Microsoft PowerPoint - WEOZMMFSBAGZ.ppt

Similar documents
시스코 무선랜 설치운영 매뉴얼(AP1200s_v1.1)


TTA Verified : HomeGateway :, : (NEtwork Testing Team)

歯Cablexpert제안서.PDF

ARMBOOT 1

() Aloha Netowrk ether(,, )network Ehternet, DEC, ( DIX(DEC, Intel, Xerox) IEEE(, ) 5 9,, (Xerox) (Bob Metcalfe), (, ) A

cam_IG.book

1.LAN의 특징과 각종 방식


LAN케이블링

Microsoft Word - ZIO-AP1500N-Manual.doc

1. GigE Camera Interface를 위한 최소 PC 사양 CPU : Intel Core 2 Duo, 2.4GHz이상 RAM : 2GB 이상 LANcard : Intel PRO/1000xT 이상 VGA : PCI x 16, VRAM DDR2 RAM 256MB

Assign an IP Address and Access the Video Stream - Installation Guide

歯A1.1함진호.ppt

PowerChute Personal Edition v3.1.0 에이전트 사용 설명서

Microsoft PowerPoint - ch03ysk2012.ppt [호환 모드]

Network seminar.key

PWR PWR HDD HDD USB USB Quick Network Setup Guide xdsl/cable Modem PC DVR 1~3 1.. DVR DVR IP xdsl Cable xdsl Cable PC PC DDNS (

USB USB DV25 DV25 REC SRN-475S REC SRN-475S LAN POWER LAN POWER Quick Network Setup Guide xdsl/cable Modem PC DVR 1~3 1.. DVR DVR IP xdsl Cable xdsl C

hd1300_k_v1r2_Final_.PDF

PowerPoint Presentation

1217 WebTrafMon II

untitled

untitled

歯AG-MX70P한글매뉴얼.PDF

chapter4

VZ94-한글매뉴얼

Microsoft PowerPoint - 06-IPAddress [호환 모드]

LDK-300 제안서

7782 WI-FI AP (5GHz/2.4GHz) RF 6dB / 15dB 4bB, af/at PoE(Power over Ethernet) 802.3af/at VAC GPS,, 2~4 IP 900Mbps (450Mbps/ ) 32 BSSID, QoS ** Q

bn2019_2

차례 1. 채널 메뉴 채널 정보 보기... 4 채널 메뉴 사용하기... 4 선호 채널 설정하기... 7 채널 기억하기... 7 기타 기능 기본 기능 화면 모드 변경하기... 9 화면 조정값 설정하기... 9 화면 크기 변경하기... 9 부가 설정 변경하기

TCP.IP.ppt

,,,,,, (41) ( e f f e c t ), ( c u r r e n t ) ( p o t e n t i a l difference),, ( r e s i s t a n c e ) 2,,,,,,,, (41), (42) (42) ( 41) (Ohm s law),

ez-shv manual

MR-3000A-MAN.hwp

Sena Device Server Serial/IP TM Version

airDACManualOnline_Kor.key

Network Security - Wired Sniffing 실습 ICNS Lab. Kyung Hee University

(SW3704) Gingerbread Source Build & Working Guide

?뗡뀶?믟뀱?솽꼶?듄꼮??

슬라이드 제목 없음


Microsoft Word - PEB08_USER_GUIDE.doc

Coriolis.hwp

BJFHOMINQJPS.hwp


CLX8380_KR.book

OfficeServ 솔루션 OfficeServ 솔루션 OfficeServ는 삼성전자의 기업형 IP 솔루션으로서 음성과 데이터, 유선과 무선이 융합된 미래 오피스형 솔루션입니다. OfficeServ 7400/7200 삼성전자가 다년간 쌓아 온 기간망 사업 경험 및 모바일


H3050(aap)

Microsoft PowerPoint - 2.Catalyst Switch Intrastructure Protection_이충용_V1 0.ppt [호환 모드]

소개 TeraStation 을 구입해 주셔서 감사합니다! 이 사용 설명서는 TeraStation 구성 정보를 제공합니다. 제품은 계속 업데이트되므로, 이 설명서의 이미지 및 텍스트는 사용자가 보유 중인 TeraStation 에 표시 된 이미지 및 텍스트와 약간 다를 수

