www.koryocable.co.kr HEAD OFFICE & FACTORY (Ihyeondong)71 Gukchaebosangro, Seogu, Daegu, Korea TEL.+82535701~5 FAX.+825355253 Email.sales@koryocable.co.kr Branch Office (Siheungdong)85 Daewangpangyoro, Sujeonggu, Seongnam, Gyeonggido, Korea TEL. +817821~2 FAX.+8178 Email.sales@koryocable.co.kr 신규품목 신규품목 TFRCV/AL 07 KS IEC 01 1 Koryo Cable 1 2
Overview Message from the CEO Tradition of Trust Koryo Cable leads the industry for customer satisfaction Since the foundation in 19, Koryo Cable Co., Ltd. has been steadily growing based on customersatisfaction business philosophy. Based on our years of successful history with our customers, Koryo Cable will try to make a new leap forward in the industry. We believe in the best quality comes from our strict manufacturing ethics that stick to the principles, and the products with principle can only be a cornerstone to be a credible company with manufacturing ethics. As we have been for the last years, we promise to make our best efforts to deliver the best quality and price products to our customers. Moreover, to become a global corporation, Koryo Cable will increase investment in research & development for the better and new products which meet any of customers global needs. We do these efforts only for your satisfactions, and we will keep continuing in the future. Now, Koryo Cable has named its new cable brand as. The name reflects our wish to Kornect(connect) our vision A company with happy people who value our promise to our customers. Again, We greatly appreciate your kind supports and interest in Koryo Cable. We hope to better serve you in the near future. Chief Executive of Koryo Cable Co., Ltd. Jung, YongHo Koryo Cable 5
Overview Brief History 190 19.. Established Koryo Electric Company 197. 7. Moved to the new factory in Bukgu, Daegu and renamed Koryo Industry 197.. Obtained a license for insulated wire made of synthetic resin (the Commerce Industry Ministry) 198. 11. Became a member of Korea Electric Wire Industry Cooperative 19 197. 5. Obtained KS (Korean Industrial s) marks for annealed copper wire & harddrawn copper wire, and annealed copper stranded wire & harddrawn copper stranded wire (the Industrial Advancement Administration) Obtained KS marks for outdoor PVC insulated wire & PVC insulated drop service wire 1975.. Changed name to Koryo Cable Co., Ltd 1977. 11. Moved to Seodaegu Industrial Complex (Current Location) 1980 1983.. Passed CCPAPSS cable products (Korea Telecom) 1985. 11. JaeChul Jung took office as president 1988. 5. Designated as a Promising Small and Medium Enterprise by the Small & Medium Business Corporation 1990 1991. 11. Adopted medium voltage aluminum stranded conductors with steel reinforced (,9kV ACSROC) 1992. 7. Passed.kV and.9kv ACSR/AWOC development tests 199. 3. Passed the flame retardant control cable and flame retardant sheathed control cable with copper tape shield cable development tests 1998. 9. Acquired certificate of nontoxic flame retardant polyolefin cable(nfreo, NFRCO) 1998. 11. Won the ISO 9001 certification quality system (KETI) ~05 01. 7. Acquired KS marks for UTP, VCT, KIV and vinyl cord 02. 7. Acquired electrical appliances safety certificate for tray flameretardant cables 0. 2. Acquired KS mark for 00V CV 05. 5. Completed 2nd CCV Line *CCV(Catenary Continuous Vulcanizing) 05.. Started to produce.9kvy CNCVW 0~09 0. 2. Passed.9kVy FR CNCOW development test 0.. Passed.9kVy ACSR/AWTR/OC development test 07. 7. Acquired KS mark for UTP Cat 5E 07. 9. Acquired electrical appliances safety certificate for CVF 07. 11. Approved Certificate of Information and Communication Equipment 08. Acquired electrical appliances safety certificate for 0./1kV HFCO 08. 11 Passed.9kVy TR CNCEW development test 09. 9. Acquired Japan PSE mark for 00V CVT 09. 11. YongHo Jung took office as president ~. 3. Acquired electrical appliances safety certificate for /7V HFIX. 9. Started exporting 00V CVT to Japan.. Passed ACSRAW/OC SQ development test. 11. Passed.9kVy TR CNCEW development test 11. 1. Passed.9kVy TR CNCEW/AL development 11. 3. Acquired electrical appliances safety certificate for 0./1kV CVW/AL. 2. Received an award from Minister of Knowledge Economy for over billon in electric industrial export.. Acquired KS mark for /7V HFIX. 9. Received an award at Small Business Ceremony in Daegu Acquired KS mark for /kv HFCO 13 13. 1. Passed.9kV FR CNCOW/AL development test Passed.9kV ASCW development test 13. 2. Changed CI to 1 1. 2. Acquired KS mark for 0./1kV HFCO 1. 5. th Anniversary Ceremony Koryo Cable 7
Overview Supply Confirmation Domestic Supply We will do our utmost to satisfy customers with our solid credit and traditional business spirit of half century since we had established. Major Export Performance Country Customer JAPAN GUAM(USA) VIETNAM HITACHI ZOSEN CORPORATION SENSHU ELECTRIC CO LTD J AND B MODERN TECH DUY TAN ELECTRICAL FORMOSA VIETNAM 0./1kV CU/XLPE/PVC cable(triplex) 0./1kV CU/XLPE/PVC cable(triplex) 0./1kV CU/PVC cable kv AL/XLPE/CTS/PVC cable 3.5kV CU/XLPE/CTS / HDPE 0./1kV CU/PVC cable 0./1kV CU/XLPE/PVC cable PHILIPPINES ZENITH INTERNATIONAL CENTRADE INTEGRATED SALES, CORP. 0./1kV CU/PVC cable 0./1kV CU/XLPE/PVC cable INDONESIA AUSTRALIA MYANMAR MONGOLIA PT. THANIA INDO JAYA BRITECH BAMBACH CABLE TRADING CO., LTD LWIN & SWAN TRADING CO., LTD MONCABLE SYSTEM LLC TIE WIRE(made of aluminum).7kv AL/XLPE/CWS/PVC cable 0./1kV CU/XLPE/PVC cable 0./1kV CU/ XLPE/PVC cable 0./1kV CU/XLPE/PVC cable /7V CU/PVC cable 0./1kV CU/XLPE/PVC cable /7V CU/PVC cable 8 Koryo Cable 9
