D X0KR

Size: px
Start display at page:

Download "D X0KR"

Transcription

1 DVC6200 Fisher FIELDVUE DVC6200 HC, AD, PD, ODV DD ,, HART Rosemount 333 HART Tri-Loop HART W9713 / / / HART HART 5 / HART

2 DVC6200 () PST , (ODV) I/P (PWB) , DVC PWB I/P , DVC HART A HART DVC B

3 1,, DVC6200,, DVC6200 (D103556X012). QR. DVC6200 (D103556X012).,,,.. Fisher ValveLink ValveLink Mobile,. ValveLink ValveLink.,,,, DVC6200,.,,..., : > > (2-1-1) B. DVC6200 ( ) -. HART DVC6200.., ( ). 3

4 1 1. Fisher FIELDVUE DVC Fisher GX FIELDVUE DVC6200 W9616 X ValveLink AMS Suite: DVC6200.,,, HART. DVC (2) HC AD PD ODV x x X X x x x x x x x x x x x x, x x x ( ) x x x (3) x x x - x x x x x x X X X X / (1) 1. Fisher D351146X HC = HART Communicating, AD = Advanced Diagnostics, PD = Performance Diagnostics, ODV = Optimized Digital Valve. 3 ValveLink. X 4

5 1 2.. DVC DVC Bulletin 62.1:DVC Fisher FIELDVUE DVC2000 (D103415X012) Bulletin 62.1:DVC Fisher FIELDVUE DVC2000 (D103543X012) Fisher FIELDVUE DVC6200 (D103556X012) FIELDVUE (D103262X012) Smart HART (HIM) FIELDVUE (D103263X012) Smart Wireless THUM HART (HIM) FIELDVUE (D103469X012) HART (D103265X012) HART - Fisher FIELDVUE DVC6200 (D103639X012) FIELDVUE HART Tri Loop HART to Analog (D103267X012) Lock in Last (D103261X012) Fisher HF340 (D102796X012) AMS Trex Device Communicator User Guide ValveLink Fisher.com. 5

6 1 2. DVC6200 DVC6215 : Fisher 657/667 GX Fisher 2 wall mounting() DVC6205 DVC6200 DVC6215 IEC , IEC , VDI/VDE 3845 NAMUR. HART 5 HART 7 -to- : 4-20mA DC,, 9.5VDC, HART 10VDC : 4.0mA : 3.5mA : 30VDC : 10mA 11~30VDC (1) : 0.3bar(5psig) : 10.0bar(145psig) :. ISA ppm (w/w) (v/v).. ISO : 7 : 3 : 3 10 C, : 0.4bar(6psig) : 9.5bar(140psig) :, (2)(3) 1.4bar(20psig) : 0.38 normal m 3 /hr(14scfh) 5.5bar(80psig) : 1.3 normal m 3 /hr(49scfh) 1.4bar(20psig) : normal m 3 /hr(2.1scfh) 5.5bar(80psig) : normal m 3 /hr(6.9scfh) (2)(3) 1.4bar(20psig) : 10.0 normal m 3 /hr(375scfh) 5.5bar(80psig) : 29.5 normal m 3 /hr(1100scfh) (1)(4) -40~85 C (-40~185 F) -52~85 C (-62~185 F) - (fluorosilicone elastomers) -52~125 C (-62~257 F) - (5) : ±0.50% EN : EN Class A ISM : 1, Class A - c4á8d - 6

7 1 2. () ANSI/ISA-S ISA ohm (impedance). 20mA 10V. IEC CSA -,, Division 2, FM -,,, ATEX -, FISCO,, Type n IECEx -,, Type n CSA - 4X, IP66 FM - Type 4X, IP66 ATEX - IP66 IECEx - IP66 /, - CSA, FM, ATEX IECEx(I/O ) - () CUTR - (,, ) INMETRO - National Institute of Metrology, Quality and Technology( )( ) KGS - () NEPSI - () PESO CCOE - Petroleum and Explosives Safety Organisation - Chief Controller of Explosives( - )() TIIS - () /. : 67CFR 1/4 NPT : 1/4 NPT : 3/8 : 3/8 NPT : 1/2 NPT M20 (6) ( ) : 6.5mm(0.25) : 606mm(23.875) ( ) : 45 : 90 DVC6200 : 3.5kg(7.7lbs) : 8.6kg(19lbs) DVC6205: 4.1kg(9lbs) DVC6215: 1.4kg(3.1lbs), : A03600 () () : : () () - (7) (8) 4 20mA (9) : 4 20mA, :8 30VDC : 1% NAMUR NE43. (> 22.5mA) (< 3.6mA). ' '. - c4á8d - 7

8 1 2. () () (9) : 1, Off :0mA() On : 1A :30VDC : 2% Fisher.com. SEP Fisher Controls International LLC PED 2014/68/EU 4 3. (SEP), PED CE. CE. ANSI/ISA /. 2. Normal m 3 /hour - 0 C bar normal. Scfh - 60 F 14.7psia bar(20psig) ; - 5.5bar(80psig). 4. CUTR Ex d -53 C (-63.4 F) mm(0.75) M20 ATEX. 7. Quad O 6scfh 16 C(60 F) 3.7bar(53psi), DVC ~22AWG, 4. 91m(300). 15m(50). 91m EMC - (1) (ESD) IEC kV, 8kV A 10V/m 80~1000MHz(80% 1kHz AM )3V/m EM IEC ~2000MHz(80% 1kHz AM ) 1V/m A 2000~2700MHz(80% 1kHz AM ) IEC /60Hz 30A/m A IEC kV A I/O / IEC kV B RF IEC Vrms 150kHz ~ 80MHz A + / - 1%. 1. A =. B =. DVC6200. Emerson Automation Solutions, : : education@emerson.com emerson.com/fishervalvetraining 8

9 2 22 DVC6200. HART HART HART. HART HART. I/O ( 2 1 ). HART HART. HART HART.. HART PROVOX, RS3 DeltaV Emerson HART HART DCS I/O I/O HART 4-20mA + HART Tx Tx A DVC VDC... 9

10 2 2., THUM intrinsic safety barrier.. = [ ( )] - [ (HART )] - [ ] - [ x ] 10V DC HF340 HART 305m(1000) Belden 9501 Honeywell TDC2000. = [18.5(21.05mA)] - [2.3] - [48ohm amp] = [18.5] - [2.3] - [1.01] = 15.19v 2 2. THUM ( ) + - HART ( ) intrinsic safety barrier( ) R + - : - ( ) v(21.05mA) - 2.3v(HF300 ) - Intrinsic safety barrier( ) x v(121ohm x amp) - Smart Wireless THUM ( ) 2 - x v(305m(1000) Belden ohmx amp) = 3 = 15.19v - safety barrier(2.55v) : 1.., intrinsic safety barrier( ) THUM 2.25v 3.5mA 1.2v 25mA.. 8.0~9.5v. 10

11 2 1. (1) pf/ft (1) pf/m (2) Ohms/ft (2) Ohms/m BS5308/1, 0.5 sq mm BS5308/1, 1.0 sq mm BS5308/2, 1.5sq mm BS5308/2, 1.5sq mm BS5308/2, 0.75 sq mm BS5308/2, 1.5 sq mm BELDEN 8303, 22 awg BELDEN 8441, 22 awg BELDEN 8767, 22 awg BELDEN 8777, 22 awg BELDEN 9501, 24 awg BELDEN 9680, 24 awg BELDEN 9729, 24 awg BELDEN 9773, 18 awg BELDEN 9829, 24 awg BELDEN 9873, 20 awg k (POTENTIOMETER) A k (POTENTIOMETER)

12 ODV DVC6200. DVC ,000pF.,. :. 100,000pF...,. - 18AWG, : 1KHz: 26 pf/ft Nom.- 20 Deg. DC C: 5.96Ohms/1000ft - UL 200V RMS(PLTC, CMG),150V RMS(ITC) = 100,000pF/(26pF/ft) = 3846ft - 18AWG, : : 29Ohms Nom. :.15μH/ft Nom. 1KHz: 26 pf/ft Nom.- 1KHz 97 pf/ft- = 100,000pF/(97pF/ft) = 1030ft 1mA 5V... HART.. (ft) = [160,000 - C (pf)] [C (pf/ft)] (m) = [160,000 - C (pf)] [C (pf/m)] 160,000 = HART RC HART 65μs FIELDVUE. C = HART 12

13 C = ( 2 1 ) C 50, 000pF Belden pF/ft Foxboro I/A (1988). (ft) = [160,000-50,000pF] [50pF/ft] = 2200ft HART... Rosemount 333 HART Tri-Loop HART- DVC6200 Rosemount 333 HART Tri-Loop HART-,, 4-20mA. HART Tri-Loop mA HART Tri Loop HART HART Tri-Loop HART Tri-Loop HART Tri-Loop HART Tri Loop. HART Tri Loop DIN HART Tri-Loop HART Tri-Loop?. HART Tri-Loop HART Tri-Loop 1? HART Tri-Loop () HART Tri-Loop 2 3 E

14 HART Tri-Loop 333 HART Tri-Loop Burst Command 3. HART Tri-Loop HART-. HART Tri-Loop 4-20mA. 1 (), 2 ( ), 3 ( ) 4 ( ). DVC6200 HART Tri-Loop. I/O > > > ( ) HC, AD, PD ( ) ODV I/O > > > ( ) HC, AD, PD ( ) ODV. /PV/SV/TV/QV. HART I/O > > > HART ( ) HC, AD, PD ( ) ODV I/O > > > HART ( ) HC, AD, PD ( ) ODV HART. 1 (PV). 2 (SV), 3 (TV) 4 (QV). DVC6200 Tri-Loop. ( ) A B A B. 14

15 3 > (2-1).,,..., (). - -, ,,,, (1) 4mA 20mA (ma) 0 3 Cmd 3() A-B 125% -25% / 99.46% / 0.50% () (Integrator) (integral) 0%/sec 0%/sec / 0.26% -- 15

16 3 1. () (1) 5% psi (2) DVC bar, kpa Kg/cm 2 > > (2-2-1) DVC mA.. Out Of Service In Service. DVC ( ). > > (2-2-2). HART - 8. HART. HART.. HART (HART Universal 7 )

17 - 16. HART point-to-point 0.. HART 7 0 ~ 63, HART 5 0 ~ psi, bar, kpa kg/cm ma 4-20mA. (CAL) -. 3 ~ (+) (-). 3 ~ 10. ODV. Hi -.,

18 Lo -., ZPC = ZPC = : ZPC = A ma 4-20mA % DVC / > > /(2-2-3) /

19 -/ -. - /. Hi / - Hi / Hi 123%. Hi / Hi. Hi / -. Hi 99.5%. 125% Hi /. Hi -.. 0%/,. Lo / - Lo / Lo 23%. Hi / Lo. Lo / -. Lo 0.5%. 25% Lo /. Lo -.. 0%/,. -. closed 100%, open 0%. Lo. Lo -. closed 0%, open 100%. Hi. 19

20 AD, PD, ODV ( ). -. (). -. Point to Point 4 20mA. Multidrop 24VDC ( : ).,. 20

21 .. 0% 0%. 0% 100% ( %) ( %) %~106.25%... (1~21). Enter. 0.., (). (, ). 21

22 3 2. ( = ) , %, % , % , % = = , % 0 A , % = 22

23 SP - ( %). 0. SP - ( %). 0. () - (). 0.2~ () HC, AD PD. / - ODV -. /(Lead/Lag). /(Lead/Lag). /(lead and lag) ODV. () /(Lead/Lag) (Set Point).... /(Lead/Lag). /(Lead/Lag).. (). /(Lead/Lag). /(Lead/Lag) 1.0 /(Lead/Lag) ODV / /. 2.0 /

24 > > (2-2-4) /., C M. 3 3, C D E F G H I J K L M X( ) Proportional Gain, Velocity Gain, and Minor Loop Feedback Gain. / X( ).. ValveLink /. 3 4 Fisher Baumann... 24

25 3 4. Fisher 585C & 585CR & SR C , , , 30i 34, 34i, 40, 40i 45, 45i, 50, 50i 46, 46i, 60, 60i, 70, 70i, & , 30i 34, 34i, 40, 40i 45, 45i, 50, 50i 46, 46i, 60, 60i, 70, 70i, 76, 76i & , , , 80, 100, , , 30E 34, 34E, 40, 40E 45, 45E ( ). ( ) ( ) ( ) ( ) E I J L M H K L 225 X (1) GX 750 K 1200 M. 16 C 32 E 54 H Baumann 10 E 25 H 54 J ( ) X =. = 4.2, = 3.0, = A C. B. M H K L M H I K M J K L M G L H J M E H K (2) A C (3). A B C D P o (): P s (): 25

26 MLFB / /,.. /... ( : F-E).. ( : F-G)

27 12.. C M. B. 3 5, (integrator) B C D E F G H I J K L M X( ),,. X( ).. ValveLink /. -.. MLFB -.. (integral) -. (integral). (integral). (integral) - (integral) ( ) (integral).. / (integral) - (integral) 1. (Integrator) 1 (Set Point). (Dead Zone) 0%~2%, 1 (Set Point) 0%~+/-2%. 0.25%. 27

28 (integrator) - (integrator) (integrator). I/P 0~100%. > > (2-2-5) -. -,,, %... (DVC6200 ) mm SStem # SStem # SStem # SStem # SStem # SStem # SStem # SStem #1 > 210 > RShaft # RShaft # RShaft :. A = - - B = -, C= -, : "" -. Lo : Low Bleed. 28

29 - ( ). (ZPC) A - ( A C) A - 0 B -( A) -( B) A - 0 B - B - YES.. Clockwise/Toward Bottom Counterclockwise/Toward Top..... A C : A CW/To Bottom Inst. CCW/To Top Inst. B : A CW/To Bottom Inst. CCW/To Top Inst.. 29

