Microsoft PowerPoint 전원공급 장치 Datasheet

Size: px
Start display at page:

Download "Microsoft PowerPoint 전원공급 장치 Datasheet"

Transcription

1

2 목차 직류전원공급장치 DR : 75W / 24V Din Rail NDR : 240W / 48V Din Rail 산업용 Managed L2/L3 스위치 산업용 1G/10G L2 No Bypass 스위치 ETK-5000B-P840D ETK-5000B-N840D 산업용 1G/10G L2 1Core Bypass 스위치 ETK-5000B-P842D ETK-5000B-N842D 산업용 1G/10G L2 2Core Bypass 스위치 ETK-5000B-P842D-2C ETK-5000B-N842D-2C 산업용 1G/2.5G L2 2Core Bypass 스위치 ETK-4000B-P842D-2C ETK-4000B-N842D-2C 산업용 1G/2.5G L2 1Core Bypass 스위치 ETK-4000B-P842D ETK-4000B-N842D ETK-4000B-N842A 산업용 1G/2.5G L2 No Bypass 스위치 ETK-4000B-P820D ETK-4000B-N820D ETK-4000B-N820A 직류전원공급장치 DR : 75W / 24V Din Rail NDR :240W / 48V Din Rail 2

3 직류전원공급장치 (SMPS) 주문정보 Mean well Din rail Type 직류전원공급장치 DR 제조사 : Mean well NDR 제조사 :Mean well 입력 : AC: 90~264V Free Voltage, 출력 : 75W,3.2A, 24VDC(Dual Pairs Terminal), Non PFC, 전력효율 : 80%, 과부하보호, 과전압보호기능, 고온보호기능, 공기냉각, Din rail, 제품크기 :55.5*125.2*100mm (W*H*D) 입력 : AC: 90~264V Free Voltage, 출력 : 240W, 48VDC,5A, 단자 2 쌍, PFC( 역율 ) :95%at 220V, 전력효율 :90%, 과부하, 과전압, 고온보호기능, Din Rail, 공기냉각방식제품크기 : 63*125.2*113.5mm (W*H*D) 산업용 L2 Bypass 스위치주문정보 구분모델명주요사양 1G/10G 산업용 L2 Managed 스위치 1G/10G 산업용 L2 Managed Bypass 스위치 1G/2.5G 산업용 L2 Managed 2 Core Bypass 스위치 1G/2.5G 산업용 L2 Managed 1Core Bypass 스위치 1G/2.5G 산업용 L2 Managed 스위치 산업용스위치 Accessory ETK-5000B-P840D ETK-5000B-N840D ETK-5000B-P842D ETK-5000B-N842D ETK-5000B-P842D-2C ETK-5000B-N842D-2C ETK-4000B-P842D-2C ETK-4000B-N842D-2C ETK-4000B-P842D ETK-4000B-N842D ETK-4000B-N842A ETK-4000B-P820D ETK-4000B-N820D ETK-4000B-N820A ACCESSORY KIT L2, P,oE/PoE+, 8x10/100/1000M,4x SFP/SFP+, No Bypass, Ring Protocol, 전원이중화 :+48VDC L2, 8x10/100/1000M,4x SFP/SFP+, No Bypass, Ring Protocol, 전원이중화 :+24VDC L2, P,oE, 8x10/100/1000M,4xSFP/SFP+, 1Core Bypass, Ring Protocol, 전원이중화 :+48VDC L2, Non P,oE, 8x10/100/1000M,4xSFP/SFP+, 1Core Bypass, Ring Protocol, 전원이중화 :+24VDC L2, P,oE, 8x10/100/1000M,4x 10G SFP, 2Core Bypass, Ring Protocol, 전원이중화 :+24VDC L2, Non-PoE, 8x10/100/1000M,4x 10G SFP, 2Core Bypass,Ring Protocol, 전원이중화 :+24VDC L2, PoE, 8x10/100/1000M, 4xSFP, 2 Core Bypass, Ring Protocol, 전원이중화 : +48VDC L2, Non-PoE, 8x10/100/1000M, 4xSFP, 2 Core Bypass, Ring Protocol, 전원이중화 :+24VDC L2, PoE, 8x10/100/1000M, 4xSFP, 1Core Bypass,Ring Protocol, 전원이중화 :+48VDC L2, Non -PoE, 8x10/100/1000M,4xSFP, 1Core Bypass, Ring Protocol, 전원이중화 :+24VDC L2, Non PoE, 8x10/100/1000M,4xSFP, 1Core Bypass, Ring Protocol, 전원이중화 : 220VAC L2, PoE, 8x10/100/1000M, 2xSFP, No Bypass, Ring Protocol, 전원이중화 :+48VDC L2, Non-PoE, 8x10/100/1000M, 2xSFP, No Bypass, Ring Protocol, 전원이중화 : +24VDC L2, Non-PoE, 8x10/100/1000M, 2xSFP, No Bypass, Ring Protocol, 전원이중화 : 220VAC Console Cable,Bypass Cable(SMF 2 Core or 1 Core ) 2EA, Din Rail Stopper, User s Manual NMS S/W ETK4000B-NMS ETK4000B /ETK-5000B Series 용 Network Management System Network Map 3

4 산업용스위치용광모듈주문정보 Item P/N Specification 100M SFP 1Core 100M SFP 1.25G SFP 1 CORE 1.25G SFP 10G SFP+ 1 CORE 10G SFP+ SFP-FE-100FXI-C SFP-FE-100LXI-C SFP-100BX-U20I-C SFP-100BX-D20I-C SFP-100BX-U40I-C SFP-100BX-D40I-C SFP-SX55(F)DI-C SFP-LX10(F)DI-C SFP-LX20(F)DI-C SFP-LX4013(F)DI-C SFP-LX4015(F)DI-C SFP-ZX80(F)DI-C SFP-LX10ADI-C SFP-LX10BDI-C SFP-LX20ADI-C SFP-LX20BDI-C SFP-LX40ADI-C SFP-LX40BDI-C SFP-ZX80ADI-C SFP-ZX80BDI-C SFP+10G-SRI-C SFP+10G-LRI-C SFP+LR10ADI-C SFP+LR10BDI-C SFP+LR20ADI-C SFP+LR20BDI-C SFP+LR40ADI-C SFP+LR40BDI-C 100M SFP, 100BASE-FX, 1310nm(FP), MMF, 2km, Duplex LC, 3.3V, -40~85, DDM 100M SFP, 100BASE-LX, 1310nm(FP) SMF, 20km, Duplex LC, 3.3V, -40~85, DDM 100M SFP, 100BASE-BX-U20, 1310nm/1550nm, SMF, 20km, Simplex LC,3.3V,-40~85, DDM 100M SFP, 100BASE-BX-D20, 1550nm/1310nm, SMF, 20km, Simplex LC,3.3V,-40~85, DDM 100M SFP, 100BASE-BX-U40, 1310nm/1550nm, SMF, 40km, Simplex LC,3.3V,-40~85, DDM 100M SFP, 100BASE-BX-D40, 1550nm/1310nm, SMF, 40km, Simplex LC,3.3V,-40~85, DDM 1.25Gb/s 1000BASE-SX,850nm(VCSEL) MMF, 550m, Duplex LC, 3.3V, -40~85, DDM, 1.25Gb/s 1000BASE-LX,1310nm( FP), SMF, 10km, Duplex LC, 3.3V,-40~85, DDM 1.25Gb/s 1000BASE-LX,1310nm( FP), SMF, 20km, Duplex LC, 3.3V,-40~85, DDM 1.25Gb/s 1000BASE-EX,1310nm(DFB), SMF, 40km, Duplex LC,3.3V, -40~85, DDM 1.25Gb/s 1000BASE-EX,1550nm( DFB), SMF, 40km, Duplex LC, 3.3V,-40~85, DDM 1.25G,1000BASE-ZX,1550nm(DFB),SMF, 80km, Duplex LC,3.3V, -40~85, DDM 1.25Gb/s 1000BASE-BX-U, 1310nm/1550nm, SMF, 10km, Duplex LC, 3.3V,-40~85, DDM 1.25Gb/s, 1000BASE-BX-D, 1550nm / 1310nm, SMF, 10km, Duplex LC, -40~85, DDM 1.25Gb/s 1000BASE-BX-U, 1310nm / 1550nm, SMF, 20km, Duplex LC, -40~85, DDM 1.25Gb/s, 1000BASE-BX-D, 1550nm / 1310nm, SMF, 20km, Duplex LC, -40~85, DDM 1.25Gb/s, 1000BASE-BX-U, 1310nm / 1550nm, SMF, 40km, Duplex LC, -40~85, DDM 1.25Gb/s, 1000BASE-BX-D, 1550nm / 1310nm, SMF, 40km, Duplex LC, -40~85,DDM 1.25Gb/s, 1000BASE-BX-U, 1490nm / 1550nm, SMF, 80km, Duplex LC, -40~85,DDM 1.25Gb/s, 1000BASE-BX-D, 1550nm / 1490nm, SMF, 80km, Duplex LC,-40~85,DDM 10G SFP+,10GBASE-SR, 10G, 850nm, MMF,300m(OM3), Duplex LC, 3.3V, -20~70,DDM 10G SFP+,10GBASE-LR 1310nm, SMF,10km, Duplex LC, 3.3V, -40~85, DDM 10G BIDI SFP+, 1270nm/1330nm DFB, SMF, 10km, Duplex LC, 3.3V, -40~85, DDM 10G BIDI SFP+, 1330nm/1270nm DFB, SMF, 10km, Duplex LC, 3.3V, -40~85, DDM 10G BIDI SFP+,1270nm/1330nm DFB, SMF, 20km, Duplex LC, 3.3V, -40~85, DDM 10G BIDI SFP+, 1330nm/1270nm DFB, SMF, 20km, Duplex LC, 3.3V, -40~85, DDM 10G BIDI SFP+,1270nm/1330nm DFB, SMF, 40km, Duplex LC, 3.3V, -40~85, DDM 10G BIDI SFP+, 1330nm/1270nm DFB, SMF, 40km, Duplex LC, 3.3V, -40~85, DDM 4

5 미디어컨버터및광모듈주문정보 구분모델명주요사양 FMC1100E-M2 100M MC, 10/100M 1xUTP, 100BASE-FX 1310nm, MMF, 2km, SC, 전원외장형 5V DC 100M MC FMC1100E-S20 FMC1100E-S40 FMC1100-M2 FMC1100-S20 FMC1100E-SFP SFP-FE-100FX-C 100M MC,10/100M 1xUTP, 100BASE-LX 1310nm, SMF, 20km, SC, 전원외장형 5V DC 100M MC, 10/100M 1xUTP, 100BASE-EX,1310nm, SMF, 40km, SC, 전원외장형 5V DC 100M MC,10/100M 1xUTP, 100BASE-FX,1310nm,MMF, 2km,SC, AC 110~220VAC 100M MC,10/100M 1xUTP, 100BASE-LX,1310nm, SMF 20km, SC, AC 110~220VAC 100M 미디어컨버터,10/100M 1xUTP, x 100BASE-X SFP Port,( 모듈별매 ), 전원외장형5VDC 100M, 100BASE-FX, 1310nm,MMF, 2km, Duplex LC, 3.3V,0~70 100M SFP Type & 광모듈 SFP-FE-100LX-C 100M, 100BASE-LX, 1310nm, SMF, 20km, Duplex LC, 3.3V, 0~70 SFP-FE-100EX-C 100M, 100BASE-EX,1310nm, SMF, 40km, Duplex LC, 3.3V, 0~70 SFP-FE-LX20AD-C 100M, Tx1310nm/Rx1550nm, SMF, 20km, Simplex LC, 0~70 ( SC 커넥터도가능 ) SFP-FE-LX20BD-C 100M, Tx1550nm/Rx1310nm, SMF, 20km, Simplex LC, 0~70 (SC 커넥터도가능 ) 1000M MC GMC2200E-M550 GMC2200E-S20 GMC2200-M550 GMC2200-S20 GMC2200E-SFP GMC2200-SFP 1000M MC,100/1000M 1xUTP, 1000BASE-SX, 850nm, MMF, 550m, SC, 전원외장형 5VDC 1000M MC,100/1000M 1xUTP, 1000BASE-LX,1310nm, SMF, 20km, SC, 전원외장형 5VDC 1000M MC,100/1000M 1xUTP, 1000BASE-SX,850nm,MMF, 550m, SC, AC 110~220VAC 1000M MC, 100/1000M 1xUTP, 1000BASE-LX,1310nm, SMF, 20km, SC, AC 110~220VAC 1000M MC, 100/1000M 1xUTP, 1000BASE-X, SFP Port ( 모듈별매 ), 전원외장형 5VDC 1000M MC, 100/1000M 1xUTP, 1000BASE-X, SFP Port ( 모듈별매 ), AC 110~220VAC SFP-SX55(F)D-C 1.25G, 850nm,MMF, 270m(OM1), Duplex LC, 3.3V, 0~70 SFP-LX10(F)D-C 1.25G, 1310nm, SMF, 10km, Duplex LC, 3.3V, 0~ M SFP Type MC & 광모듈 SFP-LX20(F)D-C 1.25G, 1310nm, SMF, 20km, Duplex LC, 3.3V 0~70, SFP-GE-LX10AD-C 1.25G, Tx1310nm/Rx1550nm, SMF, 10km, Simplex LC, 3.3V, 0~70, (SC 커넥터도가능 ) SFP-GE-LX10BD-C 1.25G, Tx1550nm/Rx1310nm, SMF, 10km, Simplex LC, 3.3V, 0~70 (SC 커넥터도가능 ) SFP-GE-LX20AD-C 1.25G, Tx1310nm/Rx1550nm, SMF, 20km, Simplex LC, 3.3V, 0~70 (SC 커넥터도가능 ) SFP-GE-LX20BD-C 1.25G, Tx1550nm/Rx1310nm, SMF, 20km, Simplex LC, 3.3V, 0~70 (SC 커넥터도가능 ) SFP-GE-LX40AD-C 1.25G, Tx1310nm/Rx1550nm, SMF, 40km, Simplex LC, 3.3V, 0~70 (SC 커넥터도가능 ) SFP-GE-LX40BD-C 1.25G, Tx1550nm/Rx1310nm, SMF, 40km, Simplex LC, 3.3V, 0~70 (SC 커넥터도가능 ) 10G MC GMC3300E-SFP 10G MC, 100/1000M/10G 1xUTP, 10GBASE-X, (SFP+ 모듈별매 ), 전원외장형 +5VDC SFP+10G-SR-C SFP+, 850nm,MMF, 300m(OM3), Duplex LC, 3.3V, DDM 0~70 10G 광모듈 SFP+10G-LR-C SFP+,1310nm,SMF, 10km, Duplex LC, 3.3V, DDM, 0~70 SFP+LR10AD-C 1 Core SFP+,Tx1270nm/Rx1330nm, SMF, 10km, Simplex LC,3.3V, DDM, 0~70 SFP+LR10BD-C 1 Core SFP+,Tx1330nm/Rx1270nm, SMF, 10km, Simplex LC, 3.3V, DDM, 0~70 MC Chassis MCR-14CH/D 2U 19 Rack type 14Slot Media converter Chassis, FMC1100E,GMC2200E Series 단독형 MC 수용 DC 5V, Un-management, 110~220V AC Dual Power Supply 5

6 직류전원공급장치 : DR W 24VDC 3.2A Dual Output Industrial DIN RAIL Bracket 제품 제품소개 : DR-75-24는 75W 24V 3.2A Din Rail Type 직류전원공급장치로함체내공간을효율적으로사용할수있으며입력전원 90~264VAC Free Voltage, 출력 75W, 24V를제공하며금속재질케이스를사용하여열발산이잘되도록설계되었습니다전력효율 80%, 작동온도는공기순환이되는환경하에서 -10 ~60 이며산업용장비에적합한제품으로, 완벽한과전압, 과부하보호기능을제공합니다 Features Universal AC input / Full range : 90~264VAC Non-PFC function Protections: Short circuit / Overload / Over voltage / Over temp. Cooling by free air convection Can be installed on DIN rail TS-3 5/7. 5 or 15 UL 508 (industrial control equipment) approved EN (EN ) industrial immunity level 100% full load burn-in test Applications 산업용스위치 (Industrial Switch) 공장자동화반도체조립장비 제품사양 출력 입력 보호기능 작동환경 안전성및 EMC MODEL DC 전압 / 정격전류 전압조정범위 / 정격전력 리플및노이즈최대값전압범위 / 주파수범위 24V / 3.2 A ( 전류범위 : 0~3.2A) 24~28V / 75W 효율효율 : 80% 150mVp-p 90 ~ 264VAC / 47~63Hz DR (Mean well) 교류전류 / 누설전류 1.6A/115VAC 0.96A/230VAC / 누설전류 <1mA / 240VAC 돌입 전류 20A/115VAC 40A/230VAC 과부하 / 보호형태 정격출력의 105 ~ 150% / 정전류제한방식, 장애요인제거시자동복구 과전압 / 보호형태 29 ~34V / 과전압유입시작동정지, 정상전압회복시정상작동 온도과부하 고온이될시출력전압정지, 온도가내려가면자동복구 작동온도 / 습도 -10 ~ +60 / 20 ~ 90% RH non-condensing 저장온도, 습도 -20 ~ +85, 10 ~ 95% RH 온도계수士 0.03% / (0 ~ 50 ) 안전성표준 UL508, TUV EN , EAC TP TC 004 approved ;(meet EN ) 내압시험 I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC 절연저항 I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25CC/ 70% RH EMC 방사 EN55032 (CISPR32), EN Class B, EN ,-3, EAC TP TC 020 에따름 EMC 내성 EN ,3,4,5,6,8,11, EN55024, EN (EN ), EN , heavy in dustry level, criteria A, EAC TP TC 020 에따름. 기타평균고장간격 (MTBF) 486.2K hrs min. MIL-HDBK-217F (25 ) 주문정보 모델명 DR SMPS-75WD-24V 주요사양 입력 : AC :90~264V Free Voltage, 출력 : 75W, 3.2A, 24VDC (Dual Pairs Terminal), Non PFC 전력효율 : 80%, 과부하보호, 과전압보호기능, High Temp 보호기능, 공기냉각방식, Din rail 제조사 :Mean well, 제품 Size: 55.5*125.2.*100mm (W*H*D) 6

7 직류 전원 공급 장치 : NDR W, 48VDC, 5A Dual Output, with PFC, Industrial DIN RAIL, Mean well 제품 제품 소개: NDE 은 Din rail Type 직류전원공급 장치로 제품의 폭이 63mm로 함체 내 공간을 효율적으로 사용 할 수 있게 설계되었으며, 입력전원 90~264VAC Free Voltage, 출력 240W 48V를 제공하며 금속 재질 케이스를 사용하여 열 발산이 잘 되도록 설계되었습니다 역률 95% 이상 성능 보유,전력효율은 90%, 작동온도는 공기 순환되는 환경하에서 -20 ~ 70 이며 산업용 장비에 적합한 제품으로, 완벽한 과부하 보호 기능을 제공 합니다 Features Universal AC input Full range Protection : Short circuit / Overload / Over voltage / Over temp. Cooling by free air convection Can be installed on DIN rail TS-35.5 or 15 UL 508(industrial control equipment)approved LED indicator for power on 100% full load burn-in test Fix switching frequency at 50Khz Applications 산업용 스위치 (Industrial Switch) 제품 사양 출력 입력 보호기능 작동환경 안전성 및 EMC MODEL DC 전압 / 정격 전류 전압조정범위 / 정격 전력 리플 및 노이즈 최대값 전압 범위 / 주파수 범위 역율 / 효율 교류 전류 / 누설 전류 돌입 전류 과 부하 / 보호 형태 과전압 / 보호형태 온도 과부하 작동온도/ 습도 저장온도, 습도 온도 계수 NDR V / 5 A (전류범위: 0~5A) 48~55V / 240W 150mVp-p ( Note2) 90 ~ 264VAC / 47~63Hz 최대부하시 PF>0.98/115VAC, PF>0.95/230VAC / 효율: 90% 2.5A/115VAC 1.3A/230VAC / 누설전류 <1mA / 240VAC 20A/115VAC 35A/230VAC 정격출력의 105 ~ 130% / 정 전류 제한 방식, 장애 요인 제거 시 자동 복구 56 ~65V / 과전압 유입 시 작동 정지, 정상전압 회복 시 정상 작동 고온이 될시 출력 전압 정지, 온 도가 내려가면 자동 복구 -20 ~ +70 / 20 ~ 95% RH non-condensing -40 ~ +85, 10 ~ 95% RH 士 0.03%/ (0 ~ 50 ) 안전성 표준 내압 시험 절연 저항 UL508, TUV EN , EAC TP TC 004 approved ;(meet EN ) I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25CC/ 70% RH EMC 방사 EN55032 (CISPR32), EN Class B, EN ,-3, EAC TP TC 020 EN ,3,4,5,6,8,11, EN55024, EN (EN ), EN , heavy indust ry level, criteria A, EAC TP TC K hrs min. MIL-HDBK-217F (25C C) EMC 내성 기 타 평균고장 간격 주문 정보 모델명 NDR 주요 사양 입력 전압: 90~264V Free Voltage, 정격전력: 240W, 출력전압: +48VDC, 전류: 5A 과전압, 과부하 보호회로 채택, 자동 복구기능 보유, Din Rail Bracket, 역률(PFC) : 95% 공기냉각방식, 제품 크기 : 63*125.2*113.5mm (W*H*D) 7

