI implant) were placed following the manufacturer's standard surgical protocols. Implant stability quotient (ISQ) readings were obtained for each implant at the time of surgery, 2-, and 4-month postoperatively. Result: No implant was failed during the observation period. At the baseline, the difference between mean ISQ values of 3 implant systems was statistically significant (p<0.05). However, at 2-, and 4-month following implant surgery, no significant difference was observed between ISQ values of the implant systems. In the same implant, the ISQ values of Type B and C implants increased (p<0.05), but those of Type A implants decreased during the 2-month healing period. The mean ISQ values of Type B and C implants showed a increasing tendency, while those of Type A implants were stable for the 4-month follow-up period. Conclusion: Within limits of this study, it can be concluded that implant design and surface topography of implant might influence the ISQ value and changing pattern during the initial healing period. (J Korean Acad Periodontol 2008;38: ) KEY WORDS: Resonance Frequency Analysis; dental implant; implant stability; initial healing. 서론 성공적인임플란트의주위조직에서일어나는골유착 (osseointegration) 은연조직의게재없는골과임플란트표면의직접적인구조적, 기능적결합을의미한다 1). 골유착을얻기위해처음제안된술식은 4~6 개월치유기간후임플란트에부하를가하는것이었으나, 즉시부하 (immediate Correspondence: Dr. Moontaek Chang Department of Periodontology, School of Dentistry, Chonbuk National University, Gumam-dong, Dukjin-gu, Chonju, , Korea. chang@chonbuk.ac.kr, Tel: , Fax: * 이논문은 2007 년도전북대학교병원연구비지원으로수행됨. Received: Aug 13, 2008; Accepted: Sep 11, 2008 loading) 나초기부하 (early loading) 술식역시높은예견성이있음이보고되면서 2,3,4) 초기안정성에대한중요성이부각되었다. Adell 등 1,5) 은임플란트의초기안정성이골유착의필수요건이라고하였고, 골유착의효과적예견지표로제안되었다 6,7). 또한높은초기안정성은임플란트에서좀더예견성있는즉시부하를가능하게한다 3). 임플란트의초기안정성을평가하는다양한방법이제시되었다. 임플란트상부를두드려보는 tapping test 5) 와방사선검사 8) 는안전성을평가하기에는부정확한단점이있고, 조직학적분석 9), 제거토크분석 (removal torque analysis) 10) 은침습적인문제가있기에이러한방법들은장 529

2 오준호, 장문택 대한치주과학회지 2008 년 38 권 3 호 기간연구에적합하지못하다. 이런문제점을극복하기위해 Periotest 가고안되어임플란트의골유착을평가하기위해사용되었다 11). 그러나 Periotest 값은측정방향과위치에많은영향을받기에생역학적지표 (biomechanical parameter) 로사용되기에는정확성이의심스럽다 12,13). Meredith 14) 는동물실험에서임플란트에변환기 (transducer) 를연결하고 resonance frequency(rf) 를측정하여임플란트주변골을분석하는비침습적방법을제시하였다. Implant stability quotient(isq) 로표시되는 RFA 측정값은 0~100 까지값을가지며, 높은값은안정성이높음을의미한다 14,15). RFA 측정으로임플란트의초기안정성을보고한많은연구들 7,14,15,19,21-23,26,27,29,30) 이있으나, 이들연구들은대부분한가지종류의임플란트에서초기안정성을비교분석하였으며 7,15,19,22,23,29,30), 다른형태의임플란트종류간초기안정성을비교분석한연구 19) 는드물다. 본연구의목적은 RFA 를이용하여초기골유착기간중에다른종류의임플란트시스템사이의 ISQ 의비교및변화를알아보고자한다. 재료및방법 1. 연구대상 2007 년 1월부터 11월까지전북대학교치과병원치주과에서임플란트매식수술을받은환자를대상으로하였다. 연구에포함된환자는모두 54 명 ( 남성 : 36 명, 여성 : 18 명 ) 으로평균나이는 49 세 (18~77 세 ), 이들가운데흡연자는 18 명이었다. 표면처리가다른세종류의임플란트 - Type A (Osseotite, 3i-implant Innovations, West Palm Beach, Florida, USA), Type B(Replace Select Tapered, Nobel Biocare, Göteborg, Sweden), Type C(ITI, Institut Straumann AG, Basel, Switzerland)- 가매식되었다. Type A 임플란트는산부식처리가된 Osseotite TM 표면이고 Type B 임플란트는 electrochemical process 방법을이용하여티타늄표면에자연적인산화막을입힌 TiUnite TM 표면이며다른임플란트와달리 tapered design 을가진다. Type C 임플란트는 SLA(Sandblast Large grit Acid etch) 표면을가지고 2.8 mm shoulder 가존재하여지대주 (abutment) 와의연결이치조골상방에위치하게된다. 매식된총 104 개의임플란트가운데 Type A 임플란트는 36 개, Type B는 48 개, Type C는 20 개이었으며, 임플란트의길이는 10~15 mm, 직경은 3.5~6 mm로분포되었다. 임플란트는전치부에 19개 (18.3%), 소구치부에 14개 (13.5%), 대구치부에 71개 (68.2%), 그리고상악에 49개 (47.1%), 하악에 55 개 (52.9%) 식립되었다. 일회수술법 (one-stage) 으로식립된임플란트는 58 개 (55.8%), 이회수술법으로식립된임플란트는 46 개 (44.2%) 였고 Type C 임플란트는모두일회수술법으로식립되었다. 구강내소독후 2% Hcl lidocaine(1: epinephrine 함유 )(Xylestesin-A, 3M ESPE, Seefeld, Germany) 으로수술부위를마취하고, 절개후판막을거상한다음각임플란트시스템제조사에서추천한방법으로식립하였다. 피질골이두꺼운 type I(Lekholm & Zarb classification, 1985) 에서는 bone tapping drill을사용하였다. 식립시주변에골결손부가존재한 35개 (33.7%) 임플란트주위에는자가골이나이종골 (Bio-Oss, Geistlich AG, Wollhusen, Switzerland), 또는이를혼합하여골증대술을실시하였다. 2명환자에식립된 7개임플란트는잔존골이부족하여상악동이식술후 6개월째식립하였다 ( 모두 Type B 임플란트 ). 전치부에단독즉시임플란트가식립된오직한명의환자를제외한나머지환자에서는발치후골이충분히치유된시기에식립되었다. 흡수성차폐막을사용하여골재생유도술을실시한 4명의환자에서차폐막이노출되는문제를제외하고연구기간중다른후유증은관찰되지않았다. 노출된차폐막부위는 chlorhexidine( 클로헥신, 대웅제약, 성남시, 대한민국 ) 을사용하여 4~6 주간치료후치유되었다. 2. 연구방법각임플란트에맞는 magnetic peg(smartpeg TM ) 를연결하고 Osstell TM Mentor(Integration Diagnostics AB, Göteborg, Sweden) 을이용하여협측에서 2회측정하였다. 일회법으로시술된임플란트는수술시, 2, 4개월후에 RFA 를측정하였고, 2회법으로시행된임플란트에서는수술시, 지대주연결시 ( 술후 4개월 ) 에측정하였다. 530

3 J Korean Acad Periodontol 2008;38(3) Resonance Frequency Analysis(RFA) 를이용한임플란트종류간의초기안정성비교 3. 통계분석수술시와 2개월째측정한임플란트시스템간의 ISQ 값비교는 Mann-Whitney U test, 동일임플란트에서측정된수술시, 그리고 2개월째 ISQ 값의비교는 paired t-test 를사용하였다. 결과 임플란트식립시 Type A 임플란트의평균 ISQ 값은 76.2( 범위 : 48.5~87.0), Type B의평균 ISQ 값은 72.7( 범위 : 45.0~84.0), Type C의평균 ISQ 값은 67.6( 범위 : 41.0~84.0) 으로나타났다. 세그룹의 ISQ 값은통계적으로유의한차이를보였다 (p<0.05, Fig. 1). 그러나임플란트식립후 2개월째측정한평균 ISQ 값은 Type A, B, C에서각각 76.8( 범위 : 55.5~86.0), 77.8( 범위 : 67.0~85.5), 76.4( 범위 : 64.0~82.5) 로통계적으로유의한차이를보이지않았다 (Fig. 2). 임플란트수술시와 2개월후모두측정된임플란트를대상 (Type A; 14개, Type B; 14개, Type C; 16 개 ) 으로한 ISQ 값변화를관찰하면 Type A에서는감소한반면, 나머지 Type B, C에서는증가하는경향을보였다 (Fig. 3). Type B와 Type C는 2개월관찰기간동안통계적으로유의한증가가관찰되나 (P<0.05), Type A에서의감소는통계적유의성이없었다. 4개월째 ISQ 값이조사된 36 개의임플란트 (Type A; 13개, Type B; 15개, Type C; 8개 ) 를포함하여수술시, 2, 4개월사이의 ISQ 값변화를각임플란트시스템별로관찰하였다 (Fig. 4). Type A 임플란트는관찰기간중거의변화가없었지만, Type B, C 임플란트는관찰기간중증가하는경향을보였다 Type A Type B Type C implant type Figure 1. Baseline ISQ values of 3 implant types Type A Type B Type C implant type Figure 2. 2-month ISQ values of 3 implant types * * Baseline 2-month Type A Type B Type C 40.0 Baseline 2-moth 4-moth Type A Type B Type C implant type Figure 3. Comparison of mean ISQ values between implant surgery and 2-month postoperatively in 3 implant types * Statistically significant increase compared to surgery(p<0.05) Figure 4. Change of mean ISQ values for 4-month after implant surgery in 3 implant types 531