30 A, A...,. A /.. A. (PST) > > (2-2-7) ODV. (). PST. Not Configured. Hi Hi - (%),. Lo Lo - (%), PST. PST,

31 3 4. PST 30% , () %. PST,

32 3 5. PST PST PST PST %/ %/. - (%).., 0.5% 1% 1.5%. - PST. - ( 3 4 ). DVC6200 (). PST ( : = = ),. 32

33 . A C B B C A - B B - A B A ValveLink.. 1. ValveLink DVC PST / ( 3 6 ). (Pmin). (Pmax) PST A C B Pmin * ( - ) Pmax * ( - ) Pmax * ( - ) Pmin * ( - ) Pmax * ( - ) Pmin * ( - ) Pmin * ( - ) Pmax * ( - ) - A C B 0.5 * Pmin Pmax * (Psupply - Pmax) Pmax * (Psupply - Pmax) 0.5 * Pmin Pmax * (Psupply - Pmax) 0.5 * Pmin 0.5 * Pmin Pmax * (Psupply - Pmax) A Pmin * (Psupply + Pmin) Pmax * (Psupply - Pmax) Pmax * (Psupply - Pmax) Pmin * (Psupply + Pmin) 33

34 3 6., (Pmin) ( ) (%) ( ) - ( 3 4 ). DVC6200 (). PST. 1. ( ) ( ) 7. SOV PST 8. PST PST.. PST PST.. 1. ( ) ( ) 7. SOV PST 8. 34

35 PST NVM

36 > > (2-2-6) HC, AD, PD (2-2-7) ODV 4 20mA. / DVC6200 Series, D103556X012. -, ValveLink % 4 20mA % ( 1A). - ( 1A). -.. (< 3.6mA). (> 22.5mA) mA

37 -. / /. HART 4 HART (PV) 2 (SV) 3 (TV) 4 (QV),, A, B, A B,,,, A, B, A B,,,, A, B, A B,, 4 20mA.. 4mA = 4mA =.. (HART ) HART. Tri Loop, 3. HART 5 - ( 1) - / ( 2) - /PV/SV/TV/QV( 3) HART ( 1) - / ( 2) - /PV/SV/TV/QV( 3) - ( 9) - ( 33) - ( 48) 37

38 HART /...,.. HART 7. Tri-Loop,., Tri-Loop.. > (2-3). ( 5 )., HART HART 48 (HART, D103639X012 ). ( : )... ( ).,,.. 5. HART 5 / HART 7 > > HART 5 / HART 7 (3-5-3) HC (3-5-4) AD, PD (3-5-5) ODV. HART.. HART Universal 5 HART Universal 7( ). HART Universal

39 4 44 DVC > > >. > (2-4) PST (ODV ) - 47 Instrument Mode Out Of Service, Protection None

40 . Yes, No High and Low End Points MLFB( ) (Bias). (, 0 100% ). MLFB. 2. In Service mA. 4.0mA >> > / ( ). 2.. >> > / ( ). 0?. (I/P ) ( ) ( )

41 mA mA. LOOP + LOOP -. 4~20mA. (%). 0% = 100% = 1.. OK. 2 ~ % OK % OK. 4. 0% OK % OK. 6. 5% OK % OK. 8. In Service. LOOP + LOOP mA. (%). 1.. OK. 0% = 100% = 41

42 2. 0%.,, 10.0%, 1.0% 0.1% % % % % % In Service.. 3~ > >. ( ). I/P.. ValveLink. 42

43 ... A B.. 1. (Regulator). OK. 2. 0,. x. OK. 3.. OK. 4.., 3.0psi/0.207bar/20.7kPa, 0.30psi/0.0207bar/2.07kPa 0.03psi/ bar/0.207kPa. OK (4) x. OK. 6.. OK. 7.. OK (7)

44 HC. (Regulator) a) Zero Only b) Zero and Span( ). a. Zero Only (Regulator). OK. 5. b. Zero and Span (Regulator). OK. (Regulator). OK Increase Decrease , 3.0psi/0.207bar/20.7kPa, 0.30psi/0.0207bar/2.07kPa 0.03psi/ bar/0.207kPa In Service. LOOP+ LOOP-. 4~20mA Input Range Low. OK

45 . 3.. OK. 4.., 0.4mA, 0.04mA 0.004mA. OK (4) Input Range High. OK OK. 8.. OK (8) In Service... B C. - - " A" ~ 70% ( 30 ). Low Bleed 2. 45

46 4 1. A ( ) - : - : - : W A ODV : ISA " C". C. - - " B". B. 46

47 PST (ODV ).,,.,... 47

48 , 5, 55 (1) 1. ( / ) ( HC ) /. ( 5 1 ) ID( ), DD HART ( /) 5 1. HC AD PD ODV ValveLink., HC,, (,, ), ValveLink Solo, ;,,,,. ValveLink (,, ). / (, ). /. 48

49 , (3).. DVC , DVC6200 HART NE107 (1) (1) (1) (1) NVM (1) (1) (1) (1) NVM (1) (Accumulator) /

50 , 5 2. () NE107 (integrator) (integrator) - - / / A NVM - NVM I/P. I/P. I/P. I/P : < 10% > 3% > 90% < 97% : < 10% < 97% > 90% > 3% 50

51 , -. -,. - ROM( ) (integrator) -. (integrator) mA.. 24mA. -.. NVM - NVM()... / -. Enter. -. DIP OUT. DIP. A A A. DVC6200 A.. - I/P ~ 125.0%. O-.. 51

52 , ~ 100 C(-76 ~ 212 F).... (accumulator) - (accumulator) (accumulator). (accumulator). (accumulator) Hi - Hi. Hi Hi Hi Lo Lo. 99% 1%,. ValveLink. Hi-Hi - Hi Hi. Hi Hi Lo - Lo. Lo Lo-Lo - Lo. Lo / Hi - Hi /. / Lo - Lo / ~ 125.0% (,, ).. (%).. 52

53 , Hi, Lo, Hi Hi Lo Lo. 5 1 Hi., A6532 (accumulator) (accumulator)... ( ) (accumulator) (10%) (+/- 5%). E

54 , %/ %/ %/. -. ODV. ODV DVC ~30% 0.1%. ValveLink. (10%) ()., 30% mA(Point-to-Point mode). ( ), ValveLink.. () DVC /-. 3~5. 1. ValveLink. 54

55 , 1. LOOP > >. 4. Standard (10%) Custom., 30%. 5. Stroke, Stroking Speed Pause Time. Yes. No. Stroke Speed 0.25%/ (Set Point).. ValveLink.. - DVC6200 DVC6200, " " "".,. 1. ( 100~200 ).,. 2. DVC ValveLink

56 , > (3-4).. ( /) ( / ) () ( HC ) / () () ( ) 56

57 6 66 DVC6200 Type 4X IP66. DVC6200 ( 52).. / DVC6200.,,..,

58 DVC6200 ValveLink.. ValveLink ValveLink DVC6200 DVC (D103556X012).. I/P, printed wiring board(pwb), DVC Phillips 5 mm 1.5 mm 2.5 mm 6 mm, printed wiring board(pwb) I/P 58

59 DVC ( 43) 4 ( 2). 2. 6mm 3 ( 38). ( 154) ( 1).. 4. / 6 1, 2. printed wiring board(pwb) printed wiring board(pwb) W9924-1_ 59

60 Guide Surface. PWB. Guide Surface. Guide Surface.,, ( 237) ( 1). O- ( 12). 2. PWB ( 50).. 3. ( 2) ( 1). ( 64) 3 ( 38). 4. ( 38) 3. 3 ( 154). 16N m(138lbf in). /. 5 / / 5. ( 43). 60

61 DVC6200 I/P, PWB.... I/P. I/P. I/P I/P ( 41). I/P. I/P I/P.. 1. I/P I/P ( 41) ( 169). 2. ( 231) I/P I/P O- I/P () W

62 4. I/P O- ( 39). 5. I/P I/P ( 41) ( 169). I/P 1. ( 43) mm ( 169) I/P ( 41) ( 2) 4 ( 23). 3. ( 169) I/P ( 41) ( 2). I/P. 4. O- ( 39) ( 231) I/P ( 41). I/P ( 2) O- ( 39) ( 231). O-. O ( 210) I/P ( 169) I/P ( 41) (4 ) ( 23) W9328 ( 210) 3. I/P ( 41) ( 2).. printed wiring board(pwb). 4. I/P ( 41) ( 169) ( 23) 1.6N m(14lbf ). 6. I/P. 62

63 (PWB) PWB ( 50) ( 2). PWB ( 33). 3. ( 2) PWB ( 50). 4. PWB ( 50) O- ( 40) ( 2). Printed wiring board(pwb) DIP 1. O- ( 40). 2. PWB ( 50). I/P ( 41) PWB PWB. 3. PWB ( 50). 4. 3( 33) 1N m(10.1lbf ) PWB DIP DIP (1) DIP PT-PT 4 20 ma Point - Point 24VDC Multi Drop

64 6 4. (PWB) X0463 / X ~ 20mA DIP point-to-point

65 ( 24).. 1. ( 24) W N m(20.7lbf ) Relay Type. 5.., DVC6200 DVC6205 ( 47), ( 66) ( 67). - ( 236, 7 3).. 65

66 , ( 43). 2.,. ( 47)... ( 66) ( 67). 3., ( 64). 4., (Terminal Strip). DVC6205 ( 6 6 ) X0338 DVC6200 X0379 DVC ( 4) ( 58). 2. ( 4). 66

67 PWB ( 50). 5. ( 72).. O-. 1. O- ( 34), O ( 72). ( 72). 3. PWB ( 50) O- ( 36), 25/8 O-. O-. 7. ( 63) 25/8. 8. ( 4). 9. ( 4) ( 58). (1 ). ( 58) DVC FIELDVUE kilohm Potentiometer

68 kilohm Potentiometer (± 0.08mA). 8.. > > (3-5-2) a.. 1a.. (Set Point)... 1b.. 1b. ( ). 1c.. 1c. ( ). 1d.. 1d. ( ). 1e.. 1e a.. 2a. ( ). 10VDC. 2b. (impedance). 2b. HART ( ). 2c.. 2c. ( ). 2d. HART. 2d. ( HART ). 2e.. 2e... 2f. 4mA. 2f.. 3.8mA. 2g. PWB. 2g.. 2h. PWB DIP. 2h. PWB DIP. PWB

69 j. PWB. 2j. 4-20mA. LOOP+ LOOP- 8.0 ~ 9.5VDC. 8.0 ~ 9.5VDC PWB. 3.,,. 4. ValveLink k.. 2k. ( ). Utility Configure Communicator>Polling >Always Poll. 0. 2l.. 2l. PWB.. 2m. ValveLink. 2m.. 2n. ValveLink PC. 2n. ValveLink. 2p. ValveLink. 2p.. 3a.. 3a. :.. : ( ) ( ) 3b. I/P. 3b. I/P.. I/P I/P. 3c. I/P O- O-. 3d. I/P /. 3c. O-. 3d., ( ),, ohm. I/P / I/P. 3e. h I/P. 3e. I/P. ( 55 ~ 80%, 60 ~ 85%). I/P. 3f.. 3f... 3g.. 3g... I/P.. 3h. 67CFR (Regulator). 3h. 67CFR (Regulator). 4a.. 4a. PWB. 4b. O-. 4b. O-. 5a.. 5a.. :... 69

70 DVC ? mA 20.0mA ma 20.0 ma. ( 4.0mA 8.6V, 20mA 8.8V ). 4. HART? 5.? AC HC AD PD ODV 6.? 7.? 8. ""? 9. "Analog"? 10.? 11.? % A B % % 12.? 13. ValveLink (Status Monitor, Detailed Setup ). 1.? DVC6200 DVC6205/DVC DVC6200,,,? 3.? 4.? 5. LBP/Customer. 6.? 7.? 70

71 7 77. Fisher. Emerson Automation Solutions Fisher.... 1* Elastomer Spare Parts Kit (kit contains parts to service one digital valve controller) Standard 19B5402X012 Extreme Temperature 19B5402X022 2* Small Hardware Spare Parts Kit (kit contains parts to service one digital valve controller) 19B5403X012 3* Seal Screen Kit [kit contains 25 seal screens (key 231) and 25 O rings (key 39)] 14B5072X182 4* Integral Mount Seal Kit (for 667 size 30i - 76i and GX actuators) [kit contains 5 seals (key 288)] 19B5402X032 Aluminum, with I/O Package Standard Standard, M20 Extreme Temperature Extreme Temperature, M20 19B5401X182 19B5401X392 19B5401X192 19B5401X402 Stainless Steel, without I/O Package Extreme Temperature, Natural Gas Certified 19B5401X312 Extreme Temperature, Natural Gas Certified, M20 19B5401X382 Stainless Steel, with I/O Package Extreme Temperature Extreme Temperature, M20 19B5401X202 19B5401X PWB Assembly (HW2) (see figure 7 2 and 7 4) for DVC6200 and DVC6205 PWB 7 1. Emerson. 5* Terminal Box Kit (see figure 7 1). PWB 2(HW2). Aluminum, without I/O Package Standard 19B5401X142 Standard, M20 19B5401X342 Standard, Natural Gas Certified 19B5401X162 Standard, Natural Gas Certified, M20 19B5401X362 Extreme Temperature 19B5401X152 Extreme Temperature, M20 19B5401X352 Extreme Temperature, Natural Gas Certified 19B5401X172 Extreme Temperature, Natural Gas Certified, M20 19B5401X372 Hardware Revision 2 (HW2), without I/O Package For instrument level HC For instrument level AD For instrument level PD For instrument level ODV Hardware Revision 2 (HW2), with I/O Package For instrument level HC For instrument level AD For instrument level PD For instrument level ODV * 71

