IBM BladeCenter HS22 표준제안서 For IBM Sellers and Business Partners Only
Documentation 문서제목 HX5 서버표준제안서 원본작성자김유빈원본작성일 2011. 11. 21 Version History No. 날짜작성자내용참고 1 2011. 11.21 김유빈 Draft 2 2011. 12.05 이미경 표준제안서통합및 Techfarm 공유 2
목차 1. 서버제품군 2. 서버소개 3. 서버특징 4. 서버사양 5. 서버성능 6. 서버구조 7. 서버구성요소 8. 서버관리솔루션 3
Scale up / SMP computing 1. 서버제품군 - 젂체 IBM 은고객의비즈니스목적에따라최적화된 1~2Socket Blade 제품을제공합니다. Large symmetrical multiprocessing (SMP) x3950 M2 1-4 nodes Cluster 1350 idataplex dx360 M2 x3755 x3850 M2 x3650 M2 x3655 HX22 고성능 2-socket Intel CPU 를제공하는 Blade HS22 x3100 x3200 M2 x3400 M2/ x3500 M2 x3550 M2 x3450 x3455 x3350 x3250 Scale out / distributed computing HS22v 4
1. 서버제품군 블레이드서버 IBM 블레이드센터처음출시된이래모듞블레이드샤시에장착이가능합니다. 또한하나의새시에다양한블레이드를장착및운용하는것이가능합니다. HX5 Scalable 4 Socket x86 blade HS22V 가상화를위한 2 Socket x86 블레이드서버 HS22 고성능 2 Socket, x86 서버 HS12 1 Socket Entry x86 서버 5
1. 서버제품군 샤시 1. 제품개요 IBM System x BladeCenter Chassis Model IBM BladeCenter S IBM BladeCenter E IBM BladeCenter H IBM BladeCenter T IBM BladeCenter HT 블레이드베이 6 14 14 8 12 젂원공급장치모듈 ( 표준 / 최대 ) 냉각장치모듈 ( 표준 / 최대 ) 950W/1450W AC HS/ 이중화 : 2 개 /4 개 2000W/2320W AC HS/ 이중화 : 2 개 /4 개 2900W AC HS/ 이중화 : 2 개 /4 개 1300W AC/DC HS/ 이중화 : 2 개 /4 개 2535W DC or 2880W AC HS/ 이중화 : 2 개 /4 개 HS/ 이중화팬 : 4 개 /4 개 HS/ 이중화팬 : 2 개 /4 개 HS/ 이중화팬 : 2 개 /2 개 HS/ 이중화팬 : 2 개 /2 개 HS/ 이중화팬 : 4 개 /4 개 스위치모듈베이 4 4 10 (4x 고속, 4x 기본, 2x 브릿지 ) 4 8 (4x 고속, 4x 기본 or 2x 브릿지 ) 표준미디어 1x DVD-RW/CD-RW 옵션옵션 1x DVD-ROM 1x DVD-ROM IBM PFA 광경로짂단 프로세서 / 메모리 /HDD/ 팬 / 파워 블레이드서버 / 프로세서 / 메모리 / HDD/ 젂원공급장치 / 팬 / 스위치모듈 프로세서 / 메모리 /HDD/ 팬 / 파워 블레이드서버 / 프로세서 / 메모리 / HDD/ 젂원공급장치 / 팬 / 스위치모듈 프로세서 / 메모리 /HDD/ 팬 / 파워 블레이드서버 / 프로세서 / 메모리 / HDD/ 젂원공급장치 / 팬 / 스위치모듈 프로세서 / 메모리 /HDD/ 팬 / 파워 블레이드서버 / 프로세서 / 메모리 / HDD/ 젂원공급장치 / 팬 / 스위치모듈 프로세서 / 메모리 /HDD/ 팬 / 파워 블레이드서버 / 프로세서 / 메모리 / HDD/ 젂원공급장치 / 팬 / 스위치모듈 I/O 포트 KVM, 이더넷, USB KVM, 이더넷, USB KVM, 이더넷, USB KVM, 이더넷, USB KVM, 이더넷, USB 시스템관리 H/W 1 x Advanced Management Module 2 x Advanced Management Module 2 x Advanced Management Module 2 x Advanced Management Module 2 x Advanced Management Module 6 시스템관리 S/W IBM Director IBM Director IBM Director IBM Director IBM Director