4 오준호, 장문택 대한치주과학회지 2008 년 38 권 3 호 고찰 임플란트의즉시또는초기부하술식이예견성있는치료로보고되면서 3,4) 임플란트의초기안정성의중요성이부각되었다. 초기안정성을비침습적방법으로측정하기위하여 RFA 가개발되었다 14). 이번연구에서세임플란트시스템의수술시 ISQ 값은 Type C에서가장낮은수치가기록되었다. 이임플란트시스템은즉시또는초기부하술식에성공적으로많이사용되고있으며 16-18), 일반적으로보철치료전약 6주의치유기간을추천한다 16,23). 이번실험에서도 Type C 임플란트는골이식이필요치않은부위에모두일회수술법으로식립되었고, 대부분 3개월째보철물이장착되어 4개월째 RFA 값은측정하지못했다. Ersanli 등 19) 은세가지임플란트시스템의 RFA 비교에서본연구에포함된 Type C와동일한임플란트의초기평균 ISQ 값이다른임플란트시스템보다낮은값 ( 평균 ISQ: 상악 ; 55, 하악 ; 60) 을가짐을보고하였다. 이들의연구에서측정된 ISQ 값은이번연구에서사용한 Osstell TM Mentor (magnetic device) 의이전모델 Osstell(electronic device) 로측정되었다. 두장치의 ISQ 값을비교한연구에서 Mentor 로측정한값이 8~12 정도높은값을보였음 20) 을감안하면이번연구에서의평균 ISQ 67.6 과 Ersanli 등 19) 의측정값이유사함을알수있다. 이렇게낮은값을보이는이유는 Meredith 등 21) 이언급한치조골상부임플란트높이 (supracrestal implant height) 와 RFA 값의강한상관관계에서찾을수있다. 3 mm 의치조골상부임플란트 shoulder때문에낮은 ISQ 가측정되었으며만약이길이가보정된다면다른임플란트와유사한값을보였을것이다 22). 또다른이유로는일부임플란트 (20 개중 4개 ) 에서식립시약간의임플란트자체의골내회전 (rotation) 이존재하였기에낮은 ISQ 값을보였을수있다. 많은연구에서 2개월이내의초기 ISQ 값의변화에대해서조사되었다 19,20,23). Barewal 등 23) 은다양한골질에식립된 SLA(Sand blast large grit acid-etched) 표면처리된임플란트에서의 ISQ 값을술후 6주까지매주, 그리고 8주, 10주째측정하였다. ISQ 값은골질에상관없이 3주째가장낮은값을보였고, 4주이후부터는골질그룹간차이가없었으며, 6주이후부터는안정기 (plateau stage) 에이른다고 하였다. 이러한변화는초기골접촉 (primary bone contact) 에의한임플란트수술후초기의기계적유지가시간이지남에따라임플란트와주위골사이의교직골 (woven bone) 이층판골 (lamellar bone) 로대체되는이차적인고정과정이반영된것이라고하였다 23,24). 이는 Roberts 등 25) 의토끼실험에서골에야기된상처의치유과정에서초기 (0~6 주 ) 에가골 (callus) 이생기고, 6주째부터층판골이침착되는것과일치하는내용이다. 본연구에서수술시와 2개월후값이동시에측정된임플란트를대상으로관찰시 Type A를제외한임플란트에서 ISQ 값의증가경향이관찰되는것은이러한층판골침착에의한결과로생각될수있다. 반면초기평균 ISQ 값이높은 Type A에서는 ISQ 값이거의변화없이유지되고있었으며, 오히려통계학적으로유의하진않지만약간의감소가관찰되었다. 결과적으로 2 개월째에는임플란트시스템사이에서평균 ISQ 값의유의한차이가관찰되지않았다. 이는낮은초기 ISQ 값을보이는임플란트는시간이지나면서그값이증가하고, 높은초기 ISQ 값을보이는임플란트는시간에따라그값이감소하여결과적으로임플란트간 ISQ 값에차이가줄어드는 catch up effect 로설명될수있다 7,23,30). 수술시, 2, 4개월후각각의시기에조사된임플란트그룹간의 ISQ 평균변화값을비교하면 Type B, C 임플란트에서는그값이지속적으로증가하고, Type A 임플란트는거의변화가없음이관찰된다. 이러한시간에따른 ISQ 값의변화는임플란트의형태, 표면처리등에영향을받은것으로보인다. 이런차이는다른연구에서도관찰되는데 Oʼ Sullivan 등 26,27) 은동물실험과인체해부실험에서 tapered design 의임플란트에서높은 RFA 값이관찰됨을보고하였고, 거친표면 (rough surface) 을가진임플란트에서평활면 (machined surface) 을가진임플란트에비해높은골-임플란트접촉 (bone-implant contact) 을보임을증명하였다 28). Glauser 등 15) 은성공한임플란트와실패한임플란트의 RFA 값의변화를조사하였다. 81 개의 Brånemark 임플란트중 9개 (11.2%) 가보철수복후 1년내실패하였는데실패한임플란트는성공한임플란트와달리 1개월후현저히 RFA 값이저하하였으며, 이들결과에서 RFA 의임플란트실패예견성의효용성을언급했다. 반면 Huwiler 등 29) 은연구에포함된임플란트에서단지한개의임플란트가실패했고, 임플란트의동요가임상적으로탐지된후에 ISQ 값의갑작스러운저하가관찰되었기에 RFA 의예측능력에의문을가 532

5 J Korean Acad Periodontol 2008;38(3) Resonance Frequency Analysis(RFA) 를이용한임플란트종류간의초기안정성비교 졌으며, Nedir 등 30) 은 RFA 가임플란트동요도를재현성있게진단하지못함을보고했다. 이번연구에서관찰기간중실패한임플란트는없었으므로, RFA 가임플란트실패를예견하기위해사용될수있는효용성을파악할수는없었다. 따라서실패한임플란트를다수포함하는연구로 RFA 의진단적가치에대한평가가필요할것이다. RFA 를이용하여측정된임플란트형태와표면이다른세종류의임플란트의초기안정성을비교한본연구에서임플란트수술시에는임플란트종류간에 ISQ 값의유의한차이가존재하였지만, 술후 2, 4개월째에는통계적으로유의한차이가관찰되지않았다. 시간에따른 ISQ 값의변화는임플란트시스템별로다른형태의변화를보였다. 그러므로적절한임플란트부하시기를결정하기위하여 RFA 를사용할경우임플란트시스템별로정상적범위의 ISQ 값을설정할필요가있다. 그리고초기 ISQ 값이나변화값으로임플란트의성공여부를예측하는 RFA 의효용성에대한연구가필요할것이다. 참고문헌 1. Brånemark PI, Hanson BO, Adell R. osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconst Surg 1977;11 (Suppl 16): Albrektsson, T. & Isidor, F. Consensus report of session V. IN Lang, N-P. & Karring, T., des. Proceedings of the 1st European workshop on periodontology. London: Quintessence Publ. Co. 1994; Szmucler-Moncler S, Piattelli A, Favero GA, Dubruille JH. Consideration preliminary to the application of early and immediate loading protocols in dental implantology. Clin Oral Implants Res 2000;11: Degidi M, Piattelli A. Immediate functional and non functional loading of dental implants: a 2- to 60- month follow-up study of 646 titanium implants. J Periodontol 2003;74: Adell, R., Lekholm, Ul, Rockler, B. & Brånemark, PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. International Journal of Oral Surgery 1981;10: Meredith, N. Assessment of implant stability as a prognostic determinant. International Journal of Prosthodontics 1998;11: Friberg, B., Sennerby, L., Lin den, B., Grondahl, K. & Lekholm, U. Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency analysis study. International Journal of Oral & Maxillofacial Surgery 1999a;28: Sunden S, Grondahl K, Grondahl HG. Accuracy and precision in the radiographic diagnosis of clinical instability in Brånemark dental implants. Clin Oral Implants Res 1995;6: Albreksson, T.& Jacobsson, M. Bone-metal interface in osseointegration. Journal of Prosthetic Dentistry 1987;57: Carlsson, L., Rostlund, T., Albrektsson, B. & Albrektsson, T. Removal torques for polished and rough titanium implants. International journal of Oral and Maxillofacial Implants 1988;3: Olivé, J. & Aparicio, C. Periotest method as a measure of osseointegrated oral implant stability. International Journal of Oral and Maxillofacial Implants 1990;5: Caulier, H., Naert, I., Kalk, W. & Jansen, J.A The relationship of some histologic parameters, radiographic evaluations, and Periotest measurements of oral implants: an experimental animal study. International journal of oral and maxillofacial implants 1997;3: Derhami, Kl, Wolfaardt, J.F., Faulkner, G. & Grace M. Assessment of the periotest device in baseline mobility measurements of craniofacial implants. International journal of oral and maxillofacial implants 1995;10: Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res 1996;7: Glauser R, Sennerby L, Meredith N, et al. Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants. Clin Oral Implants Res 2004;15: Cochran DL, Buser D, tenbruggenkate C, et al. The use of reduced healing times on ITI implants with a sandblasted and acid etched surface: Early results from clinical trials on ITI SLA implants. Clin Oral Implants Res 2002;13: Buser D, Schenk R, Steinemann S, et al. Influence of surface characteristics on bone integration of titanium 533