72 7 1. I/O I/O 6* I/P Converter Kit Standard Extreme Temperature 38B6041X152 38B6041X132 7* Spare Module Base Assembly Kit, [kit contains module base (key 2); drive screws, qty. 2, (key 11); shield/label (key 19); hex socket cap screw, qty. 3, (key 38); self tapping screw, qty. 2 (key 49); pipe plug, qty. 3 (key 61); retaining ring, qty. 3 (key 154); screen (key 236); and flame arrestors, qty. 3 (key 243)] Aluminum GE18654X012 Stainless Steel GE18654X022 8* Spare Housing Assembly Kit [kit contains housing (key 1); vent assembly (key 52); seal (only included in Housing A kits) (key 288); seal (key 237); O ring (key 34); O ring (only used with integrally mounted regulator) (key 5)] 10 Remote Mount Feedback Unit Kit (see figure 7 5) [remote housing assembly (key25); hex socket set screw (key 58); 1/2 NPT pipe plug (key 62); wire retainer, qty 2 (key 131); terminal cover (key 255); o-ring (key 256); gasket (Housing A only, used for GX actuator) (key 287); seal (Housing A only, used for GX actuator) (key 288) 11 Feedback Array Kit Sliding Stem (Linear) [kit contains feedback array and hex socket cap screws, qty. 2, washer, plain, qty. 2, external tooth lock washer, qty. 2 (only with aluminum feedback array kit) and alignment template. 210 mm (8-1/4 inch) kit contains feedback array and hex socket cap screws, qty. 4, washer, plain, qty. 4, external tooth lock washer, qty. 4 (only with aluminum feedback array kit), alignment template and insert]. Stainless steel kits only for use with stainless steel mounting kits. 7 mm (1/4-inch) Aluminum GG20240X mm (3/4-inch) Aluminum GG20240X022 Stainless steel GE65853X mm (1-inch) Aluminum GG20240X032 Stainless steel GE65853X mm (1-1/2 inch) Aluminum GG20240X042 Stainless steel GE65853X mm (2-inch) Aluminum GG20240X052 Stainless steel GE65853X mm (4-1/8 inch) Aluminum GG20240X082 Stainless steel GE65853X mm (8-1/4 inch) Aluminum GG20243X012 Stainless steel GE65853X072 Aluminum Housing A (used for GX actuator) Standard Extreme Temperature Housing B (used for all actuators except GX) Standard Extreme Temperature Stainless Steel Housing B (used for all actuators except GX) Extreme Temperature 9* Spare I/P Shroud Kit [kit contains shroud (key 169) and hex socket cap screw, qty. 4 (key 23)] GE48798X032 GE48798X042 GE48798X072 GE48798X082 GE48798X102 GE29183X012 Rotary [Kit contains feedback assembly, pointer assembly, travel indicator scale and M3 machine pan head screws qty. 2]. Stainless steel kits only for use with stainless steel mounting kits. Aluminum GG10562X012 Stainless steel GG10562X022 Rotary array kit with coupler [Kit contains feedback assembly and NAMUR coupler] Aluminum GE71982X012 Stainless steel GE71982X Mounting Shield Kit [kit contains shield, qty. 3 and machine screws, qty. 6] GG05242X022 ( 10) /.. 13* Gasket/Seal Kit, for use with GX actuator [kit contains insulating gasket (key 287) and seal (key 288)] GE45468X *

73 .. / Emerson... ( ) DVC6200 DVC Housing (8) 11 Drive Screw (2 req'd) (DVC6205 only) 20 Shield (DVC6205 only) 52 Vent (2) 74 Mounting Bracket (DVC6205 only) 248 Screw, hex head (4 req d) (DVC6205 only) 249 Screw, hex head (4 req d) (DVC6205 only) 250 Spacer (4 req d) (DVC6205 only) 267 Standoff (2 req d) (DVC6205 only) 271 Screen (8) 287 Gasket, Housing A only (used for GX actuator) (DVC6200 only) 288 Seal (used for 667 size 30i - 76i and GX actuators) (DVC6200 only) ( 7 2, ) DVC6200 DVC * O ring (1) (3 req'd) 29 Warning label, for use only with LCIE hazardous area classifications 33 Mach Screw, pan head (2) (3 req'd) 38 Cap Screw, hex socket (2)(7) (3 req'd) 43* Cover Assembly (includes cover screws) Standard GG53748X012 Extreme temperature GG53748X Nameplate 49 Screw, self tapping (2 req'd) (7) 61 Pipe Plug, hex socket (7) Housing A with relay C (2 req'd ) (used for GX actuator) Housing A with relay B (1 req'd) (used for GX actuator) Housing B with relay B and C (1 req'd) (used for all actuators except GX) Not required for relay A * I/P Lithium grease (not furnished with the instrument) 64 Pipe thread sealant, anaerobic (not furnished with the instrument) 65 Lubricant, silicone sealant (not furnished with the instrument) 154 Retaining Ring (2) (3 req'd) 236 Screen (required for relay B and C only) (8) 237 Module Base Seal (1) ( ) DVC6200 DVC Module Base (7) 11 Drive Screw (7) (2 req'd) 12 O ring (1) 19 Shield (7) 61 Pipe Plug, hex socket (7) (3 req'd) 243 Slotted Pin (flame arrestor) (7) (3 req'd) I/P ( ) DVC6200 DVC Cap Screw, hex socket (2)(9) (4 req'd) 39* O ring (1)(3)(6) 41 I/P Converter (6) 169 Shroud (6)(9) (see figure 6 3) 210* Boot (1)(6) (2 req'd) (see figure 6 3) 231* Seal Screen (1)(3)(6) ( ) DVC6200 DVC * Relay Assembly, (includes shroud, relay seal, mounting screws) Standard Standard Bleed Housing A (used for GX actuator) Single acting direct (relay C) Single acting reverse (relay B) Housing B (used for all actuators except GX) Single acting direct (relay C) Double acting (relay A) Single acting reverse (relay B) Low Bleed Housing A (used for GX actuator) Single acting direct (relay C) Single acting reverse (relay B) Housing B (used for all actuators except G) Single acting direct (relay C) Double acting (relay A) Single acting reverse (relay B) 38B5786X182 38B5786X172 38B5786X132 38B5786X052 38B5786X092 38B5786X202 38B5786X192 38B5786X152 38B5786X072 38B5786X112 73

74 24* Relay Assembly, (includes shroud, relay seal, mounting screws) (continued) Extreme Temperature Standard Bleed Single acting direct (relay C) Double acting (relay A) Single acting reverse (relay B) 38B5786X142 38B5786X032 38B5786X102, ( 7 3 ) DVC6200 DVC6205 Low Bleed Single acting direct (relay C) Double acting (relay A) Single acting reverse (relay B) ( ) DVC6200 DVC Terminal Box Cap 34* O ring (1)(5) 36* O ring (1)(5) 58 Set Screw, hex socket (2) 72 Cap Screw, hex socket (2) 164 Terminal Box Assembly 38B5786X162 38B5786X082 38B5786X122 ( 7 4 ) DVC Terminal Box Cap 34* O ring (1)(5) 36* O ring (1)(5) 58 Set Screw, hex socket (2) 62 Pipe Plug, hex hd 262 Adapter 263* O-ring 47* Pressure Gauge Double acting (3 req'd); Single acting (2 req'd) PSI/MPA Gauge Scale To 60 PSI, 0.4 MPa To 160 PSI, 1.1 MPa PSI/bar Gauge Scale To 60 PSI, 4 bar To 160 PSI, 11 bar PSI/KG/CM 2 Gauge Scale To 60 PSI, 4 KG/CM 2 To 160 PSI, 11 KG/CM 2 66 Pipe Plug, hex head For units w/o gauges 67 Tire Valve, used with Tire Valve Option only Double acting (3 req'd); Single acting (2 req'd) DVC6215 ( 7 5 ) 65 Lubricant, silicone sealant (not furnished with the instrument) 256* O-Ring HART HF340, DIN rail mount HF341, DIN rail Mount, pass through (no filter) 74 *Recommended spare parts 1. Available in the Elastomer Spare Parts Kit 2. Available in the Small Hardware Spare Parts Kit 5. Available in the Terminal Box Kit

75 7 2. FIELDVUE DVC6200 A - (GX ) B - (GX ) - -- GE /3, O- 75

76 7 2. FIELDVUE DVC6200 () C-C 2 : 1 A-A E-E 2 : 1 SST, O- F-F 2 : 1 GE / , O- GE /3 76

77 7 4. FIELDVUE DVC6205 B-B A-A, O- H-H GE

78 7 4. FIELDVUE DVC6205 () C-C 2 : 1 SST E-E 2 : GE40181, O- 78

79 7 4. FIELDVUE DVC6205 () WALL GE40181, O- 79

80 7 5. FIELDVUE DVC6215 : 158 A-A / GE46670-B A (GX ) : 158 A-A GE40178-B / B (GX ) 80

81 A AA A HART HART(Highway Addressable Remote Transducer). 4-20mA 2.. HART,.. HART FSK( ). 1200Hz 2200Hz 4-20mA. 1 0 ( A 1 ). 4-20mA. HART 0 DC 4-20mA.. A 1. HART +0.5V 0-0.5V 1200Hz Hz 0 0 = 0 A6174 HART,. Pipelines, Custody Transfer Sites, Tank Farms. DIP 6 2. DVC6200 DVC6200,,. I/P, (pwb).. MLFB( ).. A 3, A 4, A 5, A 6. 81

82 A 2. ValveLink FIELDVUE -PC HART E1362 DVC I/P. I/P I/P. I/P., I/P.. (4-20mA ) A B. A. B. A 3, A 4, A 5, A... I/P.. I/P I/P. A B.. I/P.. 82

83 A 3. FIELDVUE DVC mA + HART A I/P B E1361 A 4. FIELDVUE DVC6200 AO 4-20mA A AI 8-30 VDC + - I/P B 83

84 A 5. FIELDVUE DVC6200 AO 4-20mA A I/P DI 30V + - B A 6. FIELDVUE DVC6200 I/P W

85 B HC, AD, PD ODV. //. ( B- 2 ). HC, AD, PD ODV / Actual Travel B- 5 Actuator Manufacturer B- 5 Actuator Model B- 5 Actuator Selection B- 5 Actuator Size B- 5 Actuator Style B- 7 Air B- 5 Alert Record Full (Alert Record/Status Alerts Enable) B- 9 Alert Record Full (Alert Record/Status Alerts NE107) B- 9 Alert Record Not Empty (Alert Record/Status Alerts Enable) B- 9 Alert Record Not Empty (Alert Record/Status Alerts NE107) B- 9 Alert Switch Source B- 7 Analog Input B- 3, B- 11 Analog Input (Calibration) B- 10 Analog Input Units B- 5 Area Units B- 5 Auto Calibration B- 4, B- 10 Autocal in Progress (Alert Record/Status Alerts Enable) B- 9 Autocal in Progress (Alert Record/Status Alerts NE107) B- 9 Auxiliary Terminal Action B- 5 Auxiliary Terminal Action, Edit B- 5 Breakout Timeout B- 7 Breakout Torque B- 5 Burst Command B- 7 Burst Enable B- 7 Calibration Button B- 5 Calibration in Progress (Alert Record/Status Alerts Enable) B- 9 Calibration in Progress (Alert Record/Status Alerts NE107) B- 9 Calibration Record B- 10 Calibration Time B- 10 Calibration Type B- 10 Calibrator B- 10 Change Control Mode B- 6, B- 11 Change Instrument Mode B- 1, B- 5 Change to HART 5 / Change to HART 7 B- 11 Change Travel/Pressure Select B- 6, B- 11 Change Write Protection B- 1, B- 3, B- 5 Clear Records B- 9, B- 11 Control Mode B- 6, B- 11 Critical NVM Failure (PST Prohibited Electronics Alerts) B- 9 / Critical NVM Failure (Electronics Alerts NE107) B- 8 Critical NVM Failure Shutdown B- 8 Custom Characterization B- 6, B- 11 Cycle Count B- 8, B- 11 Cycle Count Hi (Travel History Alerts Enable) B- 8 Cycle Count High (Travel History Alerts NE107) B- 8 Cycle Count High Alert Point B- 8 Cycle Count/Travel Accum Deadband B- 8 Days Powered Up B- 11 DD Information B- 3 Description B- 3, B- 5 Device ID B- 3 Device Revision B- 3 Device Setup B- 4 Device Status B- 3, B- 11 Diagnostic Data Available (Alert Record/Status Alerts Enable) B- 9 Diagnostic Data Available (Alert Record/Status Alerts NE107) B- 9 Diagnostic in Progress (Alert Record/Status Alerts Enable) B- 9 Diagnostic in Progress (Alert Record/Status Alerts NE107) B- 9 Drive Current Failure (Electronics Alerts NE107) B- 8 Drive Current Failure (PST Prohibited Electronics Alerts) B- 9 Drive Current Failure Shutdown B- 8 Drive Signal B- 3, B- 11 Drive Signal (Electronics Alerts Enable) B- 8 Drive Signal (Electronics Alerts NE107) B- 8 Dynamic Torque B- 5 Edit Cycle Counts B- 8 Edit Instrument Time B- 5, B- 9 Edit Travel Accumulator B- 8 Effective Area B- 5 Fail Signal B- 7 Fallback Recovery B- 6, B- 9, B- 11 Fallback-Sensor Failure B- 9 Fallback-Sensor/Travel Deviation B- 9 Feedback Connection B- 5, B- 7 Firmware Revision B- 3 Flash Integrity Failure (Electronics Alerts NE107) B- 8 Flash Integrity Failure (PST Prohibited Electronics Alerts) B- 9 Flash Integrity Failure Shutdown B- 8 Flow Direction B- 5 Flow Tends to B- 5 85