Overview Contents 1p Annealed Bare Copper Stranded Wire for Electrical Purposes (WOA, WOAS) p HardDrawn Bare Copper Stranded (WOH, WOHS) 17p Aluminium Stranded s Steel Reinforced (ACSR) 18p ConcentricLayStranded Aluminium s Aluminiumclad Steel Reinforced (ACSR/AW) 19p ACSR/AW Outdoor Tracking Retardant Crosslinked Polyethylene Insulated Wire for.9kv (ACSR/AWTR/OC) 19p ACSROutdoor Crosslinked Polyethylene Insulated Wire (ACSROC) p Aluminium Stranded s Aluminiumclad Steel Reinforced Outdoor Crosslinked Polyethylene Insulated Wire (ACSR/AWOC) p /7V Singlecore Nonsheathed Cable with Rigid for General Purposes (IV) (07 KS IEC 01) p /7V HalogenFree Flame Retardant PolyOlefin Insulated Wire (HFIX) 2p /0V Singlecore Nonsheathed Cable with Solid for Internal Wiring (90 C) (HIV) (07 KS IEC 07) p FRPVC Insulated Grounding Wire(TFRGV) 2p 00V Outdoor Weather Proof PVC Insulated Wire (OW) p High Drop Wire for Pole Transformer (SOLP.D.C) 28p PVC Insulated Drop Service Wire(DV) 29p Light Polyvinyl Chloride ed Cord 29p Ordinary Polyvinyl Chloride ed Cord p.9kvy WaterProof Copper XLPE Insulated, Concentric Neutral with Water Swellable Tapes, and PVC (HalogenFree PolyOlefin Flame Retardant) ed Power Cable (.9kVy CNCVW, FR CNCOW) 5p.9kVy WaterProof Aluminium XLPE Insulated, Concentric Neutral with Water Swellable Tapes, and HalogenFree PolyOlefin Flame Retardant ed Power Aluminium Cable (.9kVy FR CNCOW/AL) p.9kvy WaterProof Copper TRXLPE Insulated, Concentric Neutral with Water Blocking Tapes, and Polyethylene Flame Retardant ed Power Cable (.9kVy TR CNCEW) 7p.9kVy WaterProof Aluminium TRXLPE Insulated, Concentric Neutral with Water Swellable Tapes, and Polyethylene Flame Retardant ed Power Aluminium Cable (.9kVy TR CNCEW/AL) p 0./1kV PVC Insulated and Tray FlameRetardant PVC ed Control Cable (TFRCVV) 52p 0./1kV PVC Insulated and Tray FlameRetardant PVC ed Control Cable with Copper Tape Shield (TFRCVVS) 55p 5CHFBT, 7CHFBT, CHFBT 5p Unshielded Twisted Pair Category 5 (Pr/Pr) 57p Unshielded Twisted Pair Enhanced Category 5E (Pr) 59p 0./1kV XLPE Insulated with FireProof Layer and Tray FlameRetardant PVC ed FireRetardant Power Cable (TFR8) 1p 0./1kV XLPE Insulated and Tray FlameRetardant PVC ed HeatRetardant Control Cable (TFR3) p p 0./1kV XLPE Insulated and Tray FlameRetardant PVC ed Cable (TFRCV) 3p 0./1kV XLPE Insulated and Tray FlameRetardant PVC ed Aluminium Power Cable (TFRCV/AL) 3p 0./1kV XLPE Insulated HalogenFree Flame Retardant PolyOlefin ed Power Cable (HFCO) 38p 0./1kV XLPE Insulated PVC ed Flat Cable (CVF) 39p 0./1kV XLPE Insulated PVC ed WaterProof Aluminium Power Cable(CVW/AL) 0p 0./1kV PVC Insulated PVC ed Cable (VV) 2p /kv XLPE Insulated and Tray FlameRetardant PVC ed Cable(/kV TFRCV) 3p /kv XLPE Insulated HalogenFree Flame Retardant PolyOlefin ed Power Cable (/kv HFCO) Koryo Cable 11
We will do our utmost to satisfy customers with our solid credit and traditional business spirit of half century since we had established. 나동선 Annealed Bare Copper Stranded Wire for Electrical Purposes (WOA, WOAS) HardDrawn Bare Copper Stranded (WOH, WOHS) 13
나동선 Annealed Bare Copper Stranded Wire for Electrical Purposes (WOA, WOAS) HardDrawn Bare Copper Stranded (WOH, WOHS) Application Used for electrical conductor Construction Annealed Copper Wire KS C 33 / KS C IEC 31 / KS C 31 Application Used for aerial transmission lines, distribution lines and other electrical purposes Construction HardDrawn Stranded Copper Wire (General Purpose and Aerial Transmission Purpose) KS C 3 Annealed Copper Wire HardDrawn Stranded Copper Wire Number & of Wire No. Calculated Sectional Area 799 1.375 79 3.519 8 7.917 8 29 29.09 37.1 8.3 59. 78. 1.5 3.7 19. 3.5 3.8 02.9 90. 0 73 838.8 1,02 Overall 3..8.0 7.8 9.0.0 1 1 18.2 2. 2.1 28.8 3.2 37.7 1. 7.913.37 17.80 31. 9. 79.7 197.9 2 33..1 537.0 7.3 907. 1,9 1,390 1,77 2,298 2,937 3,5,8 5,,55 7,51 9,3 Max Resistance at Length 0.5 5 1 1 1 00 0 Number & of Wire No. 7/0. 7/0.37 7/0.0 7/ 7/ 7/1. 7/1. 7/2.1 7/2 19/8 19/2.1 19/2 37/3 37/2. 37/2 1/2. 1/2 1/2.85 1/3. Calculated Sectional Area 0.5 52 9 7 3.97 5..02.89.18 3.91 7.28 8.3 9.7 119.75 17.11 2.2 389.1 90.59 Overall 1 0 9 5.05 5..2 7.5 8.90. 1 1.21.75 17...8.5 28.80 5.09.8 7.90 13.85.1. 53.38 89.92 2.87 313.57 1.8 81 8.59 1332 175 1 75.72 9.98.0 Max Resistance at 3.0 2.5 1 7.1.1 8 3 0.52 0.28 0. 0.075 0.001 0.0 0.03 Length ( ) ( 1. ) ( ) ( 3.5 ) ( 5.5 ) ( 8 ) ( 1 ) ( ) 38 ( ) 0 ( 80 ) 0 ( 1 ) 1 0 0 3 00 0 ( 00 ) ( 7 ) ( 8 ) ( 1,000 ) 7/0. 7/0.5 7/0. 7/ 7/ 7/ 7/1. 7/ 7/ 7/2. 19/ 19/ 19/ 19/2. 19/2.9 37/ 37/2. 1/ 1/2. 1/2.9 1/3.2 91/2.9 91/3.2 7/2.9 7/3.2 2 13.2 9.18 5.17 3.31 2. 9 18 0.18 0.37 0.1 0.178 0.13 0.118 0.09 0.07 0.0 0.0 0.03 0.03 0.028 0.0217 0.0179 1 Koryo Cable
