Microsoft PowerPoint - 1-1 원전 전력계통의 전력품질 영향과 규제적용 방안_김문영(KINS) [호환 모드]



Similar documents
untitled

untitled

03 장태헌.hwp

PowerChute Personal Edition v3.1.0 에이전트 사용 설명서

- 2 -

전력량계 기술기준 일부개정(안).hwp

example code are examined in this stage The low pressure pressurizer reactor trip module of the Plant Protection System was programmed as subject for

2

-

DC Link Application DC Link capacitor can be universally used for the assembly of low inductance DC buffer circuits and DC filtering, smoothing. They

박선영무선충전-내지

(Table of Contents) 2 (Specifications) 3 ~ 10 (Introduction) 11 (Storage Bins) 11 (Legs) 11 (Important Operating Requirements) 11 (Location Selection)

1.장인석-ITIL 소개.ppt

PowerPoint 프레젠테이션

레이아웃 1

RFID USN_K_100107

Microsoft Word - 1-차우창.doc

2013<C724><B9AC><ACBD><C601><C2E4><CC9C><C0AC><B840><C9D1>(<C6F9><C6A9>).pdf

Validation Plan Template

Microsoft PowerPoint - ch03ysk2012.ppt [호환 모드]

intro


강의지침서 작성 양식

_20010~1.PDF

00내지1번2번

5. Kapitel URE neu

< C6AFC1FD28B1C7C7F5C1DF292E687770>

제 출 문 문화체육관광부장관 귀하 본 보고서를 문화예술분야 통계 생산 및 관리 방안 연구결과 최종 보고서로 제출합니다. 2010년 10월 숙명여자대학교 산학협력단 본 보고서는 문화체육관광부의 공식적인 견해와 다를 수 있습니다

ISO17025.PDF

µðÇÃ24-Ç¥Áö´Ü¸é

<BACEBDBAC5CD20BAEAB7CEBCC52D A2DC3D6C1BE2D312D E6169>

전기정보 11월(내지).qxp

슬라이드 제목 없음

DBPIA-NURIMEDIA

DBPIA-NURIMEDIA

2012 kicte??????????1223

Voice Portal using Oracle 9i AS Wireless

<30362E20C6EDC1FD2DB0EDBFB5B4EBB4D420BCF6C1A42E687770>

08 권준혁.hwp

산업입지내지6차

Bluetooth

THE JOURNAL OF KOREAN INSTITUTE OF ELECTROMAGNETIC ENGINEERING AND SCIENCE Jun.; 29(6),

How we create value? 안전경영 조직 및 시스템 강화 위원장 위원 간사 CEO 전략사장, CFO, 인사지원실장, 사업부장, 사업장장 안전환경인프라팀장 삼성SDI는 안전사고의 위험성에 대비하고 안전한 근무환경을 조성하기 위해 전담부서 개 편과 업무 관리범위

PROCES-WP012A-KO-P, 현재의 안전 계측 시스템(SIS)이 최신 표준을 준수하고 있습니까?

(Exposure) Exposure (Exposure Assesment) EMF Unknown to mechanism Health Effect (Effect) Unknown to mechanism Behavior pattern (Micro- Environment) Re

<313920C0CCB1E2BFF82E687770>

Microsoft Word - KSR2015A135

02Á¶ÇýÁø

DIB-100_K(90x120)

Microsoft Power Point 2002

감사칼럼 (제131호) 다. 미국과 일본의 경제성장률(전기 대비)은 2010년 1/4분기 각각 0.9%와1.2%에서 2/4분기에는 모두 0.4%로 크게 둔화 되었다. 신흥국들도 마찬가지이다. 중국, 브라질 등 신흥국은 선진국에 비해 높은 경제성장률을 기

untitled

S A e p u t e g m u s b te r C O N T E N T S

VXS-A-C1.eps

2015 본쥬 아이티 핸드북2

THE JOURNAL OF KOREAN INSTITUTE OF ELECTROMAGNETIC ENGINEERING AND SCIENCE Aug.; 30(8),

Analyses the Contents of Points per a Game and the Difference among Weight Categories after the Revision of Greco-Roman Style Wrestling Rules Han-bong

??윕햳??