8 Managed Industrial 1G/10G L2 PoE/PoE+ Switch 제품 주요 사양 산업용 스위치: ETK-5000B-P840D Managed Industrial 1G/10G L2 PoE/PoE+ Switch, Din Rail Type 8x10/100/1000M UTP, PoE/PoE+, 4xSFP/SFP+(100M/1G /2.5G/10Gx4), Ring Protocol (Recovery Time<15ms) Din Rail Bracket(Standard), Wall Bracket (Option) 방진기능: IP40지원, 동작 온도 : -40~85, 공급 전원: Dual Power Block (+48VDC), 직류 전원 공급 장치: NDR : Din rail Type 정격출력:240W, 48~56V,5A,공기냉각방식,과부하,과전압보호,자동복구 입력전원:AC110~220V Free Voltage +48VDC DinRail Type 직류전원장치 스위치 전면 스위치 후면 제품 특징 1G/10G Industrial Managed L2 PoE/PoE+ Ethernet Switch ETK-5000B-P840D 산업용 스위치는 96Gb/s Switching Fabric 성능을 보유한 1G/10G L2 PoE/PoE+ 스위치 로 -40 ~ 85 에서 운용할 수 있으며 +48VDC를 사용하며 전원 이중화로 안정성을 높였습니다. Support to G.8032 ERPS Ring Protection ETK-5000B-P840D 는 ITU-T의 G.8032 ERPS(Ethernet Ring Protection Switching) 기능을 지원함으로, 본 스위치로 Ring을 구성 할 경우, 장비나 선로에 장애가 발생시 50ms 이내에 자동적으로 복구하는 기능을 제공합니다 (자체 HF-Ring은 15ms이내 복구) Support to Intelligent Management ETK-5000B-P840D는 관리자의 편의를 위해 Web Management, CLI, SNMP 등 다양한 USER 인터페이스 를 제공하며 또한 CoS, QoS, Bandwidth/Storm Control 및 ACL 등 Advanced Traffic Management 기능을 제공합니다. HTTPS, RADIUS, TACACS+ 등 서버 기반의 인증 기능을 지원합니다 1G/10G Industrial Managed L2 Switch ETK-5000B-P840D는 PoE/PoE+ 기능을 지원하는 8개의 10/100/1000M UTP Port 와 4개의 1G/10G 광 포트를 제공하는 스위치로, 4개의 광 포트 는 SFP/SFP+를 지원하여 트래픽을 효과적으로 관리 할 수 있으며 다양한 네트워크 환경에 응용 할 수 있으며 고온, 저온,고습 등 열악한 환경에서 사용 할 수 있습니다 8

9 제품주요 사양 제품 외형 인터페이스 동작표시 LED 동작 환경 전력관리 기능 Switching Features Redundancy Software Features Multicast Housing: Aluminum / Cooling: Fanless / Protection Class: IP40 Dimension: 75mm 155mm 128mm (W*H*D) / Weight: 1.0Kg Mounting: DIN-Rail (표준), Wall Mounting (Option) 8 Port 10/100/1000Base-T PoE/PoE+ (IEEE802.3 af/at) 4 Port SFP / SFP+ (100M*4 or 1.25G * 4 or 2.5G*4 or 10G SFP+ * 4) in Common - MMF: 1.25G: 550m, 10G :300m(OM3) - SMF : 1.25G :1310nm (10 ~40km),1550nm (50~80km),1 Core SFP :1310/1550nm 10G : 1310nm (10~40km) / 1550nm: (50~80km),1 Core SFP+ :1270/1330nm LEDs on Front Panel (R: Running, A: Alarm) / Speed Power LED: P1, P2 / Interface LED: Link/Act Storage and Operating Temperature : -40 ~ +85 C Ambient Relative Humidity:5-95%(non-condensing) Power Input : Standard: +48VDC / Alarm output: Support Terminal Block: 7 pin 5.08mm Spacing plug-in terminal block Power Consumption Full Lode 25W / Overload Protection: Support Reverse Polarity Protection Support / Redundancy Protection: Support Support to Protocol based VLAN / GVRP / MVR / IP Subnet based VLAN Support to Storm Control / Port flow control / Port speed limit Support to QoS, CoS, ToS / Diff serv mapping, SPQ/WRR queuing Support to 802.1Q VLAN & 802.1ad Q-in-Q provide Bridging Support to Static Routing, Support to HF-Ring with the recovery time 15ms Support to STP / RSTP / MSTP / LACP / ITU-T G.8032 Ethernet Ring Protection Support to IGMP v1/v2/v3 Snooping Support to MLD V1/V2 Snooping 네트워크 보안 Support to HTTPs / SSHv2 / RADIUS / TACACS+ / IEEE802.1X 관리 및 유지보수 기능 Support to IPv6, CLI-Console, WEB Base, CISCO-LIKE CLI, TFTP, TELNET SSH, SSL, SNMP v1/v2/v3 / RMON / Multi Port mirroring System Syslog / Micro USB Console Port / Rate Control IEEE 1588 Precision time Protocol (PTP) V3 IP Management Support to DHCP Clint/Server, IGMP Snooping /Client / Relay Standard Switch Properties 산업 표준 IEEE 802.3i 10Base-T / IEEE 802.3u 100Base-TX and 100Base-FX IEEE802.3ab 1000base-T / IEEE 802.3z 1000Base-X / IEEE 802.3x Flow control IEEE 802.1p QoS / CoS (Class of Service) Protocol for traffic prioritization IEEE 802.1q VLAN / IEEE802.1X Network Authentication IEEE802.3ab LLDP(Link Layer Discovery Protocol) IEEE802.1d STP / IEEE802.1w RSTP / IEEE 802.1s MSTP IEEE 802.1ad Stacked VLAN, Q-in-Q / IEEE 802.3az Energy Efficient Ethernet ITU-T G.8032 / Y.1344 ERPS(Ethernet Ring Protection Switch) Data Process : Store & Forward Protocol: CSMA/CD, IGMP v1v2v3 Snooping, TFTP, NTP, RMON Priority Queues: 8 / Number of VLANs: 4096 / VLAN ID: MAC Table: 32K / Packet Buffer: 32Mbit Switching Delay: <5μs / Throughput : 71.4Mpps / Switching Fabric: 96Gb/s Memory: 512MB / Flash: 32MB Rates: 10Gb/s:14,880,000pps 1000Mb/s Port: 1,488,000pps, 100Mb/s :148,800pps, 10Mb/s : 14,880pps EMI: FCC Part 15 Subpart B Class A, EN55022 Class A EMS: IEC (ESD) Level 3, IEC (RS) exceeds Level 3, IEC (EFT) Level 3;IEC (Surge) Level 3, IEC (CS) Level 2, IEC , IEC , IEC Machinery: Vibration: IEC / Shock: IEC / Free Fall: IEC

10 Managed Industrial 1G/10G L2 Non PoE Switch 제품 주요 사양 산업용 스위치: ETK-5000B-N840D Managed Industrial 1G/10G L2, Non PoE Switch,8x10/100/1000M UTP, 4xSFP/SFP+ Port (100M/1G /2.5G/10Gx4), Ring Protocol (Recovery Time<15ms) Din Rail Bracket(Standard), Wall Bracket (Option) 방진기능: IP40지원, 동작 온도 : -40~85, 공급 전원: Dual Power Block (+24VDC) 직류 전원 공급 장치:NDR : Din rail Bracket 정격출력: 75W,24V,3.2A,공기 냉각방식, 과부하,과전압보호,자동복구 입력전원: AC110~220V Free Voltage +24VDC DinRail Type 직류전원장치 스위치 전면 스위치 후면 제품 특징 1G/10G Industrial Managed L2 Non PoE Ethernet Switch ETK-5000B-N840D 산업용 스위치는 96Gb/s Switching Fabric 성능을 보유한 1G/10G L2 스위치로 -40 ~ 85 에서 운용할 수 있으며 +24VDC를 사용하며 전원 이중화로 안정성을 높였습니다. Support to G.8032 ERPS Ring Protection ETK-5000B-N840D 는 ITU-T의 G.8032 ERPS(Ethernet Ring Protection Switching) 기능을 지원함으로, 본 스위치로 Ring을 구성 할 경우, 장비나 선로에 장애가 발생시 50ms 이내에 자동적으로 복구하는 기능을 제공합니다 (자체 HF-Ring은 15ms이내 복구) Support to Intelligent Management ETK-5000B-N840D는 관리자의 편의를 위해 Web Management, CLI, SNMP 등 다양한 USER 인터페이스 를 제공하며 또한 CoS, QoS, Bandwidth/Storm Control 및 ACL 등 Advanced Traffic Management 기능을 제공합니다. HTTPS, RADIUS, TACACS+ 등 서버 기반의 인증 기능을 지원합니다 1G/10G Industrial Managed L2 Switch ETK-5000B-N840D는 8개의 10/100/1000M UTP Port 와 4개의 1G/10G 광 포트를 제공하는 스위치로, 4개의 광 포트 는 SFP/SFP+를 지원하여 트래픽을 효과적으로 관리 할 수 있으며 다양한 네트워크 환경에 응용 할 수 있으며 고온, 저온,고습 등 열악한 환경에서 사용 할 수 있습니다 10

11 제품주요 사양 제품 외형 인터페이스 동작표시 LED 동작 환경 전력관리 기능 Switching Features Redundancy Software Features Multicast Housing: Aluminum / Cooling: Fanless / Protection Class: IP40 Dimension: 75mm 155mm 128mm (W*H*D) / Weight: 1.0Kg Mounting: DIN-Rail (표준), Wall Mounting (Option) 8 Port 10/100/1000Base-T Non PoE 4 Port SFP / SFP+ (100M*4 or 1.25G * 4 or 2.5G*4 or 10G SFP+ * 4) in Common - MMF: 1.25G: 550m, 10G :300m(OM3) - SMF : 1.25G :1310nm (10 ~40km),1550nm (50~80km),1 Core SFP :1310/1550nm 10G : 1310nm (10~40km) / 1550nm: (50~80km),1 Core SFP+ :1270/1330nm LEDs on Front Panel (R: Running, A: Alarm) / Speed Power LED: P1, P2 / Interface LED: Link/Act Storage and Operating Temperature : -40 ~ +85 C Ambient Relative Humidity:5-95%(non-condensing) Power Input : Standard: +24VDC / Alarm output: Support Terminal Block: 7 pin 5.08mm Spacing plug-in terminal block Power Consumption Full Lode 25W / Overload Protection: Support Reverse Polarity Protection Support / Redundancy Protection: Support Support to Protocol based VLAN / GVRP / MVR / IP Subnet based VLAN Support to Storm Control / Port flow control / Port speed limit Support to QoS, CoS, ToS / Diff serv mapping, SPQ/WRR queuing Support to 802.1Q VLAN & 802.1ad Q-in-Q provide Bridging Support to Static Routing, Support to HF-Ring with the recovery time 15ms Support to STP / RSTP / MSTP / LACP / ITU-T G.8032 Ethernet Ring Protection Support to IGMP v1/v2/v3 Snooping Support to MLD V1/V2 Snooping 네트워크 보안 Support to HTTPs / SSHv2 / RADIUS / TACACS+ / IEEE802.1X 관리 및 유지보수 기능 Support to IPv6, CLI-Console, WEB Base, CISCO-LIKE CLI, TFTP, TELNET SSH, SSL, SNMP v1/v2/v3 / RMON / Multi Port mirroring System Syslog / Micro USB Console Port / Rate Control IEEE 1588 Precision time Protocol (PTP) V3 IP Management Support to DHCP Clint/Server, IGMP Snooping /Client / Relay Standard Switch Properties 산업 표준 IEEE 802.3i 10Base-T / IEEE 802.3u 100Base-TX and 100Base-FX IEEE802.3ab 1000base-T / IEEE 802.3z 1000Base-X / IEEE 802.3x Flow control IEEE 802.1p QoS / CoS (Class of Service) Protocol for traffic prioritization IEEE 802.1q VLAN / IEEE802.1X Network Authentication IEEE802.3ab LLDP(Link Layer Discovery Protocol) IEEE802.1d STP / IEEE802.1w RSTP / IEEE 802.1s MSTP IEEE 802.1ad Stacked VLAN, Q-in-Q / IEEE 802.3az Energy Efficient Ethernet ITU-T G.8032 / Y.1344 ERPS(Ethernet Ring Protection Switch) Data Process : Store & Forward Protocol: CSMA/CD, IGMP v1v2v3 Snooping, TFTP, NTP, RMON Priority Queues: 8 / Number of VLANs: 4096 / VLAN ID: MAC Table: 32K / Packet Buffer: 32Mbit Switching Delay: <5μs / Throughput : 71.4Mpps / Switching Fabric: 96Gb/s Memory: 512MB / Flash: 32MB Rates: 10Gb/s:14,880,000pps 1000Mb/s Port: 1,488,000pps, 100Mb/s :148,800pps, 10Mb/s : 14,880pps EMI: FCC Part 15 Subpart B Class A, EN55022 Class A EMS: IEC (ESD) Level 3, IEC (RS) exceeds Level 3, IEC (EFT) Level 3;IEC (Surge) Level 3, IEC (CS) Level 2, IEC , IEC , IEC Machinery: Vibration: IEC / Shock: IEC / Free Fall: IEC

12 Managed Industrial 1G/10G L2 PoE/PoE+ Bypass Switch 제품 주요 사양 산업용 스위치: ETK-5000B-P842D Managed Industrial 1G/10G L2 PoE/PoE+, Din Rail Type Switch 1Core SMF Bypass Port 8x10/100/1000M UTP, PoE/PoE+,4xSFP/SFP+(100M/1G /2.5G/10Gx4) Ring Protocol (Recovery Time<15ms), Din Rail Bracket(Standard), Wall Bracket (Option) 방진기능: IP40지원, 동작 온도 : -40~85, 공급 전원: Dual Power Block (+48VDC) 직류 전원 공급 장치: NDR : Din rail Type 정격출력: 240W, 48~56V,0~5A,공기냉각방식,과부하,과전압보호,자동복구 입력전원: AC110~220V Free Voltage +48VDC DinRail Type 직류전원장치 스위치 전면 스위치 후면 제품 특징 1G/10G Industrial Managed L2 PoE/PoE+ Ethernet Switch ETK-5000B-P842D 산업용 스위치는 96Gb/s Switching Fabric 성능을 보유한 1G/10G L2 PoE/PoE+ Bypass 스위치로 -40 ~ 85 에서 운용할 수 있으며,+48VDC를 사용하며 전원 이중화로 안정성을 높였습니다. Ethernet Redundancy Protocol 지원으로, 이중화된 Ring 구성이 가능하며 또한 광 신호 전송 중 전원이 다운되거나 광 케이블 단선 등의 문제 발생시 자동감지 후 5ms 이내에 Bypass Port를 통해서 광 신호를 우회시켜 중단 없는 네트워크 운영을 가능 하도록 합니다 Support to G.8032 ERPS Ring Protection ETK-5000B-P842D 는 ITU-T의 G.8032 ERPS(Ethernet Ring Protection Switching) 기능을 지원함으로, 본 스위치로 Ring을 구성 할 경우, 장비나 선로에 장애가 발생시 50ms 이내에 자동적으로 복구하는 기능을 제공합니다 (자체 HF-Ring은 15ms이내 복구) ETK-5000B-P842D 는 1Core Bypass 기능을 지원하며 Line형으로 네트워크를 구성 할 경우,특정 장비에 장애가 발생 하더라도 네트워크는 정상 작동하며 장애 발생 장비가 복구 시 자동적으로 5ms 이내 복구 하는 기능을 제공 합니다 Support to Intelligent Management ETK-5000B-P842D는 관리자의 편의를 위해 Web Management, CLI, SNMP 등 다양한 USER 인터페이스 를 제공하며 또한 CoS, QoS, Bandwidth/Storm Control 및 ACL 등 Advanced Traffic Management 기능을 제공합니다. HTTPS, RADIUS, TACACS+ 등 서버 기반의 인증 기능을 지원합니다 1G/10G Industrial Managed L2 Switch ETK-5000B-P842D는 PoE/PoE+기능을 지원하는 8개의 10/100/1000M UTP Port 와 4개의 1G/10G 광 포트 및 1쌍의 Bypass Port(1Core )를 제공하는 스위치로, 4개의 광 포트 는 SFP/SFP+를 지원하여 트래픽을 효과 적으로 관리 할 수 있으며 다양한 네트워크 환경에 응용 할 수 있으며 고온, 저온,고습 등 열악한 환경 에서 사용 할 수 있습니다 12

13 제품주요 사양 제품 외형 인터페이스 Bypass Port 동작표시 LED 동작 환경 전력관리 기능 Switching Features Redundancy Software Features Multicast Housing: Aluminum / Cooling: Fanless / Protection Class: IP40 Dimension: 75mm 155mm 128mm (W*H*D) / Weight: 1.0Kg Mounting: DIN-Rail (표준), Wall Mounting (Option) 8 Port 10/100/1000Base-T PoE (IEEE802.3 af/at) 4 Port SFP / SFP+ (100M*4 or 1.25G * 4 or 2.5G*4 or 10G SFP+ * 4) in Common - MMF: 1.25G: 550m, 10G :300m(OM3) - SMF : 1.25G :1310nm (10 ~40km),1550nm (50~80km),1 Core SFP :1310/1550nm 10G : 1310nm (10~40km) / 1550nm: (50~80km),1 Core SFP+ :1270/1330nm 1Core Bypass Port (LC/UPC) / Micro USB Console Port Optical interface: Simplex Single Mode Fiber LC/UPC Wavelength: 1 Core SFP 1310/1550nm (10~40km) 1 Core SFP+ 1270/1330nm( 10 ~ 40km) Fiber Optic Cable: SMF : Simplex LC / Insertion loss: 0.8dB LEDs on Front Panel (R: Running, A: Alarm) / Speed Power LED: P1, P2 / Interface LED: Link/Act Storage and Operating Temperature : -40 ~ +85 C Ambient Relative Humidity:5-95%(non-condensing) Power Input : Standard: +48VDC / Alarm output: Support Terminal Block: 7 pin 5.08mm Spacing plug-in terminal block Power Consumption Full Lode 25W / Overload Protection: Support Reverse Polarity Protection Support / Redundancy Protection: Support Support to Protocol based VLAN / GVRP / MVR / IP Subnet based VLAN Support to Storm Control / Port flow control / Port speed limit Support to QoS, CoS, ToS / Diff serv mapping, SPQ/WRR queuing Support to 802.1Q VLAN & 802.1ad Q-in-Q provide Bridging Support to Static Routing, Support to HF-Ring with the recovery time 15ms Support to STP / RSTP / MSTP / LACP / ITU-T G.8032 Ethernet Ring Protection Support to IGMP v1/v2/v3 Snooping Support to MLD V1/V2 Snooping 네트워크 보안 Support to HTTPs / SSHv2 / RADIUS / TACACS+ / IEEE802.1X 관리 및 유지보수 기능 Support to IPv6, CLI-Console, WEB Base, CISCO-LIKE CLI, TFTP, TELNET SSH, SSL, SNMP v1/v2/v3 / RMON / Multi Port mirroring System Syslog / Micro USB Console Port / Rate Control IEEE 1588 Precision time Protocol (PTP) IP Management Support to DHCP Clint/Server, IGMP Snooping /Client / Relay Standard Switch Properties 산업 표준 IEEE 802.3i 10Base-T / IEEE 802.3u 100Base-TX and 100Base-FX IEEE802.3ab 1000base-T / IEEE 802.3z 1000Base-X / IEEE 802.3x Flow control IEEE 802.1p QoS / CoS (Class of Service) Protocol for traffic prioritization IEEE 802.1q VLAN / IEEE802.1X Network Authentication IEEE802.3ab LLDP(Link Layer Discovery Protocol) IEEE802.1d STP / IEEE802.1w RSTP / IEEE 802.1s MSTP IEEE 802.1ad Stacked VLAN, Q-in-Q / IEEE 802.3az Energy Efficient Ethernet ITU-T G.8032 / Y.1344 ERPS(Ethernet Ring Protection Switch) Data Process : Store & Forward Protocol: CSMA/CD, IGMP v1v2v3 Snooping, TFTP, NTP, RMON Priority Queues: 8 / Number of VLANs: 4096 / VLAN ID: MAC Table: 32K / Packet Buffer: 32Mbit Switching Delay: <5μs / Throughput : 71.4Mpps / Switching Fabric: 96Gb/s Rates: 10Gb/s:14,880,000pps 1000Mb/s Port: 1,488,000pps, 100Mb/s :148,800pps, 10Mb/s : 14,880pps EMI: FCC Part 15 Subpart B Class A, EN55022 Class A EMS: IEC (ESD) Level 3, IEC (RS) exceeds Level 3, IEC (EFT) Level 3;IEC (Surge) Level 3, IEC (CS) Level 2, IEC , IEC , IEC Machinery: Vibration: IEC / Shock: IEC / Free Fall: IEC