86 / Function B- 7 Hardware Revision (Device) B- 3 HART Long Tag B- 3, B- 5 HART Tag B- 3, B- 5 HART Universal Revision B- 3 HART Variable Assignments B- 7 High Friction Breakout Pressure B- 7 Hi Limit/Cutoff Point B- 6, B- 8 Hi Limit/Cutoff Select B- 6 Hi Soft Cutoff Rate B- 6 Incoming Pressure Threshold B- 7 Inlet Pressure B- 5 Input Characterization B- 6, B- 11 Input Range Hi B- 5 Input Range Lo B- 5 Instrument Alert Record B- 9 Instrument Level B- 3 Instrument Mode B- 1, B- 5 Instrument Serial Number B- 3, B- 5 Instrument Time is Approximate (Alert Record/Status Alerts Enable) B- 9 Instrument Time is Approximate (Alert Record/Status Alerts NE107) B- 9 Integral Enable (Travel & Pressure Tuning) B- 7 Integral Gain (Travel & Pressure Tuning) B- 7 Integrator Limit B- 7 Integrator Saturated Hi (Alert Record/Status Alerts Enable) B- 9 Integrator Saturated Hi (Alert Record/Status Alerts NE107) B- 9 Integrator Saturated Lo (Alert Record/Status Alerts Enable) B- 9 Integrator Saturated Lo (Alert Record/Status Alerts NE107) B- 9 Integral Dead Zone B- 7 Last AutoCal Status B- 10 Last PST Results B- 7 Leak Class B- 5 Length Units B- 5 Lever Arm Length B- 5 Lever Style B- 5 Limit Switch Trip Point B- 7 Limit Switch Valve Close B- 5 Limit Switch Valve Open B- 5 Lo Limit/Cutoff Point B- 6, B- 8 Lo Limit/Cutoff Select B- 6 Lo Soft Cutoff Range B- 6 Low Friction Breakout Pressure B- 7 Lower Bench Set B- 5 Manual Calibration B- 10 Manufacturer (Device) B- 3 Maximum Allowable Travel Movement B- 7 Maximum Recorded Temperature B- 11 Maximum Supply Pressure B- 7 Message B- 3, B- 5 Minimum Recorded Temperature B- 11 / Minimum Required Travel Movement B- 7 Minor Loop Sensor Failure (PST Prohibited Electronics Alerts) B- 9 Minor Loop Sensor Failure (PST Prohibited Electronic Alerts) B- 9 Minor Loop Sensor Failure (Sensor Alert NE107) B- 9 Minor Loop Sensor Failure Shutdown B- 9 MLFB Gain (Travel & Pressure Tuning) B- 7 Model (Device) B- 3 Nominal Supply B- 5 Non-Critical NVM Failure (Electronics Alerts NE107) B- 8 Non-Critical NVM Failure Shutdown B- 8 Number of Power Ups B- 11 Outgoing Pressure Threshold B- 7 Output Circuit Error (Electronics Alerts Enable) B- 8 Output Circuit Error (Electronics Alerts NE107) B- 8 Outlet Pressure B- 5 Output Pressure Limit Enable B- 8 Output Terminal Enable B- 7 Packing Type B- 5 Partial Stroke Test B- 11 Polling Address B- 5 Port A Overpressurized (Pressure Alerts Enable) B- 8 Port A Overpressurized (Pressure Alerts NE107) B- 8 Port A Pressure Limit B- 8 Port Diameter B- 5 Port Type B- 5 Position Transmitter B- 5 Pressure A B- 3, B- 11 Pressure A-B B- 3, B- 11 Pressure B B- 3, B- 11 Pressure Control B- 9 Pressure Deviation Alert Point B- 8 Pressure Deviation (Pressure Alerts Enable) B- 8 Pressure Deviation (Pressure Alerts NE107) B- 8 Pressure Deviation Time B- 8 Pressure Fallback Active (PST Prohibited Alerts Enable) B- 9 Pressure Fallback Active (Sensor Alerts Enable) B- 9 Pressure Fallback Active (Sensor Alerts NE107) B- 9 Pressure Range High B- 6 Pressure Range Low B- 6 Pressure Sensor Failure (PST Prohibited Alerts Enable) B- 9 Pressure Sensor Failure (Sensor Alerts NE107) B- 9 Pressure Sensor Failure Shutdown B- 9 Pressure Sensors (Calibration) B- 10 Pressure Tuning Set B- 7 Pressure Units B- 5 Program Flow Failure (Partial Stroke Alerts NE107) B- 9 Program Flow Failure Shutdown B- 9 Proportional Gain (Travel & Pressure Tuning) B- 7 PST Abnormal (Partial Stroke Alerts Enable) B- 9 PST Abnormal (Partial Stroke Alerts NE107) B- 9 PST Abnormal Criteria B- 7 86

87 / PST Abort Criteria B- 7 PST Enable B- 7 PST Calibration B- 10 PST Deferral Reason B- 7 PST Pass (Partial Stroke Alerts Enable) B- 9 PST Pass (Partial Stroke Alerts NE107) B- 9 PST Prohibited (Partial Stroke Alerts Enable) B- 9 PST Prohibited (Partial Stroke Alerts NE107) B- 9 PST Result Criticality B- 7 PST Start Point B- 7 PST Variables B- 7 Push Down To B- 5 PWB Serial Number B- 3 Quick Release B- 5 Rated Travel B- 5 Relay Adjust B- 10 Relay Type B- 7 Reference Voltage Failure (Electronics Alerts NE107) B- 8 Reference Voltage Failure (PST Prohibited Electronics Alerts) B- 9 Reference Voltage Failure Shutdown B- 8 Reset PST Abnormal Alert B- 11 Restart Control Mode B- 6, B- 11 Restart Processor B- 11 Return Lead B- 7 Seat Type (Trim) B- 5 Setpoint B- 3, B- 8, B- 11 Short Duration PST B- 7 Shutdown Activated (Electronics Alerts Enable) B- 8 Shutdown Activated (Electronics Alerts NE107) B- 8 Simulate B- 11 Solenoid Valve B- 5 SP Rate Close B- 6 SP Rate Open B- 6 Spring Rate B- 5 Spring Rate Units B- 5 Stabilize/Optimize B- 7, B- 11 Stem Diameter B- 5 Stroke Valve B- 11 Supply Pressure B- 3, B- 8, B- 11 Supply Pressure Hi (Pressure Alerts Enable) B- 8 Supply Pressure Hi (Pressure Alerts NE107) B- 8 Supply Pressure Hi Alert Point B- 8 Supply Pressure Lo (PST Prohibited Alerts Enable) B- 8 Supply Pressure Lo (Pressure Alerts Enable) B- 8 Supply Pressure Lo Alert Point B- 6, B- 8 Switch Closed B- 7 Temperature B- 11 Temperature Units B- 5 Temp Sensor Failure (PST Prohibited Alerts Enable) B- 9 Temp Sensor Failure (Sensor Alerts NE107) B- 9 Temp Sensor Failure Shutdown B- 9 Torque Units B- 5 Transmitter Output B- 7 Travel B- 3, B- 8, B- 11 Travel Accumulator (Alert Setup) B- 8 / Travel Accumulator (Travel History) B- 11 Travel Accumulator Alert Point B- 8 Travel Accumulator High (Travel History Alerts Enable) B- 8 Travel Accumulator High (Travel History Alerts NE107) B- 8 Travel Alert Deadband B- 8 Travel Control B- 9 Travel Counts B- 11 Travel Deviation B- 8 Travel Deviation (PST Prohibited Alerts Enable) B- 9 Travel Deviation (Travel Alerts Enable) B- 8 Travel Deviation (Travel Alerts NE107) B- 8 Travel Deviation Alert Point B- 8 Travel Deviation Time B- 8 Travel Deviation Pressure Fallback B- 6 Travel Deviation Pressure Fallback Time B- 6 Travel Hi (Travel Alerts Enable) B- 8 Travel Hi (Travel Alerts NE107) B- 8 Travel Hi Hi (Travel Alerts Enable) B- 8 Travel Hi Hi (Travel Alerts NE107) B- 8 Travel Hi Alert Point B- 8 Travel Hi Hi Alert Point B- 8 Travel Lo (Travel Alerts Enable) B- 8 Travel Lo (Travel Alerts NE107) B- 8 Travel Lo Lo (Travel Alerts Enable) B- 8 Travel Lo Lo (Travel Alerts NE107) B- 8 Travel Lo Alert Point B- 8 Travel Lo Lo Alert Point B- 8 Travel Limit/Cutoff Hi (Travel Alerts Enable) B- 8 Travel Limit/Cutoff Hi (Travel Alerts NE107) B- 8 Travel Limit/Cutoff Lo (Travel Alerts Enable) B- 8 Travel Limit/Cutoff Lo (Travel Alerts NE107) B- 8 Travel/Pressure Select B- 6, B- 9, B- 11 Travel Sensor Failure (Sensor Alerts NE107) B- 9 Travel Sensor Failure (PST Prohibited Alerts Enable) B- 9 Travel Sensor Failure Shutdown B- 9 Travel Sensor Motion B- 5, B- 7 Travel Tuning Set B- 7 Travel Units B- 5 Unbalanced Area B- 5 Upper Bench Set B- 5 Valve Class B- 5 Valve Manufacturer B- 5 Valve Model B- 5 Valve Serial Number B- 3, B- 5 Valve Size B- 5 Valve Style B- 5, B- 7 Velocity Gain B- 7 View Alert Records B- 9, B- 11 View/Edit Burst Messages B- 7 View/Edit Lag Time B- 6 Volume Booster B- 5 Write Protection B- 1, B- 3, B- 5 Zero Power Condition B- 7 87

88 B- 1. B- 2. Hot Key 1 Instrument Mode 2 Change Instrument Mode 3 Write Protection 4 Change Write Protection HART Application 1 Offline 2 Online 3 Utility 4 HART Diagnostics Online 1 Overview 2 Configure 3 Service Tools B- 3. (1) Overview 1 Device Status 2 Analog Input 3 Setpoint 4 Travel 5 Drive Signal 6 Pressure Variables 7 Device Information 1-6 Pressure Variables 1 Supply Pressure 2 Pressure A 3 Pressure B 4 Pressure A-B 1-7 Device Information 1 Identification 2 Revisions 3 Security Security 1 Write Protection 2 Change Write Protection Identification 1 HART Tag 2 HART Long Tag 2 3 Manufacturer 4 Model 5 Instrument Level 6 Device ID and Serial Numbers 7 Message 8 Description Revisions 1 HART Universal Revision 2 Device Revision 3 Hardware Revision 4 Firmware Revision 5 DD Information Device ID and Serial Numbers 1 Device ID 2 Valve Serial Number 3 Instrument Serial Number 4 PWB Serial Number : 1 AD, PD ODV. 2 HART HART 7. B- 4. (2-1) Guided Setup 1 Device Setup 2 Auto Calibration 88

89 B- 5. > (2-2-1) > (2-2-2) Manual Setup 1 Mode and Protection 2 Instrument 3 Travel/Pressure Control 4 Tuning 5 Valve and Actuator 6 Partial Stroke Test (PST) 7 Outputs Accessories 1 Volume Booster 2 Quick Release 3 Solenoid Valve 4 Position Transmitter 5 Limit Switch Valve Open 6 Limit Switch Valve Close Lever Style 1 Lever Style 2 Lever Arm Length : 1 HART HART 7. 2 ODV Mode and Protection Identification 1 Instrument Mode 1 HART Tag 2 Change Instrument Mode 2 HART Long Tag 3 Write Protection 3 Description 4 Change Write Protection 4 Message 5 Polling Address Instrument Identification Serial Numbers 2 Serial Numbers 3 Units 4 Terminal Box 5 Analog Input Range 6 Spec Sheet Units 7 Edit Instrument Time Spec Sheet 1 Units 2 Valve 3 Trim 4 Actuator 5 Accessories Trim 1 Seat Type 2 Leak Class 3 Port Diameter 4 Port Type 5 Flow Direction 6 Push Down To 7 Flow Tends To 8 Unbalanced Area Actuator 1 Actuator Manufacturer 2 Actuator Model 3 Actuator Size 4 Actuator Selection 5 Travel 3 6 Lever Style 7 Effective Area 8 Spring Rate 9 Air Air 1 Air 2 Upper Bench Set 3 Lower Bench Set 4 Nominal Supply Valve 1 Valve Manufacturer 2 Valve Model 3 Valve Serial Number 4 Valve Style 5 Stem Diameter 6 Packing Type 7 Valve Travel 8 Inlet/Outlet Pressures 9 Torque Travel 1 Feedback Connection 2 Travel Sensor Motion 3 1 Instrument Serial Number 2 Valve Serial Number 1 Pressure Units 2 Temperature Units 3 Analog Input Units Terminal Box 1 Calibration Button 2 Auxiliary Terminal Action 2 3 Edit Auxiliary Terminal Action Analog Input Range 1 Input Range Hi 2 Input Range Lo Units 1 Travel Units 2 Length Units 3 Area Units 4 Spring Rate Units 5 Torque Units Valve Style 1 Valve Style 2 Valve Size 3 Valve Class Valve Travel 1 Rated Travel 2 Actual Travel Inlet/Outlet Pressures 1 Inlet Pressure 2 Outlet Pressure Torque 3 1 Dynamic Torque 2 Breakout Torque 2 89