ZoneFlex AP (1) : ZoneFlex T300 ZoneFlex T301s ZoneFlex T301n ZoneFlex T300e AP ( ), 180., 1"~4". 4". (1) : (1) : (2) M8 ( ) (4) SAE32,

05Àå

목차 Q-1. 데이터를 통한 음성통화가 되지 않습니다 Q-2. WiFi 연결이 안됩니다 Q-3. 인터넷 또는 네트워크 연결이 안됩니다 Q-4. 표준 부속품을 알려주시기 바랍니다 Q-5. 구입하였습니다만, 배터리는 어떻게 장착하

Windows 네트워크 사용 설명서

SLA QoS

슬라이드 1

Microsoft Word - FS_ZigBee_Manual_V1.3.docx

QSE-CI-AP-D.xlsx

본교재는수업용으로제작된게시물입니다. 영리목적으로사용할경우저작권법제 30 조항에의거법적처벌을받을수있습니다. [ 실습 ] 스위치장비초기화 1. NVRAM 에저장되어있는 'startup-config' 파일이있다면, 삭제를실시한다. SWx>enable SWx#erase sta

INDUCTION MOTOR 표지.gul

Backup Exec

DC Link Application DC Link capacitor can be universally used for the assembly of low inductance DC buffer circuits and DC filtering, smoothing. They

acdc EQ 충전기.hwp

REVERSIBLE MOTOR 표지.gul

ez-md+_manual01

歯DCS.PDF

박선영무선충전-내지

StruxureWare Data Center Expert 7.2.x 의 새 기능 StruxureWare Data Center Expert 7.2.x 릴리스에서 사용할 수 있는 새 기능에 대해 자세히 알아보십시오. 웹 클라이언트 시작 화면: StruxureWare Cen

10X56_NWG_KOR.indd

This page left blank intentionally

untitled

SMB_ICMP_UDP(huichang).PDF

슬라이드 1

Chapter11OSPF

°í¼®ÁÖ Ãâ·Â

PD-659_SM(new)

2 PX-8000과 RM-8000/LM-8000등의 관련 제품은 시스템의 간편한 설치와 쉬운 운영에 대한 고급 기술을 제공합니다. 또한 뛰어난 확장성으로 사용자가 요구하는 시스템을 손쉽게 구현할 수 있습니다. 메인컨트롤러인 PX-8000의 BGM입력소스를 8개의 로컬지

R50_51_kor_ch1


온라인등록용 메뉴얼

GLOFA Series Cnet

김기남_ATDC2016_160620_[키노트].key

UDP Flooding Attack 공격과 방어

Contents I. 칼라스 네트워크 플레이어란 1. Pc-Fi를 넘어서 발전한 차세대 음악 플레이어 칼라스 네트워크 플레이어의 장점 3. 시스템 기본 구성

1_12-53(김동희)_.hwp

PCServerMgmt7

Microsoft Word - release note-VRRP_Korean.doc

APOGEE Insight_KR_Base_3P11

vm-웨어-앞부속

ICM-ETHi/User Guide

제20회_해킹방지워크샵_(이재석)

Smart IO_K_121108

Category Index Category Page# Category Page# Category Page# 94 Connectors Banana Plugs & Jacks [see separate Banana Plugs & Jacks section]

DBPIA-NURIMEDIA

歯동작원리.PDF

개요

한글사용설명서

Transcription:

PoE 기술 (POWER over ETHERNET) 2010.04.23

PoE(Power over Ethernet) 란? ㅇ PoE는 " 액티브이더넷 " 이라고도불리며, 이는무선 AP나기타유선 LAN에사용되는네트웍장비들에전원 ( 전력 ) 을별도공급할필요가없이이더넷케이블하나에데이터와전원 ( 전력 ) 을동시에보낼수있는기술을말한다 PoE 구성 ㅇ PoE는전원을네트웍케이블에공급하는인젝터에서시작되는데, 인젝터는대개이더넷스위치나허브의근처에설치된다. 일부무선AP와네트웍장비들은네트웍케이블로부터자신의 RJ-45 잭을통해전원을직접받아들인다. 이러한장비들을 "PoE 호환 " 또는 " 액티브이더넷호환 " 장비라고부른다. ㅇ PoE 호환장비가아닌경우에는 "DC 픽커 " 또는 " 탭 라고불리는방법을통해 PoE로변환시킬수있다. 이러한것들은액티브이더넷을위한 " 스플리터 라고불리기도한다. 이장비들은네트웍케이블에실려있는직류전원을분리해내서일반직류전원잭을통해장비에공급. 그러므로, PoE를사용하려면, ( 인젝터 ) + (PoE 호환장비 ) 또는 ( 인젝터 ) + (PoE에호환되지않는장비 ) + ( 픽커 ) 형식의구성이필요