6 오준호, 장문택 대한치주과학회지 2008 년 38 권 3 호 implants. A histometric study in miniature pigs. J Biomed Mater Res 1991;25: Romeo E, Chiapasco M, Lazza A, et al. Implant-retained mandibular overdentures with ITI implants. Clin Oral Implants Res 2002;13: Ersanli S, Karabuda C, Leblebicioglu B. Resonance frequency analysis one-stage dental implant stability during the osseointegration period. J Periodontol 2005;76; Valderrama P, Oates TW, Jones AA, et al. Evaluation of two different resonance frequency devices to detect implant stability: A clinical trial. J periodontol 2007;78: Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Implants Res 1997;8: Zix J, Kessler-Liechti G, Mericske-stern R. Stability measurements of 1-staged implants in the maxilla by means resonance frequency analysis: A pilot study. Int J Oral Maxillofac Implants 2005;20: Barewal RM, Oates TW, Meredith N, Cochran DL. Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface. Int J Oral Maxillofac Implants 2003;18: Cochran KL, Schenk R, Lussi A, Higginbottom FL, Buser D. Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: A histometric study in the canine mandible. J Biomed Mater Res 1988;40: Roberts W. Bone tissue interface. J Dent Educ 1988;52(12): OʼSullivan D, Sennerby L, Meredith N. Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants. Clin Oral Implants Res 2004;15: OʼSullivan D, Sennerby L, Meredith N. Measurements comparing the initial stability of five designs of dental implants: a human cadaver study. Clin Oral Implants Res 2000;2: Davies JE. Mechanism of endosseous integration. Int J Prosthodont 1998;11: Huwiler MA, Pjetursson BE, Bosshardt DD, Salvi GE, Lang NP. Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installation. Clin Oral Implants Res 2007;18: Nedir R, Bischof M, Szmukler-Moncler S, Bernard JP, Samson J. Predicting osseointegration by means of implant primary stability. A resonance-frequency analysis study with delayed and immediately loaded ITI SLA implants. Clin Oral Implants Res 2003;15:

00)13-3목차1~3

00)13-3목차1~3 An evaluation of marginal bone level change in single short implant : an 1-year follow up Tae-Hoon Lee, Joo-Hyun Kwon, Sunjai Kim, Chong-Hyun Han Department of Prosthodontics, Kangnam Severance hospital,

More information

임플랜트수용부형성방법이임플랜트 1차안정성에미치는영향을검사하고자시행하였다. Korea) 를사용하여 4종골질의목재판에각군당 6개씩의임플란트를각각식립하였다. Ⅱ. 연구재료및방법 1. 실험재료본연구에서사용된목재판은 Osstem사 (Osstem Co., Korea) 에서 typ

임플랜트수용부형성방법이임플랜트 1차안정성에미치는영향을검사하고자시행하였다. Korea) 를사용하여 4종골질의목재판에각군당 6개씩의임플란트를각각식립하였다. Ⅱ. 연구재료및방법 1. 실험재료본연구에서사용된목재판은 Osstem사 (Osstem Co., Korea) 에서 typ 대한치과보철학회지 :Vol. 45, No. 4, 2007 다양한골질에서임플랜트수용부형성방법이임플랜트 1 차안정성에미치는영향 전남대학교치의학전문대학원치과보철학교실, * 구강악안면외과학교실 최득철 방몽숙 오희균 * Ⅰ. 서론최근에임플랜트가상실된치아의수복방법으로보편화되면서임플랜트의생체적합성연구와함께생체기능성에대한연구가많이시행되고있다. 임플랜트가악골에식립된후정상치아와같은기능을수행하려면식립된임플랜트계면과골과의견고한유착이이루어져야한다.

More information

untitled

untitled Vol. No., June 0 수술 방법에 따른 이중 미세 나사산 임플란트의 안정도 및 주변골 변화에 관한 연구 최연조, 김명윤, 이상윤, 권민수, 권종진 고려대학교 안암병원 치과 보철과, 김명윤 치과의원, 고려대학교 임플란트 연구소, 고려대학교 안암병원 치과 구강악안면외과 Changes of stability and peri-implant bone formation

More information

대한치과이식(임프란트)학회 학회지 제 27권 1호

대한치과이식(임프란트)학회 학회지 제 27권 1호 33 부분무치악및단일치아즉시부하법에서시기에따른고정도변화 가브리엘치과김창욱 I. 서론임프란트의조기부하법에대한보고는일찍부터있어왔다 18,29). 최근에즉시 / 조기식립임프란트에대한연구들이활발해지면서하악전치부결손부에즉시 / 조기부하임프란트를하게되었고 2), 하악전치부 over denture에도즉시 / 조기부하식립이보고되었다 7). 또한상하악전치부에단일치아회복이나부분무치악부위에즉시

More information

untitled

untitled Vol. 30 No. 2, December 2011 Brånemark implant 를이용한상, 하악구치부수복시 implant 생존율및주변골흡수에대한 10 년간의추적조사 김홍석, 안재명, 팽준영, 홍종락, 김창수 성균관대학교의과대학삼성서울병원구강악안면외과 Ten years retrospective study of cumulative survival rate

More information

대한치과이식(임프란트)학회 학회지 제 27권 1호

대한치과이식(임프란트)학회 학회지 제 27권 1호 Hounsfield unit을 이용한 임프란트 식립부위의 골질 평가 조선대학교 치과대학 구강악안면외과학교실 문성용, 정미경, 김수관, 김학균 I. 서론 최근 임프란트 무치악의 재건을 위해 많이 사용되어 지고 있으며, 그 성공률은 환자의 전신적 건강 상태, 임프란트 재료의 생체 적합성, 술자의 술식, 골의 질 과 양에 따라 좌우된다 ). bone quantity"는

More information

대한치과보철학회지 :Vol. 36, No. 5, 1998 PerioTest 를이용한임플란트동요도에관한임상적연구 연세대학교치과대학치과보철학교실 김선재 한동후 Ⅰ. 서론 골유착성임플란트는 1969 년 Bra nemark 에의해보고된후많은임상적, 실험적연구를통해완전또는부분무

대한치과보철학회지 :Vol. 36, No. 5, 1998 PerioTest 를이용한임플란트동요도에관한임상적연구 연세대학교치과대학치과보철학교실 김선재 한동후 Ⅰ. 서론 골유착성임플란트는 1969 년 Bra nemark 에의해보고된후많은임상적, 실험적연구를통해완전또는부분무 대한치과보철학회지 :Vol. 36, No. 5, 1998 PerioTest 를이용한임플란트동요도에관한임상적연구 연세대학교치과대학치과보철학교실 김선재 한동후 Ⅰ. 서론 골유착성임플란트는 1969 년 Bra nemark 에의해보고된후많은임상적, 실험적연구를통해완전또는부분무치악환자에서성공적인치료법으로자리잡았다 1-5,16). 골유착이란임플란트주위골과임플란트의표면사이에서의직접적인구조적

More information

I 서론 치과용 임플란트는 Brånemark 등1의 골유착 (osseointegration) 발견 이후 끊임없는 발전 을 거듭해 왔다. Brånemark 등 1 이 밝혀낸 골 유착은 임플란트의 표면과 living bone 사이에 연조직 층 의 생성이 없이 직접 골조직이

I 서론 치과용 임플란트는 Brånemark 등1의 골유착 (osseointegration) 발견 이후 끊임없는 발전 을 거듭해 왔다. Brånemark 등 1 이 밝혀낸 골 유착은 임플란트의 표면과 living bone 사이에 연조직 층 의 생성이 없이 직접 골조직이 ISSN 1229-5418 ; 17(4): 268~274 임플란트 드릴링 시 발생하는 열과 그 원인에 대한 분석 한선희 1, 김병국 2, 김범익 2 1 서울대학교 치의학대학원 치주과학교실, 2 오스템임플란트연구소 Temperature Measurement during Implant-site Preparation Seon-Hee Han 1, Byoung Kook

More information

012임수진

012임수진 Received : 2012. 11. 27 Reviewed : 2012. 12. 10 Accepted : 2012. 12. 12 A Clinical Study on Effect of Electro-acupuncture Treatment for Low Back Pain and Radicular Pain in Patients Diagnosed with Lumbar

More information

untitled

untitled Vol. 32 No. 2, June 2013 임플란트의초기안정성에관한고찰 : 성견에서의실험적연구 김영각 1, 김성탁 2, 현기 1, 황석현 1, 김재만 1, 주총 2, 전상호 1, 최연조 3, 류재준 3, 권종진 1 1 고려대학교의과대학안암병원치과학교실구강악안면외과, 2 고려대학교의과대학임상치의학대학원, 3 고려대학교의과대학안암병원치과학교실보철과 Study

More information

7-2È£

7-2È£ original article OA A comparative study on accuracy of the implant torque devices for screw tightening Hi-Chan Jung 1, Chang-Mo Jeong 2 1 Graduate student, DDS,MSD Dept of Prosthodontic Dentistry, College

More information

- iii - - i - - ii - - iii - 국문요약 종합병원남자간호사가지각하는조직공정성 사회정체성과 조직시민행동과의관계 - iv - - v - - 1 - - 2 - - 3 - - 4 - - 5 - - 6 - - 7 - - 8 - - 9 - - 10 - - 11 - - 12 - - 13 - - 14 - α α α α - 15 - α α α α α α

More information

ORIGINAL ARTICLE 두종의 external hex implant 의변연골흡수에관한연구 : 예비연구 (preliminary study) 이지은 * 허성주* 곽재영* 김성균* 한종현** * 서울대학교치과대학보철학교실, ** 연세대학교영동세브란스치과보철과 목적 :

ORIGINAL ARTICLE 두종의 external hex implant 의변연골흡수에관한연구 : 예비연구 (preliminary study) 이지은 * 허성주* 곽재영* 김성균* 한종현** * 서울대학교치과대학보철학교실, ** 연세대학교영동세브란스치과보철과 목적 : ORIGINAL ARTICLE 두종의 external hex implant 의변연골흡수에관한연구 : 예비연구 (preliminary study) 이지은 * 허성주* 곽재영* 김성균* 한종현** * 서울대학교치과대학보철학교실, ** 연세대학교영동세브란스치과보철과 목적 : 치과임플랜트주위의변연골변화는임플랜트의기능적인유지뿐만아니라심미적성공을위해서도중요하다. 변연골의유지를위한임플랜트디자인이연구되고있다.