90 B- 6. > /(2-2-3) Manual Setup 1 Mode and Protection 2 Instrument 3 Travel/Pressure Control 4 Tuning 5 Valve and Actuator 6 Partial Stroke Test (PST) 7 Outputs : 1 AD, PD ODV Travel/Pressure Control 1 Travel/Pressure Select 2 Change Travel/Pressure Select 3 Cutoffs/Limits 4 Pressure Control 5 Pressure Fallback 1 6 Control Mode 7 Characterization 8 Dynamic Response (HC) (AD, PD, ODV) Dynamic Response 1 SP Rate Open 2 SP Rate Close 3 View/Edit Lag Time (HC) (AD, PD, ODV) Characterization 1 Input Characterization 2 Custom Characterization Cutoffs and Limits 1 Hi Limit/Cutoff Select 2 Hi Limit/Cutoff Point 3 Hi Soft Cutoff Rate 4 Lo Limit/Cutoff Select 5 Lo Limit/Cutoff Point 6 Lo Soft Cutoff Rate Pressure Control 1 Pressure Range High 2 Pressure Range Low (AD, PD, ODV) Pressure Fallback 1 1 Tvl Dev Press Fallback 2 Tvl Dev Press Fallback Time 3 Fallback Recovery 4 Supply Pressure Lo Alert Point (HC) (AD, PD, ODV) Control Mode 1 Control Mode 2 Change Control Mode 3 Restart Control Mode 90

91 B- 7. > (2-2-4) > (2-2-7) Manual Setup 1 Mode and Protection 2 Instrument 3 Travel/Pressure Control 4 Tuning 5 Valve and Actuator 6 Partial Stroke 1 7 Outputs WITH I/O PACKAGE (HC, AD, PD) (ODV) Outputs 1 Output Terminal Config 2 Limit Switch Configuration 3 Alert Switch Configuration 4 HART Var Assignments 5 Transmitter Output 6 Burst Mode (HC, AD, PD) (ODV) Burst Mode 1 Burst Enable 2 View/Edit Burst Messages (HC, AD, PD) (ODV) HART Var Assignments 1 Primary Variable (PV) 2 Secondary Variable (SV) 3 Tertiary Variable (TV) 4 Quaternary Variable (QV) 2 WITH I/O PACKAGE WITHOUT I/O PACKAGE Tuning 1 Travel Tuning 2 Pressure Tuning 3 Travel/Pressure Integral Settings Travel/Pressure Integral Settings 1 Integral Dead Zone 2 Integrator Limit (HC, AD, PD) (ODV) Output Terminal Config 1 Output Terminal Enable 2 Function 3 Fail Signal (HC, AD, PD) (ODV) Limit Switch Configuration 1 Limit Switch Trip Point 2 Switch Closed Valve and Actuator 1 Valve Style 2 Actuator Style 3 Feedback Connection 4 Relay Type 5 Zero Power Condition 6 Travel Sensor Motion 7 Max Supply Pressure (HC, AD, PD) (ODV) Alert Switch Configuration 1 Alert Switch Source Partial Stroke 1 1 Test Configuration 2 Test Acceptance Criteria 3 PST Alert Behavior 4 PST Deferral Reason 5 Last PST results PST Alert Behavior 1 PST Abnormal Criteria 2 PST Abort Criteria 3 PST Result Criticality Travel Tuning 1 Travel Tuning Set 2 Proportional Gain 3 Velocity Gain 4 MLFB Gain 5 Integral Enable 6 Integral Gain 7 Stabilize/Optimize Pressure Tuning 1 Pressure Tuning Set 2 Proportional Gain 3 MLFB Gain 4 Integral Enable 5 Integral Gain Test Configuration 1 PST Enable 2 PST Start Point 3 PST Variables 4 Return Lead 5 Short Duration PST 6 Max Allowable Travel Movement 7 Min Required Travel Movement Test Acceptance Criteria 1 Outgoing Pressure Threshold 2 Incoming Pressure Threshold 3 High Friction Breakout Press 4 Low Friction Breakout Press 5 Breakout Timeout WITHOUT I/O PACKAGE (HC, AD, PD) (HC, AD, PD) (ODV) (ODV) Outputs HART Var Assignments 1 HART Var Assignments 1 Primary Variable (PV) 2 Burst Mode 2 Secondary Variable (SV) 3 Tertiary Variable (TV) 4 Quaternary Variable (QV) (HC, AD, PD) (ODV) Burst Mode 1 Burst Enable 2 View/Edit Burst Messages 2 : 1 ODV. 2 HART 5 ' '. 91

92 B- 8. > (2-3-4) (2-3-1) : Alert Setup 1 Electronics 2 Pressure 3 Travel 4 Travel History 5 Partial Stroke 1 6 Sensors 7 Alert Record/Status Travel History Alerts Enable 1 Cycle Count Hi 2 Tvl Accum Hi Travel History 1 Travel History Alerts Enable 2 Travel History Alerts NE Cycle Count/Travel Accum Deadband 4 Cycle Counter 5 Travel Accumulator Travel Accumulator 1 Travel Accumulator 2 Edit Travel Accumulator 3 Travel Accumulator Alert Point 1 ODV Cycle Counter 1 Cycle Count 2 Edit Cycle Counts 3 Cycle Count High Alert Point Electronics 1 Electronic Alerts Enable 2 Electronic Alerts NE107 3 Electronic Alerts Shutdown Electronic Alerts Shutdown 1 Drive Current Failure Shutdown 2 Critical NVM Failure Shutdown 3 Non-Critical NVM Failure Shutdown 4 Flash Integrity Failure Shutdown 5 Reference Voltage Failure Shutdown Pressure 1 Pressure Alerts Enable 2 Pressure Alert NE Supply Pressure 3 Supply Pressure Hi Alert Point 4 Supply Pressure Lo Alert Point 5 Pressure Deviation Alert Point 6 Pressure Deviation Time 7 Port A Pressure Limit 8 Output Pressure Limit Enable Travel History Alerts NE107 1 Cycle Count High 2 Travel Accumulator High Travel 1 Travel Alerts Enable 2 Travel Alerts NE Travel 4 Setpoint 5 Travel Alert DB 6 Travel Deviation 7 Travel Limit 8 Travel Limit/Cutoff Travel Limit/Cutoff 1 Hi Limit/Cutoff Point 2 Lo Limit/Cutoff Point Travel Limit 1 Travel Hi Hi Alert Point 2 Travel Lo Lo Alert Point 3 Travel Hi Alert Point 4 Travel Lo Alert Point 2 AD, PD ODV NE107 HART 7. HART 5 NE Electronic Alerts Enable 1 Drive Signal 2 Shutdown Activated 3 Output Circuit Error Electronic Alerts NE107 1 Drive Current Failure 2 Drive Signal 3 Critical NVM Failure 4 Non-Critical NVM Failure 5 Flash Integrity Failure 6 Reference Voltage Failure 7 Shutdown Activated 8 Output Circuit Error Pressure Alerts Enable 1 Supply Pressure Hi 2 Supply Pressure Lo 2 3 Pressure Deviation 4 Port A Overpressurized Pressure Alerts NE107 1 Supply Pressure Hi 2 Supply Pressure Lo 2 3 Pressure Deviation 4 Port A Overpressurized Travel Alerts Enable 1 Tvl Deviation 2 Tvl Hi Hi 3 Tvl Lo Lo 4 Tvl Hi 5 Tvl Lo 6 Tvl Limit/Cutoff Hi 7 Tvl Limit/Cutoff Lo Travel Alerts NE107 1 Travel Deviation 2 Travel Hi Hi 3 Travel Lo Lo 4 Travel Hi 5 Travel Lo 6 Travel Limit/Cutoff Hi 7 Travel Limit/Cutoff Lo Travel Deviation 1 Travel Deviation 2 Travel Deviation Alert Point 3 Travel Deviation Time 92

93 B- 9. > /(2-3-7) (2-3-5) Alert Setup 1 Electronics 2 Pressure 3 Travel 4 Travel History 5 Partial Stroke 1 6 Sensors 7 Alert Record/Status (HC, AD, PD) (ODV) Alert Record/Status 1 Alert Record/Status Alerts Enable 2 Alert Record/Status Alerts NE View Alert Records 4 Clear Records 5 Instrument Alert Record 6 Edit Instrument Time (ODV) Partial Stroke 1 Partial Stroke Alerts Enable 2 Partial Stroke Alerts NE Partial Stroke Alerts Shutdown 4 PST Prohibited Alerts Enable (ODV) PST Prohibited Alerts Enable 1 PST Prohibited Electronic Alerts 2 Travel Sensor Failure 3 Pressure Sensor Failure 4 Temp Sensor Failure 5 Pressure Fallback Active 6 Supply Pressure Lo 7 Travel Deviation (ODV) Partial Stroke Alerts Enable 1 PST Abnormal 2 PST Pass 3 PST Prohibited (ODV) Partial Stroke Alerts NE107 1 PST Abnormal 2 PST Pass 3 PST Prohibited 4 Program Flow Failure (ODV) Partial Stroke Alerts Shutdown 1 Program Flow Failure Shutdown (ODV) PST Prohibited Electronic Alerts 1 Critical NVM Failure 2 Drive Current Failure 3 Reference Voltage Failure 4 Minor Loop Sensor Failure 5 Flash Integrity Failure (HC, AD, PD) (ODV) Alert Record/Status Alerts NE107 1 Alert Record Not Empty 2 Alert Record Full 3 Instrument Time is Approximate 4 Calibration in Progress 5 Autocal in Progress 6 Diagnostic in Progress 7 Diagnostic Data Avail 8 Integrator Sat Hi 9 Integrator Sat Lo (HC, AD, PD) (ODV) Alert Record/Status Alerts Enable 1 Alert Record Not Empty 2 Alert Record Full 3 Instrument Time is Approximate 4 Calibration in Progress 5 Autocal in Progress 6 Diagnostic in Progress 7 Diagnostic Data Avail 8 Integrator Sat Hi 9 Integrator Sat Lo (HC, AD, PD) (ODV) Sensors 1 Sensor Alerts Enable 2 Sensor Alerts NE Sensor Alerts Shutdown 4 Change Travel/Pressure Select 2 5 Travel/Pressure Select 2 6 Fallback Recovery (HC, AD, PD) (ODV) Change Travel/Pressure Select 1 Travel Control 2 Pressure Control 3 Fallback-Sensor Failure 4 Fallback-Sensor/Tvl Deviation (HC, AD, PD) (ODV) Sensor Alerts Enable 1 Pressure Fallback Active (HC, AD, PD) (ODV) Sensor Alerts NE107 1 Travel Sensor Failure 2 Pressure Sensor Failure 3 Temp Sensor Failure 4 Minor Loop Sensor Failure 5 Pressure Fallback Active (HC, AD, PD) (ODV) Sensor Alerts Shutdown 1 Travel Sensor Failure Shutdown 2 Pressure Sensor Failure Shutdown 3 Temp Sensor Failure Shutdown 4 Minor Loop Sensor Failure Shutdown 2 : 1 ODV. 2 AD, PD ODV. 3 NE107 HART 7. HART 5 NE

D103605X0KR_Jun17

D103605X0KR_Jun17 DVC6200 Fisher FIELDVUE DVC6200 HC, AD, PD, ODV 09 1, 2 2 2, 3, 4, 5, 6 DD 1, 2, 3, 4, 5 1... 3,,... 3... 3... 3... 3... 5... 5... 8 2... 9... 9 HART... 9... 9... 11... 12... 12 Rosemount 333 HART Tri-Loop

More information

D103198X0KR_Jul18 Korean

D103198X0KR_Jul18 Korean Fisher i2p-100... 1... 1... 2... 2... 2... 5... 7... 7... 8... 9... 10... 10... 11... 12... 12... 12... 12... 14... 14... 16... 16... 17... 18 1. Fisher i2p-100 W8710... 19... 20 Fisher i2p 100,, ( 1 )..,,,,

More information

D101351X0KR_May17

D101351X0KR_May17 646 Fisher 646... 1... 1... 3... 4... 4... 4... 5... 5... 5... 6... 7... 7... 7... 9... 9... 9... 9... 10... 11... 12... 12... 13... 15... 15... 15 1. Fisher 646 Fisher 646,,..,,,, 646,.,,.. W6783 1 www.fisher.com

More information

D103203X0KR_Jul17

D103203X0KR_Jul17 DVC2000 2017 7 Fisher FIELDVUE DVC2000... 2... 4... 4... 15... 18... 29... 31 W8861-2,,., DVC2000 (D103176X012)., Fisher.com. www.fisher.com DVC2000 2017 7 1 2 3 4 5 6 7 TRAVEL = 66.8% 14.6MA 0.92BAR (position

More information

D102005X0KR_May18

D102005X0KR_May18 846 Fisher 846 -... 2... 2... 2... 5... 6... 7... 8... 8... 10... 14... 14... 15... 15... 16 :,... 18 :,... 18 :,... 19 4 ~ 12mA... 19 12 ~ 20mA... 19 :,... 20 :,... 20 :,... 21 4 ~ 12mA... 21 12 ~ 20mA...

More information

D200138X0KR_Jun19

D200138X0KR_Jun19 Fisher 358 358i 58i............ 5... 6... 6... 6 58i... 8... 9... 14... 14... 14... 16... 16... 16... 17 358i... 17 58i... 19... 0... 0 ( ) 1. Fisher 358 358i W5498 1 W844-1 358 358i www.fisher.com ()......

More information

D101728X0KR_Oct18

D101728X0KR_Oct18 3710 3720 Fisher 3710 3720 3722... 2... 2... 2... 5... 6... 6 3722... 6 3722... 7... 8... 8 25 50 585 585R 3710 3720... 13... 15... 16... 17... 17,,... 17... 19 3720... 19... 20... 22... 22... 23... 24...