가공송배전선 Aluminium Stranded s Steel Reinforced (ACSR) Application Used for voltage overhead transmission lines Construction Aluminium Wire KS C 3113 / ES 05 가공송배전선 Aluminium Stranded s Steel Reinforced (ACSR) Galvanized Steel Wire ConcentricLayStranded Aluminium s Aluminiumclad Steel Reinforced(ACSR/AW) ACSR/AW Outdoor Tracking Retardant Crosslinked Polyethylene Insulated Wire for.9kv (ACSR/AWTR/OC) Aluminium ACSROutdoor Crosslinked Polyethylene Insulated Wire (ACSROC) Aluminium Stranded s Aluminiumclad Steel Reinforced Outdoor Crosslinked Polyethylene Insulated Wire (ACSR/AWOC) 19 * *58 80 * *97 * * 0 * *3 *80(R) *80(C) *5 Number & of Wire No. Tensile Load Current Carrying Capacity Aluminium Steel 0 / /2. /3.5 /.2 /.5 /3.2 /3.5 / /2. /2.9 /3.2 2/.0 2/.5 5/3.7 5/3.38 5/3.5 5/3.8 1/ 1/2. 1/3.5 1/.2 1/.5 7/3.2 7/3.5 7/ 7/2. 7/2.9 7/3.2 7/3.1 7/3.5 7/7 7/3.38 7/3.5 7/3.8.0 7.8.5. 13.5 17.5 18.2.3 2.3 28.5 29.1.2 3 3.2 98 1, 1,980 2,7 3,180,00 9,590 5,5,990 8,,2,9 13,890 11,800,,00 18,1 1 5 2 29 3 5 5 73 53 3 79 807 851 97 172 28 8 38 398 398 1 5 03 8 85 9 90 1,0 1 188 1 381 3 3 5 583 2 79 929 1,001 1,057 1,177 7. 8. 3.1 3.5 385.2.8 85. 573.7 7.8 91 1,1 1,0 1,73 1,599 1,83 1,99 2,0 Resistance 99 7 0. 0.1 0.2981 0.297 0.3 0.182 0.17 0. 0.0888 0.02 0.0599 0.0599 0.0559 0.07 Length 1,000 1,000 1,000 1,000 1, 1, 1, 1, 1, 1,00 1,00 1,000 1,000 1,000 1,000 1,000 1,000 1 Koryo Cable 17
가공송배전선 ConcentricLayStranded Aluminium s Aluminiumclad Steel Reinforced (ACSR/AW) Application Used for high voltage overhead transmission lines Construction AluminiumClad Steel Wire / Aluminium Stranded ES (KEPCO std.) ACSR/AW Outdoor Tracking Retardant Crosslinked Polyethylene Insulated Wire for.9kv (ACSR/AWTR/OC) Application Used for weatherresistant cable for the distribution lines on normal condition of overhead line service Construction AluminiumClad Steel Wire/Aluminium Stranded /Outdoor Tracking Retardant XLPE ES 21(KEPCO std.) Aluminium Clad Steel Wire Electric Harddrawn Aluminium Wire Aluminium Covered Steel Wire Nominal Sectional Area.9kV 58 Aluminium Steel Outer /SB /SB 18/SB 18/SB 1/3.5 1/3.5 1/3.2 1/.0 9.7 1. 18.9 Screen 0. 0. 0. 0. 1..7 19.0..0 Resistance at 0.2 0.183 0.3 Tensile Load 1900 2 80 0 5 7 0 Length 00 00 00 00 Aluminium ACSROutdoor Crosslinked Polyethylene Insulated Wire (ACSROC) Application Used for high voltage aerial transmission lines Construction s Aluminium Steel Reinforced XLPE Insulated Wire ES 07 Galvanized Steel Wire Aluminium 58 5 97 3 80(R) 80(C) 5 Number & of Wire No. Tensile Load Current Carrying Capacity Aluminium Steel 0 /2. /3.5 /2. /.5 /3.2 /3.5 /2. /3.2 2/.0 2/.5 5/3.7 5/3.38 5/3.5 1/2. 1/3.5 7/2. 1/.5 7/3.2 7/3.5 7/2. 7/3.2 7/3.1 7/3.5 7/7 7/3.38 7/3.5 7.8.5 1 13.5 17.5 18.2 2.3 28.5 29.1.2 3 1 1980 50 3180 00 90 990 2 9 13890 11800 10 9 8 313 382 2 558 1 7 81 89 177 5 1 1 29 78 7 88 921 981 193 8 29 372 385 52 89 817 79 1.2 21. 3.1 38. 73.7 87.8 2 92 1887 1 Resistance 52 1 0.3775 0.288 0.292 0.8 0.19 0.111 0.082 0.0 0.058 0.057 0.053 Length 00 00 00 00 00 00 00 00 00 00 00 00 00..9 Nominal Sectional Area 58 58 Reference Aluminium Steel Outer Screen Resistance at Tensile Load Length /SB /SB /SB /SB /SB /SB 18/SB 1/2. 1/3.5 1/3.5 1/2. 1/3.5 1/3.5 1/3.2 7.2 9.7 1 7.2 9.7 1. 3.5.0 1 17.0 13.2.7 19.0. 28 0.5 0.313 28 0.5 0.313 0.18 10 10 00 10 10 10 90 1900 2 90 1900 2 80 3 55 2 900 00 900 00 00 00 18 Koryo Cable 19
가공송배전선 Aluminium Stranded s Aluminiumclad Steel Reinforced Outdoor Crosslinked Polyethylene Insulated Wire (ACSR/AWOC) Application Used for high voltage aerial transmission lines Construction s Aluminium Clad Steel Wire / Aluminium Stranded XLPE Insulated Wire ES 0 Aluminium Clad Steel Wire 절연전선 /7V Singlecore Nonsheathed Cable with Rigid for General Purposes (IV) (07 KS IEC 01) /7V HalogenFree Flame Retardant PolyOlefin Insulated Wire (HFIX) /0V Singlecore Nonsheathed Cable with Solid for Internal Wiring (90 C) (HIV) (07 KS IEC 07) FRPVC Insulated Grounding Wire(TFRGV) 00V Outdoor Weather Proof PVC Insulated Wire (OW) High Drop Wire for Pole Transformer(SOLP.D.C) PVC Insulated Drop Service Wire (DV) Light Polyvinyl Chloride ed Cord Ordinary Polyvinyl Chloride ed Cord..9 Nominal Sectional Area 58 58 Reference Min Aluminium Steel Outer Resistance at Resistance at Tensile Load Length /SB /SB /SB /SB /SB /SB 18/SB 18/SB 1/2. 1/3.5 1/3.5 1/2. 1/3.5 1/3.5 1/3.2 1/.0 7.2 9.7 1 7.2 9.7 1. 18.9 3.5.0.0 1 17.0 13.2.7 19.0..0 77 0.2 77 0.2 0.183 0.3 10 10 00 10 10 10 00 90 1900 2 90 1900 2 80 0 180 3 5 2 3 5 7 0 00 00 00 00 00 00 00 00 Koryo Cable 21