<4D F736F F F696E74202D2028B9DFC7A5BABB2920C5C2BEE7B1A420B8F0B5E220C8BFC0B220BDC7C1F520BDC3BDBAC5DB5FC7D1B1B94E4920C0B1B5BFBFF85F F726C F72756D>

Microsoft Word - Installation and User Manual_CMD V2.2_.doc

<333920B3EBB4EBBCAE2DC0FABED0B9E8C0FCBCB1B7CEBFA120BFACB0E8B5C820BAD0BBEAC0FCBFF8C0C720B0FAB5B5C6AFBCBA2E687770>

½Éº´È¿ Ãâ·Â

熔断器

PowerPoint 프레젠테이션

Microsoft Word - SRA-Series Manual.doc

개인용전기자극기의 안전성및성능평가가이드라인

DBPIA-NURIMEDIA

세종대 요람

Microsoft PowerPoint - EMC 규격 가이드.ppt

년 충 남 지 역 어 조 사 보 고 서 국 립 국 어 원

Microsoft PowerPoint - 뉴스레터_2015년 9월

SURGE PROTECTIVE DEVICE 전원 전원 전원 +E +E +N+E

주요국 에너지 Profile 분석_아랍에미리트

232 도시행정학보 제25집 제4호 I. 서 론 1. 연구의 배경 및 목적 사회가 다원화될수록 다양성과 복합성의 요소는 증가하게 된다. 도시의 발달은 사회의 다원 화와 밀접하게 관련되어 있기 때문에 현대화된 도시는 경제, 사회, 정치 등이 복합적으로 연 계되어 있어 특

??

< D28B9F8BFAA20BCF6C1A4BABB292E687770>

LSC_NEK_Cover_03

D102005X0KR_May18


단선도 문제점

<C1DF3320BCF6BEF7B0E8C8B9BCAD2E687770>

제목없음

<23C0B1C1A4B9E65FC6EDC1FDBFCFBCBA E687770>

04-다시_고속철도61~80p

2016년 5월호 E 세계로, 미래로 나아가는 힘. nergy 우리의 열정과 노력이 KEPCO E&C의 에너지를 만들어냅니다. C ommunication 더 현명하게, 더 여유롭게 더 건강하게, 더 적극적으로 이 세상과 소통합니다. 04 K-Message 경영 메시지

72129o

*28I월호11.7출력

#유한표지F

Sensitive Compartmented Information Facility (SCIF) and Special Access Program Facility (SAPF) Criteria

스마트 배선용_누전차단기_160222

<FEFF E002D B E E FC816B CBDFC1B558B202E6559E830EB C28D9>

KEEI ISSUE PAPER(Vol.1, No.6)

2015

사용시 기본적인 주의사항 경고 : 전기 기구를 사용할 때는 다음의 기본적인 주의 사항을 반드시 유의하여야 합니다..제품을 사용하기 전에 반드시 사용법을 정독하십시오. 2.물과 가까운 곳, 욕실이나 부엌 그리고 수영장 같은 곳에서 제품을 사용하지 마십시오. 3.이 제품은

Contents I II Project Overview 상황분석 및 여건진단 II-1 문화재청 정책 및 사업 분석 II-2 II-3 문화재청 정책 커뮤니케이션 분석 문화재청 일반인식 분석 III 조직분석 및 사례 연구 III-1 문화재청 홍보 조직 및 예산 분석 III

목 차 Ⅰ. 정보기술의 환경 변화 Ⅱ. 차량-IT Convergence Ⅲ. 차량 센서 연계 서비스 Ⅳ. 차량-IT 융합 발전방향

?뗡뀶?믟뀱?솽꼶?듄꼮??

¾Èµ¿±³È¸º¸ÃÖÁ¾

¾Ë±â½¬¿îÀ±¸®°æ¿µc03ÖÁ¾š

#³óÃÌ°æÁ¦ 64È£-Ä®¶ó¸é

Transcription:

제 9 회 원전 전력계통 안전성증진 워크샵 원전 전력계통의 전력품질 영향과 규제적용 방안 전기제어실 김 문 영 mykim@kins.re.kr

Contents 1 Introduction and Background 2 Power Quality, requirement and standards 3 Voltage Sag 4 System model 5 SLG, LLG, LLL 6 Multi-stage voltage sag 7 Regulatory Position KOREA INSTITUTE OF NUCLEAR SAFETY - 1 -

Introduction 전력계통의 상황은 전원 및 부하의 변동이 항상 존재. 예상하지 못한 지락, 단락의 전기적 사고로 과도상태가 빈번히 발생. 예상하지 못한 전기적 사고 및 전기적 과도상태는 원전 위험도에 중대한 영 향을 끼칠 수 있음. 최근에 전기적 과도상태 파급에 따른 전력품질 문제가 많이 증가하고 있는 추세이며 중요하게 고려해야 할 대상임. KOREA INSTITUTE OF NUCLEAR SAFETY - 2 -

Background 원전 안전설비는 계측 및 제어 기기에서부터 펌프 및 밸브를 구동하는 전동기 까지 여러 설비로 구성됨. 안전설비의 동작을 위해 안정적인 필수전원을 공급하는 안전관련 모선이 전기 적인 과도현상의 영향으로 순간적인 문제가 발생되면, 원전에 안전기능을 담당하는 기기에 영향을 주게 되어 제시간에 정상적인 운전 이 불가능할 경우, 원전 위험도는 증가될 가능성이 높음. 따라서 다양한 전기적 사고들에 기인한 전기적 과도상태에 따른 안전관련 모선 의 영향과 그에 따른 안전관련 부하를 구동하는 전동기의 운전특성에 미치는 영향을 분석하는 것은 매우 중요함. KOREA INSTITUTE OF NUCLEAR SAFETY - 3 -