14 Managed Industrial 1G/10G L2, Non PoE Bypass Switch 제품 주요 사양 산업용 스위치: ETK-5000B-N842D Managed Industrial 1G/10G L2 Non PoE, Din Rail Type Switch 1Core Bypass Port 8x10/100/1000M UTP, Non PoE,4xSFP+(1G or 10Gx4), Ring Protocol (Recovery Time<15ms) Din Rail Bracket(Standard), Wall Bracket (Option), 1Core SMF Bypass Port (LC/UPC) 방진기능: IP40지원, 동작 온도 : -40~85, 공급 전원: Dual Power Block (+24VDC) 직류 전원 공급 장치: DR-75-24: Din rail Bracket Type 정격출력: 75W, 24V, 0~3.2A, 공기냉각방식, 과부하,과전압 보호,자동복구 기능 보유 입력전원: AC 110~220V Free Voltage +24VDC Din Rail Type 직류전원장치 스위치 전면 스위치 후면 제품 특징 1G/10G Industrial Managed L2 Non PoE Ethernet Switch ETK-5000B-N842D 산업용 스위치는 96Gb/s Switching Fabric 성능을 보유한 1G/10G L2 Non PoE Bypass 스위치로 -40 ~ 85 에서 운용할 수 있으며,+24VDC를 사용하며 전원 이중화로 안정성을 높였습니다. Ethernet Redundancy Protocol 지원으로, 이중화된 Ring 구성이 가능하며 또한 광 신호 전송 중 전원이 다운되거나 광 케이블 단선 등의 문제 발생시 자동감지 후 5ms 이내에 Bypass Port를 통해서 광 신호를 우회시켜 중단 없는 네트워크 운영을 가능 하도록 합니다 Support to G.8032 ERPS Ring Protection ETK-5000B-N842D 는 ITU-T의 G.8032 ERPS(Ethernet Ring Protection Switching) 기능을 지원함으로, 본 스위치로 Ring을 구성 할 경우, 장비나 선로에 장애가 발생시 50ms 이내에 자동적으로 복구하는 기능을 제공합니다 (자체 HF-Ring은 15ms이내 복구) ETK-5000B-N842D 는 1Core Bypass 기능을 지원하며 Line형으로 네트워크를 구성 할 경우,특정 장비에 장애가 발생 하더라도 네트워크는 정상 작동하며 장애 발생 장비가 복구 시 자동적으로 5ms 이내 복구 하는 기능을 제공 합니다 Support to Intelligent Management ETK-5000B-N842D는 관리자의 편의를 위해 Web Management, CLI, SNMP 등 다양한 USER 인터페이스 를 제공하며 또한 CoS, QoS, Bandwidth/Storm Control 및 ACL 등 Advanced Traffic Management 기능을 제공합니다. HTTPS, RADIUS, TACACS+ 등 서버 기반의 인증 기능을 지원합니다 1G/10G Industrial Managed L2 Switch ETK-5000B-N842D는 8개의 10/100/1000M UTP Port 와 4개의 1G/10G 광 포트 및 1쌍의 Bypass Port(1Core ) 를 제공하는 스위치로, 4개의 광 포트 는 SFP/SFP+를 지원하여 트래픽을 효과적으로 관리 할 수 있으며 다양한 네트워크 환경에 응용 할 수 있으며 고온, 저온,고습 등 열악한 환경에서 사용 할 수 있습니다 14

15 제품주요 사양 제품 외형 인터페이스 Bypass Port 동작표시 LED 동작 환경 전력관리 기능 Switching Features Redundancy Software Features Multicast Housing: Aluminum / Cooling: Fanless / Protection Class: IP40 Dimension: 75mm 155mm 128mm (W*H*D) / Weight: 1.0Kg Mounting: DIN-Rail (표준), Wall Mounting (Option) 8 Port 10/100/1000Base-T 4 Port SFP / SFP+ (1.25G * 4 or 10G SFP+ * 4) in Common - MMF: 1.25G: 550m, 10G :300m(OM3) - SMF : 1.25G :1310nm (10 ~40km),1550nm (50~80km),1 Core SFP :1310/1550nm 10G : 1310nm (10~40km) / 1550nm: (50~80km),1 Core SFP+ :1270/1330nm 2 Core Bypass Port (LC/UPC) / Micro USB Console Port Optical interface: Duplex Single Mode Fiber LC/UPC Wavelength: 2Core SFP/ SFP+ : 850nm (OM3: 300m), 1310nm(10~40km) Fiber Optic Cable: SMF : Duplex LC / Insertion loss: 0.8dB LEDs on Front Panel (R: Running, A: Alarm) / Speed Power LED: P1, P2 / Interface LED: Link/Act Storage and Operating Temperature : -40 ~ +85 C Ambient Relative Humidity:5-95%(non-condensing) Power Input : Standard: +24VDC / Alarm output: Support Terminal Block: 7 pin 5.08mm Spacing plug-in terminal block Power Consumption Full Lode 25W / Overload Protection: Support Reverse Polarity Protection Support / Redundancy Protection: Support Support to Protocol based VLAN / GVRP / MVR / IP Subnet based VLAN Support to Storm Control / Port flow control / Port speed limit Support to QoS, CoS, ToS / Diffserv mapping, SPQ/WRR queuing Support to 802.1Q VLAN & 802.1ad Q-in-Q provide Bridging Support to Static Routing, Support to HF-Ring with the recovery time 15ms Support to STP / RSTP / MSTP / LACP / ITU-T G.8032 Ethernet Ring Protection Support to IGMP v1/v2/v3 Snooping Support to MLD V1/V2 Snooping 네트워크 보안 Support to HTTPs / SSHv2 / RADIUS / TACACS+ / IEEE802.1X 관리 및 유지보수 기능 Support to IPv6, CLI-Console, WEB Base, CISCO-LIKE CLI, TFTP, TELNET SSH, SSL, SNMP v1/v2/v3 / RMON / Multi Port mirroring System Syslog / Micro USB Console Port / Rate Control IEEE 1588 Precision time Protocol (PTP) IP Management Support to DHCP Clint/Server, IGMP Snooping /Client / Relay Standard Switch Properties 산업 표준 IEEE 802.3i 10Base-T / IEEE 802.3u 100Base-TX and 100Base-FX IEEE802.3ab 1000base-T / IEEE 802.3z 1000Base-X / IEEE 802.3x Flow control IEEE 802.1p QoS / CoS (Class of Service) Protocol for traffic prioritization IEEE 802.1q VLAN / IEEE802.1X Network Authentication IEEE802.3ab LLDP(Link Layer Discovery Protocol) IEEE802.1d STP / IEEE802.1w RSTP / IEEE 802.1s MSTP IEEE 802.1ad Stacked VLAN, Q-in-Q / IEEE 802.3az Energy Efficient Ethernet ITU-T G 8032 / Y.1344 ERPS(Ethernet Ring Protection Switch) Data Process : Store & Forward Protocol: CSMA/CD, IGMP v1v2v3 Snooping, TFTP, NTP, RMON Priority Queues: 8 / Number of VLANs: 4096 / VLAN ID: MAC Table: 32K / Packet Buffer: 32Mbit Switching Delay: <5μs / Throughput : 71.4Mpps / Switching Fabric: 96Gb/s Rates: 10Gb/s:14,880,000pps 1000Mb/s Port: 1,488,000pps, 100Mb/s :148,800pps, 10Mb/s : 14,880pps EMI: FCC Part 15 Subpart B Class A, EN55022 Class A EMS: IEC (ESD) Level 3, IEC (RS) exceeds Level 3, IEC (EFT) Level 3;IEC (Surge) Level 3, IEC (CS) Level 2, IEC , IEC , IEC Machinery: Vibration: IEC / Shock: IEC / Free Fall: IEC

16 Managed Industrial 1G/10G L2 PoE/PoE+, 2Core Bypass Switch 제품 주요 사양 산업용 스위치: ETK-5000B-P842D-2C Managed Industrial 1G/10G L2 PoE/PoE+, Din Rail Type Switch 8x10/100/1000M UTP, PoE,4xSFP+(1G or 10Gx4), Ring Protocol (Recovery Time<15ms) Din Rail Bracket(Standard), Wall Bracket (Option), 2Core SMF Bypass Port (LC/UPC) 방진기능: IP40지원, 동작 온도 : -40~85, 공급 전원: Dual Power Block (+48VDC) 직류전원 공급장치:NDR :Din rail 정격출력: 240W,48~56V,0~5A,공기냉각,과부하,과전압보호,자동복구기능 입력전원: AC110~220V Free Voltage +48VDC DinRail Type 직류전원장치 스위치 전면 스위치 후면 제품 특징 1G/10G Industrial Managed L2 PoE/PoE+ Ethernet Switch ETK-5000B-P842D-2C 산업용 스위치는 96Gb/s Switching Fabric 성능을 보유한 1G/10G L2 PoE/PoE+, 2Core Bypass 스위치로 -40 ~ 85 에서 운용할 수 있으며,+48VDC를 사용하며 전원 이중화로 안정성 을 높였습니다. Ethernet Redundancy Protocol 지원으로, 이중화된 Ring 구성이 가능하며 또한 광 신호 전송 중 전원이 다운되거나 광 케이블 단선 등의 문제 발생시 자동감지 후 5ms 이내에 Bypass Port를 통해서 광 신호를 우회시켜 중단 없는 네트워크 운영을 가능 하도록 합니다 Support to G.8032 ERPS Ring Protection ETK-5000B-P842D-2C 는 ITU-T의 G.8032 ERPS(Ethernet Ring Protection Switching) 기능을 지원함으로, 본 스위치로 Ring을 구성 할 경우, 장비나 선로에 장애가 발생시 50ms 이내에 자동적으로 복구하는 기능을 제공합니다 (자체 HF-Ring은 15ms이내 복구) ETK-5000B-P842D-2C 는 2Core Bypass 기능을 지원하며 Line형으로 네트워크를 구성 할 경우,특정 장비에 장애가 발생 하더라도 네트워크는 정상 작동하며 장애 발생 장비가 복구 시 자동적으로 5ms 이내 복구 하는 기능을 제공 합니다 Support to Intelligent Management ETK-5000B-P842D-2C는 관리자의 편의를 위해 Web Management, CLI, SNMP 등 다양한 USER 인터페이스 를 제공하며 또한 CoS, QoS, Bandwidth/Storm Control 및 ACL 등 Advanced Traffic Management 기능을 제공합니다. HTTPS, RADIUS, TACACS+ 등 서버 기반의 인증 기능을 지원합니다 1G/10G Industrial Managed L2 Switch ETK-5000B-P842D-2C는 PoE/PoE+ 기능을 지원하는 8개의 10/100/1000M UTP Port와 4개의 1G/10G 광 포트 및 1쌍의 Bypass Port(2Core )를 제공하는 스위치로, 4개의 광 포트 는 SFP/SFP+를 지원하여 트래픽을 효과 적으로 관리 할 수 있으며 다양한 네트워크 환경에 응용 할 수 있으며 고온, 저온,고습 등 열악한 환경 에서 사용 할 수 있습니다 16

17 제품주요 사양 제품 외형 인터페이스 Bypass Port 동작표시 LED 동작 환경 전력관리 기능 Switching Features Redundancy Software Features Multicast Housing: Aluminum / Cooling: Fanless / Protection Class: IP40 Dimension: 75mm 155mm 128mm (W*H*D) / Weight: 1.0Kg Mounting: DIN-Rail (표준), Wall Mounting (Option) 8 Port 10/100/1000Base-T PoE (IEEE802.3 af/at) 4 Port SFP / SFP+ (1.25G * 4 or 10G SFP+ * 4) in Common - MMF: 1.25G: 550m, 10G :300m(OM3) - SMF : 1.25G :1310nm (10 ~40km),1550nm (50~80km),1 Core SFP :1310/1550nm 10G : 1310nm (10~40km) / 1550nm: (50~80km),1 Core SFP+ :1270/1330nm 2 Core Bypass Port (LC/UPC) / Micro USB Console Port Optical interface: Duplex Single Mode Fiber LC/UPC Wavelength: 2Core SFP/ SFP+ : 850nm (OM3: 300m), 1310nm(10~40km) Fiber Optic Cable: SMF : Duplex LC / Insertion loss: 0.8dB LEDs on Front Panel (R: Running, A: Alarm) / Speed Power LED: P1, P2 / Interface LED: Link/Act Storage and Operating Temperature : -40 ~ +85 C Ambient Relative Humidity:5-95%(non-condensing) Power Input : Standard: +48VDC / Alarm output: Support Terminal Block: 7 pin 5.08mm Spacing plug-in terminal block Power Consumption Full Lode 25W / Overload Protection: Support Reverse Polarity Protection Support / Redundancy Protection: Support Support to Protocol based VLAN / GVRP / MVR / IP Subnet based VLAN Support to Storm Control / Port flow control / Port speed limit Support to QoS, CoS, ToS / Diffserv mapping, SPQ/WRR queuing Support to 802.1Q VLAN & 802.1ad Q-in-Q provide Bridging Support to Static Routing, Support to HF-Ring with the recovery time 15ms Support to STP / RSTP / MSTP / LACP / ITU-T G.8032 Ethernet Ring Protection Support to IGMP v1/v2/v3 Snooping Support to MLD V1/V2 Snooping 네트워크 보안 Support to HTTPs / SSHv2 / RADIUS / TACACS+ / IEEE802.1X 관리 및 유지보수 기능 Support to IPv6, CLI-Console, WEB Base, CISCO-LIKE CLI, TFTP, TELNET SSH, SSL, SNMP v1/v2/v3 / RMON / Multi Port mirroring System Syslog / Micro USB Console Port / Rate Control IEEE 1588 Precision time Protocol (PTP) IP Management Support to DHCP Clint/Server, IGMP Snooping /Client / Relay Standard Switch Properties 산업 표준 IEEE 802.3i 10Base-T / IEEE 802.3u 100Base-TX and 100Base-FX IEEE802.3ab 1000base-T / IEEE 802.3z 1000Base-X / IEEE 802.3x Flow control IEEE 802.1p QoS / CoS (Class of Service) Protocol for traffic prioritization IEEE 802.1q VLAN / IEEE802.1X Network Authentication IEEE802.3ab LLDP(Link Layer Discovery Protocol) IEEE802.1d STP / IEEE802.1w RSTP / IEEE 802.1s MSTP IEEE 802.1ad Stacked VLAN, Q-in-Q / IEEE 802.3az Energy Efficient Ethernet ITU-T G 8032 / Y.1344 ERPS(Ethernet Ring Protection Switch) Data Process : Store & Forward Protocol: CSMA/CD, IGMP v1v2v3 Snooping, TFTP, NTP, RMON Priority Queues: 8 / Number of VLANs: 4096 / VLAN ID: MAC Table: 32K / Packet Buffer: 32Mbit Switching Delay: <5μs / Throughput : 71.4Mpps / Switching Fabric: 96Gb/s Rates: 10Gb/s:14,880,000pps 1000Mb/s Port: 1,488,000pps, 100Mb/s :148,800pps, 10Mb/s : 14,880pps EMI: FCC Part 15 Subpart B Class A, EN55022 Class A EMS: IEC (ESD) Level 3, IEC (RS) exceeds Level 3, IEC (EFT) Level 3;IEC (Surge) Level 3, IEC (CS) Level 2, IEC , IEC , IEC Machinery: Vibration: IEC / Shock: IEC / Free Fall: IEC

18 Managed Industrial 1G/10G L2 Non PoE 2Core Bypass Switch 제품 주요 사양 산업용 스위치: ETK-5000B-N842D-2C Managed Industrial 1G/10G L2 Non PoE, Din Rail Type Switch 2Core Bypass Port 8x10/100/1000M UTP, Non PoE,4xSFP+(1G or 10Gx4), Ring Protocol (Recovery Time<15ms) Din Rail Bracket(Standard), Wall Bracket (Option), 2Core SMF Bypass Port (LC/UPC) 방진기능: IP40지원, 동작 온도 : -40~85, 공급 전원: Dual Power Block (+24VDC) 직류 전원 공급 장치: NDR / SMPS-75WD-24V: Din rail / SMPS-75W-24V (Wall Type) 정격전력: 75W,24V,0~3.2A,공기냉각방식, 과부하,과전압보호,자동복구,입력전원:AC110~220V Free Voltage +24VDC Din rail Type 직류전원장치 스위치 전면 스위치 후면 제품 특징 1G/10G Industrial Managed L2 Non-PoE Ethernet Switch ETK-5000B-N842D-2C 산업용 스위치는 96Gb/s Switching Fabric 성능을 보유한 1G/10G L2 스위치로 -40 ~ 85 에서 운용할 수 있으며, Power Block을 통해 이중화된 전원 공급 장치에 24VDC 전원을 공급하여 안정성을 높였습니다. Ethernet Redundancy Protocol 지원으로, 이중화된 Ring 구성이 가능하며 또한 광 신호 전송 중 전원 다운이나 광 케이블 단선 등의 문제 발생시 자동감지 후 5ms 이내에 Bypass Port를 통해서 광 신호를 우회시켜 중단 없는 네트워크 운영을 가능 하도록 합니다 Support to G.8032 ERPS Ring Protection ETK-5000B-N842D-2C는 ITU-T의 G.8032 ERPS(Ethernet Ring Protection Switching) 기능을 지원함으로, 본 스위치로 Ring을 구성 할 경우, 장비나 선로에 장애가 발생시 50ms 이내에 자동적으로 복구하는 기능을 제공합니다 (자체 HF-Ring은 15ms이내 복구) ETK-5000B-N842D-2C는 2Core Bypass 기능을 지원하며 Line형으로 네트워크를 구성 할 경우,특정 장비에 장애가 발생 하더라도 네트워크는 정상 작동하며 장애 발생 장비가 복구 시 자동적으로 5ms 이내 복구 하는 기능을 제공 합니다 Support to Intelligent Management ETK-5000B-N842D-2C는 관리자의 편의를 위해 Web Management, CLI, SNMP 등 다양한 USER 인터페이스 를 제공하며 또한 CoS, QoS, Bandwidth/Storm Control 및 ACL 등 Advanced Traffic Management 기능을 제공합니다. HTTPS, RADIUS, TACACS+ 등 서버 기반의 인증 기능을 지원합니다 1G/10G Industrial Managed L2 Switch ETK-5000B-N842D-2C는 8개의 10/100/1000M UTP Port 와 4개의 1G/10G 광 포트 및 1쌍의 Bypass Port (2Core )를 제공하는 스위치로, 4개의 광 포트 는 SFP/SFP+를 지원하여 트래픽을 효과적으로 관리 할 수 있으며 다양한 네트워크 환경에 응용 할 수 있으며 고온,저온,고습 등 열악한 환경에서 사용 할 수 있습니다 18

19 제품주요 사양 제품 외형 인터페이스 Bypass Port 동작표시 LED 동작 환경 전력관리 기능 Switching Features Redundancy Software Features Multicast Housing: Aluminum / Cooling: Fanless / Protection Class: IP40 Dimension: 75mm 155mm 128mm (W*H*D) / Weight: 1.0Kg Mounting: DIN-Rail (표준), Wall Mounting (Option) 8 x 10/100/1000Base-T 4 x SFP/SFP+ (1.25G * 4 or 10G SFP+ * 4) in Common - MMF: 1.25G: 550m, 10G :300m(OM3) - SMF : 1.25G :1310nm (10 ~40km),1550nm (50~80km),1 Core SFP :1310/1550nm 10G : 1310nm (10~40km) / 1550nm: (50~80km),1 Core SFP+ :1270/1330nm 2Core Bypass Port (LC/UPC) / Micro USB Console Port Optical interface: Duplex Single Mode Fiber LC/UPC Wavelength: 2Core SFP/ SFP+ : 850nm (OM3: 300m), 1310nm(10~40km) Fiber Optic Cable: SMF : Duplex LC / Insertion loss: 0.8dB LEDs on Front Panel (R: Running, A: Alarm) / Speed Power LED: P1, P2 / Interface LED: Link/Act Storage and Operating Temperature : -40 ~ +85 C Ambient Relative Humidity:5-95%(non-condensing) Power Input : Standard: +24VDC / Alarm output: Support Terminal Block: 7 pin 5.08mm-Spacing plug-in terminal block Power Consumption: 15W / Overload Protection: Support Reverse Protection: Support / Redundancy Protection: Support Support to Protocol based VLAN / GVRP / MVR / IP Subnet based VLAN Support to Storm Control / Port flow control / Port speed limit Support to QoS, CoS, ToS / Diffserv mapping, SPQ/WRR queuing Support to 802.1Q VLAN & 802.1ad Q-in-Q provide Bridging Support to Static Routing, Support to HF-Ring with the recovery time 15ms Support to STP / RSTP / MSTP / LACP / ITU-T G.8032 Ethernet Ring Protection Support to IGMP v1/v2/v3 Snooping Support to MLD V1/V2 Snooping 네트워크 보안 Support to HTTPs / SSHv2 / RADIUS / TACACS+ / IEEE802.1X 관리 및 유지보수 기능 Support to IPv6, CLI-Console, WEB Base, CISCO-LIKE CLI, TFTP, TELNET SSH, SSL, SNMP v1/v2/v3 / RMON / Multi Port mirroring System Syslog / Micro USB Console Port / Rate Control IEEE 1588 Precision time Protocol (PTP) IP Management Support to DHCP Clint/Server, IGMP Snooping /Client / Relay Standard Switch Properties 산업 표준 IEEE 802.3i 10Base-T / IEEE 802.3u 100Base-TX and 100Base-FX IEEE802.3ab 1000base-T / IEEE 802.3z 1000Base-X / IEEE 802.3x Flow control IEEE 802.1p QoS / CoS (Class of Service) Protocol for traffic prioritization IEEE 802.1q VLAN / IEEE802.1X Network Authentication IEEE802.3ab LLDP(Link Layer Discovery Protocol) IEEE802.1d STP / IEEE802.1w RSTP / IEEE 802.1s MSTP IEEE 802.1ad Stacked VLAN, Q-in-Q / IEEE 802.3az Energy Efficient Ethernet ITU-T G 8032 / Y.1344 ERPS(Ethernet Ring Protection Switch) Data Process : Store & Forward Protocol: CSMA/CD, IGMP v1v2v3 Snooping, TFTP, NTP, RMON Priority Queues: 8 / Number of VLANs: 4096 / VLAN ID: MAC Table: 32K / Packet Buffer: 32Mbit Switching Delay: <5μs / Throughput : 71.4Mpps / Switching Fabric: 96Gb/s Rates: 10Gb/s:14,880,000pps 1000Mb/s Port: 1,488,000pps, 100Mb/s :148,800pps, 10Mb/s : 14,880pps EMI: FCC Part 15 Subpart B Class A, EN55022 Class A EMS: IEC (ESD) Level 3, IEC (RS) exceeds Level 3, IEC (EFT) Level 3;IEC (Surge) Level 3, IEC (CS) Level 2, IEC , IEC , IEC Machinery: Vibration: IEC / Shock: IEC / Free Fall: IEC