More information

D200138X0KR_Aug17

D200138X0KR_Aug17 358, 58i, 3583 Fisher 358 358i, 58i, 3583............ 6... 7... 7... 7 58i... 8 CSA... 9 FM... 10 ATEX... 10 IECEx... 1... 13... 18... 18... 18... 0... 0... 0... 1 358i... 1 58i... 3... 4... 4... 6 ( )

More information

D103214X0KR_Jul17

D103214X0KR_Jul17 DLC3010 Fisher FIELDVUE DLC3010... 2... 8... 13... 18... 23... 28... 29 : DLC3010 1 1 8 DD 3 W7977-2 475 DLC3010.,, DLC3010 (D102748X012). Emerson www.fisher.com. Emerson Performance Technologies. www.fisher.com

More information

D103621X0KR_Jan18

D103621X0KR_Jan18 Fisher 1308(16) 4872(10) 4 5 DD 1 1. Fisher (/ )... 2... 2... 2... 4... 4 FCC... 4... 4... 9... 10... 10... 12... 12 AMS AMS.. 13... 14 /... 15 -() ( : Fisher 667)... 17 ( )... 18 /... 20... 22... 22...

More information

D101728X0KR_Sep15_AQ

D101728X0KR_Sep15_AQ 3710 3720 Fisher 3710 3720 3722... 2... 2... 2... 5... 6... 6 3722... 6 3722... 7 CSA... 7 FM... 8 ATEX... 8 IECEx... 10... 11... 11 25 50 585 585R 3710 3720... 16... 18... 19... 20... 20,,... 20... 22

More information

X-VA-MT3809G-MT3810G-kor

X-VA-MT3809G-MT3810G-kor www.brooksinstrument.com 기본적인 설명 진행전 반드시 읽어 주십시오. Brooks 는 많은 국내 및 국제 기준을 충족하기 위해 제품을 설계, 생산 및 테스트를 합니다. 이 제품이 제대로 설치, 운영되고 그 들이 정상 사양 내에서 작동하도록 지속적인 유지보수가 필요합니다. Brooks Instrument 제품을 설치, 사용 및 유지보수 시

More information

소개.PDF

소개.PDF (c) Process Pressure Measurement 1 Process Pressure Measurement Flow, Level, Temperature Flow, Level, Temperature, 2, 1) ( ),, A F F/A 2), 3 (a) (b) (a) (b) (c) 1 (a) (ABSOLUTE PRESSURE), 10 kg/cm 2 abs

More information

Microsoft Word - Installation and User Manual_CMD V2.2_.doc

Microsoft Word - Installation and User Manual_CMD V2.2_.doc CARDMATIC CMD INSTALLATION MANUAL 씨앤에이씨스템(C&A SYSTEM Co., Ltd.) 본사 : 서울특별시 용산구 신계동 24-1(금양빌딩 2층) TEL. (02)718-2386( 代 ) FAX. (02) 701-2966 공장/연구소 : 경기도 고양시 일산동구 백석동 1141-2 유니테크빌 324호 TEL. (031)907-1386

More information

나사식볼밸브.indd

나사식볼밸브.indd HWASUNG VALVES 19~1990 001~010 19. 03 19. 0 1991~000 199. 1 199. 1 199. 11 199. 09 1999. 03 1999. 09 1999. 09 1999. 10 1999. 11 000. 0 000. 03 001~010 001. 03 001. 10 001. 11 00. 0 003. 03 003. 0 00. 01

More information

Coriolis.hwp

Coriolis.hwp MCM Series 주요특징 MaxiFlo TM (맥시플로) 코리올리스 (Coriolis) 질량유량계 MCM 시리즈는 최고의 정밀도를 자랑하며 슬러리를 포함한 액체, 혼합 액체등의 질량 유량, 밀도, 온도, 보정된 부피 유량을 측정할 수 있는 질량 유량계 이다. 단일 액체 또는 2가지 혼합액체를 측정할 수 있으며, 강한 노이즈 에도 견디는 면역성, 높은 정밀도,

More information

歯메뉴얼v2.04.doc

歯메뉴얼v2.04.doc 1 SV - ih.. 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 - - - 23 24 R S T G U V W P1 P2 N R S T G U V W P1 P2 N R S T G U V W P1 P2 N 25 26 DC REACTOR(OPTION) DB UNIT(OPTION) 3 φ 220/440 V 50/60

More information

GD-SERISE / GS-SERISE DESCRIPTION GD / GS series pneumatic actuator are designed & developed with new concept for the next generation. GD / GS series

GD-SERISE / GS-SERISE DESCRIPTION GD / GS series pneumatic actuator are designed & developed with new concept for the next generation. GD / GS series High Class 공압식엑츄에이터 PNEUMATIC ACTUATORS Rack & Pinion Designed GD-SERISE Double Acting GD-SERISE Single Acting (Spring Return) GINICE Co., Ltd www.ginice.co.kr / www.ginice.com GD-SERISE / GS-SERISE DESCRIPTION

More information

untitled

untitled 1... 2 System... 3... 3.1... 3.2... 3.3... 4... 4.1... 5... 5.1... 5.2... 5.2.1... 5.3... 5.3.1 Modbus-TCP... 5.3.2 Modbus-RTU... 5.3.3 LS485... 5.4... 5.5... 5.5.1... 5.5.2... 5.6... 5.6.1... 5.6.2...

More information

(specifications) 3 ~ 10 (introduction) 11 (storage bin) 11 (legs) 11 (important operating requirements) 11 (location selection) 12 (storage bin) 12 (i

(specifications) 3 ~ 10 (introduction) 11 (storage bin) 11 (legs) 11 (important operating requirements) 11 (location selection) 12 (storage bin) 12 (i SERVICE MANUAL N200M / N300M / N500M ( : R22) e-mail : jhyun00@koreacom homepage : http://wwwicematiccokr (specifications) 3 ~ 10 (introduction) 11 (storage bin) 11 (legs) 11 (important operating requirements)

More information

Pilot Operated Regulator 1098-EGR 용도 도시가스지구정압기 (City Gate Station, Main Station) 도시가스지역정압기 (District Station) 상 공업용대유량전용정압기 ( 빌딩, 공장, 병원, 학교 ) 산업용대유량기

Pilot Operated Regulator 1098-EGR 용도 도시가스지구정압기 (City Gate Station, Main Station) 도시가스지역정압기 (District Station) 상 공업용대유량전용정압기 ( 빌딩, 공장, 병원, 학교 ) 산업용대유량기 용도 도시가스지구정압기 (City Gate Station, Main Station) 도시가스지역정압기 (District Station) 상 공업용대유량전용정압기 ( 빌딩, 공장, 병원, 학교 ) 산업용대유량기구 Governor (Mixer, Boiler, Furnace, Plant Air Service) 특징 고정밀도, 대유량 - Loading Type Pilot

More information

PowerChute Personal Edition v3.1.0 에이전트 사용 설명서

PowerChute Personal Edition v3.1.0 에이전트 사용 설명서 PowerChute Personal Edition v3.1.0 990-3772D-019 4/2019 Schneider Electric IT Corporation Schneider Electric IT Corporation.. Schneider Electric IT Corporation,,,.,. Schneider Electric IT Corporation..

More information

MAX+plus II Getting Started - 무작정따라하기

MAX+plus II Getting Started - 무작정따라하기 무작정 따라하기 2001 10 4 / Version 20-2 0 MAX+plus II Digital, Schematic Capture MAX+plus II, IC, CPLD FPGA (Logic) ALTERA PLD FLEX10K Series EPF10K10QC208-4 MAX+plus II Project, Schematic, Design Compilation,

More information

(Table of Contents) 2 (Specifications) 3 ~ 10 (Introduction) 11 (Storage Bins) 11 (Legs) 11 (Important Operating Requirements) 11 (Location Selection)

(Table of Contents) 2 (Specifications) 3 ~ 10 (Introduction) 11 (Storage Bins) 11 (Legs) 11 (Important Operating Requirements) 11 (Location Selection) SERVICE MANUAL (Table of Contents) 2 (Specifications) 3 ~ 10 (Introduction) 11 (Storage Bins) 11 (Legs) 11 (Important Operating Requirements) 11 (Location Selection) 12 (Storage Bins) 12 (Ice Machine)

More information

歯FDA6000COP.PDF

歯FDA6000COP.PDF OPERATION MANUAL AC Servo Drive FDA6000COP [OPERATION UNIT] Ver 1.0 (Soft. Ver. 8.00 ~) FDA6000C Series Servo Drive OTIS LG 1. 1.1 OPERATION UNIT FDA6000COP. UNIT, FDA6000COP,,,. 1.1.1 UP DOWN ENTER 1.1.2

More information

13장_

13장_ C H A P T E R 13 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 13.1 ( ) 12 000 psi [ 13 1] 6in 10 [ 13 2] (stamping) 500 501 (pressure regulator) (oil mist) (lubricator) (air dryer) (muffler) 13.2 21 % 78 % 1 % 4

More information

DC Link Application DC Link capacitor can be universally used for the assembly of low inductance DC buffer circuits and DC filtering, smoothing. They

DC Link Application DC Link capacitor can be universally used for the assembly of low inductance DC buffer circuits and DC filtering, smoothing. They DC Link Capacitor DC Link Application DC Link capacitor can be universally used for the assembly of low inductance DC buffer circuits and DC filtering, smoothing. They are Metallized polypropylene (SH-type)

More information

LCD Display

LCD Display LCD Display SyncMaster 460DRn, 460DR VCR DVD DTV HDMI DVI to HDMI LAN USB (MDC: Multiple Display Control) PC. PC RS-232C. PC (Serial port) (Serial port) RS-232C.. > > Multiple Display

More information

歯DCS.PDF

歯DCS.PDF DCS 1 DCS - DCS Hardware Software System Software & Application 1) - DCS System All-Mighty, Module, ( 5 Mbps ) Data Hardware : System Console : MMI(Man-Machine Interface), DCS Controller :, (Transmitter

More information

Microsoft Word - FS_ZigBee_Manual_V1.3.docx

Microsoft Word - FS_ZigBee_Manual_V1.3.docx FirmSYS Zigbee etworks Kit User Manual FS-ZK500 Rev. 2008/05 Page 1 of 26 Version 1.3 목 차 1. 제품구성... 3 2. 개요... 4 3. 네트워크 설명... 5 4. 호스트/노드 설명... 6 네트워크 구성... 6 5. 모바일 태그 설명... 8 6. 프로토콜 설명... 9 프로토콜 목록...

More information

untitled

untitled CLEBO PM-10S / PM-10HT Megapixel Speed Dome Camera 2/39 3/39 4/39 5/39 6/39 7/39 8/39 ON ON 1 2 3 4 5 6 7 8 9/39 ON ON 1 2 3 4 10/39 ON ON 1 2 3 4 11/39 12/39 13/39 14/39 15/39 Meg gapixel Speed Dome Camera

More information

2

2 2 3 4 5 6 7 8 9 10 11 60.27(2.37) 490.50(19.31) 256.00 (10.07) 165.00 111.38 (4.38) 9.00 (0.35) 688.00(27.08) 753.00(29.64) 51.94 (2.04) CONSOLE 24CH 32CH 40CH 48CH OVERALL WIDTH mm (inches) 1271.45(50.1)

More information

<BACEBDBAC5CD20BAEAB7CEBCC52D A2DC3D6C1BE2D312D E6169>

<BACEBDBAC5CD20BAEAB7CEBCC52D A2DC3D6C1BE2D312D E6169> DOOCH PUMP Intelligent pressure boosting system 5Hz BOOSTER PUMP SYSTEM Water supply system Pressure boosting system Irrigation system Water treatment system Industrial plants 두크펌프 www.doochpump.com CONTENTS

More information

untitled

untitled Huvitz Digital Microscope HDS-5800 Dimensions unit : mm Huvitz Digital Microscope HDS-5800 HDS-MC HDS-SS50 HDS-TS50 SUPERIORITY Smart Optical Solutions for You! Huvitz Digital Microscope HDS-5800 Contents

More information

Microsoft Word - Preliminary_ALT6600메뉴얼(M6600-K01C)160812

Microsoft Word - Preliminary_ALT6600메뉴얼(M6600-K01C)160812 OperationManual Smart Capacitance Level Transmitter ALT6600 Overview M6600-K01C Autrol ALT6600 Capacitance Level Transmitter 는마이크로프로세서기반으로한전송기로서측정물이지니고있는유전율을이용하여 Tank 내부의수위를측정하기위한최적의솔루션을제공한다. 프로브는탱크의벽과매체

More information

서보교육자료배포용.ppt

서보교육자료배포용.ppt 1. 2. 3. 4. 1. ; + - & (22kW ) 1. ; 1975 1980 1985 1990 1995 2000 DC AC (Ferrite) (NdFeB; ) /, Hybrid Power Thyrister TR IGBT IPM Analog Digital 16 bit 32 bit DSP RISC Dip SMD(Surface Mount Device) P,

More information

REVERSIBLE MOTOR 표지.gul

REVERSIBLE MOTOR 표지.gul REVERSIBLE MOTOR NEW H-SERIES REVERSIBLE MOTOR H-EX Series LEAD WIRE w RH 1PHASE 4 POLE PERFORMANCE DATA (DUTY : Min.) MOTOR OUTPUT VOLTAGE (V) FREQUENCY (Hz) INPUT CURRENT (ma) RATING SPEED (rpm) STARTING

More information

Elix 3 Elix 5 Elix 10 RiOs 3 RiOs 5 RiOs 8 RiOs 16!.. MILLIPORE

Elix 3 Elix 5 Elix 10 RiOs 3 RiOs 5 RiOs 8 RiOs 16!.. MILLIPORE Elix 3 Elix 5 Elix 10 RiOs 3 RiOs 5 RiOs 8 RiOs 16!.. MILLIPORE ...1...1 1....2 1-1... 2 1-2... 2 1-3... 3 1-4... 3 1-5... 4 1-6... 4 1-7... 5 1-8... 5 1-9... 6 2....7 2-1... 7 2-2... 7 2-3 Cl2 tablet...