More information

<332E20C3D6BCBAC8A320BCB1BBFDB4D42E687770>

<332E20C3D6BCBAC8A320BCB1BBFDB4D42E687770> Original article J Korean Acad Periodontol 2009;39:311-320 조절되는당뇨환자에게식립된치과임플란트의생존율에대한후향적연구 김영희, 엄유정, 정의원, 김창성, 조규성, 최성호 * 연세대학교치과대학치주과학교실 A retrospective study of the dental implants placed in the controlled

More information

1..

1.. Volume 12, Number 1, 6~16, Factors influencing consultation time and waiting time of ambulatory patients in a tertiary teaching hospital Jee-In Hwang College of Nursing Science, Kyung Hee University :

More information

<C0D3C7C3B6F5C6AE D345FA4BDA4CBA4B8A4D328C7D0C8B8BFEB292E706466>

<C0D3C7C3B6F5C6AE D345FA4BDA4CBA4B8A4D328C7D0C8B8BFEB292E706466> Original Article 술자의숙련도에따른임플란트식립경향에관한후향적연구 이홍석 1, 이성조 1, 송영균 2, 조인우 1, 박정철 1, 신현승 1 * 1 단국대학교치과대학치주과학교실 2 단국대학교치과대학보철학교실 Research of Tendency for Implant Placement According to Experience of Operator:

More information

01)13-1목차1~3

01)13-1목차1~3 Sinus Floor Grafting with Simultaneous Implant Placement on Severe Artrophied Maxillary Ridge Jin-Hyuk Yang, Ji-Youn Hong, Ui-Won Jung, Chang-Sung Kim, Kyoo-Sung Cho, Seong-Ho Choi Department of Periodontology,

More information

Digital Abutment

Digital Abutment Digital Abutment P25 Digital Abutment Product Catalog 기성 Abutment 보다진화된, Customized Abutment 보다편리한, Digital Abutment! 절치 소구치 대구치 CEJ Cemento Enamel junction Digital Abutment 는 CEJ 를기준으로생성되어보철물의심미성이우수하며,

More information

100520_1840È£_Ä¡Àǽź¸__³»Áö.pdf

100520_1840È£_Ä¡Àǽź¸__³»Áö.pdf A gift to our Dental Artists! The New Genaration Flowable Resin 3 People 5 6 7 The 6th Congresss of the International Cleft Palate Foundation in conjunction with 14th National Congress of Korean Cleft

More information

ISSN Implantology 2014; 18(2): 140~146 디지털 3 차원영상을이용한무피판절개임플란트식립 : 증례보고 백장현 경희대학교치의학전문대학원치과보철학교실 Flapless Implant Placement with Digital Thr

ISSN Implantology 2014; 18(2): 140~146 디지털 3 차원영상을이용한무피판절개임플란트식립 : 증례보고 백장현 경희대학교치의학전문대학원치과보철학교실 Flapless Implant Placement with Digital Thr ISSN 1229-5418 Implantology 2014; 18(2): 140~146 디지털 3 차원영상을이용한무피판절개임플란트식립 : 증례보고 백장현 경희대학교치의학전문대학원치과보철학교실 Flapless Implant Placement with Digital Three-dimensional Imaging and Planning System: A Case

More information

노영남

노영남 Purpose: Delayed massive hemorrhages from pseudoaneurysm rupture of the peripancreatic large arteries, after pancreaticoduodenectomy, are fatal. We reviewed the clinical course and outcome of bleeding

More information

원위부요척골관절질환에서의초음파 유도하스테로이드주사치료의효과 - 후향적 1 년경과관찰연구 - 연세대학교대학원 의학과 남상현

원위부요척골관절질환에서의초음파 유도하스테로이드주사치료의효과 - 후향적 1 년경과관찰연구 - 연세대학교대학원 의학과 남상현 원위부요척골관절질환에서의초음파 유도하스테로이드주사치료의효과 - 후향적 1 년경과관찰연구 - 연세대학교대학원 의학과 남상현 원위부요척골관절질환에서의초음파 유도하스테로이드주사치료의효과 - 후향적 1 년경과관찰연구 - 연세대학교대학원 의학과 남상현 원위부요척골관절질환에서의초음파 유도하스테로이드주사치료의효과 - 후향적 1 년경과관찰연구 - 지도김석원교수 이논문을석사학위논문으로제출함

More information

ÀÓÇÁ¶õÆ®26-1È£1010

ÀÓÇÁ¶õÆ®26-1È£1010 16 상악동내로전위된임프란트의치험례 서울대학교치과병원구강악안면외과이상우, 송진아, 명훈, 황순정, 서병무, 최진영, 이종호, 정필훈, 김명진 Ⅰ. 서론임프란트의임상적인성공률이상당히높게보고되고있으나상악에서는하악에비해그성공률이낮다고알려져있다. 이것은상악의해부학적특성에기인하며특히상악구치부에서상악동의함기화, 낮은골밀도, 불량한골질등의존재시에더욱그러하다. 1) 상악동구치부의골소주는일반적으로골밀도가낮으며피질골은얇은경우가많다.

More information

untitled

untitled Vol. 33 No. 3, December 2014 Bio-col 테크닉을이용한상악전치부임플란트의식립증례 서정민, 박현경, 박우현, 이영빈, 윤현경 국립경찰병원통합치과전문임상의과 A case of maxillary anterior implant placement using a Bio-col technique Jeong-Min Seo, Hyun-Kyung Park,

More information

01)13-2목차1~3

01)13-2목차1~3 Complications Related to Cantilever Lengths in Implant-Supported Single Crowns He Sung Shin, Myung-rae Kim, Jae Hoon Lee *Private clinic **Graduate School of Clinical Dentistry at Ewha Womans University,

More information

ISSN Implantology 2012; 16(2): 68~73 Self Adjustable 자성어태치먼트를이용하여하악임플란트오버덴처에즉시부하를가한증례 박수정, 안수진, 이성복, 이석원경희대학교치의학전문대학원강동경희대학교병원생체재료보철학교실 Mand

ISSN Implantology 2012; 16(2): 68~73 Self Adjustable 자성어태치먼트를이용하여하악임플란트오버덴처에즉시부하를가한증례 박수정, 안수진, 이성복, 이석원경희대학교치의학전문대학원강동경희대학교병원생체재료보철학교실 Mand ISSN 1229-5418 Implantology ; 16(2): 68~73 Self Adjustable 자성어태치먼트를이용하여하악임플란트오버덴처에즉시부하를가한증례 박수정, 안수진, 이성복, 이석원경희대학교치의학전문대학원강동경희대학교병원생체재료보철학교실 Mandibular Implant-Overdenture Prosthesis Using the Self-Adjustable

More information

( )Kjhps043.hwp

( )Kjhps043.hwp Difference of Fistula Maturation Degree and Physical Property by the Types of Tube Material: An Experimental Study Sang Koo Kang, M.D. 1, Hee Chul Yu, M.D. 1,4, Woo Sung Moon, M.D. 2,4, Ju Hyoung Lee,

More information

ÀÓÇÁ¶õÆ®27_2ȸ¹«Æ÷ÇÔ

ÀÓÇÁ¶õÆ®27_2ȸ¹«Æ÷ÇÔ 31 SCA(sinus crestal approach) kit 를이용한새로운상악동거상술 : 증례보고 베스필치과의원조종만 I. 서론상악구치부에서임프란트수술의가장중요한성공요소중하나는식립직후의우수한초기고정이다. 그러나상악구치부는 sinus의존재와부족한골량, 약한골질등으로충분한초기고정을얻기가어렵다. 상악구치부에서임프란트수술시고려해야할중요한두가지요소는첫째, 상악동막을손상없이효과적으로거상하는문제이며둘째,

More information

기관고유연구사업결과보고

기관고유연구사업결과보고 기관고유연구사업결과보고 작성요령 2001 ~ 2004 2005 ~ 2007 2008 ~ 2010 2001 ~ 2004 2005 ~ 2007 2008 ~ 2010 1 2/3 2 1 0 2 3 52 0 31 83 12 6 3 21 593 404 304 1,301 4 3 1 8 159 191 116 466 6 11 (`1: (1: 16 33 44 106

More information

ISSN Implantology 2014; 18(2): 86~93 경구용 Bisphosphonates 투여가임플란트변연골변화에미치는영향에관한연구 남기욱, 홍종락 성균관대학교의과대학삼성서울병원구강악안면외과 Effect of Oral Bisphosphon