20 Managed Industrial 1G/2.5G L2 PoE 2Core Bypass Switch 제품 주요 사양 산업용 스위치: ETK-4000B-P842D-2C Managed Industrial L2, PoE, Ethernet Switch 1Pair Bypass Port (2Core) 8 x 10/100/1000M UTP Port, PoE, 4 x SFP(100M x 4 or 1.25G x 4 or,1.25g x G x 2) 1 Pair Bypass Port (2 Core LC/UPC), Ring Protocol, Din rail 방진기능: IP40지원,동작온도:-40~85 Power Block(+48VDC) 전원 이중화 직류 전원 공급 장치: NDR / SMPS-240WD-48V: Din rail / SMPS-240W-48V(Wall Type) 정격전력:240W,48~56V,0~5A,공기냉각방식,과부하,과전압보호,자동복구,AC110~220V Free Voltage +48VDC 직류전원장치 스위치 전면 스위치 후면 제품 특징 Industrial Managed L2 PoE Switch with 1 Pair Bypass Port (2 core) ETK-4000B-P842D -2C 산업용 스위치는 30Gbps Switching Fabric 성능을 보유한 Gigabit L2 PoE Bypass Ethernet 스위치로 -40 ~ 85 에서 운용할 수 있으며, +48VDC 전원 이중화로 안정성을 높였습니다. Ethernet Redundancy Protocol 지원으로, 이중화된 Ring 구성이 가능하며, 광 신호 전송 중 전원 다운/광 케이블 단선 등의 문제 발생시 자동감지 및 보호 기능으로, Bypass Port를 통해서 광 신호를 우회시켜 네트워크에 작동에 영향을 주지 않고 안정적으로 통신을 할 수 있습니다 Support to G.8032 ERPS Ring Protection ETK-4000B-P842D-2C는 ITU-T의 G.8032 ERPS(Ethernet Ring Protection Switching) 기능을 지원함으로, 본 스위치로 Ring을 구성 할 경우, 장비나 선로에 장애가 발생시 50ms 이내에 자동적으로 복구하는 기능을 제공합니다 (자체 HF-Ring은 15ms이내 복구) ETK-4000B-P842D-2C는 2 Core Bypass 기능을 지원하며 Line형으로 네트워크를 구성 할 경우, 특정 장비에 장애가 발생 하더라도 네트워크는 정상 작동하며 장애 발생 장비가 복구 시 자동적으로 5ms 이내 복구 하는 기능을 제공 합니다 Support to Intelligent Management ETK-4000B-P842D-2C 는 관리자의 편의를 위해 Web Management, CLI, SNMP 등 다양한 USER 인터페이스 를 제공하며 또한 CoS, QoS, Bandwidth/Storm Control 및 ACL 등 Advanced Traffic Management 기능을 제공합니다. HTTPS, RADIUS, TACACS+ 등 서버 기반의 인증 기능을 지원합니다 Gigabit Managed L2 PoE Switch ETK-4000B-P842D-2C는 8개의 10/100/1000M UTP Port와 4개의 기가 비트 광 포트 및 1쌍의 Bypass Port (2Core) 를 제공하는 스위치로, 4개의 광 포트 중 2개는 2.5G SFP를 지원하여 트래픽을 효과적으로 관리 할 수 있으며 다양한 네트워크 환경에 응용 할 수 있으며 고온, 저온,고습 등 열악한 환경에서 사용 할 수 있습니다 Support to Static Routing 32개의 경로를 지정할 수 있는 STATIC ROUTING 기능을 제공하므로 특정 목적지의 네트워크로 가는 경로 를 관리자의 의도대로 정밀하게 제어할 수 있습니다. 산업용 L2 스위치 NMS 소프트웨어 제공 (옵션) 네트워크 운영자에게 Network의 동작 및 장애 상태를 실시간으로 감지하여 알려줌으로써 신속하게 장애 복구를 할 수 있도록 하는 NMS S/W를 제공 합니다. 20

21 제품 주요 사양 Redundancy Software Features Housing: Metal / Cooling: Fanless / Protection Class: IP40 Dimension: 78mm 197mm 105mm (W*H*D) / Weight: 1.0Kg Mounting: DIN-Rail (표준), Wall Mounting (Option) 8 Port 10/100/1000Base-T PoE/ PoE+ (IEEE802.3af/at) 4 Port SFP (100M *4 or 1.25G * 4 or 1.25G* G *2) 2 Core Bypass Port 1 Pair (LC/UPC) Micro USB Console Port Optical interface: Duplex Single Mode Fiber LC/UPC Wavelength: 1310nm (10~40km) Fiber Optic Cable: Single Mode Duplex LC Insertion loss: 0.8dB LEDs on Front Panel (R: Running, A: Alarm) Power LED: P1, P2 / Interface LED: Link Storage And Operating Temperature : -40 ~ +85 C Ambient Relative Humidity:5-95%(non-condensing) Power Input : Standard: +48VDC / Alarm output: Support Terminal Block: 7 pin 5.08mm-Spacing plug-in terminal block Power Consumption: 15W / Overload Protection: Support Reverse Protection: Support / Redundancy Protection: Support Support to VLAN / GVRP Support to Storm Control / Port flow control / Port speed limit Support to QoS, CoS, ToS / Diffserv mapping, SPQ/WRR queuing Support to 802.1Q VLAN & 802.1ad Q-in-Q provide Bridging Support to Static Routing(L3 Basic) Support to HF-Ring with the recovery time 15ms Support to STP / RSTP / MSTP / LACP / ITU-T G.8032 Ethernet Ring Protection Multicast Support to IGMP v1/v2/v3 Snooping 네트워크 보안 Support to HTTPs / SSHv2 / RADIUS / TACACS+ / IEEE802.1X 관리 및 유지보수 기능 Support to IPv6, CLI-Console, WEB Base, CISCO-LIKE CLI, TFTP, TELNET SSH, SSL, SNMPv1/v2/v3 / RMON / Multiport Port mirroring System Syslog / Micro USB Console Port / Rate Control IEEE 1588 Precision time Protocol (PTP) IP Management Support to DHCP Clint/Server, IGMP Snooping /Client / Relay 제품 외형 인터페이스 Bypass Port 동작표시 LED 동작 환경 전력관리 기능 Switching Features Standard Switch Properties 산업 표준 IEEE 802.3i 10Base-T / IEEE 802.3u 100Base-TX and 100Base-FX IEEE802.3ab 1000base-T / IEEE 802.3z 1000Base-X / IEEE 802.3x Flow control IEEE 802.1p QoS / CoS (Class of Service) Protocol for traffic prioritization IEEE 802.1Q VLAN / IEEE802.1X Network Authentication IEEE802.3ab LLDP(Link Layer Discovery Protocol) IEEE802.1d STP / IEEE802.1w RSTP / IEEE802.1s MSTP IEEE 802.1ad Stacked VLAN, Q-in-Q ITU-T G 8032 / Y.1344 ERPS(Ethernet Ring Protection Switch) Data Process : Store & Forward Protocol: CSMA/CD, IGMP v1v2v3 Snooping, TFTP, NTP, RMON Priority Queues: 8 / Number of VLANs: 4096 / VLAN ID: MAC Table: 8K / Packet Buffer: 4Mbit Switching Delay: <5μs / Throughput: 22.32Mpps / Switching fabric: 30G Rates: 1000Mb/s Port: 1,488,000pps, 100Mb/s :148,800pps, 10Mb/s : 14,880pps 2.5Gb/s: 2,976,000pps EMI: FCC Part 15 Subpart B Class A, EN55022 Class A EMS: IEC (ESD) Level 3, IEC (RS) exceeds Level 3, IEC (EFT) Level 3;IEC (Surge) Level 3, IEC (CS) Level 2, IEC , IEC , IEC Machinery: Vibration: IEC / Shock: IEC / Free Fall: IEC

22 Managed Industrial 1G/2.5G L2 Non PoE 2Core Bypass Switch 제품 주요 사양 산업용 스위치: ETK-4000B-N842D-2C Managed Industrial L2, Ethernet Switch, Non PoE, 2Core Bypass Port 8 x 10/100/1000M UTP (Non PoE), 4xSFP(100Mx4 or 1.25Gx4 or 1.25G x G x 2) 2Core Bypass Port (LC/UPC),Ring Protocol, Din rail,방진기능:ip40지원,동작온도: -40~85 Power Block(+24VDC) 전원이중화, 직류 전원 공급 장치: NDR / SMPS-75WD-24V: Din rail / SMPS-75W-24V (Wall Type) 정격전력:75W, 24V,0~3.2A,공기냉각,과부하,과전압 보호,자동복구,AC110~220V Free Voltage +24VDC 직류전원장치 스위치 전면 제품 특징 Industrial Managed L2 switch 2 Core Bypass Port 스위치 후면 ETK-4000B-N842D-2C 산업용 스위치는 30Gbps Switching Fabric 성능을 보유한 Gigabit L2 Bypass Ethernet 스위치로 -40 ~ 85 에서 운용할 수 있으며, +24VDC 전원 이중화로 안정성을 높였습니다. Ethernet Redundancy Protocol 지원으로, 이중화된 Ring 구성이 가능하며, 광 신호 전송 중 전원 다운/광 케이블 단선 등의 문제 발생시 자동감지 및 보호 기능으로, Bypass Port를 통해서 광 신호를 우회시켜 네 트워크에 작동에 영향을 주지 않고 안정적으로 통신을 할 수 있습니다 Support to G.8032 ERPS Ring Protection ETK-4000B-N842D-2C는 ITU-T의 G.8032 ERPS(Ethernet Ring Protection Switching) 기능을 지원함으로, 본 스위치로 Ring을 구성 할 경우, 장비나 선로에 장애가 발생시 50ms 이내에 자동적으로 복구하는 기능 을 제공합니다 (자체 HF-Ring은 15ms이내 복구) ETK-4000B-N842D-2C는 2 Core Bypass 기능을 지원하며 Line형으로 네트워크를 구성 할 경우, 특정 장비에 장애가 발생 하더라도 네트워크는 정상 작동하며 장애 장비가 장애 복구 시 자동적으로 5ms 이내 복구 하는 기능을 제공 합니다 Support to Intelligent Management ETK-4000B-N842D-2C 는 관리자의 편의를 위해 Web Management, CLI, SNMP 등 다양한 USER 인터페이스 를 제공하며 또한 CoS, QoS, Bandwidth/Storm Control 및 ACL 등 Advanced Traffic Management 기능을 제공합니다. HTTPS, RADIUS, TACACS+ 등 서버 기반의 인증 기능을 지원합니다 Gigabit Managed Switch ETK-4000B-N842D-2C는 8개의 10/100/1000M UTP Port와 4개의 기가 비트 광 포트 및 1쌍의 Bypass Port (2Core)를 제공하는 스위치로, 4개의 광 포트 중 2개는 2.5G SFP를 지원하여 트래픽을 효과적으로 관리 할 수 있으며 다양한 네트워크 환경에 응용 할 수 있으며 고온, 저온,고습 등 열악한 환경에서 사용 할 수 있습니다 Support to Static Routing : 32개의 경로를 지정할 수 있는 STATIC ROUTING 기능을 제공하므로 특정 목적지의 네트워크로 가는 경로를 관리자의 의도대로 정밀하게 제어할 수 있습니다. 산업용 L2 스위치 NMS 소프트웨어 제공 (옵션) 네트워크 운영자에게 Network의 동작 및 장애 상태를 실시간으로 감지하여 알려줌으로써 신속하게 장애 복구를 할 수 있도록 하는 NMS S/W를 제공 합니다. 22

23 제품 주요 사양 Redundancy Software Features Housing: Metal / Cooling: Fanless / Protection Class: IP40 Dimension: 78mm 197mm 105mm (W*H*D) / Weight: 1.0Kg Mounting: DIN-Rail (표준), Wall Mounting (Option) 8 Port 10/100/1000Base-T 4 Port SFP (100M *4 or 1.25G * 4 or 1.25G* G *2) 2 Core Bypass Port 1 Pair (LC/UPC) Micro USB Console Port Optical interface: Duplex Single Mode Fiber LC/UPC Wavelength: 1310nm (10~40km) Fiber Optic Cable: Single Mode Duplex LC Insertion loss: 0.8dB LEDs on Front Panel (R: Running, A: Alarm) Power LED: P1, P2 / Interface LED: Link Storage And Operating Temperature : -40 ~ +85 C Ambient Relative Humidity:5-95%(non-condensing) Power Input : Standard: +24VDC / Alarm output: Support Terminal Block: 7 pin 5.08mm-Spacing plug-in terminal block Power Consumption: 15W / Overload Protection: Support Reverse Protection: Support / Redundancy Protection: Support Support to VLAN / GVRP Support to Storm Control / Port flow control / Port speed limit Support to QoS, CoS, ToS / Diffserv mapping, SPQ/WRR queuing Support to 802.1Q VLAN & 802.1ad Q-in-Q provide Bridging Support to Static Routing(L3 Basic) Support to HF-Ring with the recovery time 15ms Support to STP / RSTP / MSTP / LACP / ITU-T G.8032 Ethernet Ring Protection Multicast Support to IGMP v1/v2/v3 Snooping 네트워크 보안 Support to HTTPs / SSHv2 / RADIUS / TACACS+ / IEEE802.1X 관리 및 유지보수 기능 Support to IPv6, CLI-Console, WEB Base, CISCO-LIKE CLI, TFTP, TELNET SSH, SSL, SNMPv1/v2/v3 / RMON / Multiport Port mirroring System Syslog / Micro USB Console Port / Rate Control IEEE 1588 Precision time Protocol (PTP) IP Management Support to DHCP Clint/Server, IGMP Snooping /Client / Relay 제품 외형 인터페이스 Bypass Port 동작표시 LED 동작 환경 전력관리 기능 Switching Features Standard Switch Properties 산업 표준 IEEE 802.3i 10Base-T / IEEE 802.3u 100Base-TX and 100Base-FX IEEE802.3ab 1000base-T / IEEE 802.3z 1000Base-X / IEEE 802.3x Flow control IEEE 802.1p QoS / CoS (Class of Service) Protocol for traffic prioritization IEEE 802.1Q VLAN / IEEE802.1X Network Authentication IEEE802.3ab LLDP(Link Layer Discovery Protocol) IEEE802.1d STP / IEEE802.1w RSTP / IEEE802.1s MSTP IEEE 802.1ad Stacked VLAN, Q-in-Q ITU-T G 8032 / Y.1344 ERPS(Ethernet Ring Protection Switch) Data Process : Store & Forward Protocol: CSMA/CD, IGMP v1v2v3 Snooping, TFTP, NTP, RMON Priority Queues: 8 / Number of VLANs: 4096 / VLAN ID: MAC Table: 8K / Packet Buffer: 4Mbit Switching Delay: <5μs / Throughput: 22.32Mpps / Switching fabric: 30G Rates: 1000Mb/s Port: 1,488,000pps, 100Mb/s :148,800pps, 10Mb/s : 14,880pps 2.5Gb/s: 2,976,000pps EMI: FCC Part 15 Subpart B Class A, EN55022 Class A EMS: IEC (ESD) Level 3, IEC (RS) exceeds Level 3, IEC (EFT) Level 3;IEC (Surge) Level 3, IEC (CS) Level 2, IEC , IEC , IEC Machinery: Vibration: IEC / Shock: IEC / Free Fall: IEC

24 Managed Industrial 1G/2.5G L2 PoE 1Core Bypass Switch 제품 주요 사양 산업용 스위치: ETK-4000B-P842D Managed Industrial L2 PoE Ethernet Switch,1 Core Bypass Port 8 x 10/100/1000M UTP Port, PoE, 4 x SFP (100M x 4 or 1.25G x 4 or, 1.25G x G x 2) 1 Core Bypass Port (LC/UPC), Ring Protocol, 방진기능: IP40지원, 동작 온도 : -40~85 Power Block(+48VDC) 전원 이중화, Din Rail 직류전원공급장치:NDR /SMPS-240WD-48V:Din rail / SMPS-240W-48V(Wall Type) 정격전력:240W,48~56V,5A,공기냉각,과부하 과전압보호,자동복구,입력전원:AC110~220V Free Voltage +48VDC Din Rail Type 직류전원장치 제품 특징 스위치 전면 스위치 후면 Industrial Managed L2 switch 1 Core Bypass Port ETK-4000B-P842D 산업용 스위치는 30Gbps Switching Fabric 성능을 보유한 Gigabit L2 PoE Ethernet 스위치로 -40 ~ 85 에서 운용할 수 있으며, +48VDC 전원 이중화로 안정성을 높였습니다. Ethernet Redundancy Protocol 지원으로 이중화된 Ring 구성이 가능하며, 광 신호 전송 중 전원 다운 또 는 광 케이블 단선 등, 문제 발생시 자동감지 및 보호 기능으로, Bypass Port를 통해서 광 신호를 우회시켜 네트워크에 작동에 영향을 주지 않고 안정적으로 통신을 할 수 있습니다. Support to G.8032 ERPS Ring Protection ETK-4000B-P842D는 ITU-T의 G.8032 ERPS(Ethernet Ring Protection Switching) 기능을 지원함으로, 본 스위치로 Ring을 구성 할 경우, 장비나 선로에 장애가 발생시 50ms 이내에 자동적으로 복구하는 기능 을 제공합니다 (자체 HF-Ring은 15ms이내 복구) ETK-4000B-P842D는 1 Core Bypass 기능을 지원하며 Line형으로 네트워크를 구성 할 경우, 특정 장비에 장애가 발생 하더라도 네트워크는 정상 작동하며 장애 장비가 장애 복구 시 자동적으로 5ms 이내 복구 하는 기능을 제공 합니다 Support to Intelligent Management ETK-4000B-P842D 는 관리자의 편의를 위해 Web Management, CLI, SNMP 등 다양한 USER 인터페이스를 지원하며, CoS, QoS, Bandwidth/Storm Control 및 ACL 등 Advanced Traffic Management 기능과 HTTPS, RADIUS, TACACS+ 등 서버 기반의 인증 기능을 지원 합니다 Gigabit PoE Switch ETK-4000B-P842D는 PoE기능을 지원하는 8개의 10/100/1000M UTP PoE Port와 4개의 기가 비트 광 포트 및 1쌍의 Bypass Port를 제공하며, 광 포트 4개 중 2개는 2.5G SFP를 지원하여 트래픽을 효과적으로 관리 할 수 있으며 PoE기능을 제공 함으로 CCTV망 등에 다양하게 응용 할 수 있으며 고온, 저온,고습 등 열악한 환경에서 사용 할 수 있습니다 Support to Static Routing 32개의 경로를 지정할 수 있는 STATIC ROUTING 기능을 제공하므로 특정 목적지의 네트워크로 가는 경로 를 관리자의 의도대로 정밀하게 제어할 수 있습니다. 산업용 L2 스위치 NMS 소프트웨어 제공 (옵션) 네트워크 운영자에게 Network의 동작 및 장애 상태를 실시간으로 감지하여 알려줌으로써 신속하게 장애 복구를 할 수 있도록 하는 NMS S/W를 제공 합니다. 24