More information

Parts List

Parts List COP 1440 Drifter Parts for Atlas Copco Atlas Copco No Crawler Drill Drfter Part Number Part Name Q'ty Unit Price Remarks 3115 1605 90 set of nipple 1set *} front head 3115 0286 00 dome nut 0.26kg 3115

More information

GLHPS-D

GLHPS-D Digital Hot Plate & Stirrer GLHPS-D 글로벌랩의 제품을 구입하여 주셔서 감사드립니다. 제품을 사용하시기 전에 안전을 위한 준비사항 을 읽고 올바르게 사용해 주십시오. 이 사용설명서는 제품을 직접 사용하시는 분에게 보내어지도록 하여 주십시오. 사용 전 주의 사항 제품을 올바르게 사용하여 위험이나 재산상의 피해를 막기 위한 내용으로 반드시

More information

CMSX-C-U-F1_BES_C_ b_ k1

CMSX-C-U-F1_BES_C_ b_ k1 8080774 07-b [80606] CMSX-...--C-U-F-..-KO : : :. / Festo 07-b ... 5.... 5... 5.... 5. Festo... 5... 6.... 6.... 6.... 8.4... 9.4. CMSX-P-S- -D- -A-G (, )... 0.4. CMSX-P-S- -D- -A, (, )... 0.4. CMSX-P-S-

More information

R50_51_kor_ch1

R50_51_kor_ch1 S/N : 1234567890123 Boot Device Priority NumLock [Off] Enable Keypad [By NumLock] Summary screen [Disabled] Boor-time Diagnostic Screen [Disabled] PXE OPROM [Only with F12]

More information

2005 2004 2003 2002 2001 2000 Security Surveillance Ubiquitous Infra Internet Infra Telematics Security Surveillance Telematics Internet Infra Solutions Camera Site (NETWORK) Monitoring & Control

More information

CPX-E-EC_BES_C_ _ k1

CPX-E-EC_BES_C_ _ k1 CPX-E CPX-E-EC EtherCAT 8071155 2017-07 [8075310] CPX-E-EC CPX-E-EC-KO EtherCAT, TwinCAT (). :, 2 Festo CPX-E-EC-KO 2017-07 CPX-E-EC 1... 4 1.1... 4 1.2... 4 1.3... 4 1.4... 5 1.5... 5 2... 6 2.1... 6

More information

INDUCTION MOTOR 표지.gul

INDUCTION MOTOR 표지.gul INDUCTION MOTOR NEW HSERIES INDUCTION MOTOR HEX Series LEAD WIRE TYPE w IH 1PHASE 4 POLE PERFORMANCE DATA (DUTY : CONTINUOUS) MOTOR TYPE IHPF10 IHPF11 IHPF IHPF22 IHPFN1U IHPFN2C OUTPUT 4 VOLTAGE

More information

Preliminary spec(K93,K62_Chip_081118).xls

Preliminary spec(K93,K62_Chip_081118).xls 2.4GHz Antenna K93- Series KMA93A2450X-M01 Antenna mulilayer Preliminary Spec. Features LTCC Based designs Monolithic SMD with small, low-profile and light-weight type Wide bandwidth Size : 9 x 3 x 1.0mm

More information

SSi Super Systems Inc 1 2 2 2 3-3 4 / 4 5 5 DP2000 11 RETURNING THE UNIT TO SSI 11 SPARE PARTS 12 APPENDIX A 13 APPENDIX B 14 Super System Inc DP2000

SSi Super Systems Inc 1 2 2 2 3-3 4 / 4 5 5 DP2000 11 RETURNING THE UNIT TO SSI 11 SPARE PARTS 12 APPENDIX A 13 APPENDIX B 14 Super System Inc DP2000 SSi Super Systems Inc Model DP 2000 : ( ) / / : -50 to +80 F (-47 to +27 C) : 0 to 120 F (-18 to +49 C) : 115/240 VAC 60Hz : LED Digital : +/- 1 F (+/- 01 C) : 4 20 ma ( ) : 12 V : 8 ( ): 11 x 10 x 7 :

More information

CPX-E-SYS_BES_C_ _ k1

CPX-E-SYS_BES_C_ _ k1 CPX-E 8727 27-7 [875294] CPX-E-SYS-KO CODESYS, PI PROFIBUS PROFINET (). :, 2 Festo CPX-E-SYS-KO 27-7 ... 5.... 5.2... 5.3... 5.4... 5.5... 5 2... 6 2.... 6 2..... 6 2..2 CPX-E... 7 2..3 CPX-E... 9 2..4...

More information

333474C - Reactor 2 E-30 and E-XP2, Repair-Parts, Korean

333474C - Reactor 2 E-30 and E-XP2, Repair-Parts, Korean 수리-부품 리액터2E-30및E-XP2프로 포셔닝 System 333474C KO 전기, 가열, 이액형 시스템 폴리우레탄 포움 스프레이 및 폴리우레아 코팅용. 전문가만 이 장비를 사용 할수 있습니다. 폭발 위험이 있는 환경 또는 유해한 장소에서 사용이 금지되어 있습니다. 중요 안전 정보이 설명서의 모든 경고와 지침을 읽으십시오. 이 지침 을 보관하십시오. PROVEN

More information

untitled

untitled CAN BUS RS232 Line Ethernet CAN H/W FIFO RS232 FIFO IP ARP CAN S/W FIFO TERMINAL Emulator COMMAND Interpreter ICMP TCP UDP PROTOCOL Converter TELNET DHCP C2E SW1 CAN RS232 RJ45 Power

More information

À̵¿·Îº¿ÀÇ ÀÎÅͳݱâ¹Ý ¿ø°ÝÁ¦¾î½Ã ½Ã°£Áö¿¬¿¡_.hwp

À̵¿·Îº¿ÀÇ ÀÎÅͳݱâ¹Ý ¿ø°ÝÁ¦¾î½Ã ½Ã°£Áö¿¬¿¡_.hwp l Y ( X g, Y g ) r v L v v R L θ X ( X c, Yc) W (a) (b) DC 12V 9A Battery 전원부 DC-DC Converter +12V, -12V DC-DC Converter 5V DC-AC Inverter AC 220V DC-DC Converter 3.3V Motor Driver 80196kc,PWM Main

More information

Microsoft Word - SRA-Series Manual.doc

Microsoft Word - SRA-Series Manual.doc 사 용 설 명 서 SRA Series Professional Power Amplifier MODEL No : SRA-500, SRA-900, SRA-1300 차 례 차 례 ---------------------------------------------------------------------- 2 안전지침 / 주의사항 -----------------------------------------------------------

More information

VZ94-한글매뉴얼

VZ94-한글매뉴얼 KOREAN / KOREAN VZ9-4 #1 #2 #3 IR #4 #5 #6 #7 ( ) #8 #9 #10 #11 IR ( ) #12 #13 IR ( ) #14 ( ) #15 #16 #17 (#6) #18 HDMI #19 RGB #20 HDMI-1 #21 HDMI-2 #22 #23 #24 USB (WLAN ) #25 USB ( ) #26 USB ( ) #27

More information

APOGEE Insight_KR_Base_3P11

APOGEE Insight_KR_Base_3P11 Technical Specification Sheet Document No. 149-332P25 September, 2010 Insight 3.11 Base Workstation 그림 1. Insight Base 메인메뉴 Insight Base Insight Insight Base, Insight Base Insight Base Insight Windows

More information

02 Reihe bis 750 bar GB-9.03

02 Reihe bis 750 bar GB-9.03 Water as a tool High-Pressure Plunger Pumps 02-Line (up to 750 bar) 252 702 1002 1502 1852 2502 Technical Data High-Pressure Plunger Pump Type 252 / 702 approx. 1.8 l approx. 50 kg net 45 mm/1.77 inch

More information

DIB-100_K(90x120)

DIB-100_K(90x120) Operation Manual 사용설명서 Direct Box * 본 제품을 사용하기 전에 반드시 방송방식 및 전원접압을 확인하여 사용하시기 바랍니다. MADE IN KOREA 2009. 7 124447 사용하시기 전에 사용하시기 전에 본 기기의 성능을 충분히 발휘시키기 위해 본 설명서를 처음부터 끝까지 잘 읽으시고 올바른 사용법으로 오래도록 Inter-M 제품을

More information

#KM560

#KM560 KM-560 KM-560-7 PARTS BOOK KM-560 KM-560-7 INFORMATION A. Parts Book Structure of Part Book Unique code by mechanism Unique name by mechanism Explode view Ref. No. : Unique identifcation number by part

More information

# KM

# KM PARTS BOOK 1-NEEDLE, STRAIGHT LOCK-STITCH MACHINE WITH VERTICAL EDGE TRIMMER 1-NEEDLE, NEEDLE FEED LOCK-STITCH MACHINE WITH VERTICAL EDGE TRIMMER MODEL KM-506 SERIES KM-506-7S 1-NEEDLE, STRAIGHT LOCK-STITCH

More information

( Full Automatic Printer ) 작용업종 : Tube Light ( 형광등 1.2m / 2.4m) 가로등조명. 인테리어산업용조명 Loader 1.2m Stencil Solder LED LD812V Reflow 8 to 10 Hot Air Convecti

( Full Automatic Printer ) 작용업종 : Tube Light ( 형광등 1.2m / 2.4m) 가로등조명. 인테리어산업용조명 Loader 1.2m Stencil Solder LED LD812V Reflow 8 to 10 Hot Air Convecti Autotronik-SMT GmbH LED Assembly 위한장비구성도 Printer LED Pick & Place Reflow V-Cutting Model 1 1.2m Tube LED " 양산 " 장비 Full Vision Auto Printer 1.2m LED Pick & Place LED Reflow 10 Zone LED Multi V-Cutting

More information

YD-3533.xls

YD-3533.xls Y D - 3 5 3 3 사 용 설 명 서 78, Daechun-Dong, Dalseo-gu, Daegu, KOREA TEL : +8-53-585-56(Main) FAX : +8-53-585-788 http://www.setech.co.kr e-mail : setech@setech.co.kr 페이지 . 특징 당사의 제품을 사용하여 주셨어 감사하며, 사용중 혹시라도

More information

Vertical Probe Card Technology Pin Technology 1) Probe Pin Testable Pitch:03 (Matrix) Minimum Pin Length:2.67 High Speed Test Application:Test Socket

Vertical Probe Card Technology Pin Technology 1) Probe Pin Testable Pitch:03 (Matrix) Minimum Pin Length:2.67 High Speed Test Application:Test Socket Vertical Probe Card for Wafer Test Vertical Probe Card Technology Pin Technology 1) Probe Pin Testable Pitch:03 (Matrix) Minimum Pin Length:2.67 High Speed Test Application:Test Socket Life Time: 500000

More information

SRC PLUS 제어기 MANUAL

SRC PLUS 제어기 MANUAL ,,,, DE FIN E I N T R E A L L O C E N D SU B E N D S U B M O TIO

More information

기능.PDF

기능.PDF 1 1) 1 2) SK COMPLEX 1 Heating Cooling 3) 1 2 2 3 1) 2 2) 3 4 1) Floating Type Heat Exchanger 8 2) Fixed Type Heat Exchanger 11 3) U-Type Heat Exchanger 13 4) Air Fan Cooler 15 5) Double Pipe Heat Exchanger

More information

歯AG-MX70P한글매뉴얼.PDF

歯AG-MX70P한글매뉴얼.PDF 120 V AC, 50/60 Hz : 52 W (with no optional accessories installed), indicates safety information. 70 W (with all optional accessories installed) : : (WxHxD) : : 41 F to 104 F (+ 5 C to + 40 C) Less than

More information

5. Kapitel URE neu

5. Kapitel URE neu URE Fuses for Semiconductor Protection European-British Standard Standards: IEC 60 269-4 BS 88-4 Class: ar Voltage ratings: AC 240 V AC 700 V Current ratings: 5 A 900 A Features / Benefits High interrupting

More information

RC /07.12 RC / /6 2 3 / CA-08A-2N 2 CA-10A-2N 2 CA-12A-2N 2 CA-16A-2N 2 CA-20A-2N CA-08A-3N 4 CA-10A-3N 4 CA-12A-3N

RC /07.12 RC / /6 2 3 / CA-08A-2N 2 CA-10A-2N 2 CA-12A-2N 2 CA-16A-2N 2 CA-20A-2N CA-08A-3N 4 CA-10A-3N 4 CA-12A-3N RC 18325-70/07.12 RC 18325-70/02.10 1/6 2 3 / 3 4 2 CA-08A-2N 2 CA-10A-2N 2 CA-12A-2N 2 CA-16A-2N 2 CA-20A-2N 2 2 3 CA-08A-3N 4 CA-10A-3N 4 CA-12A-3N 4 CA-16A-3N 4 CA-20A-3N 4 4 3 CA-08A-3C 3 CA-10A-3C

More information

Slide 1

Slide 1 Clock Jitter Effect for Testing Data Converters Jin-Soo Ko Teradyne 2007. 6. 29. 1 Contents Noise Sources of Testing Converter Calculation of SNR with Clock Jitter Minimum Clock Jitter for Testing N bit

More information

비어 있음

비어 있음 VYPYR. VYPYR 15 VYPYR 120,. 43 Peavey. VYPYR., " ". TransTube " ", 266MHz SHARC. VYPYR 5,.,,. VYPYR. AC. IEC ( )... : 24 "( 30cm). 0 - Input. 1 - Stompbox Encoder VYPYR15.. 11.!. 2 - Amp Encoder.. 2. LED

More information

CD-RW_Advanced.PDF

CD-RW_Advanced.PDF HP CD-Writer Program User Guide - - Ver. 2.0 HP CD-RW Adaptec Easy CD Creator Copier, Direct CD. HP CD-RW,. Easy CD Creator 3.5C, Direct CD 3.0., HP. HP CD-RW TEAM ( 02-3270-0803 ) < > 1. CD...3 CD...5

More information

H3050(aap)

H3050(aap) USB Windows 7/ Vista 2 Windows XP English 1 2 3 4 Installation A. Headset B. Transmitter C. USB charging cable D. 3.5mm to USB audio cable - Before using the headset needs to be fully charged. -Connect

More information

........(2006)-01

........(2006)-01 플러그 U-패킹 세면기(도기) 삼각패킹 와샤 프렌지 너트 고정너트 세면기(도기) 프렌지 너트 와샤 고정너트 몸통 파이프 연결너트 가로대 연결대 스크류 폽업로드 5mm 노브 물마개 플러그 삼각패킹 U-패킹 U-클립 세면기(도기) 프렌지 너트 고정너트 몸통 파이프 연결너트 가로대 폽업로드 5mm 노브 물마개 플러그 삼각패킹 U-패킹 U-클립 와샤 벽면 벽면 Ø6

More information

E010 CYLINDER BLOCK GROUP (0 01) 76

E010 CYLINDER BLOCK GROUP (0 01) 76 E010 CYLINDER BLOCK GROUP (0 01) 75 E010 CYLINDER BLOCK GROUP (0 01) 76 E020 PISTON, CRANKSHAFT GROUP (0 02) 77 E030 CYLINDER HEAD GROUP (0 03) 78 E040 ROCKER ARM GROUP (0 04) 79 E050 TIMING CASE GROUP

More information

T100MD+

T100MD+ User s Manual 100% ) ( x b a a + 1 RX+ TX+ DTR GND TX+ RX+ DTR GND RX+ TX+ DTR GND DSR RX+ TX+ DTR GND DSR [ DCE TYPE ] [ DCE TYPE ] RS232 Format Baud 1 T100MD+

More information

Å©·¹Àγ»Áö20p

Å©·¹Àγ»Áö20p Main www.bandohoist.com Products Wire Rope Hoist Ex-proof Hoist Chain Hoist i-lifter Crane Conveyor F/A System Ci-LIFTER Wire Rope Hoist & Explosion-proof Hoist Mono-Rail Type 1/2ton~20ton Double-Rail

More information

#KM-350AB..