ISSN Implantology 2014; 18(2): 86~93 경구용 Bisphosphonates 투여가임플란트변연골변화에미치는영향에관한연구 남기욱, 홍종락 성균관대학교의과대학삼성서울병원구강악안면외과 Effect of Oral Bisphosphon ISSN 1229-5418 Implantology 2014; 18(2): 86~93 경구용 Bisphosphonates 투여가임플란트변연골변화에미치는영향에관한연구 남기욱, 홍종락 성균관대학교의과대학삼성서울병원구강악안면외과 Effect of Oral Bisphosphonates on the Marginal Bone Loss of Dental Implant Ki-Uk

More information

저작자표시 2.0 대한민국 이용자는아래의조건을따르는경우에한하여자유롭게 이저작물을복제, 배포, 전송, 전시, 공연및방송할수있습니다. 이차적저작물을작성할수있습니다. 이저작물을영리목적으로이용할수있습니다. 다음과같은조건을따라야합니다 : 저작자표시. 귀하는원저작자를표시하여야합니

저작자표시 2.0 대한민국 이용자는아래의조건을따르는경우에한하여자유롭게 이저작물을복제, 배포, 전송, 전시, 공연및방송할수있습니다. 이차적저작물을작성할수있습니다. 이저작물을영리목적으로이용할수있습니다. 다음과같은조건을따라야합니다 : 저작자표시. 귀하는원저작자를표시하여야합니 저작자표시 2.0 대한민국 이용자는아래의조건을따르는경우에한하여자유롭게 이저작물을복제, 배포, 전송, 전시, 공연및방송할수있습니다. 이차적저작물을작성할수있습니다. 이저작물을영리목적으로이용할수있습니다. 다음과같은조건을따라야합니다 : 저작자표시. 귀하는원저작자를표시하여야합니다. 귀하는, 이저작물의재이용이나배포의경우, 이저작물에적용된이용허락조건을명확하게나타내어야합니다.

More information

(Exposure) Exposure (Exposure Assesment) EMF Unknown to mechanism Health Effect (Effect) Unknown to mechanism Behavior pattern (Micro- Environment) Re

(Exposure) Exposure (Exposure Assesment) EMF Unknown to mechanism Health Effect (Effect) Unknown to mechanism Behavior pattern (Micro- Environment) Re EMF Health Effect 2003 10 20 21-29 2-10 - - ( ) area spot measurement - - 1 (Exposure) Exposure (Exposure Assesment) EMF Unknown to mechanism Health Effect (Effect) Unknown to mechanism Behavior pattern

More information

( )Jkstro011.hwp

( )Jkstro011.hwp 비인강암의방사선치료결과및생존율에관한예후인자분석 2005 2 1 2005 3 28. :, Tel: 053)250-7665, Fax: 053)250-7984 E-mail: jhkim@dsmc.or.kr 정영연외 2 인 : 비인강암의예후인자분석 정영연외 2 인 : 비인강암의예후인자분석 Carcinoma of the nasopharynx treated by radiotherapy

More information

<38B1C731C8A320C3D6C1BE2D2D E687770>

<38B1C731C8A320C3D6C1BE2D2D E687770> 상악동거상술부위에식립한임플란트의실패후골유도재생술을통한치조제재건과재식립 : 증례보고 강주현, 차재국, 이중석, 정의원, 최성호 연세대학교치과대학치주과학교실, 치주조직재생연구소 Implant replacement and GBR for the treatment of failed implants on augmented sinus area: A case report

More information

김범수

김범수 Analysis of Outcomes after Resection of Sarcomatous Hepatocellular Carcinoma Purpose: Sarcomatous hepatocellular carcinoma (HCC) is rare. Therefore, the clinicopathologic characteristics and prognosis

More information

12-3전체

12-3전체 The histologic study of the effect of enamel matrix protein and -tricalcium phosphate in gap defect model in dogs : pilot study Lim Hyun-Chang 1, Yang Jin-Hyuk 1, Chae Gyoung-Joon 1, Kim Sung-Tae 1, Jung

More information

untitled

untitled Vol. 31 No. 3, December 2012 근단부의국소적골절단술을동반한변형된치조제분할술 : 증례보고 송찬종, 김홍순, 설동주, 이백수, 최병준, 오주영 경희대학교치의학전문대학원구강악안면외과학교실 A modified alveolar ridge splitting technique with apical osteotomy: a case report Chan-Jong

More information

_

_ 대한치과이식 ( 임프란트 ) 학회지 2011;30(1):79-84 79 완전무치악환자에서골유도재생술을통한치조골재건및다수의임프란트식립 : 증례보고 원광대학교산본치과병원구강악안면외과학교실온병훈, 박슬지, 지영덕 Ⅰ. 서론 Ⅱ. 증례보고 완전무치악환자에서임프란트식립을통한보철수복은수직적-수평적으로위축된치조제와구강점막의탄력저하로인해매우어렵다. 심하게위축된치조골에서다수의임프란트식립이계획된경우광범위한치조골의결손부를재건하기위해

More information

- i - - ii - - iii - - iv - - v - - vi - - 1 - - 2 - - 3 - 1) 통계청고시제 2010-150 호 (2010.7.6 개정, 2011.1.1 시행 ) - 4 - 요양급여의적용기준및방법에관한세부사항에따른골밀도검사기준 (2007 년 11 월 1 일시행 ) - 5 - - 6 - - 7 - - 8 - - 9 - - 10 -

More information

<283732372D3733312920B4D9C3CAC1A120BCD2C7C1C6AEC4DCC5C3C6AEB7BBC1EEC0C720B3EBBEC8C0C720BDC3B7C2BAB8C1A4BFA120B4EBC7D120C0AFBFEBBCBA20C6F2B0A1283035292E687770>

<283732372D3733312920B4D9C3CAC1A120BCD2C7C1C6AEC4DCC5C3C6AEB7BBC1EEC0C720B3EBBEC8C0C720BDC3B7C2BAB8C1A4BFA120B4EBC7D120C0AFBFEBBCBA20C6F2B0A1283035292E687770> 대한안과학회지 제 49 권 제 5 호 2008 J Korean Ophthalmol Soc 49(5):727-731, 2008 DOI : 10.3341/jkos.2008.49.5.727 다초점 소프트콘택트렌즈의 노안의 시력보정에 대한 유용성 평가 김현경 1 김효명 2 정성근 1 가톨릭대학교 의과대학 성모병원 안과학교실 1, 고려대학교 의과대학 안암병원 안과학교실

More information

- 대한치과보철학회지 Vol. 32 No. 3, 1994 - 치근형골내임플란트의초기 1 년간치조골소실및골밀도변화에관한연구 연세대학교치과대학보철학교실 정영철ㆍ한종현ㆍ이근우 I. 서론 Brånemark에의한골유착개념의임플란트가임상적으로널리적용된이래임플란트의성공과실패및그예후의판단을위한평가기준을두고많은연구가있어왔다. 처음으로골유착성임플란트이평가를제3자적입장에서시도한것은

More information

01)13-2목차1~3

01)13-2목차1~3 Guided bone regeneration on a single tooth with horizontal and vertical bone loss Ji-Eun Song, Ji-Youn Hong, Chang-Sung Kim, Kyoo-Sung Cho, Chong-Kwan Kim, Seong-Ho Choi Department of Periodontology, Research

More information

서론 34 2

서론 34 2 34 2 Journal of the Korean Society of Health Information and Health Statistics Volume 34, Number 2, 2009, pp. 165 176 165 진은희 A Study on Health related Action Rates of Dietary Guidelines and Pattern of

More information

- 대한치과보철학회지 Vol. 35 No. 4, 1997 - 보철물조건에따른 Periotest 수치의실험적평가 이화대학교의과대학치과학교실보철과 한중석 Ⅰ. 서론 임플랜트를이용한구강수복의전제조건으로매식된임플랜트의몸체와골사이에 osseointegration 이라는안정된조건이형성되어상부에서가해지는기능력이보철물을통하여하부의임프랜트몸체및주변골에전달될때, 그경계면에서유지될수있어야한다

More information

한국성인에서초기황반변성질환과 연관된위험요인연구

한국성인에서초기황반변성질환과 연관된위험요인연구 한국성인에서초기황반변성질환과 연관된위험요인연구 한국성인에서초기황반변성질환과 연관된위험요인연구 - - i - - i - - ii - - iii - - iv - χ - v - - vi - - 1 - - 2 - - 3 - - 4 - 그림 1. 연구대상자선정도표 - 5 - - 6 - - 7 - - 8 - 그림 2. 연구의틀 χ - 9 - - 10 - - 11 -

More information

Lumbar spine

Lumbar spine Lumbar spine CT 32 111 DOI : 10.3831/KPI.2010.13.2.111 Lumbar Spine CT 32 Received : 10. 05. 23 Revised : 10. 06. 04 Accepted : 10. 06. 11 Key Words: Disc herniation, CT scan, Clinical analysis The Clinical

More information

<31312EB1E8C1F6BCB128C0CFBBEABAB4BFF8292E687770>

<31312EB1E8C1F6BCB128C0CFBBEABAB4BFF8292E687770> 대한치주과학회지 : Vol. 37, No. 2, 2007 상악동골이식술을동반한임플란트식립시골이식재의높이변화에대한방사선학적평가 김지선 1,2, 이서경 1,2, 채경준 2, 정의원 2, 김창성 2, 최성호 2, 조규성 2, 채중규 2, 김종관 2, 방은경 3* 1. 국민건강보험공단일산병원치주과 2. 연세대학교치주과학교실, 치주조직재생연구소 3. 이화여자대학교의과대학치과학교실치주과