Power Quality 과거 계속적인 (무정전의) 전기 공급이 최우선 전력 소비 및 부하의 변화 현재와 미래 높은 공급 신뢰도뿐 아니라 양질의 전기에 대한 수요 급증 Good Quality Poor Quality KOREA INSTITUTE OF NUCLEAR SAFETY - 4 -

Sensitive equipment to PQ 산업별 전력품질에 민감한 기기 분류 % Source: EPRI Power Quality Applications and Advanced Distribution Automation, 2007 Joint Conference and Exhibition KOREA INSTITUTE OF NUCLEAR SAFETY - 5 -

PQ issues 과거에 비해 부하들의 민감도 증가 전력품질 저하를 야기하는 부하들의 증가 다양한 품질 문제에 대한 국내 발생 현황 파악 미비 전력소비자 보다는 공급자 중심의 계통 운영 및 계획 신재생 에너지원 확대 및 smart grid 등 계통 환경변화 대책 KOREA INSTITUTE OF NUCLEAR SAFETY - 6 -

PQ requirement SRP(2007) 8.3.1 Onsite AC Power Systems Variations in voltage, frequency and waveform (harmonic distortion) in the onsite power system and its components during any mode of plant operation should not degrade the performance of any safety system load below an acceptable level. IEEE Std. 308-1991, Criteria for Class 1E Power Systems for NPP. 5.5 Power Quality The variations of voltage, frequency, and waveform in the Class 1E power systems during any mode of plant operation shall not degrade the performance of any safety system load below an acceptable level. KOREA INSTITUTE OF NUCLEAR SAFETY - 7 -

PQ requirement IEEE Std. 308-2001 4.5 Power quality The variations of voltage, frequency, and waveform (including the effects of harmonic distortion) in the Class 1E power systems during any mode of plant operation shall not degrade the performance of any safety system load below an acceptable level. Particular attention should be paid to the effects of degraded grid conditions. SRP(1996) CH. 8 App. 8-A BTP PSB-1 SRP(2007) BTP 8-6 Adequacy of station electric distribution system voltages KOREA INSTITUTE OF NUCLEAR SAFETY - 8 -

PQ standards IEEE Std. 519 : IEEE Recommended Practices and Requirements for Harmonics Control in Electrical Power Systems IEEE Std. 1159 : IEEE Recommended Practice for Monitoring Electric Power Quality IEEE Std. 1250 : IEEE Guide for Service to Equipment Sensitive to Momentary Voltage Disturbances IEC 61000-2-2 : Compatibility levels for low-frequency conducted disturbances and signaling in public low-voltage power supply systems IEC 61000-4-11 : Voltage Dips, short Interruptions and voltage variations immunity tests KOREA INSTITUTE OF NUCLEAR SAFETY - 9 -

PQ standards Org. Std. Title / Scope ANSI/ IEEE ANSI/ IEEE 141 Industrial Electric Power Systems 142 Industrial & Commercial Power System Grounding 241 Commercial Electric Power Systems 242 Industrial & Commercial Power System Protection 399 Industrial & Commercial Power System Analysis 446 Industrial & Commercial Power System Emergency Power 493 Industrial & Commercial Power System Reliability 518 Control of Noise in Electronic Controls 519 Harmonics in Power Systems 602 Industrial & Commercial Power Systems in Health Facilities 739 Energy Conservation in Industrial Power Systems 929 Interconnection Practices for Photovoltaic Systems 1001 Interfacing Dispersed Storage and Generation 1035 Test Procedures for Interconnecting Static Power Converters 1050 Grounding of Power Station Instrumentation & Control C62 Guides & Standards on Surge Protection C84.1 Voltage Ratings for Power Systems & Equipment C37 Guides and Standards for Relaying & Overcurrent Protection C57.110 Transformer Derating for Supplying Nonlinear Loads P487 Wire Line Communication Protection in Power Stations 1100 Powering and Grounding Sensitive Equipment 1159 Monitoring and Definition of Electric Power Quality 1250 Guide on Equipment Sensitive to Momentary Voltage Disturbance 1346 Guide on Compatibility for ASDs and Process Controllers KOREA INSTITUTE OF NUCLEAR SAFETY - 10 -

PQ categories Transients Short-duration variations à Voltage sag, swell Long-duration variations à Under voltage, Over voltage Voltage unbalance Waveform distortion à Harmonics Voltage fluctuations à Flicker KOREA INSTITUTE OF NUCLEAR SAFETY - 11 -