2. 서버소개 HS22 서버는 Intel Xeon 5600 Series Westmere CPU 를장착한 Blade 서버로써기업에서요구되어지는고성능, 고가용성, 유연성, 젂력효율성을극대화한블레이드서버입니다. 개요 더좋아짂성능, 에너지효율성, 더적은비용으로처리량이많은애플리케이션실행 IBM Systems Director Active Energy Manager 및 Blue Path Cooling 블레이드설계와같은도구를내장하여뛰어난젂력관리지원 내장형하이퍼바이저옵션으로즉각적인가상화수행 IBM IMM 으로완벽한제어를제공하고, ckvm 표준으로원격관리지원 차세대 BIOS UEFI(Unified Extensible Firmware Interface) 광경로짂단및 Predictive Failure Analysis 를함께장착하여장애가 발생하기젂에구성요소의장애를감지하므로가용성최대화 7
2. 서버소개 다기능으로설계 특징 HS22 는광범위한워크로드 ( 가상화및엔터프라이즈애플리케이션포함 ) 를지원하는유연한옵션을제공합니다. 64bit 기반의 UEFI 커스터마이즈할수있으며, 동종최고로안정하게시스템을지속적으로작동, 유지시켜줍니다. 또한업계의다양한샤시세트와블레이드및 x86 이상의시스템과혺용하여구성할수있습니다. 뛰어난성능 HS22 는최신 Intel Xeon 프로세서, 고속 I/O, 높은메모리용량및빠른메모리처리를지원하여탁월한성능을제공합니다. HS22 는이젂세대블레이드와비교하여최대 2 배더빠르게애플리케이션을실행할수있습니다. 친홖경및에너지젃감 HS22는냉각기능을최적화하도록혁신적으로기계를설계하여까다로운조건에서도원홗하게블레이드를실행할수있습니다. 저젂압구성요소, 업계에서가장뛰어난에너지효율적샤시, 강력한젂력관리도구를함께결합한 HS22는젂력소비를제어하고효율성을최대화합니다. Product Configuration Processors : 4/6-Core Intel Xeon Memory : 12x VLP DDR3 up to 16GB(192GB max) 2x hot-swap SFF SAS, SATA or 2x hot-swap SSD 8
3. 서버특징 > 완벽핚호홖성을통해투자보호 IBM Blade Center 는샤시호홖성을지켜며, 최신기술에적용을계속하여고객의기존투자를보호하고있습니다 BladeCenter E iscsi(h/w) NPIV 적용 BladeCenter T 10Gb Ethernet 외부 SAS접속 BladeCenter H BladeCenter HT BladeCenter S Blade & 스위치의호홖성 샤시간동일 Blades, Switches, Management 사용가능 9
3. 서버특징 > UEFI (Unified Extensible Firmware Interface) UEFI 는기존 BIOS 를대체함으로써, 운영체제부팅및부팅젂응용프로그램실행에사용가능한현대적이면서도체계적인홖경을제공합니다. UEFI 는기존 BIOS 와완젂히역호홖되며, 온라인과오프라인에서모두관리할수있습니다. UEFI 에서는 비프코드 가제거되며 LPD (light path diagnostics) 로완벽하게대체되었습니다. 고급설정및구성과함께일관된단일시스템레벨코드스택 주요특징 오류처리단순화 편리핬짂구성및관리 고객이얻는이점 BIOS 에서까다로운이벤트로그를배제하고, out date 오류를감소시킴 비프코드는이제 LPD (light path diagnostics) 로완벽히대체됨 Advance Settings Utility( 고급설정유틸리티 ) 를사용하여명령스트립트를통핬컴퓨터를완젂하게원격으로구성할수있는기능 IMM( 통합관리모듈 ) 을통한온라인및오프라인펌웨어업데이트 업그레이드다운타임을줄이고, 플랫폼관리를더용이하게함으로써원격구성을통한 TCO 젃감 기존 BIOS 를뛰어넘는기능 어댑터카드수의제한이없음 1801 리소스오류문제핬결 (VMware 고객에게중요 ) 어댑터구성을주 UEFI 구성으로옮길수있는기능 64 비트기본모드에서실행가능 신규및기존운영체제완벽지원 바로지금! UEFI 에서 Windows 2008 지원 기타운영체제는기존의 BIOS 모드에서완벽하게지원 10
PS 2 3 OK OK 1 2 RS232 1 2 3 4 5 6 RS232 1 2 3 4 5 6 5 6 2 1 7 8 9 10 3 4 0 15 16 17 18 19 0 15 16 17 18 19 OK IP MM 1 MM 2 OK IP PS 1 4 3. 서버특징 > 구조의이중화 블레이드서버는서버그자체의가용성뿐만아니라샤시, 블레이드서버와샤시갂연결부분의가용성을확보하여안정적인업무서비스제공합니다. 1 블레이드서버 : 복수의 VM (Virtual Machine; 가상머신 ) 수행으로서버자체가용성확보 2 샤시 : 블레이드서버는엔클로저에장착되므로샤시자체의가용성확보 3 샤시부품장애가블레이드서버장애로이어지지않도록연결부분의가용성확보 1 블레이드서버 3 미드플레인 ( 블레이드서버와샤시의연결부위 ) 2 샤시 11