More information

975_983 특집-한규철, 정원호

975_983 특집-한규철, 정원호 Focused Issue of This Month Gyu Cheol an, MD Department of Otolaryngology ead & Neck Surgery, Gachon University of College Medicine E - mail : han@gilhospital.com Won-o Jung, MD Department of Otolaryngology

More information

DBPIA-NURIMEDIA

DBPIA-NURIMEDIA The e-business Studies Volume 17, Number 4, August, 30, 2016:319~332 Received: 2016/07/28, Accepted: 2016/08/28 Revised: 2016/08/27, Published: 2016/08/30 [ABSTRACT] This paper examined what determina

More information

I 서론 임플란트 fixture body design은크게 straight and tapered type으로구분되고있으며술자의선호도및임상적상황에따라선택되고있다. 최근에는식립의용이성, 우수한초기고정, 발치와즉시식립시장점등으로인해 tapered body implant의사용

I 서론 임플란트 fixture body design은크게 straight and tapered type으로구분되고있으며술자의선호도및임상적상황에따라선택되고있다. 최근에는식립의용이성, 우수한초기고정, 발치와즉시식립시장점등으로인해 tapered body implant의사용 ISSN 229-548 Implantology 26; 2(): 2~2 Hiossen 임플란트에대한술자의주관적만족도및단기간임상평가 윤필영, 조용석 2, 김영균 분당서울대학교병원치과구강악안면외과, 2 앞선치과병원구강악안면외과 Subjective Satisfaction of Clinician and Short-term Clinical Evaluation of Hiossen

More information

<382E20B1E8BFEBB0C72E687770>

<382E20B1E8BFEBB0C72E687770> 대한치주과학회지 : Vol. 36, No. 4, 2006 덮개나사조기노출이임플란트의생존율에미치는영향 김용건, 이재관, 장범석, 엄흥식 * 강릉대학교치과대학치주과학교실 I. 서론 치아의결손부를수복하는방법중하나인임플란트치료법은오랜기간동안성공적인결과를보여왔다 1-4). 임플란트수술법은 1회법과 2회법으로나눌수있는데, 이중 2회법에의해식립된임플란트는점막에의해덮히게되며

More information

ISSN Implantology 2013; 17(1): 12~22 심한치조골흡수에서티타늄메쉬를이용한치조골재건에대한증례 이규안, 김민수, 이중석, 정의원, 김창성, 조규성, 채중규, 최성호 연세대학교치과대학치주과학교실, 치주조직재생연구소 Ridge Au

ISSN Implantology 2013; 17(1): 12~22 심한치조골흡수에서티타늄메쉬를이용한치조골재건에대한증례 이규안, 김민수, 이중석, 정의원, 김창성, 조규성, 채중규, 최성호 연세대학교치과대학치주과학교실, 치주조직재생연구소 Ridge Au ISSN 1229-5418 Implantology 2013; 17(1): 12~22 심한치조골흡수에서티타늄메쉬를이용한치조골재건에대한증례 이규안, 김민수, 이중석, 정의원, 김창성, 조규성, 채중규, 최성호 연세대학교치과대학치주과학교실, 치주조직재생연구소 Ridge Augmentation Using Titanium Mesh in Severe Alveolar Bone

More information

ISSN eissn Case Report Implant placement simultaneously sinus augmentation using crest

ISSN eissn Case Report Implant placement simultaneously sinus augmentation using crest https://doi.org/10.14368/jdras.2017.33.1.47 ISSN 2384-4353 eissn 2384-4272 Case Report Implant placement simultaneously sinus augmentation using crestal approach in severely atrophic maxilla; minimally

More information

2015년 11월-대한악안면레이저치의학회지-청해판.hwp

2015년 11월-대한악안면레이저치의학회지-청해판.hwp 다양한 Laser 를이용한 Peri-Implantitis 의치료 The treatment of peri-implantitis using various types of lasers 유재식 1), 김수관 1), 안종모 2) 조선대학교치의학전문대학원구강악안면외과학교실 1), 조선대학교치의학전문대학원구강내과학교실 2), 대한레이저치의학회장 2) Jae-Seek You

More information

jkape hwp

jkape hwp 대한치주과학회지 : Vol. 37, No. 3, 2007 상악전치부에서단일치아발거후즉시임플란트식립 이승훈 *, 김영성, 김원경, 이영규 서울아산병원치주과 I. 연구배경 1999 년 3rd European workshop 에서임플란트의식립방식을발치후식립시기에따라 immediate, delayed, late placement 로구분하였고, immediate placement는발치즉시,

More information

<372E20B9DABFB5BBF32E687770>

<372E20B9DABFB5BBF32E687770> 대한치주과학회지 : Vol. 37, No. 2(Suppl.), 2007 New maxillary anterior ridge classification according to ideal implant restorative position determined by CAT Young-Sang Park 1, Sang-Choon Cho 2, Kyoung-Nam Kim

More information

다른 외형 및 구조를 지닌 3종류의 임플랜트를 식립 하여 보철 수복한 경우를 연구 모델로 하였다. 3종류 의 임플랜트는 Bra nemark system(nobel Biocare, Gothenberg, Sweden), Camlog system(altatec, Wurmbe

다른 외형 및 구조를 지닌 3종류의 임플랜트를 식립 하여 보철 수복한 경우를 연구 모델로 하였다. 3종류 의 임플랜트는 Bra nemark system(nobel Biocare, Gothenberg, Sweden), Camlog system(altatec, Wurmbe 대한치과보철학회지:Vol. 44, No. 2, 2006 수종의 임플랜트 시스템에 따른 유한요소법적 응력분석에 관한 연구 한양대학교 의과대학 치과학교실 유성현 박원희 박주진 이영수 Ⅰ. 서 론 임플랜트 지지 보철물의 임상적 효용성이 증가함 에 따라 현재 다양한 치과 보철 치료에 이용되고 있 다. 1,2) 그러나 임플랜트 보철물이 구강내에서 장기간 성공적인 기능을

More information

Abstract Background : Most hospitalized children will experience physical pain as well as psychological distress. Painful procedure can increase anxie

Abstract Background : Most hospitalized children will experience physical pain as well as psychological distress. Painful procedure can increase anxie Volume 12, Number 1, 92~102, An Intervention Study of Pain Reduction during IV Therapy in Hospitalized Children Myo-Jin Kim 1), Joung-Hae Bak 1), Won-Seok Seo 2) Mi-Young Kim 3), Sun-Kyoung Park 3), Jai-Soung

More information

- i - - ii - - iii - - iv - - v - - 1 - - 2 - - 3 - - 4 - - 5 - - 6 - - 7 - - 8 - - 9 - - 10 - - 11 - - 12 - - 13 - - 14 - - 15 - - 16 - - 17 - - 18 - - 19 - α α - 20 - α α α α α α - 21 - - 22 - - 23 -

More information

ÀÓÇÁ¶õÆ®27_2ȸ¹«Æ÷ÇÔ

ÀÓÇÁ¶õÆ®27_2ȸ¹«Æ÷ÇÔ 1 수평이동 골신장술을 이용한 치조골 재건술 - 증례보고 *원광대학교 치과대학 구강악안면외과학교실 **서울대학교 치과대학 구강악안면외과학교실 *팽준영, **김명진 I. 서론 임프란트의 시술이 보편화되고 많은 임상적 결과들이 보고되면서, 임프란트의 장기적인 성공을 위해서는 식립되는 치조골이 이상적인 보철물의 위치에 충분한 골질과 양을 가지고 있어야 한다는 기본적인

More information

???? 1

???? 1 The Korean Journal of Applied Statistics (2014) 27(1), 13 20 DOI: http://dx.doi.org/10.5351/kjas.2014.27.1.013 Maximum Tolerated Dose Estimation by Stopping Rule and SM3 Design in a Phase I Clinical Trial

More information

<B3EDB9AEC1FD5F3235C1FD2E687770>

<B3EDB9AEC1FD5F3235C1FD2E687770> 오용록의 작품세계 윤 혜 진 1) * 이 논문은 생전( 生 前 )에 학자로 주로 활동하였던 오용록(1955~2012)이 작곡한 작품들을 살펴보고 그의 작품세계를 파악하고자 하는 것이다. 한국음악이론이 원 래 작곡과 이론을 포함하였던 초기 작곡이론전공의 형태를 염두에 둔다면 그의 연 구에서 기존연구의 방법론을 넘어서 창의적인 분석 개념과 체계를 적용하려는

More information

ÇÐȸÁö-2005-µ¹¸°°Ü

ÇÐȸÁö-2005-µ¹¸°°Ü 40 발치후치유과정과즉시식립에대한문헌고찰 부산위드치과우중혁 GBR술식을동반한발치후즉시식립 1989 Lazzara, 1990 Becker&Becker, 1990 Nymann등은발치후 machined surface 임프란트를 submerged 시키고비흡수성 membrane으로피개한후연조직으로일차봉합하였다.(1,2,3) suppuration이나 large periapical