절연전선 /7V Singlecore Nonsheathed Cable with Rigid for General Purposes (IV) (07 KS IEC 01) /7V HalogenFree Flame Retardant PolyOlefin Insulated Wire (HFIX) Application Used for inside of house building at max. conductor temperature Construction s :Plain or MetalCoated Annealed Copper Wire (Tinned Annealed Stranded Copper Wire up to are Available) : PVC Color of the : Black(If necessary black, white, red, green, yellow, blue) Maximum permissible temperature : KS C IEC 073(01) Application Used for inside of house building at max. conductor temperature 90 and insulated with halogenfree flame retardant polyolefin. Construction s :Plain or MetalCoated Annealed Copper Wire (Tinned annealed Stranded Copper Wire up to are available) : HalogenFree Flame Retardant PolyOlefin Color of the : Black(If necessary black, white, red, green, yellow, blue) Maximum permissible temperature : 90 KS C 331 Nominal Section Area Number & of wire Outer 1 1 00 1/1.38 1/8 7/ 1/2. 7/2 1/2.7 7/ 1/3.57 7/1. 1.38 9 8 2. 5 2.7 3.57.05.7 1.9 1. 1.2 1. 1. 2. 3.2 3.3 3.9.0.. 5.0 5.2..7 7.8 9.7.9.8 1. 17.1 18.8.9.3 2. 29. 33.2 Max Resistance at 7.1 7.1.1.1 8 8 3 3 0.52 0.28 0. 0.075 0.001 0.07 00 Min Resistance at 0.011 0.0 0.0 0.009 0.0085 0.0077 0.00 0.005 0.00 0.005 0.00 0.00 0.003 0.003 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.0028 2 3 55 75 1 1 2 3 5 85 9 11 1 18 25 29 38 Length 1 1 KS C IEC 08 1 2. 3.3 2 2.7 3. 1 3.2.0 2 3.3.1 7.1 1 3.. 2 3.8.7.1 1.1 5.2 8 2 1 2 1. 1. 1. 1. Min.3 5.3 5.. 9.0.. 17.3 19.3.0 2.5 Max 5.. 7.0 8.0.1 11.3 13.2.1 17. 19. 21. 2.1.5. Resistance at 3 0.52 0.28 0. 0.075 0.001 00 Length Koryo Cable
절연전선 /0V Singlecore Nonsheathed Cable with Solid for Internal Wiring (90 C) (HIV) (07 KS IEC 07) Application Used for chiefly in wiring of electric apparatus and equipment under /0V grade, and insulated with compound mainly composed of PVC resin including heatresistant plasticizer. Construction s :Plain or MetalCoated Annealed Copper Wire (Tinned Annealed Stranded Copper Wire up to are Available) : HeatResistant PVC Color of the : Black(If necessary black, white, red, green, yellow, blue) Maximum permissible temperature : 90 KS C IEC 073(07) FRPVC Insulated Grounding Wire (TFRGV) Application Used for grounding of electric apparatus. Construction s :Annealed Copper Wire (Concentric Circular, Compact Circular) : Flame Retardant PVC Color of the : Green KS C IEC 021 (Solid ) Nominal Section Area Number & of wire Outer 1/1.38 1/8 1.38 8 3.2 3.9 Max Resistance at 7.1 Min Resistance at 90 0.011 0.009 21 Length Nominal Section Area Number & of wire Outer 1 1 00 0 7/ 7/ 7/1. 9 5.05.7 11..9 1. 1.2 2..2 2. 2.8 3.1 3. 3.7.0.3..9 5.0.5 7.0 8.0 8.5 9.5.0 1 1.0.0.0 28.0.0 3.0 38.0 Max Resistance at 7.1.1 8 3 0.52 0.28 0. 0.075 0.001 0.0 0.03 0.0283 00 5 80 5 1 0 0 800 80 13 0 0 0 Length 0 2 Koryo Cable
절연전선 00V Outdoor Weather Proof PVC Insulated Wire (OW) Application Used for overhead lowvoltage distribution line and composed of harddrawn copper wire and PVC insulation. It is high weather proof and safe use. Construction s :HardDrawn Copper : PVC Color of the : Black KS C 3313 / ES 13 High Drop Wire for Pole Transformer (SOLP.D.C) Application Used for dropin from high voltage overhead line to the primary of the pole transformer. Construction s :HardDrawn Copper Wire or Annealed Copper Wire : XLPE Color of the insulation : Black ES 17 (Solid ) Max Resistance at Tensile Load Length 0. 2. 0.5 3.2 0..0 5.0 ( ) Number & of wire Outer 1 38 0 0 7/1. 7/ 7/2. 19/ 19/2..8.0 7.8.0 1 2.8 3...0 7. 1. 1. 5.83 3.5 8 1..8 8. 1.8 00 Max Resistance at 1. 9 0.2 0.313 0. 0 13 2180 0 890 7 Tensile Load 5 87 10 2 39 5 81 1 2 0 0 0 0 Length Number & of wire Outer 5.5 8 1 2. 3.2 5.0 7/ 7/ 7/1. 7/ 7/ 2. 3.2 5.0 3..8.0.0. Max Overall Resistance at 8.0 8. 9.2 1 9.0 9. 1 1 1 5.5 3. 1 05 3.33 1 1. 2 0. 00 00 00 000 00 00 00 00 00 Min Resistance at 00 00 00 000 000 00 00 00 00 Length Symbol PDC PDC PDC PDC PDC PDC PDC PDC PDC 2 Koryo Cable
절연전선 PVC Insulated Drop Service Wire (DV) Application Construction Chiefly used for dropin from overhead distribution line, and very convenient for wiring, color being easily identified. It is weather proof and can be used for a long period without damage due to fire, electrical shock and other accidents. and insulated with compound mainly composed of PVC resin including heatresistant plasticizer. s :Hard Drawn Copper Wire(but, ~ 0 is Annealed Copper Wire) : PVC Color Identification : 2 coresblack, green / 3 coresblack, green, blue Class & Symbols Double:DV2R / Triple:DV3R KS C 33 / ES 1 (Duplex DV2R) Number & of wire Outer 8 1 38 0 1/ 1/2. 1/3.2 7/ 7/1. 7/ 7/2. 19/ 2. 3.2 3..8.0 7.8.0 (Triplex DV3R) Number & of wire Outer 8 1 38 0 1/ 1/2. 1/3.2 7/ 7/1. 7/ 7/2. 19/ 2. 3.2 3..8.0 7.8.0 1. 1. 1. 1.. Overall 7.2 9.2 1 1.5 2 28.0. Overall 7.8 9.9 1 1 1.5 10 10 10 10 00 00 10 10 10 10 00 00 Min Resistance at 0 0 0 Min Resistance at 0 0 0 Tensile Load 211 3 57 18 7 1,080 Tensile Load 7 211 3 57 18 7 80 Max Resistance at 5.89 3.8 2. 3 1.3 2 0. Max Resistance at 5.89 3.8 2. 3 1.3 2 0. 75 1 190 5 5 80 1,3 1 190 285 3 5 785 90 190 Length Length Light Polyvinyl Chloride ed Cord Application Mainly used in home apparatus under /0V Construction s : Class 5(Bunchstranded Copper Wire) : PVC Color Identification : 2 coreslight blue, black / 3 coreslight blue, black, brown PVC KS C IEC 075(52) Nominal Sectional Area 25.5 35 Ordinary Polyvinyl Chloride ed Cord Nominal Sectional Area 25 21 2 2 35 31 3 3 5 1.75 51 5 5 0.5 0.5 0.5 0.5 0. 0. 0. 0. 0. 0. 0. 0. Application Mainly used in home apparatus under /0V Construction s :Class 5(Bunchstranded Copper Wire) : PVC Color Identification : 2 coreslight blue, black / 3 coreslight blue, black, brown coreslight blue, black, brown, brown / 5 coreslight blue, black, brown, brown, brown PVC KS C IEC 075(53) 0. 0. 0. 0. Min..9. 3..2.9 5.2 Min 5.7 3.7.0.8 8..0.3 7. 9.2. 7.1 8..1 7. 7.8 9.3 1 Max 3.7.3 3.8.3.3.7 Max 7.2.57.2 7.5 8.. 7. 8.0 9. 11. 8.3 9.0.5 1 9.3 11. 13.9 Min Resistance at 0.0 0.0 0.0 0.0 Min Resistance at 0.011 0.0 0.0 0.009 0.011 0.0 0.0 0.009 0.011 0.0 0.0 0.009 0.011 0.0 0.0 0.009 28 Koryo Cable 29