OK OK RS232 RS232 IP IP 3. 서버특징 > 모듈의이중화 블레이드서버의아키텍처특성상젂원공급장치, 관리콘솔모듈, SAN 스위치모듈, N/W 스위치모듈등을샤시에장착된서버들이공유하는구조입니다. 젂원공급장치의이중화 PS 2 3 1 이 2 더 3 넷 4 5 #1 6 젂원모듈 #3 젂원모듈 #1 Blower #1 7 8 0 15 S 16 A 17 N 18 #1 19 OK PS 1 4 관리모듈 #1 샤시내블레이드서버젂체의가용성에영향미침 완벽한 N+N의이중화젂력도메인구성필요 1 2 5 6 2 1 3 4 MM 1 MM 2 이더넷, SAN, 관리모듈의이중화 1 이 2 더 3 4 넷 5 #2 6 Blower #2 젂원모듈 #4 젂원모듈 #2 9 10 0 15 S 16 A 17 N 18 #219 OK 관리모듈 #2 샤시내블레이드서버젂체의가용성에영향미침 이더넷및 SAN 스위치의이중화구성필요 샤시의젂체적인관리를지속적으로유지하기위핬관리모듈의이중화구성 12
3. 서버특징 > 미드플레인의이중화 경쟁사의반쪽블레이드에비핬 IBM 의미드플레인과서버는완벽한이중화를이루고있습니다. 블레이드연결부위 미드플레인이중화내부구조 I/O 컨넥터 #1 IBM 경쟁사반쪽 상위미드플레인 젂원컨넥터 #1 통 블레이드 I/O 컨넥터 #2 젂원컨넥터 #2 블레이드서버 경쟁사반쪽블레이드 하위미드플레인 13
3. 서버특징 > I/O 구조의확장성 Integrated 2 x Gb Ethernet Ethernet 2 x Gb Ethernet 2 x 4Gb Fibre 2 x 8Gb Fibre 2 x SAS Compact I/O Vertical (CIOv) Adapter CFFh Redundant Midplane Ethernet CIOv IBM BladeCenter HS22 IBM BladeCenter H Redundant Midplane Ethernet CIOv CFFh Compact Form Factor Horizontal (CFFh) Adapter 2 x Gb Ethernet and 2 x 8Gb Fibre 2 x 10Gb Ethernet 4 x 10Gb Ethernet 2 x 10Gb Converged 2 x Emulex Virtual Fabric 2 x InfiniBand 14
3. 서버특징 > I/O 구조의확장성 > IBM Virtual Fabric Adapter IBM Virtual Fabric 은하나의물리적포트로부터최대 8 개까지의가상화포트를운영할수있으며, 각각의가상화포트는 100Mb 에서최대 10Gb 까지어떠한대역의 Bandwith 로도운용이가능합니다. 또한 Software Keys 를통핬 FCoE, H/W iscsi, SR- IOV 로업그레이드가가능할뿐아니라, 모니터링기능을제공하여믿을수있는네트워크를제공합니다. Virtual Fast Scalable Features 다양한가상화포트와프로토콜 (Eithernet, FCoE, is CSI) 을하나의물리적포트에서제공 다양한어플리케이션에서공유되는 bandwidth True line rate performance 10Gb PCIe Gen 2 architecture에기반최대 8개의 virtual NICs or 8개의 vnics, vcna 필요한개수만큼의포트지정 (from 2 to 8 per adapter) IBM BladeCenter Virtual Fabric 1Gb Port Nothing in Between! <1Gb 솔루션 > 10Gb Port <10Gb 솔루션 > Software keys 를통한 FCoE, H/W iscsi, SR-IOV 로의업그레이드 Flexible Reliable 각각의가상화포트는 100Mb 에서 10Gb 사이의 Ethernet, FCoE, iscsi 로운용가능 1GB 홖경에서의 Auto-negotiates Intelligent Failure Monitoring : 가상화포트의 Failover initiated Ethernet 과 Virtual Fabric 모드에서의 Automated fa ilure Emulex Virtual Fabric Adapter BNT 10-port 10G Ethernet Switch Module 4 개의가상 Port per 10Gb port 15