More information

I 서론 1969 년 Brånemark 이완전무치악 환자에서임플란트를이용한 수복치료를소개한이래 1 임플 란트를이용한자연치의회복은수복치과에서가장많은진보를이룬영역이며, 다양한임상결과를다룬다수의논문에서높은임플란트생존율과성공률을제시하고있다 2,3. 성공적인임플란트는기능뿐아니라

I 서론 1969 년 Brånemark 이완전무치악 환자에서임플란트를이용한 수복치료를소개한이래 1 임플 란트를이용한자연치의회복은수복치과에서가장많은진보를이룬영역이며, 다양한임상결과를다룬다수의논문에서높은임플란트생존율과성공률을제시하고있다 2,3. 성공적인임플란트는기능뿐아니라 ISSN 1229-5418 Implantology 2012; 16(2): 48~59 임플란트즉시식립과조기식립에의한상악전치부의심미적수복증례 황지완, 김재신, 이중석, 정의원, 김창성, 조규성, 채중규, 최성호 연세대학교치과대학치주과학교실, 치주조직재생연구소 Establishment of Esthetics in Maxillary Anterior Region Using

More information

untitled

untitled Vol. 35 No. 2, September 2016 완전무치악환자임플란트치료에대한장기예후평가 : 3 가지유형의치료법 손동환, 김영균 분당서울대학교병원치과구강악안면외과 Retrospective evaluation of implant treatment in complete edentulous patients: 3 types of prosthetic treatment

More information

ORIGINAL ARTICLE 상악피개의치를위한임플랜트의위치에따른응력분포에대한유한요소분석 하헌석 김창회 임영준 김명주서울대학교대학원치의학과치과보철학교실 임플랜트고정체의표면처리기술의발달에기인하여골유착의성공률이좋아지고있으며임플랜트를이용하는보철물의형태와임상술식도다양하게발전되

ORIGINAL ARTICLE 상악피개의치를위한임플랜트의위치에따른응력분포에대한유한요소분석 하헌석 김창회 임영준 김명주서울대학교대학원치의학과치과보철학교실 임플랜트고정체의표면처리기술의발달에기인하여골유착의성공률이좋아지고있으며임플랜트를이용하는보철물의형태와임상술식도다양하게발전되 ORIGINAL ARTICLE 하헌석 김창회 임영준 김명주서울대학교대학원치의학과치과보철학교실 임플랜트고정체의표면처리기술의발달에기인하여골유착의성공률이좋아지고있으며임플랜트를이용하는보철물의형태와임상술식도다양하게발전되고있다. 상악의임플랜트피개의치는아직표준화된치료법에대한의견이분분하다. 본연구는상악무치악의치료를위하여해부학적인요소와생역학적인요소를고려하여양측견치부또는소구치부위에

More information

Journal of Educational Innovation Research 2017, Vol. 27, No. 2, pp DOI: : Researc

Journal of Educational Innovation Research 2017, Vol. 27, No. 2, pp DOI:   : Researc Journal of Educational Innovation Research 2017, Vol. 27, No. 2, pp.251-273 DOI: http://dx.doi.org/10.21024/pnuedi.27.2.201706.251 : 1997 2005 Research Trend Analysis on the Korean Alternative Education

More information

스포츠과학 143호 내지.indd

스포츠과학 143호 내지.indd https simtk.org,, sanghyuk0620@kspo.or.kr.... 48 SPORT SCIENCE . 33 55% 1 2 Iwamoto and Takeda 2003 3 1 3.......?... 4 SPORT SCIENCE 1. 2 3 12 16 3 6.. 5 strain gauge. 1970. 6 1) Brukner, P., Bradshaw,

More information

09È«¼®¿µ 5~152s

09È«¼®¿µ5~152s Korean Journal of Remote Sensing, Vol.23, No.2, 2007, pp.45~52 Measurement of Backscattering Coefficients of Rice Canopy Using a Ground Polarimetric Scatterometer System Suk-Young Hong*, Jin-Young Hong**,

More information

고있다. Hermann 등 4 은임플랜트고정체주위변연골흡수에대해조직학적, 방사선학적인분석을하였는데 1- piece 임플랜트의경우변연골의흡수정도는거친면과평활면의경계에의해결정되며 2-piece 임플랜트의경우 microgap 이변연골가까이있을경우에 microgap 의수직적위

고있다. Hermann 등 4 은임플랜트고정체주위변연골흡수에대해조직학적, 방사선학적인분석을하였는데 1- piece 임플랜트의경우변연골의흡수정도는거친면과평활면의경계에의해결정되며 2-piece 임플랜트의경우 microgap 이변연골가까이있을경우에 microgap 의수직적위 ORIGINAL ARTICLE 김지환 정문규 문홍석 한동후연세대학교치과대학치과보철학교실 임플랜트주위변연골의흡수는임플랜트의기능적및심미적성공에큰장애가되는요인이다. Adell 은임플랜트에지대주연결후첫 1 년간평균적으로 1.5 mm의변연골소실을보이고, 이후에는매년 0.1 mm이하의변연골흡수가있었다고하였다 (Adell et al.,1981). 이러한변연골흡수를막기위한많은노력들이행해져왔다.

More information

歯제7권1호(최종편집).PDF

歯제7권1호(최종편집).PDF ********* (*, **, *** ).., 2002, 7, 1, 1-12. 2-5 80.,.,..,,... :,,. (naming).., (word finding), (lexical look- up), (lexical retrieval), (word recall) (Fried- Oken, 1987). (pause),,, (naming error) (Snyder

More information

대한구강악안면방사선학회지 2005; 35 : 63-8 성공적인임플란트시술을위한방사선검사 서울대학교치과대학구강악안면방사선학교실, 치학연구소및 BK 21 이삼선 최순철 Radiographic examination for successful dental implant Sam

대한구강악안면방사선학회지 2005; 35 : 63-8 성공적인임플란트시술을위한방사선검사 서울대학교치과대학구강악안면방사선학교실, 치학연구소및 BK 21 이삼선 최순철 Radiographic examination for successful dental implant Sam 대한구강악안면방사선학회지 2005; 35 : 63-8 서울대학교치과대학구강악안면방사선학교실, 치학연구소및 BK 21 이삼선 최순철 Radiographic examination for successful dental implant Sam-Sun Lee, Soon-Chul Choi Department of Oral and Maxillofacial Radiology,

More information

황지웅

황지웅 Comparison of Laparoscopy and Exploration in the Distal Pancreatectomy BACKGROUND: To determine the benefits of laparoscopic surgery compared with exploration, the clinical outcomes of open and laparoscopic

More information

untitled

untitled Vol. 31 No. 1, March 2012 치조골이심하게흡수된환자의수복 : Mini-implant 를이용한증례보고 이양진, 김영균 1 분당서울대학교병원치과보철과, 1 구강악안면외과 Rehabilitation of the severely atrophied edentulous patient: a case report using mini-implants Yang-Jin

More information

( ) Jkra076.hwp

( ) Jkra076.hwp Vol. 11, No. 4, December, 2004 Objective: Ultrasonography (USG) of joints has a unique position for the diagnosis of joint diseases. Bone surface, cartilage, periarticular soft tissue and their pathologic

More information

γ

γ 경락경혈학회지 Vol.27, No.1, pp.87 106, 2010 Journal of Meridian & Acupoint Dept. of 1 Meridian & Acupoint, 3 Acupuncture & Moxibustion, College of Oriental Medicine, Daejeon University 2 Division of Clinical

More information

THE JOURNAL OF KOREAN INSTITUTE OF ELECTROMAGNETIC ENGINEERING AND SCIENCE. vol. 29, no. 10, Oct ,,. 0.5 %.., cm mm FR4 (ε r =4.4)

THE JOURNAL OF KOREAN INSTITUTE OF ELECTROMAGNETIC ENGINEERING AND SCIENCE. vol. 29, no. 10, Oct ,,. 0.5 %.., cm mm FR4 (ε r =4.4) THE JOURNAL OF KOREAN INSTITUTE OF ELECTROMAGNETIC ENGINEERING AND SCIENCE. 2018 Oct.; 29(10), 799 804. http://dx.doi.org/10.5515/kjkiees.2018.29.10.799 ISSN 1226-3133 (Print) ISSN 2288-226X (Online) Method

More information

ORIGINAL ARTICLE Locator attachment 를이용한하악임플란트유지형피개의치의임상적평가 이주형 손동석 * 대구가톨릭대학교병원치과 연구목적 : 현대의학의발달로평균수명이증가

ORIGINAL ARTICLE   Locator attachment 를이용한하악임플란트유지형피개의치의임상적평가 이주형 손동석 * 대구가톨릭대학교병원치과 연구목적 : 현대의학의발달로평균수명이증가 ORIGINAL ARTICLE http://dx.doi.org/10.4047/jkap.2011.49.4.283 이주형 손동석 * 대구가톨릭대학교병원치과 연구목적 : 현대의학의발달로평균수명이증가하고고령의환자가늘어남에따라무치악환자의비율도증가하고있다. 특히심하게흡수된하악골에선기존의총의치로는환자가사용하기에유지, 지지의부족으로사용상에어려움이있다. 하악에 2 개의임플란트식립하여피개의치를제작하면환자에게좀더사용하기가편한의치를제작해줄수있다.