#KM-350AB.. PARTS BOOK KM-350A-7S KM-350A-7N KM-350B-7S KM-350B-7N KM-350A KM-350B PARTS BOOK KM-350A-7S KM-350A-7N KM-350B-7S KM-350B-7N KM-350A KM-350B PME-051121 MODEL FOR THIN MATERIAL KM-350A-7S 1-NEEDLE, NEEDLE

More information

,,,,,, (41) ( e f f e c t ), ( c u r r e n t ) ( p o t e n t i a l difference),, ( r e s i s t a n c e ) 2,,,,,,,, (41), (42) (42) ( 41) (Ohm s law),

,,,,,, (41) ( e f f e c t ), ( c u r r e n t ) ( p o t e n t i a l difference),, ( r e s i s t a n c e ) 2,,,,,,,, (41), (42) (42) ( 41) (Ohm s law), 1, 2, 3, 4, 5, 6 7 8 PSpice EWB,, ,,,,,, (41) ( e f f e c t ), ( c u r r e n t ) ( p o t e n t i a l difference),, ( r e s i s t a n c e ) 2,,,,,,,, (41), (42) (42) ( 41) (Ohm s law), ( ),,,, (43) 94 (44)

More information

목차 제 1 장 inexio Touch Driver소개... 3 1.1 소개 및 주요 기능... 3 1.2 제품사양... 4 제 2 장 설치 및 실행... 5 2.1 설치 시 주의사항... 5 2.2 설치 권고 사양... 5 2.3 프로그램 설치... 6 2.4 하드웨

목차 제 1 장 inexio Touch Driver소개... 3 1.1 소개 및 주요 기능... 3 1.2 제품사양... 4 제 2 장 설치 및 실행... 5 2.1 설치 시 주의사항... 5 2.2 설치 권고 사양... 5 2.3 프로그램 설치... 6 2.4 하드웨 최종 수정일: 2010.01.15 inexio 적외선 터치스크린 사용 설명서 [Notes] 본 매뉴얼의 정보는 예고 없이 변경될 수 있으며 사용된 이미지가 실제와 다를 수 있습니다. 1 목차 제 1 장 inexio Touch Driver소개... 3 1.1 소개 및 주요 기능... 3 1.2 제품사양... 4 제 2 장 설치 및 실행... 5 2.1 설치 시

More information

Smart-UPS On-Line 230 V UPS apc.com/kr

Smart-UPS On-Line 230 V UPS apc.com/kr Smart-UPS On-Line 230 V UPS apc.com/kr apc.com/kr 2 UPS Smart-UPS On-Line, /,. Smart-UPS On-Line / 5kVA~10kVA. 6kVA, 8kVA 10kVA. Smart-UPS On-Line. PowerChute Network Shutdown,. Smart-UPS On- Line,,,.

More information

Remote UI Guide

Remote UI Guide Remote UI KOR Remote UI Remote UI PDF Adobe Reader/Adobe Acrobat Reader. Adobe Reader/Adobe Acrobat Reader Adobe Systems Incorporated.. Canon. Remote UI GIF Adobe Systems Incorporated Photoshop. ..........................................................

More information

airDACManualOnline_Kor.key

airDACManualOnline_Kor.key 5F InnoValley E Bldg., 255 Pangyo-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea (Zip 463-400) T 031 8018 7333 F 031 8018 7330 airdac AD200 F1/F2/F3 141x141x35 mm (xx) 350 g LED LED1/LED2/LED3 USB RCA

More information

CD-6208_SM(new)

CD-6208_SM(new) Digital Amplifier MA-110 CONTENTS Specifications... 1 Electrical parts list... 2 top and bottom view of p.c. board... 10 Application... 12 block Diagram... 13 Schematic Diagram... 14 Exploded view of cabinet

More information

. "" "",.... :...,,....,.. :..,,,..,,...,.... 2

.  ,.... :...,,....,.. :..,,,..,,...,.... 2 RD-5405 /.. . "" "",.... :...,,....,.. :..,,,..,,...,.... 2 ..,,..,.. (,,,, )......,...,., ( ),,,,.,. (, )..,...... BD/DVD CD TV, VCR,........ (+, -).,,..... 3 ... 2... 3....3... 5... 9... 10...11...11...

More information

PRO1_09E [읽기 전용]

PRO1_09E [읽기 전용] Siemens AG 1999 All rights reserved File: PRO1_09E1 Information and - ( ) 2 3 4 5 Monitor/Modify Variables" 6 7 8 9 10 11 CPU 12 Stop 13 (Forcing) 14 (1) 15 (2) 16 : 17 : Stop 18 : 19 : (Forcing) 20 :

More information

DDX4038BT DDX4038BTM DDX4038 DDX4038M 2010 Kenwood Corporation All Rights Reserved. LVT A (MN)

DDX4038BT DDX4038BTM DDX4038 DDX4038M 2010 Kenwood Corporation All Rights Reserved. LVT A (MN) DDX4038BT DDX4038BTM DDX4038 DDX4038M 2010 Kenwood Corporation All Rights Reserved. LVT2201-002A (MN) 2 3 [ ] CLASS 1 LASER PRODUCT 4 1 2 Language AV Input R-CAM Interrupt Panel Color Preout

More information

대경테크종합카탈로그

대경테크종합카탈로그 The Series Pendulum Impact 601 & 602 Analog Tester For Regular DTI-602B (Izod) DTI-601 (Charpy) DTI-602A (Izod) SPECIFICATIONS Model DTI-601 DTI-602 Type Charpy for plastics lzod for plastics Capacity

More information

10X56_NWG_KOR.indd

10X56_NWG_KOR.indd 디지털 프로젝터 X56 네트워크 가이드 이 제품을 구입해 주셔서 감사합니다. 본 설명서는 네트워크 기능 만을 설명하기 위한 것입니다. 본 제품을 올바르게 사 용하려면 이 취급절명저와 본 제품의 다른 취급절명저를 참조하시기 바랍니다. 중요한 주의사항 이 제품을 사용하기 전에 먼저 이 제품에 대한 모든 설명서를 잘 읽어 보십시오. 읽은 뒤에는 나중에 필요할 때

More information

Microsoft PowerPoint - Powertrain_Sensor

Microsoft PowerPoint - Powertrain_Sensor Manifold Absolute Pressure(Temperature) Sensor Manifold Absolute Pressure (Temperature) Sensor measures the pressure (temperature) of intake manifold for calculating indirectly the intake air flow quantity

More information

Microsoft PowerPoint - ch03ysk2012.ppt [호환 모드]

Microsoft PowerPoint - ch03ysk2012.ppt [호환 모드] 전자회로 Ch3 iode Models and Circuits 김영석 충북대학교전자정보대학 2012.3.1 Email: kimys@cbu.ac.kr k Ch3-1 Ch3 iode Models and Circuits 3.1 Ideal iode 3.2 PN Junction as a iode 3.4 Large Signal and Small-Signal Operation

More information

<313630313032C6AFC1FD28B1C7C7F5C1DF292E687770>

<313630313032C6AFC1FD28B1C7C7F5C1DF292E687770> 양성자가속기연구센터 양성자가속기 개발 및 운영현황 DOI: 10.3938/PhiT.25.001 권혁중 김한성 Development and Operational Status of the Proton Linear Accelerator at the KOMAC Hyeok-Jung KWON and Han-Sung KIM A 100-MeV proton linear accelerator

More information

- 2 -

- 2 - - 1 - - 2 - 전기자동차충전기기술기준 ( 안 ) - 3 - 1 3 1-1 3 1-2 (AC) 26 1-3 (DC) 31 2 37 3 40-4 - 1 14, 10,, 2 3. 1-1 1. (scope) 600 V (IEC 60038) 500 V. (EV : Electric Vehicle) (PHEV : Plug-in Hybrid EV).. 2. (normative

More information

<453A5C736F6E67616D656E675CBBE7BFEBBCB3B8EDBCAD26C4ABB4D9B7CF2E2E2E>

<453A5C736F6E67616D656E675CBBE7BFEBBCB3B8EDBCAD26C4ABB4D9B7CF2E2E2E> 휴대용가스누설검지기 사 용 설 명 서 Model SP-210 측정가스 : 천연가스, 일반가연성가스, 도시가스/LPG 측정범위 : 10~10,000ppm Note 측정기기를 작동하기 전에 이 사용설명서를 주의 깊게 읽으십시오. 이 사용설명서를 필요시 언제라도 이용할 수 있는 곳에 보관하십시오. 이 가스측정기는 여기에 기술되지 않은 그 밖의 목적으로 사용할 수

More information

2 3

2 3 Micro Hi-Fi System MCM720 2 3 AC 5 14 5 14 MW MP3 5 14 MP3 5 14 FM CD 15 ISO9660, Joliet, Multisession 15 15 6-7 MP3 VBR non- 16 MP3 7 32kHz, 44.1kHz, 48kHz 16-17 non- 32, 64, 96, 128, 192, 256 (Kbps)

More information

歯국문-Heatran소개자료1111.PDF

歯국문-Heatran소개자료1111.PDF Heat Transfer Technology Heat Transfer Technology HEATRAN Heat Transfer Technology 1. 회사개요 Heat Transfer Technology Heat Transfer Technology Heat Transfer Technology Heat Transfer Technology Heat Transfer

More information

01KRCOV-KR

01KRCOV-KR 4-234-236-71(1) Mini Hi-Fi Component System MHC-RG60 MHC-DX30/RG40 MHC-DX20/RG30 2001 Sony Corporation 1 1 (CLASS 1 LASER), 1 (CLASS 1 LASER PRODUCT MARKING) 2 4 5 CD 6 R6 (AA ) 8 8 8 CD 9 CD / / 9 CD

More information

#KM857/867..

#KM857/867.. PARTS BOOK KM-857 KM-857-7 KM-867 KM-867-7 PME-051214 MODEL KM-857 HIGH SPEED POST BED, 1- NEEDLE NEEDLE FEED LOCK STITCH MACHINE KM-857-7 HIGH SPEED POST BED, 1- NEEDLE NEEDLE FEED LOCK STITCH MACHINE

More information

4 CD Construct Special Model VI 2 nd Order Model VI 2 Note: Hands-on 1, 2 RC 1 RLC mass-spring-damper 2 2 ζ ω n (rad/sec) 2 ( ζ < 1), 1 (ζ = 1), ( ) 1

4 CD Construct Special Model VI 2 nd Order Model VI 2 Note: Hands-on 1, 2 RC 1 RLC mass-spring-damper 2 2 ζ ω n (rad/sec) 2 ( ζ < 1), 1 (ζ = 1), ( ) 1 : LabVIEW Control Design, Simulation, & System Identification LabVIEW Control Design Toolkit, Simulation Module, System Identification Toolkit 2 (RLC Spring-Mass-Damper) Control Design toolkit LabVIEW

More information

歯동작원리.PDF

歯동작원리.PDF UPS System 1 UPS UPS, Converter,,, Maintenance Bypass Switch 5 DC Converter DC, DC, Rectifier / Charger Converter DC, /, Filter Trouble, Maintenance Bypass Switch UPS Trouble, 2 UPS 1) UPS UPS 100W KVA

More information

Microsoft Word - CL5000,5500_KOR_UM_20110321_.doc

Microsoft Word - CL5000,5500_KOR_UM_20110321_.doc 2 차 례 1. 주의 사항... 8 1.1 취급주의... 8 2. Specification... 10 2.1 소개... 10 2.2 규격... 12 3. 명칭과 기능... 14 3.1 CL 5000 - P Type... 14 3.2 기본 설치... 18 3.3 표시부... 19 3.4 기능키... 20 3.5 라벨롤의 설치... 24 4. PROGRAMMING...

More information

PL E-Euro-V01.pmd

PL E-Euro-V01.pmd Price List valid from 1st of March 2009 English 1/2009 The Profile System Order comments Article-Number - additional specification.60 definines 1 bar of aluminium profile, length 6 m Example: 1.09.016040.14LP.60

More information