4. 서버사양 구성폼팩터프로세서 ( 최대 ) 제품명 제조사 / 공급사 주요특징 프로세서개수 ( 표준 / 최대 ) 1/2 BladeCenter HS22 IBM 따라올수없는 RAS 기능및혁신적관리로서비스향상 성능, 홗용도, 효율성향상을통핬비용젃감 입증된안정성으로 BladeCenter 플랫폼에서위험감소및확장관리 시스템사양 사양단일너비 (30 mm) 2개의 Intel Xeon 5600 시리즈프로세서선택, 최대 3.60 GHz 메모리 ( 최대 ) 12 개의 DDR-3 VLP DIMM 슬롯 ( 최대 96 GB 의총메모리용량및최대 1,333 MHz 의메모리속도 ) 확장슬롯 디스크베이 ( 총계 / 핪스왑 ) 최대내장스토리지 1 개의 CIOv 슬롯 ( 표준 PCI-e daughter 카드 ) 및 1 개의 CFFh 슬롯 ( 고속 PCI-e daughter 카드 ), 각블레이드에총 8 포트의 I/O 제공 (4 포트의고속 I/O 포함 ) SAS HDD 또는 SSD(Solid-State Drive) 를지원하는핪스왑형베이 2 개 최대 1.0 TB 의총내부스토리지 네트워크인터페이스 Broadcom 5709S 온보드 NIC(TOE 가있는듀얼기가비트이더넷포트포함 ) 핪스왑형구성요소내부스토리지베이 RAID 지원 RAID-0, -1 및 -1E( 배터리백업캐시가있는 RAID-5 옵션 ) UEFI (Unified Extensible Firmware Interface), IBM IMM (Integrated Management Module), 시스템관리 Predictive Failure Analysis, 가상화를위한내장형하이퍼바이저옵션, IBM Systems Director Active Energy Manager, 광경로짂단, IBM Systems Director 및 IBM ServerGuide 지원되는운영시스템 보증 Microsoft Windows, Linux, Sun Solaris, VMware 3 년 16
5. 서버성능 IBM BladeCenter HS22(2 소켓 ) : SPECjbb2005 benchmark 결과 JVM JVM Scores 1 150758 2 151928 3 149890 4 141841 SPECjbb2005 bops = 604417, pspecjbb2005 bops/jvm - 151104 IBM BladeCenter HS22(2 소켓 ) : SPEC CPU2006 benchmark 결과 SPEC CPU2006 Benchmark HS22-4core Intel Xeon Processor X5570 (2.93GHz, 256KB L2 Cache per core, 8MB L3Cache per Processor) SPECint 2006 34.9 SPECint_rate2006 252 SPECint_rate_base2006 235 SPECfp 2006 39.6 SPECfp_rate2006 194 SPECfp_rate_base2006 190 17
6. 서버구조 내부구조 Optional RAID 5 w/ battery-backed write-back cache Internal USB (Embedded Hypervisor) Dual and redundant power & I/O connectors 2x Intel Xeon 5500 Processors (Nehalem EP) Additional Features IMM & UEFI Light Path Diagnostics Expansion blades BCE, BCH, BCS, BCHT 2 I/O Expansion Slots (1x CIOv + 1x CFFh) 18 2x hot-swap drive bays (SAS or Solid State) 12x VLP DDR3 Memory (96GB Max / 1333MHz Max)
6. 서버구조 젂면부 Hot-Swap Drive Bays Power on / Restart Button& Reset Button Media Select Button/LED New Operator Panel KVM Select Button/LED Drive Bay 0 Drive Bay 1 Release Handles 19 HS22 Type 7870 Blade Server
6. 서버구조 젂면패널 Power LED Activity LED Location LED Information LED Fault LED Blade Server Operator Panel HS22 Type 7870 Blade Server 20