More information

식립위치별 임플란트 A

식립위치별 임플란트 A 목차 1 임플란트의재료 2 임플란트의치료기간 3 임플란트의부작용 4 식립위치별임플란트의종류 5 다양한임플란트의구조물 학습목표 1. 임플란트의재료의특성에대해알수있다. 2. 임플란트의치료기간을알수있다. 3. 임플란트의부작용에대해알수있다. 4. 다양한임플란트의구조물에대해설명할수있다. 최근임플란트관련기사 DENTAL IMPLANT STORY 최근임플란트관련기사 최근임플란트관련기사

More information

25È£1(¼ø)

25È£1(¼ø) 20 동종골 SureFuse TM 를이용한골결손부의치험례 * 한스바이오메드, ** 가톨릭대학교대전성모병원구강외과, # 청주다인치과보철과, *** 을지대학교정형외과, 서석진 *, 김진 **, 임헌송 #, 이광원 ***, 김수용 *, 김태운 *, 송석범 *, 김진영 *, 안재형 *, 채지화 *, 황호찬 *, 강계원 * I. 서론동종골은사람의사체에서얻어지는이식재로서공신력이있는조직은행에서획득되어관리되며엄격한공정과정을거쳐공급되어지고있다.

More information

590호(01-11)

590호(01-11) T H E K O R E A N D O C T O R S W E E K L Y www.docdocdoc.co.kr I N S I D E 38 3 5 6 7 10 13 28 29 30 31 38 41 42 2 Advertisement Government & Medicine 3 Government & Medicine 4 Government & Medicine Government

More information

ORIGINAL ARTICLE DOI: /jkap 무피판임플란트수술에서연조직펀치의크기가임플란트주위조직의치유에미치는영향 이두형 1 정승미 2 * 최병호 3 연세대학교원주의과대학치과보철과, 1 대학원생, 2 부교수, 3 연세대학교치과대학

ORIGINAL ARTICLE DOI: /jkap 무피판임플란트수술에서연조직펀치의크기가임플란트주위조직의치유에미치는영향 이두형 1 정승미 2 * 최병호 3 연세대학교원주의과대학치과보철과, 1 대학원생, 2 부교수, 3 연세대학교치과대학 ORIGINAL ARTICLE DOI:10.4047/jkap.2009.47.3.301 이두형 1 정승미 2 * 최병호 3 연세대학교원주의과대학치과보철과, 1 대학원생, 2 부교수, 3 연세대학교치과대학구강악안면외과교수 연구목적 : 연조직펀치를이용한무피판임플란트수술법은임플란트를식립할부위에환상형의절개를필요로한다. 이에연조직펀치의사용을위한지침을만드는데도움을주고자성견의하악에서임플란트주위조직의치유에대한연조직펀치의영향을조사하는실험이수행되었다.

More information

상악측절치(dh)

상악측절치(dh) J Korean Academy of Advanced General Dentistry 2014;3:29-33 ABSTRACT Endodontic Treatment of 2 Maxillary Lateral Incisors with Dens Invaginatus; 2 Case Reports Jaemin Lee, Kee-Deog Kim, Bock-Young Jung,

More information

untitled

untitled Vol. 31 No. 2, June 2012 단근치및다근치의발치후즉시식립임플란트에서이식골의입자크기에따른골형성능의비교 최연조, 신승혁 1, 염지훈 2, 황석현 2, 민유선, 이상윤, 현기 2, 권민수 3, 권종진 2 고려대학교안암병원치과보철과, 1 강남케이탑치과, 2 고려대학교안암병원치과구강악안면외과, 3 고려대학교임플란트연구소 Comparison of the

More information

433대지05박창용

433대지05박창용 Recent Changes in Summer Precipitation Characteristics over South Korea Changyong Park* JaYeon Moon** Eun-Jeong Cha*** Won-Tae Yun**** Youngeun Choi***** 1958 2007 6 9 6 9 10 10 10 10 10 Abstract This

More information

16(1)-3(국문)(p.40-45).fm

16(1)-3(국문)(p.40-45).fm w wz 16«1y Kor. J. Clin. Pharm., Vol. 16, No. 1. 2006 x w$btf3fqpsu'psn û w m w Department of Statistics, Chonnam National University Eunsik Park College of Natural Sciences, Chonnam National University

More information

°í¼®ÁÖ Ãâ·Â

°í¼®ÁÖ Ãâ·Â Performance Optimization of SCTP in Wireless Internet Environments The existing works on Stream Control Transmission Protocol (SCTP) was focused on the fixed network environment. However, the number of

More information

KAOMI 21-1_명단.hwp

KAOMI 21-1_명단.hwp 임플란트고정성보철물수복을위한최소교합고경에대한고찰 김승민 1, 최순호 1, 송영우 1, 강주현 1, 차재국 1, 이중석 1, 박영범 2, 정의원 1 * 1 연세대학교치과대학병원, 치주과학교실, 치주조직재생연구소 2 연세대학교치과대학병원, 보철과학교실 Consideration of Minimal Interocclusal Distance for Implant-supported

More information

ISSN Implantology 2015; 19(1): 16~25 1-ethyl-3-(3-dimethyl aminopropyl) Carbodiimide 로가교화된제 1 형콜라겐차폐막의골유도재생효과 : 증례보고 이재홍, 유훈, 김유경, 신현기, 임현창,

ISSN Implantology 2015; 19(1): 16~25 1-ethyl-3-(3-dimethyl aminopropyl) Carbodiimide 로가교화된제 1 형콜라겐차폐막의골유도재생효과 : 증례보고 이재홍, 유훈, 김유경, 신현기, 임현창, ISSN 1229-5418 Implantology 2015; 19(1): 16~25 1-ethyl-3-(3-dimethyl aminopropyl) Carbodiimide 로가교화된제 1 형콜라겐차폐막의골유도재생효과 : 증례보고 이재홍, 유훈, 김유경, 신현기, 임현창, 김영택, 이중석, 정의원, 최성호 연세대학교치과대학치주과학교실, 치주조직재생연구소 Guided

More information

04-다시_고속철도61~80p

04-다시_고속철도61~80p Approach for Value Improvement to Increase High-speed Railway Speed An effective way to develop a highly competitive system is to create a new market place that can create new values. Creating tools and

More information

Rheu-suppl hwp

Rheu-suppl hwp Objective: This paper reviews the existing Korean medical and public health, and nursing academy articles on disease-specific and domain-specific quality of life, and provides recommendations for the universally

More information

A Study on the Relationships between Self-Differentiation and Adaptability Factors for Senior Dementia Patients Care Givers Department of Social Welfare, Seoul Welfare Graduate University Full-time Lecturer

More information

Journal of Educational Innovation Research 2017, Vol. 27, No. 3, pp DOI: (NCS) Method of Con

Journal of Educational Innovation Research 2017, Vol. 27, No. 3, pp DOI:   (NCS) Method of Con Journal of Educational Innovation Research 2017, Vol. 27, No. 3, pp.181-212 DOI: http://dx.doi.org/10.21024/pnuedi.27.3.201709.181 (NCS) Method of Constructing and Using the Differentiated National Competency

More information

CASE REPORT 전악무치악환자에서골이식술을선행한임플란트고정성보철수복증례 안주남 1 이정진 1 서재민 1 김경아 2 * 1 전북대학교치과대학치과보철학교실및구강생체과학연구소, 2 을지대학교의과

CASE REPORT   전악무치악환자에서골이식술을선행한임플란트고정성보철수복증례 안주남 1 이정진 1 서재민 1 김경아 2 * 1 전북대학교치과대학치과보철학교실및구강생체과학연구소, 2 을지대학교의과 CASE REPORT https://doi.org/10.4047/jkap.2018.56.1.77 전악무치악환자에서골이식술을선행한임플란트고정성보철수복증례 안주남 1 이정진 1 서재민 1 김경아 2 * 1 전북대학교치과대학치과보철학교실및구강생체과학연구소, 2 을지대학교의과대학치과학교실 Full mouth rehabilitation of fully edentulous

More information

( )Kju269.hwp

( )Kju269.hwp 만성세균성전립선염모델흰쥐에서 의항염효과 Anti-inflammatory Effect of Lycopene on Chronic Bacterial Prostatitis Rat Model Cho Hwan Yang, Dong Wan Sohn, Yong-Hyun Cho From the Department of Urology, The Catholic University

More information

12-3전체

12-3전체 One stage operation of large oroantral fistula closure, sinus lifting for dental implant installation Bu-Kyu Lee Department of Oral and Maxillofacial Surgery, Asan Medical Center, College of Medicine,

More information

00)14-1목차1~3

00)14-1목차1~3 The effect of MBCP TM bone regeneration in osteoporosis induced rats Won Hee Kim, Jeong Kyung Kang, Jae Jun Ryu Dept.of esthetic restorative dentistry, Graduate School of Clinical Dentistry, Korea University

More information

歯5-2-13(전미희외).PDF

歯5-2-13(전미희외).PDF The Korean Journal of Counseling 2004, Vol. 5, No. 2, 423-434,. 4 5 18 9, 9.,,,,,.,,, t-.. :,,, (,, 1996),.,,. (, 2001),... 88 98 2000, 88 12.5%(250 )98 35.6%(712 )2.8 (,,, 2001) (Corresponding Author)

More information

Journal of Educational Innovation Research 2018, Vol. 28, No. 4, pp DOI: * A Research Trend

Journal of Educational Innovation Research 2018, Vol. 28, No. 4, pp DOI:   * A Research Trend Journal of Educational Innovation Research 2018, Vol. 28, No. 4, pp.295-318 DOI: http://dx.doi.org/10.21024/pnuedi.28.4.201812.295 * A Research Trend on the Studies related to Parents of Adults with Disabilities

More information