전력케이블 전력케이블 트레이용난연케이블의특징 0./1kV XLPE Insulated and Tray FlameRetardant PVC ed Cable (TFRCV) 0./1kV XLPE Insulated and Tray FlameRetardant PVC ed Aluminium Power Cable (TFRCV/AL) 0./1kV XLPE Insulated HalogenFree Flame Retardant PolyOlefin ed Power Cable(HFCO) 0./1kV XLPE Insulated PVC ed Flat Cable (CVF) 0./1kV XLPE Insulated PVC ed WaterProof Aluminium Power Cable(CVW/AL) 트레이용난연케이블의용도 트레이용난연케이블의인용규격 트레이용난연케이블의종류 0./1kV PVC Insulated PVC ed Cable(VV) /kv XLPE Insulated and Tray FlameRetardant PVC ed Cable (/kv TFRCV) /kv XLPE Insulated HalogenFree Flame Retardant PolyOlefin ed Power Cable (/kv HFCO).9kVy WaterProof Copper XLPE Insulated, Concentric Neutral with Water Swellable Tapes, and PVC(HalogenFree PolyOlefin Flame Retardant) ed Power Cable(.9kVy CNCVW, FR CNCOW) 용어설명.9kVy WaterProof Aluminium XLPE Insulated, Concentric Neutral with Water Swellable Tapes, and HalogenFree PolyOlefin Flame Retardant ed Power Aluminium Cable(.9kVy FR CNCOW/AL).9kVy WaterProof Copper TRXLPE Insulated, Concentric Neutral with Water Swellable Tapes, and Polyethylene Flame Retardant ed Power Cable (.9kVy TR CNCEW).9kVy WaterProof Aluminium TRXLPE Insulated, Concentric Neutral with Water Swellable Tapes, and Polyethylene Flame Retardant ed Power Aluminium Cable (.9kVy TR CNCEW/AL) 시험방법 평가방법 Koryo Cable 31
전력케이블 0./1kV XLPE Insulated and Tray FlameRetardant PVC ed Cable (TFRCV) Application Designed for the purpose of using in power distribution line, having excellent flame retardant. Construction s :Annealed Copper Wire : XLPE : FRPVC Color identification : 2 coresblack, white / 3 coresblack, white, red / coresblack, white, red, green KS C IEC 021/ KETI (Single Core) Filler Binder Tape Number & of wire Outer 1 1 00 0 7/ 7/ 7/1. 9 5.05.7 11..9 1. 1.2 2..2 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1..3.7 7.2 7.8 9. 13 1 2 3 37 2 00 Max Resistance at 7.1.1 8 3 0.52 0.28 0. 0.075 0.001 0.07 0.03 0.0283 53 5 81 8 5 2 3 1 52 71 2 79 2 1872 91 3975 89 283 Length 0 (Three Cores) Number & of wire Outer 1 1 7/ 7/ 7/1. 9 5.05.7 11..9 1. 1 1. 1. 2.1 2. 2.7 1 1 13.5 18 19.5 29 33 37 1 57 2 00 Max Resistance at 7.1.1 8 3 0.52 0.28 0. 0.075 0.001 18 189 1 9 975 87 193 83 3 03 80 5975 71 938 Length (Two Cores) Number & of wire Outer 1 1 7/ 7/ 7/1. 9 5.05.7 11..9 1. 1 1. 1. 2. 11 13 1 17 2 31 38 3 7 53 58 00 Max Resistance at 7.1.1 8 3 0.52 0.28 0. 0.075 0.001 7 3 197 2 7 87 7 93 19 85 2890 375 282 59 87 Length (Four Cores) Number & of wire Outer 1 1 7/ 7/ 7/1. 9 5.05.7 11..9 1. 1 1. 1. 2.1 2. 2.8 1 13.5 1 2 28 3 2 51 5 3 00 Max Resistance at 7.1.1 8 3 0.52 0.28 0. 0.075 0.001 179 5 397 585 81 1 11 31 08 51 7 78 038 9 Length Koryo Cable 33
전력케이블 0./1kV XLPE Insulated and Tray FlameRetardant PVC ed Aluminium Power Cable (TFRCV/AL) Application Designed for the purpose of using in power distribution line, having excellent flame retardant. Construction s :AI : XLPE : FRPVC KS C IEC 021(KS C IEC 08 AI ) (Single Core) Al (Two Cores) Number & of wire Outer 1 1 7/1..05.7 11..9 1. 1 1. 1. 2. 17 2 31 38 3 7 53 58 00 Max Resistance at 8 1 0 8 0.1 0.3 0.0 0.3 0. 0.1 0.1 0.0 9 39 79 8 1 98 1 19 09 51 Number & of wire Outer 1 1 00 0 (Single Core) Resistance at allowable current.7 11..9 1. 1.2 2..2 1. 1. 13 1 2 3 37 2 0.52 0.28 0. 0.075 0.001 0.07 0.03 0.0283 1 8 0.1 0.3 0. 0.3 0. 0.1 0.1 0.0 0.0778 0.005 0.09.7.9 17.2 3. 9.5 3 399.9 3.9 533.3 3.1 7.5 88.0 998.0 79.5 7.3 13. 17 21.. 8.5 8..8 9 57 93. 80.0 91. (Three Cores) Number & of wire Outer 1 1 7/1..05.7 11..9 1. 1 1. 1. 2.1 2. 2.7 18 19.5 29 33 37 1 57 2 00 Max Resistance at 8 1 0 8 0.1 0.3 0.0 0.3 0. 0.1 0.1 0.0 2 333 88 02 782 3 133 192 81 73 3989 Number & of wire Outer 1 1 00 0 7/1..05.7 11..9 1. 1.2 2..2 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 9. 13 1 2 3 37 2 00 Max Resistance at 8 1 0 8 0.1 0.3 0.0 0.3 0. 0.1 0.1 0.0 0.077 8 0.00 5 0.0 9 87 5 19 9 311 0 0 11 737 97 111 8 182 2 (Four Cores) Number & of wire Outer 1 1 7/1..05.7 11..9 1. 1 1. 1. 2.1 2. 2.8 2 28 3 2 51 5 3 00 Max Resistance at 8 1 0 8 0.1 0.3 0.0 0.3 0. 0.1 0.1 0.0 3 0 592 75 993 17 171 219 29 0 5 55 3 Koryo Cable