25 제품 주요 사양 Redundancy Software Features Housing: Metal / Cooling: Fanless / Protection Class: IP40 Dimension: 78mm 197mm 105mm (W*H*D) / Weight: 1.0Kg Mounting: DIN-Rail (표준), Wall Mounting (Option) 8 Port 10/100/1000Base-T (PoE Support) 4 Port SFP (100M *4 or 1.25G * 4 or 1.25G* G *2) 1 Pair Bypass Port Micro USB Console Port Optical interface: Simplex Single Mode Fiber LC/PC Wavelength: 1310nm/1550nm, Fiber Optic Cable: Single Mode Insertion loss: 0.8dB LEDs on Front Panel (R: Running, A: Alarm) Power LED: P1, P2 / Interface LED: Link Storage And Operating Temperature : -40 ~ +85 C Ambient Relative Humidity:5-95%(non-condensing) Power Input : Standard: +48VDC / Alarm output: Support Terminal Block: 7 pin 5.08mm-Spacing plug-in terminal block Power Consumption: 15W / Overload Protection: Support Reverse Protection: Support / Redundancy Protection: Support Support to VLAN / GVRP Support to Storm Control / Port flow control / Port speed limit Support to QoS, CoS, ToS / Diffserv mapping, SPQ/WRR queuing Support to 802.1Q VLAN & 802.1ad Q-in-Q provide Bridging Support to Static Routing (L3 basic) Support to HF-Ring with the recovery time 15ms Support to STP / RSTP / MSTP / LACP / ITU-T G.8032 Ethernet Ring Protection Multicast Support to IGMP v1/v2/v3 Snooping 네트워크 보안 Support to HTTPs / SSHv2 / RADIUS / TACACS+ / IEEE802.1X 관리 및 유지보수 기능 Support to IPv6, CLI-Console, WEB Base, CISCO-LIKE CLI, TFTP, TELNET SSH, SSL, SNMPv1/v2/v3 / RMON / Multiport Port mirroring System Syslog / Micro USB Console Port / Rate Control IEEE 1588 Precision time Protocol (PTP) IP Management Support to DHCP Clint/Server, IGMP Snooping /Client / Relay Standard IEEE 802.3i 10Base-T / IEEE 802.3u 100Base-TX and 100Base-FX IEEE802.3ab 1000base-T / IEEE 802.3z 1000Base-X / IEEE 802.3x Flow control IEEE 802.1p QoS / CoS (Class of Service) Protocol for traffic prioritization IEEE 802.1Q VLAN / IEEE802.1X Network Authentication IEEE802.3ab LLDP(Link Layer Discovery Protocol) IEEE802.1d STP / IEEE802.1w RSTP / IEEE802.1s MSTP IEEE 802.1ad Stacked VLAN, Q-in-Q / IEEE 802.3at / IEEE 802.3af (PoE) ITU-T G 8032 / Y.1344 ERPS(Ethernet Ring Protection Switch) Switch Properties Data Process : Store & Forward Protocol: CSMA/CD, IGMP v1v2v3 Snooping, TFTP, NTP, RMON Priority Queues: 8 / Number of VLANs: 4096 / VLAN ID: MAC Table: 8K / Packet Buffer: 4Mbit Switching Delay: <5μs / Throughput: 22.32Mpps / Switching fabric: 30G Rates: 1000Mb/s Port: 1,488,000pps, 100Mb/s :148,800pps, 10Mb/s : 14,880pps 2.5Gb/s: 2,976,000pps 산업 표준 EMI: FCC Part 15 Subpart B Class A, EN55022 Class A EMS: IEC (ESD) Level 3, IEC (RS) exceeds Level 3, IEC (EFT) Level 3;IEC (Surge) Level 3, IEC (CS) Level 2, IEC , IEC IEC Machinery: Vibration: IEC / Shock: IEC Free Fall: IEC 제품 외형 인터페이스 Bypass Port 동작표시 LED 동작 환경 전력관리 기능 Switching Features 25

26 Managed Industrial 1G/2.5G L2 1Core Bypass Switch 제품 주요 사양 산업용 스위치: ETK-4000B-N842D Managed Industrial L2, Non PoE, 1Core Bypass Port Ethernet Switch 8 x 10/100/1000M UTP Port, 4 x SFP (100M x 4 or 1.25G x 4 or, 1.25G x G x 2) 1 Core Bypass (LC/UPC), Ring Protocol, Din rail, 방진기능:IP40지원,동작온도:-40~85 Power Block(+24VDC) 전원 이중화 직류 전원 공급 장치: NDR / SMPS-75WD-24V: Din rail / SMPS-75W-24V (Wall Type) 정격전력:75W, 24V,0~3.2A,공기냉각,과부하,과전압보호,자동복구, AC 110~220V Free Voltage +24VDC Din rail Type 직류전원장치 스위치 전면 제품 특징 Industrial Managed L2 switch 1 Bypass Port 스위치 후면 ETK-4000B-N842D 산업용 스위치는 30Gbps Switching Fabric 성능을 보유한 Gigabit L2 Bypass Ethernet 스위치로 -40 ~ 85 에서 운용할 수 있으며, +24VDC 전원 이중화로 안정성을 높였습니다. Ethernet Redundancy Protocol 지원으로, 이중화된 Ring 구성이 가능하며, 광 신호 전송 중 전원 다운/광 케이블 단선 등의 문제 발생시 자동감지 및 보호 기능으로, Bypass Port를 통해서 광 신호를 우회시켜 네 트워크에 작동에 영향을 주지 않고 안정적으로 통신을 할 수 있습니다 Support to G.8032 ERPS Ring Protection ETK-4000B-N842D는 ITU-T의 G.8032 ERPS(Ethernet Ring Protection Switching) 기능을 지원함으로, 본 스위치로 Ring을 구성 할 경우, 장비나 선로에 장애가 발생시 50ms 이내에 자동적으로 복구하는 기능 을 제공합니다 (자체 HF-Ring은 15ms이내 복구) ETK-4000B-N842D는 Bypass 기능을 지원하며 Line형으로 네트워크를 구성 할 경우, 특정 장비에 장애가 발생 하더라도 네트워크는 정상 작동하며 장애 장비가 장애 복구 시 자동적으로 5ms 이내 복구하는 기능을 제공 합니다 Support to Intelligent Management ETK-4000B-N842D 는 관리자의 편의를 위해 Web Management, CLI, SNMP 등 다양한 USER 인터페이스를 제공하며 또한 CoS, QoS, Bandwidth/Storm Control 및 ACL 등 Advanced Traffic Management 기능을 제공합니다. HTTPS, RADIUS, TACACS+ 등 서버 기반의 인증 기능을 지원합니다 Gigabit Managed Switch ETK-4000B-N842D는 8개의 10/100/1000M UTP Port와 4개의 기가 비트 광 포트 및 1쌍의 Bypass Port를 제공하는 스위치로, 4개의 광 포트 중 2개는 2.5G SFP를 지원하여 트래픽을 효과적으로 관리 할 수 있으며 다양한 네트워크 환경에 응용 할 수 있으며 고온, 저온,고습 등 열악한 환경에서 사용 할 수 있습 니다 Support to Static Routing : 32개의 경로를 지정할 수 있는 STATIC ROUTING 기능을 제공하므로 특정 목적 지의 네트워크로 가는 경로를 관리자의 의도대로 정밀하게 제어할 수 있습니다. 산업용 L2 스위치 NMS 소프트웨어 제공 (옵션) 네트워크 운영자에게 Network의 동작 및 장애 상태를 실시간으로 감지하여 알려줌으로써 신속하게 장애 복구를 할 수 있도록 하는 NMS S/W를 제공 합니다. 26

27 제품 주요 사양 Redundancy Software Features Housing: Metal / Cooling: Fanless / Protection Class: IP40 Dimension: 78mm 197mm 105mm (W*H*D) / Weight: 1.0Kg Mounting: DIN-Rail (표준), Wall Mounting (Option) 8 Port 10/100/1000Base-T 4 Port SFP (100M *4 or 1.25G * 4 or 1.25G* G *2) 1 Pair Bypass Port Micro USB Console Port Optical interface: Simplex Single Mode Fiber LC/PC Wavelength: 1310nm/1550nm, Fiber Optic Cable: Single Mode Insertion loss: 0.8dB LEDs on Front Panel (R: Running, A: Alarm) Power LED: P1, P2 / Interface LED: Link Storage And Operating Temperature : -40 ~ +85 C Ambient Relative Humidity:5-95%(non-condensing) Power Input : Standard: +24VDC / Alarm output: Support Terminal Block: 7 pin 5.08mm-Spacing plug-in terminal block Power Consumption: 15W / Overload Protection: Support Reverse Protection: Support / Redundancy Protection: Support Support to VLAN / GVRP Support to Storm Control / Port flow control / Port speed limit Support to QoS, CoS, ToS / Diffserv mapping, SPQ/WRR queuing Support to 802.1Q VLAN & 802.1ad Q-in-Q provide Bridging Support to Static Routing(L3 Basic) Support to HF-Ring with the recovery time 15ms Support to STP / RSTP / MSTP / LACP / ITU-T G.8032 Ethernet Ring Protection Multicast Support to IGMP v1/v2/v3 Snooping 네트워크 보안 Support to HTTPs / SSHv2 / RADIUS / TACACS+ / IEEE802.1X 관리 및 유지보수 기능 Support to IPv6, CLI-Console, WEB Base, CISCO-LIKE CLI, TFTP, TELNET SSH, SSL, SNMPv1/v2/v3 / RMON / Multiport Port mirroring System Syslog / Micro USB Console Port / Rate Control IEEE 1588 Precision time Protocol (PTP) IP Management Support to DHCP Clint/Server, IGMP Snooping /Client / Relay Standard IEEE 802.3i 10Base-T / IEEE 802.3u 100Base-TX and 100Base-FX IEEE802.3ab 1000base-T / IEEE 802.3z 1000Base-X / IEEE 802.3x Flow control IEEE 802.1p QoS / CoS (Class of Service) Protocol for traffic prioritization IEEE 802.1Q VLAN / IEEE802.1X Network Authentication IEEE802.3ab LLDP(Link Layer Discovery Protocol) IEEE802.1d STP / IEEE802.1w RSTP / IEEE802.1s MSTP IEEE 802.1ad Stacked VLAN, Q-in-Q ITU-T G 8032 / Y.1344 ERPS(Ethernet Ring Protection Switch) Switch Properties Data Process : Store & Forward Protocol: CSMA/CD, IGMP v1v2v3 Snooping, TFTP, NTP, RMON Priority Queues: 8 / Number of VLANs: 4096 / VLAN ID: MAC Table: 8K / Packet Buffer: 4Mbit Switching Delay: <5μs / Throughput: 22.32Mpps / Switching fabric: 30G Rates: 1000Mb/s Port: 1,488,000pps, 100Mb/s :148,800pps, 10Mb/s : 14,880pps 2.5Gb/s: 2,976,000pps 산업 표준 EMI: FCC Part 15 Subpart B Class A, EN55022 Class A EMS: IEC (ESD) Level 3, IEC (RS) exceeds Level 3, IEC (EFT) Level 3;IEC (Surge) Level 3, IEC (CS) Level 2, IEC , IEC IEC Machinery: Vibration: IEC / Shock: IEC Free Fall: IEC 제품 외형 인터페이스 Bypass Port 동작표시 LED 동작 환경 전력관리 기능 Switching Features 27

28 Managed Industrial 1G/2.5G L2 1Core Bypass Switch 제품 주요 사양 산업용 스위치: ETK-4000B-N842A Managed Industrial L2, Non PoE, 1Core Bypass Port Ethernet Switch 8 x 10/100/1000M UTP Port, 4 x SFP (100M x 4 or 1.25G x 4 or, 1.25G x G x 2) 1Pair Bypass Port (1Core LC/PC), Din rail Bracket, Ring Protocol 지원, 방진기능:IP40 동작 온도: -40~85, 전원공급장치: 110~220VAC Free Voltage Dual Power Supply 내장 과부하, 과전압 보호, 자동복구기능 보유. AC전원 케이블 스위치 전면 제품 특징 Industrial Managed L2 switch with 1 Bypass Port 스위치 후면 ETK-4000B-N842A 산업용 스위치는 30Gbps Switching Fabric 성능을 보유한 Gigabit L2 Ethernet 스위치로 -40 ~ 85 에서 운용할 수 있으며, AC 110~220V 전원 이중화로 안정성을 높였습니다. Ethernet Redundancy Protocol 지원으로 이중화된 Ring 구성이 가능하며, 광 신호 전송 중 전원 다운, 광 케이블 단선 등의 문제 발생시 자동감지 및 보호 기능으로, Bypass Port를 통해서 광 신호를 우회 시켜 네트워크 작동에 영향을 주지 않고 안정적으로 통신을 할 수 있습니다 Support to G.8032 ERPS Ring Protection ETK-4000B-N842A는 ITU-T의 G.8032 ERPS(Ethernet Ring Protection Switching) 기능을 지원함으로, 본 스위치로 Ring을 구성 할 경우, 장비나 선로에 장애가 발생시 50ms 이내에 자동적으로 복구하는 기능 을 제공합니다 (자체 HF-Ring은 15ms이내 복구) ETK-4000B-N842A는 Bypass 기능을 지원하며 Line형으로 네트워크를 구성 할 경우, 특정 장비에 장애가 발생 하더라도 네트워크는 정상 작동하며 장애 장비가 장애 복구 시 자동적으로 5ms 이내 복구하는 기능을 제공합니다. Support to Intelligent Management ETK-4000B-N842A 는 관리자의 편의를 위해 Web Management, CLI, SNMP 등 다양한 USER 인터페이스를 제공하며 또한 CoS, QoS, Bandwidth/Storm Control 및 ACL 등 Advanced Traffic Management 기능을 제공합니다. HTTPS, RADIUS, TACACS+ 등 서버 기반의 인증 기능을 지원. Gigabit Managed Switch ETK-4000B-N842A는 8개의 10/100/1000M UTP Port와 4개의 기가비트 광 포트 및 1쌍의 Bypass Port를 제공하는 스위치로, 4개의 광 포트 중 2개는 2.5G SFP를 지원하여 트래픽을 효과적으로 관리 할 수 있 으며 다양한 네트워크 환경에 응용 할 수 있으며 고온, 저온,고습 등 열악한 환경에서 사용 할 수 있습니다 Support to Static Routing 32개의 경로를 지정할 수 있는 STATIC ROUTING 기능을 제공하므로 특정 목적지의 네트워크로 가는 경로 를 관리자의 의도대로 정밀하게 제어할 수 있습니다. 산업용 L2 스위치 NMS 소프트웨어 제공 (옵션) 네트워크 운영자에게 Network의 동작 및 장애 상태를 실시간으로 감지하여 알려줌으로써 신속하게 장애 복구를 할 수 있도록 하는 NMS S/W를 제공 합니다. 28

29 제품 주요 사양 Redundancy Software Features Housing: Metal / Cooling: Fanless / Protection Class: IP40 Dimension: 78mm 197mm 105mm (W*H*D) / Weight: 1.0Kg Mounting: DIN-Rail (표준), Wall Mounting (Option) 8 Port 10/100/1000Base-T 4 Port SFP (100M *4 or 1.25G * 4 or 1.25G* G *2) 1 Pair Bypass Port Micro USB Console Port Optical interface: Simplex Single Mode Fiber LC/PC Wavelength: 1310nm/1550nm, Fiber Optic Cable: Single Mode Insertion loss: 0.8dB LEDs on Front Panel (R: Running, A: Alarm) Power LED: P1, P2 / Interface LED: Link Storage And Operating Temperature : -40 ~ +85 C Ambient Relative Humidity:5-95%(non-condensing) Power Input : Standard: 220VAC / Alarm output: Support Terminal Block: 7 pin 5.08mm-Spacing plug-in terminal block Power Consumption: 15W / Overload Protection: Support Reverse Protection: Support / Redundancy Protection: Support Support to VLAN / GVRP Support to Storm Control / Port flow control / Port speed limit Support to QoS, CoS, ToS / Diffserv mapping, SPQ/WRR queuing Support to 802.1Q VLAN & 802.1ad Q-in-Q provide Bridging Support to Static Routing(L3 basic) Support to HF-Ring with the recovery time 15ms Support to STP / RSTP / MSTP / LACP / ITU-T G.8032 Ethernet Ring Protection Multicast Support to IGMP v1/v2/v3 Snooping 네트워크 보안 Support to HTTPs / SSHv2 / RADIUS / TACACS+ / IEEE802.1X 관리 및 유지보수 기능 Support to IPv6, CLI-Console, WEB Base, CISCO-LIKE CLI, TFTP, TELNET SSH, SSL, SNMPv1/v2/v3 / RMON / Multiport Port mirroring System Syslog / Micro USB Console Port / Rate Control IEEE 1588 Precision time Protocol (PTP) IP Management Support to DHCP Clint/Server, IGMP Snooping /Client / Relay Standard IEEE 802.3i 10Base-T / IEEE 802.3u 100Base-TX and 100Base-FX IEEE802.3ab 1000base-T / IEEE 802.3z 1000Base-X / IEEE 802.3x Flow control IEEE 802.1p QoS / CoS (Class of Service) Protocol for traffic prioritization IEEE 802.1Q VLAN / IEEE802.1X Network Authentication IEEE802.3ab LLDP(Link Layer Discovery Protocol) IEEE802.1d STP / IEEE802.1w RSTP / IEEE802.1s MSTP IEEE 802.1ad Stacked VLAN, Q-in-Q ITU-T G 8032 / Y.1344 ERPS(Ethernet Ring Protection Switch) Switch Properties Data Process : Store & Forward Protocol: CSMA/CD, IGMP v1v2v3 Snooping, TFTP, NTP, RMON Priority Queues: 8 / Number of VLANs: 4096 / VLAN ID: MAC Table: 8K / Packet Buffer: 4Mbit Switching Delay: <5μs / Throughput: 22.32Mpps / Switching fabric: 30G Rates: 1000Mb/s Port: 1,488,000pps, 100Mb/s :148,800pps, 10Mb/s : 14,880pps 2.5Gb/s: 2,976,000pps 산업 표준 EMI: FCC Part 15 Subpart B Class A, EN55022 Class A EMS: IEC (ESD) Level 3, IEC (RS) exceeds Level 3, IEC (EFT) Level 3;IEC (Surge) Level 3, IEC (CS) Level 2, IEC , IEC IEC Machinery: Vibration: IEC / Shock: IEC Free Fall: IEC 제품 외형 인터페이스 Bypass Port 동작표시 LED 동작 환경 전력관리 기능 Switching Features 29

30 Managed Industrial L2 Ethernet Switch 제품 주요 사양 산업용 스위치: ETK-4000B-P820D Managed Industrial L2, PoE, No Bypass (L3 Static Routing) Ethernet Switch 8 x 10/100/1000M UTP Port, PoE, 2 x SFP (100M x 2 or 1.25G x 2 or 2.5G x 2), Din rail Bracket Ring Protocol 지원, 방진기능: IP40지원, 동작 온도 : -40~85 전원공급: +48VDC 전원 이중화 직류전원공급장치:NDR / SMPS-240WD-48V(Din rail) / SMPS-240W-48V(Wall Type) 정격전력:240W,48~56V, 5A,공기냉각,과부하,과전압 보호,자동복구, AC 110~220V Free Voltage +48VDC 직류전원장치 스위치 전면 스위치 후면 제품 특징 Industrial Managed L2 switch ETK-4000B-P820D 산업용 스위치는 26Gbps Switching Fabric 성능을 보유한 Gigabit L2 Ethernet 스위치로 -40 ~ 85 에서 운용할 수 있으며, +48VDC 전원 이중화로 안정성을 높였습니다. Ethernet Redundancy Protocol 지원으로, 이중화된 Ring 구성이 가능합니다. Support to G.8032 ERPS Ring Protection ETK-4000B-P820D는 ITU-T의 G.8032 ERPS(Ethernet Ring Protection Switching) 기능을 지원함으로, 본 스위치로 Ring을 구성 할 경우, 장비나 선로에 장애가 발생시 50ms 이내에 자동적으로 복구하는 기능 을 제공합니다 (자체 HF-Ring은 15ms이내 복구) Support to Intelligent Management ETK-4000B-P820D 는 관리자의 편의를 위해 Web Management, CLI, SNMP 등 다양한 USER 인터페이스를 제공하며 또한 CoS, QoS, Bandwidth/Storm Control 및 ACL 등 Advanced Traffic Management 기능을 제공합니다. HTTPS, RADIUS, TACACS+ 등 서버 기반의 인증 기능을 지원합니다 Gigabit Managed Switch ETK-4000B-P820D는 PoE 기능을 지원하는 8개의 10/100/1000M UTP Port와 2개의 기가 비트 광 포트를 제공하는 스위치로, 2개의 포트는 2.5G SFP를 지원하여 트래픽을 효과적으로 관리 할 수 있으며 다양한 네트워크 환경에 응용 할 수 있으며 고온, 저온,고습 환경 및 먼지에 대한 보호 기능으로 열악한 환경하에 서 운영이 가능합니다 Support to Static Routing 32개의 경로를 지정할 수 있는 STATIC ROUTING 기능을 제공하므로 특정 목적지의 네트워크로 가는 경로 를 관리자의 의도대로 정밀하게 제어할 수 있습니다. 산업용 L2 스위치 NMS 소프트웨어 제공 (옵션) 네트워크 운영자에게 Network의 동작 및 장애 상태를 실시간으로 감지하여 알려줌으로써 신속하게 장애 복구를 할 수 있도록 하는 NMS S/W를 제공 합니다. 30