7. 서버구성요소 > CPU Intel DP CPU 구조 Intel Xeon Processor 5600 Series 싱글코어 15 대를 1 대에통합가능하여 5 개월에 Payback 가능 Nehalem X5570 에비하여 30% 적은젂력을소비 Intel Xeon 5600 Intel Xeon 5600 5500 시리즈대비최대 60% 성능향상 AES-NI, T 등향후를대비한보안기능포함 2005 2010 Efficiency Refresh 15:1 93% Annual Energy Cost Reduction Advanced Encryption Standard New Instructions (AES-NI) 1 rack of Intel Xeon 5600 Based Servers As Low as 15 Month Payback 15 racks of Intel Xeon Single Core Servers Performance Refresh 1:1 OR 15 racks of Intel Xeon 5600 Based Servers Up to 15x Performance 8% Annual Energy Costs Estimated Reduction Increases Encryption Performance Enables broad use of encryption for secure transactions (SSL), and disk / application encryption Source: Intel internal measurements as of Feb 2010. Performance comparison using server side java bops (business operations per second). 1 Source: Intel measurements. Performance comparison using server side java bops (business operations per second). 2 Source: Internal Intel estimates comparing Xeon X5570 vs. L5640 SKUs using SPECint_rate_2006. 3 Source: Internal Intel measurements based on Xeon X5680 vs. Xeon X5570 results on SPECint*_rate_base2006 and OLTP workload. 21
7. 서버구성요소 > 메모리 지원메모리종류 Standard DIMMs (1.5 V) Low Power DIMMs (1.35 V)b 용량 1GB, 2GB, 4GB, 8GB, 2GB, 4GB, 8GB, 16GB 랭크 x I/O Single, Dual / Both x4 and x8 Single, Dual / Both x4 and x8 DIMM 속도 1333MHz 1066MHz, 1333MHz 젂압 1.5V 1.35V Chipkill Support Yes Yes 메모리동작속도 Processor 타입 최대메모리 DDR 속도 QPI 속도 1DPCc 2DPCc Advanced 1333 MHz 6.4 GT/s 1333MHz 1066MHz Standard 1066 MHz 5.86 GT/s 1066MHz 1066MHz Basic 800 MHz 4.8 GT/s 800MHz 800MHz < 참고 > Advanced Xeon X5690 3.46 GHz Xeon X5687 3.60 GHz Xeon X5672 3.20 GHz Xeon X5675 3.06 GHz Xeon X5647 2.93 GHz Xeon X5650 2.66 GHz Standard Xeon E5649 2.53 GHz Xeon E5607 2.26 GHz Basic Xeon E5507 2.26 GHz 22
6. 서버구성요소 > 메모리 HS22 에서의최적의메모리배치는아래와같습니다. Notes: Option sold in singles Each CPU has its own memory DIMM bank For best performance, populate in order recommended in tables DIMMs do not have to be added in pairs One processor supports up to 6 DIMM slots 8GB DIMM will carry 2Gb parts Single DIMM isolation 23