전력케이블 (Two Cores) 0./1kV XLPE Insulated HalogenFree Flame Retardant PolyOlefin ed Power Cable (HFCO) Application Designed for the purpose of using in power distribution line under 0./1kV having excellent low smoking & nontoxic and flame retardant. Construction s :Annealed Copper Wire(concentric circular, compact circular) : XLPE : HalogenFree Flame Retardant Polyolefin Color identification : Coloring Method(2 Cores Black, White /3 Cores Black, White, Red ) / White white or natural color Class and Symbols 0./1kV XLPE insulated halogen free flame retardant polyolefin sheathed power cable 0./1kV HFCO KS C IEC 021 Number & of wire Outer 1 1 (Three Cores) 7/ 7/ 7/1. 9 5.05.7 11..9 1. 1 1. 1. 2. 13 13 1 18 19 2 31 38 2 7 52 57 00 Max Resistance at 7.1.1 8 3 0.52 0.28 0. 0.075 0.001 7 3 197 2 7 87 7 93 19 85 2890 375 282 59 87 (Single Core) Number & of wire Outer 1 1 00 0 7/ 7/ 7/1. XLPE 9 5.05.7 11..9 1. 1.2 2..2 Filler Binder 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 8 8 9 9 11 13 1 17 19 21 28 3 38 2 00 Max Resistance at 7.1.1 8 3 0.52 0.28 0. 0.075 0.001 0.0 0.03 0.0283 53 5 81 8 5 2 3 1 52 71 2 79 2 1872 91 3975 89 283 Number & of wire Outer 9 7/ 5 7/ 7/1..05 1.7 11..9 1 1. 1 (Four Cores) Number & of wire Outer 1 1 7/ 7/ 7/1. 9 5.05.7 11..9 1. 1 1. 1. 1. 1. 2.1 2. 2.7 2.1 2. 2.8 13 1 1 19 2 29 33 37 1 5 5 1 1 1 18 2 28 37 1 5 55 2 8 00 00 Max Resistance at 7.1.1 8 3 0.52 0.28 0. 0.075 0.001 Max Resistance at 7.1.1 8 3 0.52 0.28 0. 0.075 0.001 18 189 1 9 975 87 193 83 3 03 80 5975 71 938 179 5 397 585 81 1 11 31 7 7 7 78 038 9 3 Koryo Cable 37
전력케이블 0./1kV XLPE Insulated PVC ed Flat Cable (CVF) Application Designed for the purpose of using in power distribution line for control system under 0./1kV having excellent electrical physical and chemical properties. Construction s :Annealed Copper Wire : XLPE Color identification : Colour Tape(3 cores Black, White, Red) KS C IEC 021 0./1kV XLPE Insulated PVC ed WaterProof Aluminium Power Cable (CVW/AL) Application Designed for the purpose of using in power distribution line for control system under 0./1kV. Construction s :Circular Compacted Stranded Filled with Water Blocking Tape Plain Annealed Copper : XLPE : PVC Color identification : 1 core Natural color /2 Cores Black, White 3 cores Black, White, Red / cores Black, White, Red, Green KS C IEC 021 Waterproof Al XLPE (Single Core) XLPE Number & of wire Outer 1 11..9 1. 1 1. 1. 1. 1. 1. 1. 1. 13 1 2 00 Max Resistance at 8 0.1 0.3 0.0 0.3 0. 0.1 0.1 0.0 18 3 311 05 93 0 738 92 15 Length 0 (Two Cores) (Three Cores Flat Type) Number & of wire Outer 1 7/ 7/ 7/1. 9 5.05.7 11. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1..313.8.7.0 7.3 7.818. 8.82 9..1 13..1.3 17..8 00 Max Resistance at 7.1.1 8 3 0.52 0.28 1 3 31 90 1 18 3 90 Length 0 Number & of wire Outer 1 11..9 1. 1 (Four Cores) Number & of wire Outer 1 11..9 1. 1 1. 1. 1. 1. 2.1 2. 2 31 38 3 7 28 3 2 51 5 00 00 Max Resistance at 8 0.1 0.3 0.0 0.3 0. 0.1 Max Resistance at 8 0.1 0.3 0.0 0.3 0. 0.1 7 08 809 0 82 82 198 7 99 1 1718 21 3 Length 0 Length 0 38 Koryo Cable 39
전력케이블 (Two Cores) 0./1kV PVC Insulated PVC ed Cable (VV) Application Superior weather proof and antifriction property, permitting of use for a long period of time and widely used under 0./1kV grade. Construction s :Annealed Copper Wire : PVC : PVC Color identification : 2 cores Black, White 3 cores Black, White, Red cores Black, White, Red, Green KS C IEC 021 (Single Core) Number & of wire Outer 1 1 00 0 7/ 7/ 7/1. 9 5.05.7 11..9 1. 1.2 2..2 1. 1. 2. 2.8 1. 1. 2.1 Filler Binder Tape.5 7.0 8.0 8.5 9.5.0 1 1.0.0.0 28.0.0 3.0 38.0 00 Max Resistance at 7.1.1 8 3 0.52 0.28 0. 0.075 0.001 0.0 0.03 0.0283 5 75 5 1 180 2 05 790 5 13 0 00 1 05 Number & of wire Outer 1 1 (Three Cores) Number & of wire Outer 1 1 (Four Cores) Number & of wire Outer 1 1 7/ 7/ 7/1. 7/ 7/ 7/1. 7/ 7/ 7/1. 9 5.05.7 11..9 1. 1 9 5.05.7 11..9 1. 1 9 5.05.7 11..9 1. 1 1. 1. 1. 1. 1. 1. 2.1 2.7 2.1 2.7 2.8 2. 2.9 3.1 1 1.5 17.0 2 31 38 3 7 53 58 1 1.0 18.0 19.0 2 29 33 38 1 57 3 1 17.5.0 2 28 3 2 51 5 3 00 00 00 Max Resistance at 7.1.1 8 3 0.52 0.28 0. 0.075 0.001 Max Resistance at 7.1.1 8 3 0.52 0.28 0. 0.075 0.001 Max Resistance at 7.1.1 8 3 0.52 0.28 0. 0.075 0.001 1 2 290 00 5 775 00 1 1775 90 290 3 0 55 7 2 2 3 5 5 5 1 18 5 33 1 85 805 05 0 0 0 55 8 13 1755 2 00 5 5380 5 85 5 10 0 Koryo Cable 1
전력케이블 /kv XLPE Insulated and Tray FlameRetardant PVC ed Cable (/kv TFRCV) /kv XLPE Insulated HalogenFree Flame Retardant PolyOlefin ed Power Cable (/kv HFCO) Application Designed for the purpose of using in power, distribution line, having excellent electrical, physical and chemical properties. Construction s :Annealed Copper Wire(concentric circular, compact circular) : XLPE : FRPVC Color identification : 1 core Natural color 3 cores Black, White, Red KS C IEC 022 Screen Screen Cu Tape Filler Binder Tape Application Designed for the purpose of using in power distribution line under /kv having excellent low smoking & nontoxic and flame retardant. Construction s :Annealed Copper Wire(Concentric Circular, Compact Circular) : XLPE : Halogen Free Flame Retardant Polyolefin Color Identification : Coloring Method(1 core Natural /3 cores Black, White, Red ) White White or Natural color Class and Symbols /kv XLPE insulated halogen free flame retardant polyolefin sheathed power cable /kv HFCO KS C IEC 021 Screen Screen Cu Tape Filler Binder Tape (Single Core) Number & of wire Outer 1 1 00 0.7 11..9 1. 1.2 2..2 (Three Cores) Number & of wire Outer 1 1.7 11..9 1. 1 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 1. 1. 2.1 2. 2.7 2.8 2.9 3.1 21 28 37 0 3 8 39 1 3 53 57 0 9 7 0 0 Max Resistance at 0.52 0.28 0. 0.075 0.001 0.0 0.03 0.0283 Max Resistance at 0.52 0.28 0. 0.075 0.001 55 90 8 0 13 5 1905 2 2855 5 580 990 18 0 290 5 5380 7 83 9 (Single Core) Number & of wire Outer 1 1 00 0.7 11..9 1. 1.2 2..2 (Three Cores) Number & of wire Outer 1 1.7 11..9 1. 1 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 3. 1. 1. 2.1 2. 2.7 2.8 2.9 3.1 21 28 37 0 3 8 39 1 3 53 57 0 9 7 0 0 Max Resistance at 0.52 0.28 0. 0.075 0.001 0.0 0.03 0.0283 Max Resistance at 0.52 0.28 0. 0.075 0.001 55 90 8 0 13 5 1905 2 2855 5 580 990 18 0 290 5 5380 7 83 9 2 Koryo Cable 3