PoE 의장점 ㅇ PoE는보다지능적인전원공급 - PoE를이용한전원공급은 SNMP와같은기존의네트워크관리프로토콜을이용하여보다차원높은시스템관리가가능. - 네트워크를통해보안감시관리자가전원을차단하거나재공급이가능. - 과부하누전으로부터자동보호 ㅇ PoE 는보다간편하고 비용절감효과 - PoE 허브 ( 종종미드스팬-Mid-spans으로불리기도함 ) 를통한중앙집중식전원공급은중앙집중식 UPS 시스템과연결을하면메인전원이차단되어도 UPS에의해미드스팬허브에연결된모든네트워크카메라가자동적으로동작이되어만약의사태에도지속적인영상감시카메라로서의역할을수행합니다. 기존의전원아웃렛의영향으로부터자유로우며 PD(POWERED DEVICE) 설치를위한전원어댑터도전혀필요없슴 ㅇ중앙집중방식의전원제어는보안의취약성을쉽게극복 - PoE 시스템으로 PD(POWERED DEVICE) 를구축하면만약의경우에빌딩청소를하거나또는빌딩공사 로 PD 를사용하고있는장소의전원이차단되거나조작되는행위로부터자유.

PoE 기술 2. 케이블 PIN 배열 802.3af Standards A and B PINS on Switch 10/100 DC on Spares (mode B) 10/100 Mixed DC & Data (mode A) 1000 Gigabit DC & Bi-Data Pin 1 Rx + Rx + DC + TxRx A + DC + Pin 2 Rx - Rx - DC + TxRx A - DC + Pin 3 Tx + Tx + DC - TxRx B + DC - Pin 4 DC + unused TxRx C + Pin 5 DC + unused TxRx C - Pin 6 Tx - Tx - DC - TxRx B - DC - Pin 7 DC - unused TxRx D + Pin 8 DC - unused TxRx D - ㅇ MODE A - 두개 ((MDI and MDI-X) 의변환되는구조를가지고있으며, 극성이다른동일한 pairs 를사용 - Pins1-2 (pair #2 in T568B wiring) 에 DC (+), pins 3-6 (pair #3 in T568B) DC (-) 를사용 - 10Base-T and 100Base-TX 에서두개의같은 pairs 를사용하여 data 를전송하며, 네트워크상에서전원과데이터양쪽모두를공급하는경우. ㅇ MODE B - Pins 4-5 (pair #1 in both T568A and T568B) DC, pins 7-8 (pair #4 in both T568A and T568B) 공급. T568A and T568B wiring 규격 Pin 1 2 3 4 5 6 7 8 T568A Pair 3 3 2 1 1 2 4 4 T568B Pair 2 2 3 1 1 3 4 4 wire tip ring tip ring tip ring tip ring

PoE 기술 3. Configuration via Ethernet layer 2 (LLDP) 의구조 LLDP - MED Advanced Power Management TLV Header MED Header Extended power via MDI Type (7 bits) Length (9 bits) TIA OUI (3 octets) Extended power via MDI subtype (1 octet) Power type (2 bits) Power source (2 bits) Power priority (4 bits) Power value (2 octets) 127 7 00-12-BB 4 PSE or PD Normal or Backup conservation Critical, High, Low 0-102,3 W in 0,1 steps ㅇ LLDP : Link Layer Discovery Protocol( 링크계층탐색프로토콜 ) - 보고되는망정보를단순히수집하여활성화된망의현상태를탐색ㅇ MED : Media Endpoint Discovery - 미디어종점검색ㅇ MDI : Medium dependent interface - 이더넷에서사용하는 connection 종류 (straight-through or crossover) 를검색, 즉컨넥터와같은실제접속부ㅇ TLV : Type Length Value - 데이터의타입, 데이터의길이, 데이터의내용ㅇ TIA : Telecommunications Industry Association ㅇ OUI : Organizationally Unique Identifier - IEEE에서 MAC(Media Access Control) 주소할당받아사용하는제조사주소