31 제품 주요 사양 제품 외형 Housing: Metal / Cooling: Fanless / Protection Class: IP40 Dimension: 78mm 197mm 105mm (W*H*D) / Weight: 1.0Kg Mounting: DIN-Rail (표준), Wall Mounting (Option) 인터페이스 8 Port 10/100/1000Base-T 2 Port SFP (100M*2 or 1.25G * 2 or 2.5G *2) Micro USB Console Port Redundancy Software Features LEDs on Front Panel (R: Running, A: Alarm) Power LED: P1, P2 / Interface LED: Link Storage And Operating Temperature : -40 ~ +85 C Ambient Relative Humidity:5-95%(non-condensing) Power Input : Standard: +48VDC / Alarm output: Support Terminal Block: 7 pin 5.08mm-Spacing plug-in terminal block Power Consumption: 15W / Overload Protection: Support Reverse Protection: Support / Redundancy Protection: Support Support to VLAN / GVRP Support to Storm Control / Port flow control / Port speed limit Support to QoS, CoS, ToS / Diffserv mapping, SPQ/WRR queuing Support to 802.1Q VLAN & 802.1ad Q-in-Q provide Bridging Support to Static Routing(L3 Basic) Support to HF-Ring with the recovery time 15ms Support to STP / RSTP / MSTP / LACP / ITU-T G.8032 Ethernet Ring Protection Multicast Support to IGMP v1/v2/v3 Snooping 네트워크 보안 Support to HTTPs / SSHv2 / RADIUS / TACACS+ / IEEE802.1X 관리 및 유지보수 기능 Support to IPv6, CLI-Console, WEB Base, CISCO-LIKE CLI, TFTP, TELNET SSH, SSL, SNMPv1/v2/v3 / RMON / Multiport Port mirroring System Syslog / Micro USB Console Port / Rate Control IEEE 1588 Precision time Protocol (PTP) IP Management Support to DHCP Clint/Server, IGMP Snooping /Client / Relay Standard IEEE 802.3i 10Base-T / IEEE 802.3u 100Base-TX and 100Base-FX IEEE802.3ab 1000base-T / IEEE 802.3z 1000Base-X / IEEE 802.3x Flow control IEEE 802.1p QoS / CoS (Class of Service) Protocol for traffic prioritization IEEE 802.1Q VLAN / IEEE802.1X Network Authentication IEEE802.3ab LLDP(Link Layer Discovery Protocol) IEEE802.1d STP / IEEE802.1w RSTP / IEEE802.1s MSTP IEEE 802.1ad Stacked VLAN, Q-in-Q ITU-T G 8032 / Y.1344 ERPS(Ethernet Ring Protection Switch) Switch Properties Data Process : Store & Forward Protocol: CSMA/CD, IGMP v1v2v3 Snooping, TFTP, NTP, RMON Priority Queues: 8 / Number of VLANs: 4096 / VLAN ID: MAC Table: 8K / Packet Buffer: 4Mbit Switching Delay: <5μs / Throughput: 19.3Mpps / Switching fabric: 26G Rates: 1000Mb/s Port: 1,488,000pps, 100Mb/s :148,800pps, 10Mb/s : 14,880pps 2.5Gb/s: 2,976,000pps 산업 표준 EMI: FCC Part 15 Subpart B Class A, EN55022 Class A EMS: IEC (ESD) Level 3, IEC (RS) exceeds Level 3, IEC (EFT) Level 3;IEC (Surge) Level 3, IEC (CS) Level 2, IEC , IEC IEC Machinery: Vibration: IEC / Shock: IEC Free Fall: IEC 동작표시 LED 동작 환경 전력관리 기능 Switching Features 31

32 Managed Industrial L2 Ethernet Switch 제품 주요 사양 산업용 스위치: ETK-4000B-N820D Managed Industrial L2 Non PoE, No Bypass (L3 Static Routing) Ethernet Switch 8 x 10/100/1000M UTP Port, 2 x SFP (100M x 2 or 1.25G x 2 or 2.5G x 2), Din rail Bracket Ring Protocol 지원, 방진기능: IP40지원, 동작 온도 : -40~85, 전원공급:+24VDC 전원 이중화 직류 전원 공급 장치: DR / SMPS-75WD-24V : Din rail / SMPS-75W-24 (Wall Type) 정격전력:75W,24~28V,0~3.2A,공기냉각,과부하,과전압보호,자동복구,:AC110~220V Free Voltage +24VDC 직류전원장치 스위치 전면 스위치 후면 제품 특징 Industrial Managed L2 switch ETK-4000B-N820D 산업용 스위치는 26Gbps Switching Fabric 성능을 보유한 Gigabit L2 Ethernet 스위치로 -40 ~ 85 에서 운용할 수 있으며, +24VDC 전원 이중화로 안정성을 높였습니다. Ethernet Redundancy Protocol 지원으로, 이중화된 Ring 구성이 가능합니다. Support to G.8032 ERPS Ring Protection ETK-4000B-N820D는 ITU-T의 G.8032 ERPS(Ethernet Ring Protection Switching) 기능을 지원함으로, 본 스위치로 Ring을 구성 할 경우, 장비나 선로에 장애가 발생시 50ms 이내에 자동적으로 복구하는 기능 을 제공합니다 (자체 HF-Ring은 15ms이내 복구) Support to Intelligent Management ETK-4000B-N820D 는 관리자의 편의를 위해 Web Management, CLI, SNMP 등 다양한 USER 인터페이스를 제공하며 또한 CoS, QoS, Bandwidth/Storm Control 및 ACL 등 Advanced Traffic Management 기능을 제공합니다. HTTPS, RADIUS, TACACS+ 등 서버 기반의 인증 기능을 지원합니다 Gigabit Managed Switch ETK-4000B-N820D는 8개의 10/100/1000M UTP Port와 2개의 기가 비트 광 포트를 제공하는 스위치로, 2개 의 포트는 2.5G SFP를 지원하여 트래픽을 효과적으로 관리 할 수 있으며 다양한 네트워크 환경에 응용 할 수 있으며 고온, 저온,고습 환경 및 먼지에 대한 보호 기능으로 열악한 환경하에서 운영이 가능합니다 Support to Static Routing 32개의 경로를 지정할 수 있는 STATIC ROUTING 기능을 제공하므로 특정 목적지의 네트워크로 가는 경로 를 관리자의 의도대로 정밀하게 제어할 수 있습니다. 산업용 L2 스위치 NMS 소프트웨어 제공 (옵션) 네트워크 운영자에게 Network의 동작 및 장애 상태를 실시간으로 감지하여 알려줌으로써 신속하게 장애 복구를 할 수 있도록 하는 NMS S/W를 제공 합니다. 30

33 제품 주요 사양 제품 외형 Housing: Metal / Cooling: Fanless / Protection Class: IP40 Dimension: 78mm 197mm 105mm (W*H*D) / Weight: 1.0Kg Mounting: DIN-Rail (표준), Wall Mounting (Option) 인터페이스 8 Port 10/100/1000Base-T 2 Port SFP (100M*2 or 1.25G * 2 or 2.5G *2) Micro USB Console Port Redundancy Software Features LEDs on Front Panel (R: Running, A: Alarm) Power LED: P1, P2 / Interface LED: Link Storage And Operating Temperature : -40 ~ +85 C Ambient Relative Humidity:5-95%(non-condensing) Power Input : Standard: +24VDC / Alarm output: Support Terminal Block: 7 pin 5.08mm-Spacing plug-in terminal block Power Consumption: 15W / Overload Protection: Support Reverse Protection: Support / Redundancy Protection: Support Support to VLAN / GVRP Support to Storm Control / Port flow control / Port speed limit Support to QoS, CoS, ToS / Diffserv mapping, SPQ/WRR queuing Support to 802.1Q VLAN & 802.1ad Q-in-Q provide Bridging Support to Static Routing(L3 Basic) Support to HF-Ring with the recovery time 15ms Support to STP / RSTP / MSTP / LACP / ITU-T G.8032 Ethernet Ring Protection Multicast Support to IGMP v1/v2/v3 Snooping 네트워크 보안 Support to HTTPs / SSHv2 / RADIUS / TACACS+ / IEEE802.1X 관리 및 유지보수 기능 Support to IPv6, CLI-Console, WEB Base, CISCO-LIKE CLI, TFTP, TELNET SSH, SSL, SNMPv1/v2/v3 / RMON / Multiport Port mirroring System Syslog / Micro USB Console Port / Rate Control IEEE 1588 Precision time Protocol (PTP) IP Management Support to DHCP Clint/Server, IGMP Snooping /Client / Relay Standard IEEE 802.3i 10Base-T / IEEE 802.3u 100Base-TX and 100Base-FX IEEE802.3ab 1000base-T / IEEE 802.3z 1000Base-X / IEEE 802.3x Flow control IEEE 802.1p QoS / CoS (Class of Service) Protocol for traffic prioritization IEEE 802.1Q VLAN / IEEE802.1X Network Authentication IEEE802.3ab LLDP(Link Layer Discovery Protocol) IEEE802.1d STP / IEEE802.1w RSTP / IEEE802.1s MSTP IEEE 802.1ad Stacked VLAN, Q-in-Q ITU-T G 8032 / Y.1344 ERPS(Ethernet Ring Protection Switch) Switch Properties Data Process : Store & Forward Protocol: CSMA/CD, IGMP v1v2v3 Snooping, TFTP, NTP, RMON Priority Queues: 8 / Number of VLANs: 4096 / VLAN ID: MAC Table: 8K / Packet Buffer: 4Mbit Switching Delay: <5μs / Throughput: 19.3Mpps / Switching fabric: 26G Rates: 1000Mb/s Port: 1,488,000pps, 100Mb/s :148,800pps, 10Mb/s : 14,880pps 2.5Gb/s: 2,976,000pps 산업 표준 EMI: FCC Part 15 Subpart B Class A, EN55022 Class A EMS: IEC (ESD) Level 3, IEC (RS) exceeds Level 3, IEC (EFT) Level 3;IEC (Surge) Level 3, IEC (CS) Level 2, IEC , IEC IEC Machinery: Vibration: IEC / Shock: IEC Free Fall: IEC 동작표시 LED 동작 환경 전력관리 기능 Switching Features 33

34 Managed Industrial L2 Ethernet Switch 제품 주요 사양 산업용 스위치: ETK-4000B-N820A Managed Industrial L2 Non PoE No Bypass (L3 Static Routing) Ethernet Switch 8 x 10/100/1000M UTP Port, 2 x SFP (100M x 2 or 1.25G x 2 or 2.5G x 2), Din rail Bracket Ring Protocol 지원, 방진기능: IP40지원, 동작 온도: -40~85, 전원 공급 AC110~220V Dual Power Supply 내장, 과부하, 과전압 보호, 자동복구기능 보유. AC전원 케이블 스위치 전면 스위치 후면 제품 특징 Industrial Managed L2 switch ETK-4000B-N820A 산업용 스위치는 26Gbps Switching Fabric 성능을 보유한 Gigabit L2 Ethernet 스위치로 -40 ~ 85 에서 운용할 수 있으며, AC 110~220V 전원 이중화로 안정성을 높였습니다. Ethernet Redundancy Protocol 지원으로 이중화된 Ring 구성이 가능합니다. Support to G.8032 ERPS Ring Protection ETK-4000B-N820A는 ITU-T의 G.8032 ERPS(Ethernet Ring Protection Switching) 기능을 지원함으로, 본 스위치로 Ring을 구성 할 경우, 장비나 선로에 장애가 발생시 50ms 이내에 자동적으로 복구하는 기능 을 제공합니다 (자체 HF-Ring은 15ms이내 복구) Support to Intelligent Management ETK-4000B-N820A 는 관리자의 편의를 위해 Web Management, CLI, SNMP 등 다양한 USER 인터페이스를 제공하며 또한 CoS, QoS, Bandwidth/Storm Control 및 ACL 등 Advanced Traffic Management 기능을 제공합니다. HTTPS, RADIUS, TACACS+ 등 서버 기반의 인증 기능을 지원. Gigabit Managed Switch ETK-4000B-N820A는 8개의 10/100/1000M UTP Port와 2개의 기가비트 광 포트를 제공하는 스위치로 2개의 광 포트는 2.5G SFP를 지원하여 트래픽을 효과적으로 관리 할 수 있으며 다양한 네트워크 환경에 응용 할 수 있으며 고온, 저온,고습 환경 및 먼지에 대한 보호 기능으로 열악한 환경하에서 운영이 가능. Support to Static Routing 32개의 경로를 지정할 수 있는 STATIC ROUTING 기능을 제공하므로 특정 목적지의 네트워크로 가는 경로 를 관리자의 의도대로 정밀하게 제어할 수 있습니다. 산업용 L2 스위치 NMS 소프트웨어 제공 (옵션) 네트워크 운영자에게 Network의 동작 및 장애 상태를 실시간으로 감지하여 알려줌으로써 신속하게 장애 복구를 할 수 있도록 하는 NMS S/W를 제공 합니다. 34

Ruckus ICX GBE 1GbE 10GbE 12 10km POE AP CCTV PoE Ruckus ICX 7250 (pay as you grow). (GbE), 8 10GbE 12 (1GbE 576 ). Ruckus ICX 7250 PoE/PoE+.

Ruckus ICX GBE 1GbE 10GbE 12 10km POE AP CCTV PoE Ruckus ICX 7250 (pay as you grow). (GbE), 8 10GbE 12 (1GbE 576 ). Ruckus ICX 7250 PoE/PoE+. 8 10GBE 1GbE 10GbE 12 10km POE AP CCTV PoE Ruckus ICX 7250 (pay as you grow). (GbE), 8 10GbE 12(1GbE 576 ). PoE/PoE+... 1GbE 10GbE.,.,. /, VDI( ). PoE PoE+ 1GbE 1/10GbE / 24 48 10/100/1000Mbps ( 1 ) IP.

More information

TTA Verified : HomeGateway :, : (NEtwork Testing Team)

TTA Verified : HomeGateway :, : (NEtwork Testing Team) TTA Verified : HomeGateway :, : (NEtwork Testing Team) : TTA-V-N-05-006-CC11 TTA Verified :2006 6 27 : 01 : 2005 7 18 : 2/15 00 01 2005 7 18 2006 6 27 6 7 9 Ethernet (VLAN, QoS, FTP ) (, ) : TTA-V-N-05-006-CC11

More information

7124SX_Data Sheet

7124SX_Data Sheet 7124SX 10G SFP 1RU 24 1/10GbE 480 Gigabit 3 6 L2 L3 500 L2 L3 1GE 10GE Arista 7124SX 2/3/4 10 Gigabit. 1RU 24 1/10GbE Arista 7124SX 500. RK 10GbE SFP+ GbE SFP Gigabit 10 Gigabit. Arista EOS, ZTP(Zero Touch

More information

슬라이드 1

슬라이드 1 Cisco-Linksys Switch Products 아이넷뱅크박정은 2006.1 1 Un-Managed Switch 1. 10/100 Switch-DeskTop (SD205/SD208/SD216) 2. 10/100 Switch-RACK (SR216/SR224/SR224G) 3. 10/100 Switch-19 Rack Size (EF3116/EF3124/EF31SC)

More information

PowerPoint 프레젠테이션

PowerPoint 프레젠테이션 1x1 Fiber Tap Visibility, comfortable, stealth and security 개요 Features 네트워크다운타임없이 24/7 모니터링을가능하게해줌 모든레이어로부터의모든트래픽 ( 에러포함 ) 을통과시켜포괄적인 troubleshooting 을할수있음 메이저제조사의모니터링디바이스 프로토콜분석기, RMON Probe, IDS/IPS

More information

고성능 ASIC 기반 엔진을 탑재한 차세대 보안 솔루션 Ethernet Switches Ubigate ies4200 Series ies4200 Series 보안 스위치 ies4200 Series 특장점 ies4200 Series 보안스위치는 기존의 네트워크 관문에 집중

고성능 ASIC 기반 엔진을 탑재한 차세대 보안 솔루션 Ethernet Switches Ubigate ies4200 Series ies4200 Series 보안 스위치 ies4200 Series 특장점 ies4200 Series 보안스위치는 기존의 네트워크 관문에 집중 Samsung Ethernet Switches Ubigate ies Series Samsung Enterprise Network Solutions www.samsungenterprise.co.kr 고성능 ASIC 기반 엔진을 탑재한 차세대 보안 솔루션 Ethernet Switches Ubigate ies4200 Series ies4200 Series 보안 스위치

More information

FTTH 기술발표

FTTH 기술발표 2 3 xdsl /UTP FTTH / 2002 2005 2010 2 Mbps 6 Mbps 100Mbps * 10 Mbps 45Mbps 155Mbps FTTO / FTTD / Digital (DBS) 53Mbps/4km LMDS ADSL : Asymmetric Digital Subscriber Line HDSL : High speed Digital Subscriber

More information

gs2210 series.pdf

gs2210 series.pdf XGS2210/GS2210 Series 8/24/28/48/52-port GbE L2 Switch Overview XGS2210/ GS2210 시리즈는 CLI기반의 8/24/28/48/52 port GbE L2(PoE) 스위치로 GbE RJ-45와SFP포트를지원하는기가비트스위치입니다. 제품구성은PoE를지원하는GS2210-8HP/GS2210-24HP/GS2210-24LP/GS2210-48HP와

More information

<4D F736F F F696E74202D F4E20C1A6C7B0BCD2B0B3C0DAB7E15FBCF6C1A4BABB2E BC8A3C8AF20B8F0B5E55D>

<4D F736F F F696E74202D F4E20C1A6C7B0BCD2B0B3C0DAB7E15FBCF6C1A4BABB2E BC8A3C8AF20B8F0B5E55D> HOC GEPON 소개자료 목차 1.PON 소개 2.GEPON 2-1OLT 2-2 ONU 2 1. PON 소개 PON 일반소개 PON의구조는크게센터에위치하는 OLT장비와원격지에설치되는 ONU 장비로구성된다. OLT와 ONU 중간에광을분기하는스플리터가들어가며스플리터의분기에따라서 1:2, 1:4, 1:8, 1:16, 1:32의구조를갖는다. Splitter OLT

More information

Coriolis.hwp

Coriolis.hwp MCM Series 주요특징 MaxiFlo TM (맥시플로) 코리올리스 (Coriolis) 질량유량계 MCM 시리즈는 최고의 정밀도를 자랑하며 슬러리를 포함한 액체, 혼합 액체등의 질량 유량, 밀도, 온도, 보정된 부피 유량을 측정할 수 있는 질량 유량계 이다. 단일 액체 또는 2가지 혼합액체를 측정할 수 있으며, 강한 노이즈 에도 견디는 면역성, 높은 정밀도,

More information

% 100 50 1 * Lightwave 98/4, M. Shariff, Cisco systems Inc. 1996 1997 1998 1999 2000 2001 = * APT Office Home MAN POP POP MAN APT Office Home Access Network Access Network?! DWDM OXC MPLS, MPLamdaS ADSL

More information

() Aloha Netowrk ether(,, )network Ehternet, DEC, ( DIX(DEC, Intel, Xerox) IEEE(, ) 5 9,, (Xerox) (Bob Metcalfe), (, ) A

() Aloha Netowrk ether(,, )network Ehternet, DEC, ( DIX(DEC, Intel, Xerox) IEEE(,   ) 5 9,, (Xerox) (Bob Metcalfe), (, ) A 1 2 3 4 1960 1973 () Aloha Netowrk ether(,, )network Ehternet, DEC, ( DIX(DEC, Intel, Xerox) IEEE(, http://wwwieeeorg/, ) 5 9,, (Xerox) (Bob Metcalfe), (, ) Aloha Network 1960 / IEEE CSMA/CD IEEE () 30

More information

OmniSwitch ppt [호환 모드]

OmniSwitch ppt [호환 모드] 1.1 OmniSwitch 6850 OmniSwitch 6850 Overview L3 Gig Ethernet Stack 24 / 48 ports 10/100/1000 POE 및 non-poe 모델 24 ports SFP Fiber 모델 (100FX 또는 Gig transceivers) 2 x 10G Uplink 제공 2 x 10G full-duplex 의 Stacking

More information

xgs-4528f.ai

xgs-4528f.ai 24-port GbE L3 Swtich 24-port Combo(SFP/RJ45) 2 x 10GbE CX4 ports Expansion module(10g XFP or CX4) 144Gbps Switching capacity IP Routing Static routing Policy-based routing(pbr) VRRP IP port moving RIP,

More information

Microsoft PowerPoint - 2.Catalyst Switch Intrastructure Protection_이충용_V1 0.ppt [호환 모드]

Microsoft PowerPoint - 2.Catalyst Switch Intrastructure Protection_이충용_V1 0.ppt [호환 모드] Catalyst Switch Infrastructure Protection Cisco Systems Korea SE 이충용 (choolee@cisco.com) Overview DoS (Denial of Service) 공격대상 - Server Resource - Network Resource - Network devices (Routers, Firewalls

More information

1.LAN의 특징과 각종 방식

1.LAN의 특징과 각종 방식 0 Chapter 1. LAN I. LAN 1. - - - - Switching - 2. LAN - (Topology) - (Cable) - - 2.1 1) / LAN - - (point to point) 2) LAN - 3) LAN - 2.2 1) Bound - - (Twisted Pair) - (Coaxial cable) - (Fiber Optics) 1

More information

TEL:02)861-1175, FAX:02)861-1176 , REAL-TIME,, ( ) CUSTOMER. CUSTOMER REAL TIME CUSTOMER D/B RF HANDY TEMINAL RF, RF (AP-3020) : LAN-S (N-1000) : LAN (TCP/IP) RF (PPT-2740) : RF (,RF ) : (CL-201)

More information

2005 2004 2003 2002 2001 2000 Security Surveillance Ubiquitous Infra Internet Infra Telematics Security Surveillance Telematics Internet Infra Solutions Camera Site (NETWORK) Monitoring & Control

More information

7050T_Datasheet_08_06_12

7050T_Datasheet_08_06_12 7050T-64: 48x1/10GbE & 4x40GbE QSFP+ 7050T-52: 48x1/10GbE & 4x10GbE SFP+ 7050T-36: 32x1/10GbE & 4x10GbE SFP+ 100Mb/1Gb/10GBASE-T 1.28 terabit 9 6 L2 L3 7W 1+1 N+1 128K MAC 16K IPv4 32K IPv4 8K IPv6 8K

More information

7050S_Datasheet_8_07_12

7050S_Datasheet_8_07_12 7050 Series 10/40G 7050S-64: 48x1/10GbE 4x40GbE 7050S-52: 52x1/10GbE 1.28 terabits per second 960 million packets per second L2 L3 800ns ~ 1.2us 12W 1+1 N+1 128K MAC 16K IPv4 32K IPv4 8K IPv6 8K M 9MB