전력케이블.9kVy WaterProof Copper XLPE Insulated, Concentric Neutral with Water Swellable Tapes, and PVC(HalogenFree PolyOlefin Flame Retardant) ed Power Cable (.9kVy CNCVW, FR CNCOW) Application Used for.9kvy concentric neutral type water tree retardant XLPE insulated extrude to fill polyethylene jacketed waterproof power cable. Construction s :Circular Compacted Stranded Filled with Water Blocking Compound or Tape Plain Annealed Copper : 90, Extruded Crosslinked Polyethylene with Semiconductive Inner and Outer Screen Neutral : Annealed Copper Wire with Waterblocking Tapes : PVC(CNCVW), HalogenFree PolyOlefin(FR CNCOW) ES 19 Waterproof Copper.9kVy WaterProof Aluminium XLPE Insulated, Concentric Neutral with Water Swellable Tapes, and HalogenFree PolyOlefin Flame Retardant ed Power Aluminium Cable (.9kVy FR CNCOW/AL) Application Construction Used for.9kvy multigrounded power distribution circuits in industrial and commercial installation. It may be installed on conduit, duct, tray or directly buried. Safe from ingress of humidity. s : Circular Compacted Stranded Aluminium Filled with Water Blocking Compound or Tape : 90, Extruded Crosslinked Polyethylene with Semiconductive Inner and Outer Screen Neutral : Annealed Copper Wire with Waterblocking Tapes : PVC GS8 Screen XLPE Screen SemiConductive Water Swellable Tape Concentric Neutral NonConductive Water Swellable Tape Halogen free Polyolefin Waterproof Aluminium Screen TRXLPE Screen SemiConductive Water Swellable Tape Concentric Neutral NonConductive Water Swellable Tape Halogen free Polyolefin 38 0 0 1 0 0 3 00 0 00 Construction Outer 7.3 9.3 1 17.0 19.0 2 2.1 2 29.5..0 3 3 0 3 5 8 51 5 57 1 Max Resistance at 1 0.5 0.183 0.1 0.09 0.0739 0.058 0.02 0.039 0.08 Min Resistance at 00 0 00 10 10 10 Nominal Section Area 00 Construction Outer 11..2.80 0 0 37. 8. 53.5 Max Resistance at 0.0 0.1 0.0778 Min Resistance at 0 2. 2.7 3 33.92 3. 39.07 Koryo Cable 5
전력케이블.9kVy WaterProof Copper TRXLPE Insulated, Concentric Neutral with Water Swellable Tapes, and Polyethylene Flame Retardant ed Power Cable (.9kVy TR CNCEW) Application Used for.9kvy concentric neutral type water tree retardant XLPE insulated extradedtofill polyethylene jacketed waterproof power cable. Construction s :Circular Compacted Stranded Filled with Water Blocking Compound or Tape Plain Annealed Copper : 90, Extruded Crosslinked Polyethylene with Semiconductive Inner and Outer Screen Neutral : Annealed Copper Wire with Waterblocking Tapes : PVC ES.9kVy WaterProof Aluminium TRXLPE Insulated, Concentric Neutral with Water Swellable Tapes, and Polyethylene Flame Retardant ed Power Aluminium Cable (.9kVy TR CNCEW/AL) Application Used for.9kvy concentric neutral type water tree retardant XLPE insulated extradedtofill polyethylene jacketed waterproof power Aluminium cable. Construction s :Circular Compacted Stranded Aluminium Filled with Water Blocking Compound or Tape : 90, Extruded Crosslinked Polyethylene with Semiconductive Inner and Outer Screen Neutral : Annealed Copper Wire with Waterblocking Tapes : PVC ES2 Waterproof Copper Screen XLPE Screen SemiConductive Water Swellable Tape Concentric Neutral Polyethylene Waterproof Aluminium Screen XLPE Screen SemiConductive Water Swellable Tape Concentric Neutral Polyethylene Nominal Section Area 0 0 3 00 Construction Outer 9.3 17.0 2 29.5.80 2 9.5 59 Max Resistance at 0.5 0.09 0.058 0.08 Min Resistance at 0 10.3.2.1.1 37.5 3.1 5.1 Nominal Section Area 00 Construction Outer 11..2.80 0 0 3. 3.8.7 Max Resistance at 0.0 0.1 0.0778 Min Resistance at 0 2. 2.7 3 33.92 3. 39.07 Koryo Cable 7
제어케이블 0./1kV PVC Insulated and Tray FlameRetardant PVC ed Control Cable(TFRCVV) 0./1kV PVC Insulated and Tray FlameRetardant PVC ed Control Cable with Copper Tape Shield (TFRCVVS) 8 Koryo Cable 9
제어케이블 0./1kV PVC Insulated and Tray FlameRetardant PVC ed Control Cable (TFRCVV) Application Used in remote control system in power plant and substation. It is lighter and more flexible than conventional rubber insulated lead sheathed control cable, also excellent in fire proof and antiabrasion quality. Construction s :Annealed Copper Wire : PVC Core Identification : Coloring Method below cores(2 cores Black, White /3 cores Black, White, Red ) Numbering Method (Above 5 cores) : PVC Class and Symbols PVC Insulated PVC ed Control Cable:CVV PVC Insulated PVC ed Control Cable (Solid Type):CVS PVC Insulated PVC ed Control Cable (Shield Type):CVVS, CVVSB FlameRetardant PVC Insulated PVC ed Control Cable:FRCVV FlameRetardant PVC Insulated PVC ed Control Cable (Shield Type):TFRCVVS KETI PVC Filler Binder FlameRetardant PVC No. of Cores 2 3 5 7 8 Number & of wire Outer 9 7/ 5 7/ 9 7/ 5 7/ 9 7/ 5 7/ 9 7/ 5 7/ 9 7/ 5 7/ 9 7/ 5 7/ 9 7/ 5 7/ 9 7/ 5 7/ 9 7/ 5 7/ 9 7/ 5 7/ 9 7/ 5 7/ 9 7/ 5. Overall 11 1 1 1 1 1 13.5 1 17 13.5 17.5 21.5 21.5 1.5 18 19.5 2 2 19.5 2 29 2 29 2 28 Max Resistance at 7.1.1 8 7.1.1 8 7.1.1 8 7.1.1 8 7.1.1 8 7.1.1 8 7.1.1 8 7.1.1 8 7.1.1 8 7.1.1 8 7.1.1 8 7.1.1 00 00 00 00 00 00 00 00 00 00 00 00 133 13 8 28 3 287 192 2 2 51 9 290 18 5 338 92 280 53 8 9 17 13 801 393 5 7 05 5 587 873 111 51 85 9 5 8 1 1821 92 13 199 Koryo Cable 51