PoE 기술 4. Stages of powering up a PoE link Stage Action Volts specified [V] 802.3af 802.3at Detection PSE detects if the PD has the correct signature resistance of 15-33 kω 2.7-10.0 Classification PSE detects resistor indicating power range ( 아래표참조 ) 14.5-20.5 Mark 1 Signals PSE is 802.3at capable. PD presents a 0.25-4 ma load. - 7-10 Class 2 PSE output classification voltage again to indicate 802.3at capability - 14.5-20.5 Mark 2 Signals PSE is 802.3at capable. PD presents a 0.25-4 ma load. - 7-10 Startup Startup voltage > 42 > 37.2 Normal operation Supply power to device 44-57 50-57 IEEE 802.3at capable devices are also referred to as "type 2". An 802.3at PSE may also use layer2 communication to signal 802.3at capability. 4-1. IEEE 802.3af 에서는전력소모에따른전원공급규격 Class Usage Classification current [ma] Power range [Watt] Class description 0 Default 0-4 0.44-12.94 Classification unimplemented 1 Optional 9-12 0.44-3.84 Very Low power 2 Optional 17-20 3.84-6.49 Low power 3 Optional 26-30 6.49-12.95 Mid power 4 Reserved 36-44 12.95-25.50 High power

측정의필요성 PD PD 가정상동작이정상동작이되지되지않을않을때 1. PSE 라인에 PoE 장비를연결하여정상적으로전력이공급되는지확인 2. 전력측정이안된다면, PSE 의스위치설정상태를측정하여 PoE 세팅확인 3. 전력이공급되면공급되는전압, 전류확인 ( 각 PD 에적합한전력이공급되는지확인 ) 4. 케이블확인 : 케이블의임피던스가높으면 PoE 성능을떨어뜨릴수있으므로길이및배선확인 5. 몇몇 PSE 제조사는 802.3af 규격을응용하여독자적인 PoE 기술을사용규격에무관하게 PD 장비와호환성확인 PoE PoE 공사공사및검수의검수의필요성필요성 1. 각종오류를사전에예방하여작업시간을단축 - 작업이완료된후 wiring test 를이용하여신속, 정확하게 wiring 상태확인 - 각 PD 에공급될전력을사전에확인하여적절한전력이공급되는지확인 2. 공사완료후검수의편리성 - 공사시 DATA 와검수시 DATA 의일치확인 - 시방서와동일하게공사가진행되었는지확인

가장효율적인 PoE 측정기는?

언제측정을해야하는가? ㅇ포트가살아있는가? 또한정상인가요? ㅇ이장비에설정된속도 / 듀플렉스는무엇인가요? ㅇ PING 테스트를할수있나요? ㅇ케이블이연결된스위치포트의모델 / 주소 / 슬롯및포트번호는? ㅇ PC의 LAN CARD는이상이없나요? ㅇ PoE 전압은정상인가요? ㅇ이케이블은문제가없나요? ㅇ이케이블이허브의어디에연결되었는지또는여러가닥중어떤케이블인지알수있나요? 왜 LanScaperPRO 인가? ㅇ아래와같은설비시공자와 IT기술자를위한 - PCs, VoIP Phones, Switches, Routers, Wireless Access Points, IP camera ㅇ아래와같은내용을알고싶을때 - 포트나분기 (Drops) 가올바르게접속되있는지 - POE 상에적당한전력인지 - IP 어드레스가제대로할당되었는지 - ( 인터넷장비들을포함한 ) 장비에통신이가능한 - LAN 케이블및패치코드확인이필요할때

The LanScaperPRO 구성 RJ45 jack 100 MB indicator LINK indicator LOW BATT indicator 그래픽액정 사용하기쉬운키패드 배터리교체 POWER key