More information

歯Cablexpert제안서.PDF

歯Cablexpert제안서.PDF : CableXpert TM TEL:02-576-0471 / E-mail : lab@dakos.net 1. (CableXpert TM :CME1100 ) (PSTN) 100,. (CableXpert TM ).,,.... : : 324-1 2 : 02-576-0471 : 02-576-0474 : (E-mail : jangpo@dakos.net) 3. 1) S/W

More information

untitled

untitled Huvitz Digital Microscope HDS-5800 Dimensions unit : mm Huvitz Digital Microscope HDS-5800 HDS-MC HDS-SS50 HDS-TS50 SUPERIORITY Smart Optical Solutions for You! Huvitz Digital Microscope HDS-5800 Contents

More information

PowerPoint Presentation

PowerPoint Presentation NETGEAR PoE/PoE+ Switch June 5, 2018 NETGEAR Switch Portfolio Full Managed Smart Managed Plus Click & Easy-Mount Smart Managed Plus - Light L2 Features - Web-Managed Insight Managed Smart Cloud - Easy

More information

5. Kapitel URE neu

5. Kapitel URE neu URE Fuses for Semiconductor Protection European-British Standard Standards: IEC 60 269-4 BS 88-4 Class: ar Voltage ratings: AC 240 V AC 700 V Current ratings: 5 A 900 A Features / Benefits High interrupting

More information

전자교탁 사양서.hwp

전자교탁 사양서.hwp 사 양 서 품 목 단 위 수량 SYSTEM CONSOLE EA 32 - 사용자에 따른 타블렛 모니터 저소음 전동 각도 조절기능이 내장된 교탁 - 교탁 상/하부 별도의 조립이 필요 없는 일체형(All in One type) CONSOLE - 상판에 리미트 센서를 부착하여 장비 및 시스템의 안정성 강화 - 금형으로 제작, 슬림하고 견고하며 마감이 깔끔한 미래지향적

More information

안전을 위한 주의사항 제품을 올바르게 사용하여 위험이나 재산상의 피해를 미리 막기 위한 내용이므로 반드시 지켜 주시기 바랍니다. 2 경고 설치 관련 지시사항을 위반했을 때 심각한 상해가 발생하거나 사망에 이를 가능성이 있는 경우 설치하기 전에 반드시 본 기기의 전원을

안전을 위한 주의사항 제품을 올바르게 사용하여 위험이나 재산상의 피해를 미리 막기 위한 내용이므로 반드시 지켜 주시기 바랍니다. 2 경고 설치 관련 지시사항을 위반했을 때 심각한 상해가 발생하거나 사망에 이를 가능성이 있는 경우 설치하기 전에 반드시 본 기기의 전원을 Digital Video Recorder 간편설명서 XD3316 안전을 위한 주의사항 제품을 올바르게 사용하여 위험이나 재산상의 피해를 미리 막기 위한 내용이므로 반드시 지켜 주시기 바랍니다. 2 경고 설치 관련 지시사항을 위반했을 때 심각한 상해가 발생하거나 사망에 이를 가능성이 있는 경우 설치하기 전에 반드시 본 기기의 전원을 차단하고, 전원 플러그를 동시에

More information

untitled

untitled CLEBO PM-10S / PM-10HT Megapixel Speed Dome Camera 2/39 3/39 4/39 5/39 6/39 7/39 8/39 ON ON 1 2 3 4 5 6 7 8 9/39 ON ON 1 2 3 4 10/39 ON ON 1 2 3 4 11/39 12/39 13/39 14/39 15/39 Meg gapixel Speed Dome Camera

More information

DC Link Application DC Link capacitor can be universally used for the assembly of low inductance DC buffer circuits and DC filtering, smoothing. They

DC Link Application DC Link capacitor can be universally used for the assembly of low inductance DC buffer circuits and DC filtering, smoothing. They DC Link Capacitor DC Link Application DC Link capacitor can be universally used for the assembly of low inductance DC buffer circuits and DC filtering, smoothing. They are Metallized polypropylene (SH-type)

More information

Microsoft PowerPoint - User Manual-100 - 20150521.pptx

Microsoft PowerPoint - User Manual-100 - 20150521.pptx CIC-100 사용 설명서 (User Manual) 나의 커뮤니티, 보는 이야기 TocView [모델명 : CIC-100] 주의사항 매뉴얼의 내용은 서비스 향상을 위하여 개별 사용자의 사전 동의 또는 별도의 공지 없이 변경될 수 있습니다. 사용자의 인터넷 환경에 따라 제품 성능 및 기능의 제작 또는 사용이 불가능할 수 있습니다. 본 제품의 이용 중 장애에 의하여

More information

XGS4600_serise_ver3

XGS4600_serise_ver3 Port Density 24 x GbE RJ-45 port (XGS4600-32) 24 x SFP ports (XGS4600-32F) 4 x GbE combo (RJ-45/SFP)ports 4 x 10GbE SFP+ Slot XGS4600 Series 28-port GbE L3 Managed Switch Overview XGS4600 시리즈는 32포트기가비트

More information

gs1900.ai

gs1900.ai 스마트관리형스위치주요 L2 기능지원 Web GUI 방식의쉬운기능설정및관리 IEEE 802.3at PoE Plus 적용 - 포트당 30W - 최대 170W PoE 지원 (GS1900-24HP/48HP) - 최대 77W PoE 지원 (GS1900-10HP) - 최대 70W PoE 지원 (GS1900-8HP) 퀵설정마법사지원 Start up VLAN QoS Link

More information

VZ94-한글매뉴얼

VZ94-한글매뉴얼 KOREAN / KOREAN VZ9-4 #1 #2 #3 IR #4 #5 #6 #7 ( ) #8 #9 #10 #11 IR ( ) #12 #13 IR ( ) #14 ( ) #15 #16 #17 (#6) #18 HDMI #19 RGB #20 HDMI-1 #21 HDMI-2 #22 #23 #24 USB (WLAN ) #25 USB ( ) #26 USB ( ) #27

More information

Turbine Digital Flowmeter SEMI U+ 특징 PVC, PTFE, P.P, PVDF 등 다양한 재질 Size, 유량, Connection별 주문제작 정밀성, 내화학성이 우수 4~20mA, Alarm, 통신(RS485) 등 출력 제품과 Controll

Turbine Digital Flowmeter SEMI U+ 특징 PVC, PTFE, P.P, PVDF 등 다양한 재질 Size, 유량, Connection별 주문제작 정밀성, 내화학성이 우수 4~20mA, Alarm, 통신(RS485) 등 출력 제품과 Controll Turbine Digital Flowmeter SEMI U+ 특징 PVC, PTFE, P.P, PVDF 등 다양한 재질 Size, 유량, Connection별 주문제작 정밀성, 내화학성이 우수 4~20mA, Alarm, 통신(RS485) 등 출력 제품과 Controller의 장착 및 사용이 편리 Specification (사양) 적용유체 : 액체 (D.I or

More information

- 2 -

- 2 - - 1 - - 2 - 전기자동차충전기기술기준 ( 안 ) - 3 - 1 3 1-1 3 1-2 (AC) 26 1-3 (DC) 31 2 37 3 40-4 - 1 14, 10,, 2 3. 1-1 1. (scope) 600 V (IEC 60038) 500 V. (EV : Electric Vehicle) (PHEV : Plug-in Hybrid EV).. 2. (normative

More information

<목 차 > 제 1장 일반사항 4 I.사업의 개요 4 1.사업명 4 2.사업의 목적 4 3.입찰 방식 4 4.입찰 참가 자격 4 5.사업 및 계약 기간 5 6.추진 일정 6 7.사업 범위 및 내용 6 II.사업시행 주요 요건 8 1.사업시행 조건 8 2.계약보증 9 3

<목 차 > 제 1장 일반사항 4 I.사업의 개요 4 1.사업명 4 2.사업의 목적 4 3.입찰 방식 4 4.입찰 참가 자격 4 5.사업 및 계약 기간 5 6.추진 일정 6 7.사업 범위 및 내용 6 II.사업시행 주요 요건 8 1.사업시행 조건 8 2.계약보증 9 3 열차운행정보 승무원 확인시스템 구축 제 안 요 청 서 2014.6. 제 1장 일반사항 4 I.사업의 개요 4 1.사업명 4 2.사업의 목적 4 3.입찰 방식 4 4.입찰 참가 자격 4 5.사업 및 계약 기간 5 6.추진 일정 6 7.사업 범위 및 내용 6 II.사업시행 주요 요건 8 1.사업시행 조건 8 2.계약보증 9 3.시운전 및 하자보증 10

More information

1. Features IR-Compact non-contact infrared thermometer measures the infrared wavelength emitted from the target spot and converts it to standard curr

1. Features IR-Compact non-contact infrared thermometer measures the infrared wavelength emitted from the target spot and converts it to standard curr Non-Contact Infrared Temperature I R - Compact Sensor / Transmitter GASDNA co.,ltd C-910C, Bupyeong Woolim Lion s Valley, #425, Cheongcheon-Dong, Bupyeong-Gu, Incheon, Korea TEL: +82-32-623-7507 FAX: +82-32-623-7510

More information

ZoneFlex AP (1) : ZoneFlex T300 ZoneFlex T301s ZoneFlex T301n ZoneFlex T300e AP ( ), 180., 1"~4". 4". (1) : (1) : (2) M8 ( ) (4) SAE32,

ZoneFlex AP (1) : ZoneFlex T300 ZoneFlex T301s ZoneFlex T301n ZoneFlex T300e AP ( ), 180., 1~4. 4. (1) : (1) : (2) M8 ( ) (4) SAE32, ZoneFlex AP 902-0120-0000 ZoneFlex R720 ZoneFlex R710 ZoneFlex R700* ZoneFlex R600* ZoneFlex R610* ZoneFlex R500* ZoneFlex R510* ZoneFlex R310 * AP AP,,. ZoneFlex R710. (1) (2) #6 902-0100-0000 ZoneFlex

More information

ez-md+_manual01

ez-md+_manual01 ez-md+ HDMI/SDI Cross Converter with Audio Mux/Demux Operation manual REVISION NUMBER: 1.0.0 DISTRIBUTION DATE: NOVEMBER. 2018 저작권 알림 Copyright 2006~2018 LUMANTEK Co., Ltd. All Rights Reserved 루먼텍 사에서

More information

Microsoft Word - zfs-storage-family_ko.doc

Microsoft Word - zfs-storage-family_ko.doc 데이터 관리 용이성과 스토리지 효율성을 하나로 결합 주요 기능 및 이점 획기적인 가격 대비 성능과 혁신적인 단순성을 하나로 결합 특징 문제를 손쉽게 발견 및 수정하고 성능을 최적화할 수 있는 탁월한 관리 툴 포괄적이고 통합된 데이터 서비스 및 프로토콜 액티브-액티브 클러스터 옵션 데이터 압축 및 인라인 중복 제거 지속적인 데이터 증가로 인해 오늘날 IT 인프라는

More information

Network seminar.key

Network seminar.key Intro to Network .. 2 4 ( ) ( ). ?!? ~! This is ~ ( ) /,,,???? TCP/IP Application Layer Transfer Layer Internet Layer Data Link Layer Physical Layer OSI 7 TCP/IP Application Layer Transfer Layer 3 4 Network

More information

gs1920

gs1920 스마트관리형스위치주요 L2 기능지원 Web GUI 방식의쉬운기능설정및관리 IEEE 802.3at PoE Plus 적용포트당 30W, 최대 375W PoE 전원지원 네트워크보호기능 Loop Guard CPU Protection IP source Guard(IPSG) Dual image & configuration files ZyXEL One Network(ZON)

More information

TOPAZ into SCADA Something Different. So, Special. 유비쿼터스 세상을 추구하는 - 신영전자통신

TOPAZ into SCADA Something Different. So, Special. 유비쿼터스 세상을 추구하는 - 신영전자통신 TOPAZ into SCADA Something Different. So, Special. 유비쿼터스 세상을 추구하는 - 신영전자통신 유비쿼터스세상을추구하는 - 신영전자통신 토파즈의필요성 Market Trends & Opportunity 인터넷기반의업무서비스지원및보안위협에대처하고장애없는최상급의안정적인 IT 인프라요구됩니다. 년간예산절감에따른초기투자비 CAPEX

More information

歯이시홍).PDF

歯이시홍).PDF cwseo@netsgo.com Si-Hong Lee duckling@sktelecom.com SK Telecom Platform - 1 - 1. Digital AMPS CDMA (IS-95 A/B) CDMA (cdma2000-1x) IMT-2000 (IS-95 C) ( ) ( ) ( ) ( ) - 2 - 2. QoS Market QoS Coverage C/D

More information

OfficeServ 솔루션 OfficeServ 솔루션 OfficeServ는 삼성전자의 기업형 IP 솔루션으로서 음성과 데이터, 유선과 무선이 융합된 미래 오피스형 솔루션입니다. OfficeServ 7400/7200 삼성전자가 다년간 쌓아 온 기간망 사업 경험 및 모바일

OfficeServ 솔루션 OfficeServ 솔루션 OfficeServ는 삼성전자의 기업형 IP 솔루션으로서 음성과 데이터, 유선과 무선이 융합된 미래 오피스형 솔루션입니다. OfficeServ 7400/7200 삼성전자가 다년간 쌓아 온 기간망 사업 경험 및 모바일 Unlimited Connectivity, Enterprise Convergence Unlimited Connectivity, Enterprise Convergence SMB IP 중소용량 IP-PBX SYSTEM Solution 네트워크사업부 Enterprise 영업팀 경기도 수원시 영통구 삼성로 129 E-mail : jh1.park@samsung.com

More information

7782 WI-FI AP (5GHz/2.4GHz) RF 6dB / 15dB 4bB, af/at PoE(Power over Ethernet) 802.3af/at VAC GPS,, 2~4 IP 900Mbps (450Mbps/ ) 32 BSSID, QoS ** Q

7782 WI-FI AP (5GHz/2.4GHz) RF 6dB / 15dB 4bB, af/at PoE(Power over Ethernet) 802.3af/at VAC GPS,, 2~4 IP 900Mbps (450Mbps/ ) 32 BSSID, QoS ** Q Wi-Fi 802.11n Wi-Fi 3x3:3 MIMO(N 2x2:2). 3G, Wi-Fi. ChannelFly RF,. AC,. IP-67. Wi-Fi ZoneDirector, SCG 200 FlexMaster Wi-Fi AP. SCG 200 ZoneFlex 7782. Wi-Fi BeamFlex+ 6dB 15dB AP 500. PD-MRC( - ) PD-MRC

More information

T100MD+

T100MD+ User s Manual 100% ) ( x b a a + 1 RX+ TX+ DTR GND TX+ RX+ DTR GND RX+ TX+ DTR GND DSR RX+ TX+ DTR GND DSR [ DCE TYPE ] [ DCE TYPE ] RS232 Format Baud 1 T100MD+

More information

Microsoft Power Point 2002

Microsoft Power Point 2002 PLC전기공압제어 강의 노트 제 7 회차 PLC 하드웨어의 구조 - 1 - 학습목표 1. PLC 하드웨어의 4가지 구성요소를 설명할 수 있다. 2. PLC 형명을 보고 PLC를 구분할 수 있다. 3. PLC 배선형태에 따라 입력기기와 출력기기를 구분할 수 있다. Lesson. PLC 하드웨어의 구조 PLC 하드웨어에 대한 이해의 필요성 PLC 하드웨어의 구성

More information

Microsoft Word - SRA-Series Manual.doc

Microsoft Word - SRA-Series Manual.doc 사 용 설 명 서 SRA Series Professional Power Amplifier MODEL No : SRA-500, SRA-900, SRA-1300 차 례 차 례 ---------------------------------------------------------------------- 2 안전지침 / 주의사항 -----------------------------------------------------------

More information

<BACEBDBAC5CD20BAEAB7CEBCC52D A2DC3D6C1BE2D312D E6169>

<BACEBDBAC5CD20BAEAB7CEBCC52D A2DC3D6C1BE2D312D E6169> DOOCH PUMP Intelligent pressure boosting system 5Hz BOOSTER PUMP SYSTEM Water supply system Pressure boosting system Irrigation system Water treatment system Industrial plants 두크펌프 www.doochpump.com CONTENTS

More information

Table of Contents FTTH GE-PON 솔루션 >> OLT >> U9264H... 3 소개... 3 망구성... 4 특징... 4 기능... 5 사양... 7 주문정보... 8

Table of Contents FTTH GE-PON 솔루션 >> OLT >> U9264H... 3 소개... 3 망구성... 4 특징... 4 기능... 5 사양... 7 주문정보... 8 Seamless Network Service Solution PON Product Datasheet U9264H ubiquoss Inc. 본사 : 경기도성남시분당구판교로 255 번길 68 유비쿼스 B/D TEL: 070-4865-0500, FAX: 031-8017-1184 sales@ubiquoss.com www.ubiquoss.com Copyright 2015

More information

1. GigE Camera Interface를 위한 최소 PC 사양 CPU : Intel Core 2 Duo, 2.4GHz이상 RAM : 2GB 이상 LANcard : Intel PRO/1000xT 이상 VGA : PCI x 16, VRAM DDR2 RAM 256MB

1. GigE Camera Interface를 위한 최소 PC 사양 CPU : Intel Core 2 Duo, 2.4GHz이상 RAM : 2GB 이상 LANcard : Intel PRO/1000xT 이상 VGA : PCI x 16, VRAM DDR2 RAM 256MB Revision 1.0 Date 11th Nov. 2013 Description Established. Page Page 1 of 9 1. GigE Camera Interface를 위한 최소 PC 사양 CPU : Intel Core 2 Duo, 2.4GHz이상 RAM : 2GB 이상 LANcard : Intel PRO/1000xT 이상 VGA : PCI x

More information

Unlimited Connectivity, Samsung Enterprise Convergence 대용량 IP-PBX Solution Unlimited Connectivity, Samsung Enterprise Convergence 네트워크사업부 Enterprise B

Unlimited Connectivity, Samsung Enterprise Convergence 대용량 IP-PBX Solution Unlimited Connectivity, Samsung Enterprise Convergence 네트워크사업부 Enterprise B Unlimited Connectivity, Enterprise Convergence 대용량 IP-PBX Solution Unlimited Connectivity, Enterprise Convergence 네트워크사업부 Enterprise BM 경기도수원시영통구삼성로 129 E-mail : snowy.lee@samsung.com 서비스문의 : 1577-3366

More information

135 S P STATUS PoE SPEED DUPLEX STACK MODE POWER STACK 7210 POWER STATUS

135 S P STATUS PoE SPEED DUPLEX STACK MODE POWER STACK 7210 POWER STATUS 135 S1500-24P 2 4 6 8 10 12 14 16 18 20 22 24 STATUS PoE SPEED DUPLEX STACK MODE 1 3 5 7 9 11 13 15 17 19 21 23 0 1 2 3 POWER STACK 7210 POWER STATUS PEERED MENU ENTER 데이터시트 아루바 S1500 모빌리티액세스스위치 아루바네트웍스의

More information

Cisco Catalyst 3750-E Series 스위치 Bulletin StackWise Plus 가포함된 Cisco Catalyst 3750-E Series 스위치는엔터프라이즈급의스택형와이어링클로짓스위치로서안전한컨버전스애플리케이션의배치를용이하게할뿐만아니라진화하는네

Cisco Catalyst 3750-E Series 스위치 Bulletin StackWise Plus 가포함된 Cisco Catalyst 3750-E Series 스위치는엔터프라이즈급의스택형와이어링클로짓스위치로서안전한컨버전스애플리케이션의배치를용이하게할뿐만아니라진화하는네 Cisco Catalyst 3750-E Series 스위치 Bulletin StackWise Plus 가포함된 Cisco Catalyst 3750-E Series 스위치는엔터프라이즈급의스택형와이어링클로짓스위치로서안전한컨버전스애플리케이션의배치를용이하게할뿐만아니라진화하는네트워크및애플리케이션요구사항에따른투자를최대한보호합니다. Cisco Catalyst 3750-E

More information

TiFRONT Security Switch L2 / L3 스위칭 네트워크접근제어 유해트래픽만선별차단 효율적인통합보안관리

TiFRONT Security Switch L2 / L3 스위칭 네트워크접근제어 유해트래픽만선별차단 효율적인통합보안관리 TiFRONT Security Switch L2 / L3 스위칭 네트워크접근제어 유해트래픽만선별차단 효율적인통합보안관리 TiFRONT Security Switch TiFRONT 보안스위치 TiFRONT 보안스위치는네트워크구성의기본요소인스위치와사용자단말에특화된내부네트워크보안기능을결합한차세대스위치입니다. 사용자단말에서발생하는각종유해트래픽만을자동으로선별하여차단하고계정정보탈취및통화도청등과같은악의적인공격을막습니다.