Transient 200 Positive Oscillatory 100 0 100 200 Negative Transient, Spike, Surge, Impulse Impulse Transient : lightning Oscillatory Transient : capacitor banks, switching KOREA INSTITUTE OF NUCLEAR SAFETY - 12 -

Sag, Swell, Interruption Sag Swell Interruption 0 voltage sag : 0.1 ~ 0.9 P.U. 0.5 cycle - 1min. voltage swell : 1.1 ~ 1.8 P.U. 0.5 cycle - 1min. interruption : >0.1 P.U. 0.5 cycle - 1min. under voltage : 0.8 ~ 0.9 P.U. <1min. over voltage : 1.1 ~ 1.2 P.U. <1min. sustained interruption : >0.1 P.U. <1min. KOREA INSTITUTE OF NUCLEAR SAFETY - 13 -

Harmonics 고조파(Harmonics) : 기본 주파수(Fundamental frequency) 의 정수 배에 해당하는 주파수를 가지는 파형 일반적으로 고조파 왜곡(harmonic distortion)은 전력계통 부하의 비선형 특성에서 비롯 KOREA INSTITUTE OF NUCLEAR SAFETY - 14 -

Voltage Sag PQ event monitoring results by Electric Power Research Institute (EPRI) KOREA INSTITUTE OF NUCLEAR SAFETY - 15 -

System model target : KSNP, safety related bus(4.16kv and 480V) in onsite power system G SWYD fault types : SLG, LLG, LLL 22kV fault location : Train B 1E bus(f B ), 4.16kV UAT 1 UAT 2 Train A N1E bus(f N ) M Tr F N F B fault duration : 6 cycles 480V electrical data : FSAR M analysis tool : EMTP KOREA INSTITUTE OF NUCLEAR SAFETY - 16 -

SLG Ø 사고와 관련되는 A 상만이 모선 전압에서 파형과 크기가 저하되 는 전압 sag 현상이 발생 Ø B와 C 상은 사고의 영향을 받지 않아 건전하게 정상 전압파형을 유지 Ø 전동기의 경우, 사고 기간 동안 A 상에서 고정자 전류의 현저한 감 소로 공급전류 불평형 유발 KOREA INSTITUTE OF NUCLEAR SAFETY - 17 -

LLG Ø 사고와 관련되는 B, C상에서 모 선전압의 파형과 크기가 저하되 는 전압 sag 현상이 발생 Ø A 상은 사고의 영향을 받지 않아 건전하게 정상 전압파형 유지 Ø 사고 기간 동안 B, C 상에서 전동 기 고정자 전류의 현저한 감소와 사고의 영향을 받지 않는 A 상에 서 약간의 상승변화 Ø 공급전류 불평형은 전동기 권선 국부가열에 의한 열화소손 유발 KOREA INSTITUTE OF NUCLEAR SAFETY - 18 -

LLL Ø 모선전압 A, B, C 상 모두 균일하 게 크기가 저하되는 전압 sag 현 상이 발생 Ø 사고 해소 후 정상 전압으로 회복 Ø 사고 기간 동안 전동기 고정자 전 류의 감소와 상승으로 인한 전류 의 변화는 고정자 권선의 열적 변 화를 유발하여 열적 스트레스와 함께 권선의 열화 촉진과 잠재적 인 전동기 수명감소 영향 KOREA INSTITUTE OF NUCLEAR SAFETY - 19 -

Multi-stage voltage sag Ø multi-stage voltage sag : 최초 사 고 발생부터(SLG) 사고가 해소 되지 못하고 점차 진행되어(LLG) 이어지면서 지속적인 사고의 파 급으로(LLL) 발전되어 나타나는 전압저하 현상 Ø 전동기 고정자 전류변화도 사고 진행에 따라 상별 불평형이 더욱 크게 나타남. KOREA INSTITUTE OF NUCLEAR SAFETY - 20 -

Regulatory Position 정상, 비정상시 또는 전기적 과도상태시 안전관련 기기, 모선 또는 계통의 Variations in voltage, frequency and waveform (harmonic distortion) 감시할 수 있는 PQ monitoring 설비 설치 필요. Ø 전기적 사고 원인 규명 및 분석에 활용 소내 전력계통 설계시 또는 가동원전의 전력계통 설계변경시 PQ 변화에 대비를 위한 다양하고 포괄적인 분석 또는 시험 필요. Ø 전력계통의 취약부분에 관한 정보 획득 소내 전력계통 분석에 사용되는 해석 프로그램의 신뢰성 확보 필요. Ø Verification (test, historical data 등) Ø external quality insurance KOREA INSTITUTE OF NUCLEAR SAFETY - 21 -

Thank you for your attention! KOREA INSTITUTE OF NUCLEAR SAFETY - 22 -