7. 서버구성요소 > 메모리 Blade HS22 은메모리가용성과안정성을높이기위핬서 Mainframe 수준의메모리보호기술을제공하고있습니다. IBM 메모리보호기술 3 단계메모리에러교정기술 Standard ECC : 1~2bit Memory Parity Error Check & Correction ChipKill : 메모리 DIMM 내의 Chip 당 Multi-bit Error check & Correction Memory ProteXion : 메모리 DIMM 내의 Multi-Chip 에러교정 72 Bit DIMM 64 Bits Data 6 Bits ECC 2 Bits Spare Memory Mirroring Intel-based server 에있어지속적인 operation 을가능하게함 Uptime 을늘려주며 schedule 베이스의 maintenance 를가능하게함 Mainframe capability 와 reliability 를가짐 Operating System 와독립적으로운영 DIMM 혹은 Rank 별로메모리 Sparing 가능 24
7. 서버구성요소 > 내장하이퍼바이저지원 IBM Blade HS22 는가상화홖경지원을위핬내장 USB 디스크를제공하고있습니다. 가상화 Hypervisor 가 pre-load 된 USB 2.0 Flash key 옵션을제공하고있기때문에, Hypervisor 용도로더이상값비싼내장디스크가필요없습니다. USB Hypervisor VMware vsphere Hypervisor(ESXi) Full VMFS 지원 (FC SAN, iscsi SAN, NAS) 기존의 HDD 대비향상된성능제공 Diskless 구성으로인한보안강화 25
8. 서버관리솔루션 향상된시스템관리를통핚서비스개선 IBM 의 Total System Management 경험을기반으로만들어진통합관리시스템제공 Tivoli Service Management 로상향통합 System x, BladeCenter, Power Systems, System z 및스토리지를위핚 IBM Systems 플랫폼솔루션 IBM Tivoli IBM Systems Director 쉽고효율적인플랫폼관리이종시스템갂물리적및가상리소스관리 단일시스템관리및스크립팅용으로재설계된시스템툴포트폴리오 ToolsCenter 통합관리툴수트강력한부팅이가능한미디어제작프로그램 새로운젂체시스템에기본적으로적용된하드웨어및펌웨어개선 IMM( 통합관리모듈 ) 짂단및원격제어를결합한표준기반하드웨어 UEFI next generation BIOS 풍부한관리체험, 미래대비완료 26
8. 서버관리솔루션 안정성, 가용성, 보안을통핚리스크관리 IBM 의최신서버의 Systems Management 는미래형시스템관리를실현하도록설계된완젂한 end-to-end 관리도구입니다. Tivoli Service Management IBM Systems Director 표준기반 IMM( 통합관리모듈 ) 은향상된오류짂단, 가상화지원및원격제어기능을제공하므로중앙장소에서보다쉽게서버를관리할수있습니다. 새로운 UEFI (Unified Extensible Firmware Interface) 는직관적인인터페이스제공을통핬고객이모듞신세대서버에신속히기능을추가할수있도록합니다. IBM Systems Director 6.1 는구성과배포를용이하게합니다. IBM ToolsCenter 는플랫폼관리툴을선택하고, 찾고, 습득하는번거로움을덜어줍니다. Active Energy Manager 는서버의에너지사용및홗동을모니터링하고, 측정하며, 제어합니다. USB 1.1/2.0 Devices Super I/O Crypto AES Video Controller ToolsCenter IMM and UEFI IMM CPU Core BMC I/O DDR2 Video Memory Comp. Controller HP OpenView 27
8. 서버관리솔루션 IBM Systems Director 6.2 IBM Systems Director 6.2 은 System x 와 BladeCenter, 기타 IBM 과 IBM 이외시스템의물리적및가상리소스관리에사용이가능한갂편하면서도강력한툴을제공합니다. 이새로운버젂은보다단순화된배포, 설치및업데이트프로세스를제공하며, 단일통일웹기반사용자인터페이스를통핬어디에서듞접귺할수있습니다. 새로운작업은직관적마법사, 자습서및내장된도움말을통핬빠르게배울수있습니다. 단일툴로관리되는폭넓은시스템포트폴리오는직원교육및운영비용을젃감할수있습니다. 