More information

歯메뉴얼v2.04.doc

歯메뉴얼v2.04.doc 1 SV - ih.. 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 - - - 23 24 R S T G U V W P1 P2 N R S T G U V W P1 P2 N R S T G U V W P1 P2 N 25 26 DC REACTOR(OPTION) DB UNIT(OPTION) 3 φ 220/440 V 50/60

More information

TAE YOUNG Electronics 당사는 1987년 설립되어 직류전원장치를 전문 제조하는 업체로서, 국내 인터넷서비스 업체인 두루넷과 하나로텔레콤 등을 거쳐 현재의 SK브로드밴드, LG유플러스의 전원아답터 공급업체로서 오랜 시간 함께 성장하였습니다. 또한 자체 브

TAE YOUNG Electronics 당사는 1987년 설립되어 직류전원장치를 전문 제조하는 업체로서, 국내 인터넷서비스 업체인 두루넷과 하나로텔레콤 등을 거쳐 현재의 SK브로드밴드, LG유플러스의 전원아답터 공급업체로서 오랜 시간 함께 성장하였습니다. 또한 자체 브 www.adaptor21.com Global Power Supply Leader TAE YOUNG AC. ADAPTOR. SMPS TAE YOUNG Electronics 당사는 1987년 설립되어 직류전원장치를 전문 제조하는 업체로서, 국내 인터넷서비스 업체인 두루넷과 하나로텔레콤 등을 거쳐 현재의 SK브로드밴드, LG유플러스의 전원아답터 공급업체로서 오랜

More information

歯동작원리.PDF

歯동작원리.PDF UPS System 1 UPS UPS, Converter,,, Maintenance Bypass Switch 5 DC Converter DC, DC, Rectifier / Charger Converter DC, /, Filter Trouble, Maintenance Bypass Switch UPS Trouble, 2 UPS 1) UPS UPS 100W KVA

More information

SLA QoS

SLA QoS SLA QoS 2002. 12. 13 Email: really97@postech.ac.kr QoS QoS SLA POS-SLMS (-Service Level Monitoring System) SLA (Service Level Agreement) SLA SLA TM Forum SLA QoS QoS SLA SLA QoS QoS SLA POS-SLMS ( Service

More information

歯AG-MX70P한글매뉴얼.PDF

歯AG-MX70P한글매뉴얼.PDF 120 V AC, 50/60 Hz : 52 W (with no optional accessories installed), indicates safety information. 70 W (with all optional accessories installed) : : (WxHxD) : : 41 F to 104 F (+ 5 C to + 40 C) Less than

More information

7 LAMPS For use on a flat surface of a type 1 enclosure File No. E Pilot Lamp File No. E Type Classification Diagram - BULB Type Part Mate

7 LAMPS For use on a flat surface of a type 1 enclosure File No. E Pilot Lamp File No. E Type Classification Diagram - BULB Type Part Mate 7 LAMPS For use on a flat surface of a type 1 enclosure File No. E242380 Pilot Lamp File No. E242380 Type Classification Diagram - BULB Type Part Materials 226 YongSung Electric Co., Ltd. LAMPS

More information

LAN케이블링

LAN케이블링 LAN Page1 1. Defacto De Jure (De jure ), (De Facto ),. (De Jure) : ISO ITU.,. ISO ITU KS, KICS, TTA. (De Facto) :. MS, IPX, IBM SNA. (Forum) :.. IETF, W3C, ATM ATM. Page2 2. American National Standards

More information

KR

KR 34410A 34411A 6.5 1 2 4 13 18 19 34410A 34411A 6.5. DMM 12. DMM 34401A. DC AC DMM. 34410A 6.5 DMM 10 000 5.5 1 000 6.5 30 PPM 1 DC LAN USB & GPIB DCV ACV DCI ACI 2/4-50 k 34411A 6.5 DMM 34410A 50 000 100

More information

P8724XG-Brochure_Kor-v1.doc

P8724XG-Brochure_Kor-v1.doc Premier 8724XG 유비쿼스 Premier 8724XG 스위치는 IP-TV 및 TPS 서비스를고려하여 HW적 IPv6 와라우팅, 멀티캐스팅, QoS기능등을대폭강화한집선용스위치로 Metro-IP 망및이더넷기반네트워크의가입자접속구간에적용되어 Layer 2/3/4계층에서초고속광대역멀티미디어서비스를제공하는고성능스위치입니다. Premier 8724XG 스위치는트래픽집선분배스위치로부터초고속

More information

Ultimate High Performance Audio tx-usb Operating Instructions Rev : 1.0

Ultimate High Performance Audio tx-usb Operating Instructions Rev : 1.0 Ultimate High Performance Audio tx-usb Operating Instructions Rev : 1.0 www.sotm-audio.com 주의사항및 A/S 정보 사용자주의사항 반드시본사용설명서를모두읽은후제품을사용하십시오. 제품의분해, 개조등을하지마십시오. 제품에진동, 충격을가하지마십시오. 손상되거나피복이벗겨진 cable은사용하지마십시오.

More information

TiFRONT Security Switch L2 / L3 스위칭 네트워크접근제어 유해트래픽만선별차단 효율적인통합보안관리

TiFRONT Security Switch L2 / L3 스위칭 네트워크접근제어 유해트래픽만선별차단 효율적인통합보안관리 TiFRONT Security Switch L2 / L3 스위칭 네트워크접근제어 유해트래픽만선별차단 효율적인통합보안관리 TiFRONT Security Switch TiFRONT 보안스위치 TiFRONT 보안스위치는네트워크구성의기본요소인스위치와사용자단말에특화된내부네트워크보안기능을결합한차세대스위치입니다. 사용자단말에서발생하는각종유해트래픽만을자동으로선별하여차단하고계정정보탈취및통화도청등과같은악의적인공격을막습니다.

More information

Smart-UPS On-Line 230 V UPS apc.com/kr

Smart-UPS On-Line 230 V UPS apc.com/kr Smart-UPS On-Line 230 V UPS apc.com/kr apc.com/kr 2 UPS Smart-UPS On-Line, /,. Smart-UPS On-Line / 5kVA~10kVA. 6kVA, 8kVA 10kVA. Smart-UPS On-Line. PowerChute Network Shutdown,. Smart-UPS On- Line,,,.

More information

Microsoft PowerPoint - eSlim SV5-2510 [080116]

Microsoft PowerPoint - eSlim SV5-2510 [080116] Innovation for Total Solution Provider!! eslim SV5-2510 Opteron Server 2008. 03 ESLIM KOREA INC. 1. 제 품 개 요 eslim SV5-2510 Server Quad-Core and Dual-Core Opteron 2000 Series 6 internal HDD bays for SAS

More information

USER Manual

USER Manual KOR V1.3 AltPLC 6637 Quick Guide Web: www.altsoft.kr E-mail: altsoft@altsoft.kr Tel: 02-547-2344 Features Processor - Intel i7-3610qe 2.3GHz - Intel i5-3610me 2.7GHz Memory - 1 x DDR3 1066/1333MHz SODIMM,

More information

cam_IG.book

cam_IG.book 설치 안내서 AXIS P3301 고정형 돔 네트워크 카메라 AXIS P3301-V 고정형 돔 네트워크 카메라 한국어 AXIS P3304 고정형 돔 네트워크 카메라 AXIS P3304-V 고정형 돔 네트워크 카메라 문서 정보 본 문서에는 사용자 네트워크에 AXIS P3301/P3304 고정형 돔 네트워크 카메라를 설치하는 방법에 대 한 지침이 포함되어 있습니다.

More information

KDTÁ¾ÇÕ-2-07/03

KDTÁ¾ÇÕ-2-07/03 CIMON-PLC CIMON-SCADA CIMON-TOUCH CIMON-Xpanel www.kdtsys.com CIMON-SCADA Total Solution for Industrial Automation Industrial Automatic Software sphere 16 Total Solution For Industrial Automation SCADA

More information

CONTENTS FLOATLSS LEVEL SWITCH 04 ELECTRODE HOLDER 22 AUTOMATIC LEVEL SWITCH 24 FLOAT LEVEL SWITCH 31 MINI FLOAT LEVEL SWITCH 38 TIMING RELAY 51 SUPER MICOM TIMER 53 48 (SM)MICOM TIMER SERIES 57 MICOM

More information

S P-4x10G PoE

S P-4x10G PoE 135 2 4 6 8 10 12 14 16 18 20 22 1 3 5 7 9 11 13 15 17 19 21 23 S2500-48P-4x10G PoE 24 26 28 30 32 34 36 38 40 42 44 46 25 27 29 31 33 35 37 39 41 43 45 47 POWER STATUS STACK 0 1 2 3 MENU ENTER 7210 POWER

More information

기능 및 장점 표 1은 Cisco Catalyst 6500-E Series 샤시의 주요 기능과 이점에 대해 설명합니다. 표 1. 주요 기능 및 이점 Feature Scalability Benefit 3, 4, 6, 9, 9-V and 13-slot modular cha

기능 및 장점 표 1은 Cisco Catalyst 6500-E Series 샤시의 주요 기능과 이점에 대해 설명합니다. 표 1. 주요 기능 및 이점 Feature Scalability Benefit 3, 4, 6, 9, 9-V and 13-slot modular cha 데이터 시트 Cisco Catalyst 6500-E Series 샤시 제품 개요 시스코는 시스템 대역폭 용량 초당 최대 2테라비트와 슬롯당 대역폭 80Gbps를 제공하는 Cisco Catalyst 6500 Enhanced Series 샤시(6500-E Series)를 출시했습니다. VSS를 위해 구성된 시스템에서 6500-E Series 샤시는 4Tbps 의

More information

APOGEE Insight_KR_Base_3P11

APOGEE Insight_KR_Base_3P11 Technical Specification Sheet Document No. 149-332P25 September, 2010 Insight 3.11 Base Workstation 그림 1. Insight Base 메인메뉴 Insight Base Insight Insight Base, Insight Base Insight Base Insight Windows

More information

歯A1.1함진호.ppt

歯A1.1함진호.ppt The Overall Architecture of Optical Internet ETRI ? ? Payload Header Header Recognition Processing, and Generation A 1 setup 1 1 C B 2 2 2 Delay line Synchronizer New Header D - : 20Km/sec, 1µsec200 A

More information

D101351X0KR_May17

D101351X0KR_May17 646 Fisher 646... 1... 1... 3... 4... 4... 4... 5... 5... 5... 6... 7... 7... 7... 9... 9... 9... 9... 10... 11... 12... 12... 13... 15... 15... 15 1. Fisher 646 Fisher 646,,..,,,, 646,.,,.. W6783 1 www.fisher.com

More information

SEMI U+

SEMI U+ SSENP FLOW METER 에스에스이엔피 경기도화성시새강 1 길 43 TEL : 031)8015-2452 FAX : 031)935-0452 E-mail : kelvin@ssenp.co.kr Turbine Digital Flow meter 특징 SEMI U+ PVC, PTFE, P.P, PVDF 등다양한재질 정밀성, 내화학성우수 4~20 ma, Alarm,

More information

( Full Automatic Printer ) 작용업종 : Tube Light ( 형광등 1.2m / 2.4m) 가로등조명. 인테리어산업용조명 Loader 1.2m Stencil Solder LED LD812V Reflow 8 to 10 Hot Air Convecti

( Full Automatic Printer ) 작용업종 : Tube Light ( 형광등 1.2m / 2.4m) 가로등조명. 인테리어산업용조명 Loader 1.2m Stencil Solder LED LD812V Reflow 8 to 10 Hot Air Convecti Autotronik-SMT GmbH LED Assembly 위한장비구성도 Printer LED Pick & Place Reflow V-Cutting Model 1 1.2m Tube LED " 양산 " 장비 Full Vision Auto Printer 1.2m LED Pick & Place LED Reflow 10 Zone LED Multi V-Cutting

More information

Time To Think D-Link D-Link FMC Solution Guide Book

Time To Think D-Link D-Link FMC Solution Guide Book Time To Think D-Link D-Link FMC Solution Guide Book Time To Think D-Link D-Link FMC Solution 당신에게필요한진정한유무선통합솔루션을지금만나보시기바랍니다. FMC( 유무선통합 ) SOLUTION 예산맞춤설계서비스 (www.d-link.co.kr) 고객님의예산에최적화된 FMC 솔루션을, 1:1

More information

1217 WebTrafMon II

1217 WebTrafMon II (1/28) (2/28) (10 Mbps ) Video, Audio. (3/28) 10 ~ 15 ( : telnet, ftp ),, (4/28) UDP/TCP (5/28) centralized environment packet header information analysis network traffic data, capture presentation network

More information

Microsoft Word - USB복사기.doc

Microsoft Word - USB복사기.doc Version: SD/USB 80130 Content Index 1. Introduction 1.1 제품개요------------------------------------------------------------P.02 1.2 모델별 제품사양-------------------------------------------------------P.04 2. Function

More information

Microsoft Word - FS_ZigBee_Manual_V1.3.docx

Microsoft Word - FS_ZigBee_Manual_V1.3.docx FirmSYS Zigbee etworks Kit User Manual FS-ZK500 Rev. 2008/05 Page 1 of 26 Version 1.3 목 차 1. 제품구성... 3 2. 개요... 4 3. 네트워크 설명... 5 4. 호스트/노드 설명... 6 네트워크 구성... 6 5. 모바일 태그 설명... 8 6. 프로토콜 설명... 9 프로토콜 목록...

More information

ez-shv manual

ez-shv manual ez-shv+ SDI to HDMI Converter with Display and Scaler Operation manual REVISION NUMBER: 1.0.0 DISTRIBUTION DATE: NOVEMBER. 2018 저작권 알림 Copyright 2006~2018 LUMANTEK Co., Ltd. All Rights Reserved 루먼텍 사에서

More information

Microsoft Word - JAVS_UDT-1_상세_메뉴얼.doc

Microsoft Word - JAVS_UDT-1_상세_메뉴얼.doc UDT-1 TRANSPORTER 한글 상세 제품 설명서 SoundPrime. 저작권 본 저작권은 Soundprime 이 소유하고 있습니다. Soundprime 의 허가 없이 정보 검색 시스템상에서 복사, 수정, 전달, 번역, 저장을 금지하며, 컴퓨터언어나 다른 어떠한 언어로도 수정될 수 없습니다. 또한 다른 형식이나 전기적, 기계적, 자기적, 광학적, 화학적,

More information

Microsoft PowerPoint - eSlim SV5-2410 [20080402]

Microsoft PowerPoint - eSlim SV5-2410 [20080402] Innovation for Total Solution Provider!! eslim SV5-2410 Opteron Server 2008. 3 ESLIM KOREA INC. 1. 제 품 개 요 eslim SV5-2410 Server Quad-Core and Dual-Core Opteron 2000 Series Max. 4 Disk Bays for SAS and

More information

1. 회사소개 및 연혁 - 회사소개 회사소개 회사연혁 대표이사: 한종열 관계사 설립일 : 03. 11. 05 자본금 : 11.5억원 인 원 : 18명 에스오넷 미도리야전기코리 아 미도리야전기(일본) 2008 2007 Cisco Premier Partner 취득 Cisco Physical Security ATP 취득(진행) 서울시 강남구 도심방범CCTV관제센터

More information

Microsoft Word - Installation and User Manual_CMD V2.2_.doc

Microsoft Word - Installation and User Manual_CMD V2.2_.doc CARDMATIC CMD INSTALLATION MANUAL 씨앤에이씨스템(C&A SYSTEM Co., Ltd.) 본사 : 서울특별시 용산구 신계동 24-1(금양빌딩 2층) TEL. (02)718-2386( 代 ) FAX. (02) 701-2966 공장/연구소 : 경기도 고양시 일산동구 백석동 1141-2 유니테크빌 324호 TEL. (031)907-1386

More information

Microsoft Word - ZIO-AP1500N-Manual.doc

Microsoft Word - ZIO-AP1500N-Manual.doc 목 차 사용자 설명서 1 장 제품 소개 ------------------------------ 1 2 장 제품 내용물 ---------------------------- 2 3 장 AP 연결 설정 방법 ------------------------ 3 4 장 동작 방식별 설정 방법 --------------------- 7 (1) 엑세스 포인트 모드 -----------------------

More information

D103198X0KR_Jul18 Korean

D103198X0KR_Jul18 Korean Fisher i2p-100... 1... 1... 2... 2... 2... 5... 7... 7... 8... 9... 10... 10... 11... 12... 12... 12... 12... 14... 14... 16... 16... 17... 18 1. Fisher i2p-100 W8710... 19... 20 Fisher i2p 100,, ( 1 )..,,,,

More information

Microsoft PowerPoint - LG RouterÁ¦Ç°(02-03)

Microsoft PowerPoint - LG RouterÁ¦Ç°(02-03) Cost Effective LA & WA Internetworking LR300F 0 데이콤 대량 공급 제품 LR300F 제품은 제품의 안정성 및 성능이 검증된 중소형 라우터로서, 사용자별로 실시간 대역폭(Bandwidth) 사용 정도를 모니터 할 수 있으며 향후 IP v6 지원이 가능한 제품입니다. 2개의 WA Port와 개의 Fast Ethernet Port

More information

KDTÁ¾ÇÕ-1-07/03

KDTÁ¾ÇÕ-1-07/03 CIMON-PLC CIMON-SCADA CIMON-TOUCH CIMON-Xpanel www.kdtsys.com CIMON-PLC Total Solution for Industrial Automation PLC (Program Logic Controller) Sphere 8 Total Solution For Industrial Automation PLC Application

More information

D102005X0KR_May18

D102005X0KR_May18 846 Fisher 846 -... 2... 2... 2... 5... 6... 7... 8... 8... 10... 14... 14... 15... 15... 16 :,... 18 :,... 18 :,... 19 4 ~ 12mA... 19 12 ~ 20mA... 19 :,... 20 :,... 20 :,... 21 4 ~ 12mA... 21 12 ~ 20mA...

More information

Microsoft PowerPoint - GSS108E_GSS108EPP_GSS116E_DS_kor_ pptx

Microsoft PowerPoint - GSS108E_GSS108EPP_GSS116E_DS_kor_ pptx 케이블및포트를원하는곳어디든지설치가능 오늘날의네트워크는유선혹은무선으로계속증가하는장비와연결되어야만합니다. 특히유선장비가계속증가함에따라귀하가원하는위치및장소에네트워크포트를쉽고간편하면서깔끔하게배치및설치하는것은그리쉬운일이아닙니다. NETGEAR ProSAFE Click Switch 들은유연한 Virtually Anywhere 클릭마운팅시스템을이용함으로써보다혁신적이고사려깊은하드웨어디자인을통해이문제를해결하고있습니다.

More information

X-VA-MT3809G-MT3810G-kor

X-VA-MT3809G-MT3810G-kor www.brooksinstrument.com 기본적인 설명 진행전 반드시 읽어 주십시오. Brooks 는 많은 국내 및 국제 기준을 충족하기 위해 제품을 설계, 생산 및 테스트를 합니다. 이 제품이 제대로 설치, 운영되고 그 들이 정상 사양 내에서 작동하도록 지속적인 유지보수가 필요합니다. Brooks Instrument 제품을 설치, 사용 및 유지보수 시

More information

PERFORMANCE AND CAPACITY Features Maximum campus AP licenses Maximum remote AP licenses Maximum concurrent us

PERFORMANCE AND CAPACITY Features Maximum campus AP licenses Maximum remote AP licenses Maximum concurrent us 데이터시트 아루바 7000 시리즈클라우드서비스컨트롤러 브랜치오피스올 - 와이어리스업무환경구현 아루바 7000 시리즈클라우드서비스컨트롤러 (Aruba 7000 Series Cloud Services Controller) 는브랜치오피스에서클라우드서비스를최적화하고엔터프라이즈애플리케이션을보호합니다. 이와동시에구성, 관리, 암호화, 애플리케이션가시성을제공하여네트워크서비스의안정적인지원을보장합니다.

More information

Vertical Probe Card Technology Pin Technology 1) Probe Pin Testable Pitch:03 (Matrix) Minimum Pin Length:2.67 High Speed Test Application:Test Socket

Vertical Probe Card Technology Pin Technology 1) Probe Pin Testable Pitch:03 (Matrix) Minimum Pin Length:2.67 High Speed Test Application:Test Socket Vertical Probe Card for Wafer Test Vertical Probe Card Technology Pin Technology 1) Probe Pin Testable Pitch:03 (Matrix) Minimum Pin Length:2.67 High Speed Test Application:Test Socket Life Time: 500000

More information

GLHPS-D

GLHPS-D Digital Hot Plate & Stirrer GLHPS-D 글로벌랩의 제품을 구입하여 주셔서 감사드립니다. 제품을 사용하시기 전에 안전을 위한 준비사항 을 읽고 올바르게 사용해 주십시오. 이 사용설명서는 제품을 직접 사용하시는 분에게 보내어지도록 하여 주십시오. 사용 전 주의 사항 제품을 올바르게 사용하여 위험이나 재산상의 피해를 막기 위한 내용으로 반드시

More information

TiFRONT Cloud Security Switch for CCTV CCTV 전용 TiFRONT 클라우드보안스위치 IP 카메라설치예정이십니까? 전용스위치로보안을높이세요. CCTV 망보안, IP 카메라비밀번호관리 파이오링크의 CCTV 전용 TiFRONT 클라우드보안스위

TiFRONT Cloud Security Switch for CCTV CCTV 전용 TiFRONT 클라우드보안스위치 IP 카메라설치예정이십니까? 전용스위치로보안을높이세요. CCTV 망보안, IP 카메라비밀번호관리 파이오링크의 CCTV 전용 TiFRONT 클라우드보안스위 CCTV 전용 클라우드보안스위치 IP 카메라비밀번호관리 CCTV 망보안 CC 인증획득 TiFRONT Cloud Security Switch for CCTV CCTV 전용 TiFRONT 클라우드보안스위치 IP 카메라설치예정이십니까? 전용스위치로보안을높이세요. CCTV 망보안, IP 카메라비밀번호관리 파이오링크의 CCTV 전용 TiFRONT 클라우드보안스위치는

More information

hwp

hwp 100% Concentration rate (%) 95% 90% 85% 80% 0.5 1.5 2.5 3.5 4.5 5.5 6.5 7.5 Time (min) Control box of RS485 Driving part Control trigger Control box of driving car Diaphragm Lens of camera Illumination

More information