측정기능 1. Network Test modes ㅇ Port Discovery - RJ45 jack을이용한 Active되어있는많은이더넷포트중에서원한는 PORT를찾을수있슴ㅇ Ping Test - 한번에 3개의어드레스를사용하여시뮬레이션가능 : target, router, DNS server - 셋업되지않은 DNS sever, router를 DHCP protocol 이용한 ping 테스트지원ㅇ Hub Flash - link indicator를이용하여 hub or switch port를찾을수있슴. ㅇ Cisco Discovery - 링크된Cisco bridge or router port를찾아보여줌cisco Discovery Protocol (CDP) 메시지를사용하여네트웍에존재하는각각의장비를보여줌ㅇ PoE Test - IEEE 802.3af 밒 Cisco In Line Power(ILP) 사용하는장비에서 PoE를감지하고확인 - 파워를적절하게공급할수있게핀이연결되어있는지검사를할수있으며및종단에있는장비의지나친파워의 loss를방지할수있다

측정기능 2. Cable Test modes ㅇ Cable test - 케이블의한쪽끝에서 shorts, opens, and split pairs( 선꼬임 ) 확인가능 - 전체케이블의오배선, 꼬임등을테스트하여찾아낸다ㅇ Remote Mapping - Test 할케이블에 Remote Identifier (Wiremapper) 를대면캐이블번호를알수있다. ㅇ Cable Length : 각 pair 의길이를케이블의정전용량을이용하여측정한다ㅇ Tone Generator : 선택한핀에 tone 신호를보내면서 tone 추적장치와함께사용한다 3. Properties functions ㅇ Last DHCP Values - 가장최근사용한측정기와 DHCP 서버간 DHPC 값이표시 - MyIP : LanScaperPRO의 IP address - Host : DHCP server에연결된 LAN IP address - Rtr : router에연결된lan IP address - DNS Srvr : LAN을이용하여조절가능한 DNS server의 IP address - Netmask: 사용되고있는 Netmask ㅇ MAC Address - 제조시세팅된 Media Access Control (MAC) number unit 번호표시 - 이더넷장비와사용시반드시 MAC Address를사용한다ㅇ Product Version : 펌웨어버전표시ㅇ Charge Remaining : 남아있는전원의양을표시

PoE 테스트 ㅇ End-span devices 테스트 LanScaperPRO 에포트연결 If powered by an end span device, PoE will be typically be detected on pairs 1-2 and 3-6 ㅇ Mid-span 테스트 The test set will report Cisco ILP or IEEE end span power LanScaperPRO 에포트연결 If powered by a mid span device, PoE will typically be detected on pairs 4-5 and 7-8 테스트셋은 Cisco ILP 와 IEEE 에 Mid-span 을보고합니다. If there is problem in the cable/installation, and the supplied voltage drops below 36V when a load is applied, the tester will report Resistance Problem When testing PoE, if the supplied power is below the requirement of the device to be plugged in, then a mid span PoE device can be installed

PoE 실제측정예시 ㅇ Cisco end span Device (Cisco Switch) - Power found in pair 1,2 and 3,6 - Power supplied = 45.25V x 0.1555A = 6.6W - IEEE end span device (Extreme Switch) - Power found in pair 1,2 and 3,6 - Power supplied = 43.25V x 0.161A = 7W

LanScaperPRO packages NT800 ㅇ LanScaperPRO Cabling and Network Tester with cable test remote ㅇ Includes: - 30.48 cm (1 ft) RJ45 to alligator clips cable (TP40) - Two 30.48 cm (1 ft) cables with RJ45 connectors (TP55) - Two 19 cm (7.5 in) RJ12 to RJ12 cables for no-fault connection to RJ11 or RJ45 jacks (TP20) - Nylon case. ㅇ Requires four AA batteries (not included) NT850 ㅇ LanScaperPRO Cabling and Network Tester Kit with 8 cable test remotes and probe ㅇ Includes: - 30.48 cm (1 ft) RJ45 to alligator clips cable (TP40) - Two 30.48 cm (1 ft) cables with RJ45 connectors (TP55) - Two 19 cm (7.5 in) RJ12 to RJ12 cables for no-fault connection to RJ11 or RJ45 jacks (TP20) Tone Tracer Probe (TT100) -Nylon case. ㅇ Requires four AA batteries (not included)