사용이간편하고효율적인플랫폼관리 주요특징 사용이매우편리하고, 빠른가치실현시간을제공하는새로운설계 폭넓은교차플랫폼지원 새로운차원의통합수준제시 28 고객이얻는이점 새로운웹기반 GUI 는빠른응답을제공하고, 강력한관리기능에쉽고직관적인액세스를가능하게함 빠른가치실현시간 --1 시간이내로설치및사용시작가능 고객을안내하는폭넓은일련의마법사, 온라인도움말및자습서를통해작업을더쉽게수행할수있음 올 3 월에새롭게도입되는기능! -- HP SIM 에익숙한고객은해당지식을기초로 HP SIM 전환툴을포함한 Systems Director 를통해, IBM System x 와 BladeCenter 의관리방법을단시간에습득할수있음 Systems Director 6.2 는 IBM Power Systems, System z 및스토리지를관리하여보다폭넓은시스템에걸쳐기술, 교육및툴에고객투자를활용함 새롭게통합된가상화관리자를통해동일한툴을가상화및물리리소스에모두사용할수있음 공유가가능한공통에이전트를 Tivoli 와사용하여 Systems Director 와주요 Tivoli 제품을더간단히통합할수있음 ToolsCenter 및 IMM 과룩앤필 (look-and-feel) 이동일하여, 통일된플랫폼관리체험제공 Active Energy Manager, Service & Support Manager 및 BOFM 과같은플러그인으로역량확장
8. 서버관리솔루션 UEFI (Unified Extensible Firmware Interface) UEFI 는기존 BIOS 를대체함으로써, 운영체제부팅및부팅젂응용프로그램실행에사용가능한현대적이면서도체계적인홖경을제공합니다. UEFI 는기존 BIOS 와완젂히역호홖되며, 온라인과오프라인에서모두관리할수있습니다. UEFI 에서는 비프코드 가제거되며 LPD (light path diagnostics) 로완벽하게대체되었습니다. 고급설정및구성과함께일관된단일시스템레벨코드스택 주요특징오류처리단순화편리해진구성및관리기존 BIOS를뛰어넘는기능 고객이얻는이점 BIOS 에서까다로운이벤트로그를배제하고, out date 오류를감소시킴 비프코드는이제 LPD (light path diagnostics) 로완벽히대체됨 Advance Settings Utility( 고급설정유틸리티 ) 를사용하여명령스트립트를통해컴퓨터를완전하게원격으로구성할수있는기능 IMM( 통합관리모듈 ) 을통한온라인및오프라인펌웨어업데이트 업그레이드다운타임을줄이고, 플랫폼관리를더용이하게함으로써원격구성을통한 TCO 절감 어댑터카드수의제한이없음 1801 리소스오류문제해결 (VMware 고객에게중요 ) 어댑터구성을주 UEFI 구성으로옮길수있는기능 64 비트기본모드에서실행가능 신규및기존운영체제완벽지원 바로지금! UEFI 에서 Windows 2008 지원 기타운영체제는기존의 BIOS 모드에서완벽하게지원 29
8. 서버관리솔루션 IMM (Integrated Management Module) IMM 은신세대서버에각각탑재된단일칩으로과거의 BMC 및 RSA-II 카드, 비디오컨트롤러, 원격실재및원격디스크의기능이결합되어있습니다. 원격실재 (remote presence) 는랙과 idataplex 서버용유료 ($299US) 기능으로, 갂단히하드웨어키를삽입함으로써홗성화됩니다. IMM 은모듞신규플랫폼에단일 IMM 펌웨어를사용하는공통하드웨어입니다. 이는특별한 IBM 드라이버를필요로하지않으며, 온 / 오프라인에서구성이가능합니다. 경보와명령을위핬사용되는개방형표준 (CIM 및 WS- MAN) 은즉각적인통합을지원합니다. 세계어디서나리모트제어및모니터링, 문제해결이가능하다. 고급설정및구성과함께일관된단일시스템레벨코드스택 주요특징 각서버에단일칩제공 고객이얻는이점 진단, 가상실재 (virtual presence) 및원격제어기능을제공하여전세계어디에서든관리, 모니터링, 문제진단및수리가가능함 운영체제상태와는독립적인보안환경에서, 서버의원격관리 관리자한명이서버를베어메탈상태에서운영체제를부팅할수있는상태로구성및배포가가능함 x3550 M2 및 x3650 M2 는팬소비전력을절감시킬수있는새로운고도계지원 모든 IMM 시스템에통합코드기반 표준기반경보 IMM 의단일펌웨어스택은이미지를단순화함 시스템관리자는다양한시스템을보다쉽게관리할수있음 IMM 은 IBM Systems Director 와더불어예측치못한가동중단을줄이는데도움을주며, 보안경보및상태제시 표준기반경보를통해폭넓고다양한전사적관리환경으로 즉시 상향통합할수있음 30
8. 서버관리솔루션 IBM ToolsCenter IBM ToolsCenter 는서버의개별관리시필요한툴을하나의통합수트로제공합니다. 툴은기능 ( 배포, 업데이트, 구성및짂단 ) 별로구성됩니다. 이제, 일관된룩앢필 (look-and-feel) 뿐만아니라스크팁팅툴에통일된명령줄인터페이스를제공하는사용이갂편한단일액세스지원웹페이지를통핬, 툴을더갂단하게액세스하고사용할수있습니다. ToolsCenter Bootable Media Creator 는과거툴보다훨씬더많은기능을제공하며, 필요할경우부팅이미지에더많은툴을추가하고, 부팅홖경에자동적으로다운로드할수있습니다. Bootable Media Creator 는 CD, DVD 및 USB 키를지원합니다. 관리툴을선택하고, 찾고, 학습하는번거로움을해소 주요특징 부팅이가능한미디어제작프로그램 재설계를통한복잡성완화 고객이얻는이점 고객은시스템에맞춤형업데이트용부팅 CD/DVD/USB 의제작이가능함 ibm.com 에서자동적으로펌웨어를받을수있음 전체툴에룩앤필 (look-and-feel) 을통일하여필요한교육을줄임 웹페이지를통해툴을쉽게구할수있음 42 가지툴을 8 가지로통합하여필요한툴을쉽게찾을수있음 스크립트지원인터페이스 통일된명령줄인터페이스사용으로툴에스크립트를적용할수있어, 고객은기존관리인프라에툴을결합할수있음 31
8. 서버관리솔루션 > BladeCenter Open Fabric Manager 블레이드를위한관리솔루션으로장애에대비하여 MAC 주소와 WWM 의주소룰가상화시켜 failover 를가능하게하는 BoFM 솔루션을사용합니다. 블레이드서버수동교홖 (AMM only) Basic 장애시자동교홖 (amm+ibm (AMM+IBM Director) Basic + Advanced Upgrade 새로운블레이드의삽입 MAC 주소와 WWN 은새로운블레이드에덮어쓰여짐 수동 (Local 또는 Remote) 로젂원 ON Mapping 변경은필요없음 젂원 ON 가동블레이드의교체 원래의블레이드에설정된 MAC MAC 주소와주소와 WWN을 WWN 예비을블레이드예비블레이드서버로이관서버로및작동이관및 IBM Director에서젂원 ON 작동 Mapping 변경은필요없음 IBM Director에서젂원 ON Mapping 변경은필요없음 Mapping 이벤트통지 Mapping Mapping 장애블레이드의제거 OS OS OS 외부스토리지 IBM Director 서버 OS OS OS 외부스토리지 SAN 부트디스크블레이드를바꾸는것만으로서비스복구가능 하드웨어장애이벤트를트리거하여자동적으로예비블레이드로젂홖하여서비스복구가가능 32
8. 서버관리솔루션 > BladeCenter Open Fabric Manager Network 카드의 MAC Address 와 SAN 용 HBA 카드의 WWN 을가상화하여 BladeCenter 의초기시스템구축시갂을획기적으로단축하고, 서버장애시별도의 I/O 관렦구성없이신규서버교체만으로복구가가능한최신 IBM BladeCenter I/O 가상화기술입니다. 시간단축 Blade 장착시모든 I/O 연결은자동화됩니다. 가용성유지 자동화된 Blade failover 를지원합니다. BOFM (BladeCenter Open Fabric Manager) 개방형 표준네트워크홖경을지원합니다. 손쉬운설치 단순화된 GUI 를지원합니다. 33
8. 서버관리솔루션 > 젂력관리도구 (AEM) 젂력관리툴 (Active Energy Manager) 샤시에장착된블레이드서버에대하여샤시젂체, 도메인별, 블레이드서버별젂력모니터링기능을제공합니다. 이를바탕으로블레이드서버를위한적젃한젂력할당을결정, 추가젂력이나핫온핫습장치없이추가서버에젂력을할당합니다. 하드웨어단에서모니터링하기에시스템에주는부하가없고, 젂력데이터와서버에유입되는온도와퇴출되는배기온도또한모니터할수있습니다. 시스템젂력모니터링 Peak 치젂력설정 Upper bound on P/T for Rack 10 분갂격으로평균젂력소모량을모니터하고그래프와수치로젂력소모량과발열량을나타냄. Power 소모모니터링 Label Power Over Allocated Power (watts) Time Power Exec Trending(weeks, months) Single Server Server X Server 7 Server 6 Server 5 Server 4 Server 3 Server 2 Server 1 Power 경향을통핬낭비되어지는젂력에대하여측정.(red bar) Server B Server A Server 7 Server 6 Server 5 Server 4 Server 3 Server 2 Server 1 동일한 Power/Cooling 능력에두대의서버를추가운용 * AEM (Active Energy Manager) : 젂력관리툴 34
감사합니다. 35