제어케이블 0./1kV PVC Insulated and Tray FlameRetardant PVC ed Control Cable with Copper Tape Shield (TFRCVVS) Application Designed for use in remote control system in power plant and substation. It is lighter and more flexible than conventional rubber insulated lead sheathed control cable, also excellent in fire proof and antiabrasion quality. Construction s :Annealed Copper Wire : PVC Core identification : Coloring Method below cores(2cores Black, White /3cores Black, White, Red /cores Black, White, Red, Green) Numbering Method(Above 5cores) : PVC Class and Symbols PVC Insulated PVC ed Control Cable:CVV PVC Insulated PVC ed Control Cable (Solid Type):CVS PVC Insulated PVC ed Control Cable (Shield Type):CVVS, CVVSB FlameRetardant PVC Insulated PVC ed Control Cable:FRCVV FlameRetardant PVC Insulated PVC ed Control Cable (Shield Type):TFRCVVS KETI PVC Filler Binder Cu tape Binder tape FlameRetardant PVC No. of Cores 2 3 5 7 8 Number & of wire Outer 9 7/ 5 7/ 9 7/ 5 7/ 9 7/ 5 7/ 9 7/ 5 7/ 9 7/ 5 7/ 9 7/ 5 7/ 9 7/ 5 7/ 9 7/ 5 7/ 9 7/ 5 7/ 9 7/ 5 7/ 9 7/ 5 7/ 9 7/ 5. Overall 1 1.5 13 1.5 13 1.5 17.5 1 17.5 19 1 19 1 19 1 17 21 2 19 21 21 29 33 29 Max Resistance at 7.1.1 8 7.1.1 8 7.1.1 8 7.1.1 8 7.1.1 8 7.1.1 8 7.1.1 8 7.1.1 8 7.1.1 8 7.1.1 8 7.1.1 8 7.1.1 00 00 00 00 00 00 00 00 00 00 00 00 18 7 3 182 7 317 3 21 1 38 88 319 5 55 29 3 5 91 9 398 57 752 31 52 57 89 31 55 8 3 8 9 7 558 7 1 3 9 139 187 983 1331 1992 52 Koryo Cable 53
통신케이블 5CHFBT, 7CHFBT, CHFBT 통신케이블 5CHFBT, 7CHFBT, CHFBT Unshielded Twisted Pair Category 5 (Pr/Pr) Unshielded Twisted Pair Enhanced Category 5E (Pr) Application Interconnection of satellite broadcast television and attachment machines used to receive. Reflection signal transmission system and data transmission etc are available. Construction s :Annealed Copper Wire : PPE / HFPE s : 1. Aluminium Myar tape Aluminium Braided wire Aluminium Myar tape : PVC Al Tape Braid Shield Al Tape Model 5CHFBT 7CHFBT CHFBT s s Outer Annealed copper wire 1/5 1/ 1/ Material Outer 5.0 7.3 9. s Construction Outer 7..1 1 Characteristic Impedance 75 75 75 Capacity 5 Attenuation 77.2 55.1 98.9 7 5.0.0.5 97.3 5 Koryo Cable 55
통신케이블 Unshielded Twisted Pair Category 5 (Pr/Pr) Unshielded Twisted Pair Enhanced Category 5E (Pr) Model CM / CMR CMP HDPE TEFLON FRPVC LSPVC What is a UTP cable? It is a shortcut word of unshielded twisted pair cable, and it is for 0 unshielded highspeed signal cable used for transmission of multimedia such as voice, data, and imagesequence,etc.,and it is very essential to build up a LAN, ATM, intelligent buildings,super highspeed telecommunication network, etc. and UTP cable has a function of transmitting speed of an opticalcable by using copper wire, so that its installation is easy and the cost for installation is cheaper. Model CM / CMR CMP Model CM/CMR CMP CM/CMR CMP (Electric Special Quality) NEXT SRL Frequency Characteristic Impedance Attenuation 72 1 8 1 0 5 Koryo Cable 0 0 0 0 0 0 0 0 0 0.1 5.8.5 8.2 9.3. 1 17.0.0 HDP HDPE+FRPE skin TEFLON Division Overall 0 8 5.0 5.0 59.5 59.5.0 5 8.0 7.0.0 39.0.0.0 FRPVC PVC/FRPVC LSPVC Package Box Box Reel Reel 21 18 1 (Product Name) (Application Specification) (Typical Use) Model CM / CMR CMP Division Overall 0 8 (Electric Special Quality) (Product Name) (Application Specification) Package (Typical Use) 5.0 5.0 PrPr NEXT Power Sum NEXT ACR PrPr FEXT Power Sum ELFEXT Frequency Characteristic Impedance Attenuation 72 1 8 1 0 0 0 0 0 0 0 0 0 0 0.1 5.8.5 8.2 9.3. 1 17.0.0 7.0 5.3 5.3 5.3 7.3 5.8.3 2.9 38..3 Box Box.0 53.3 8.8 7.3.3 2.8 1.3 39.9..3 5.2 3.3 5.0 3.8 39.1 3.5 33.9 3 21. 13.3.0 3.8 5 5.7 3.8 39.7 37.7.8 33.9.8.8 8.7 2.7 3.7 3.7.8.9 2.8 2 57
소방케이블 0./1kV XLPE Insulated with FireProof Layer and Tray FlameRetardant PVC ed FireRetardant Power Cable (TFR8) 소방케이블 0./1kV XLPE Insulated with FireProof Layer and Tray FlameRetardant PVC ed FireRetardant Power Cable (TFR8) 0./1kV XLPE Insulated and Tray FlameRetardant PVC ed HeatRetardant Control Cable (TFR3) Application Used for fire related equipment such as fire alarms, sprinkler system, emergency lighting circuits required fire resistant properties. Construction s :Circular Stranded Annealed Copper FireProof Layer:The Fireproof Layer Shall be Applied Between and : CrossLinked Polyethylene(XLPE) Assembly : Multicores or Cable Shall be Assembled with a Fireprotect Layer :FR PVC Core Identification:1core black 2cores black, white 3cores black, white, red cores black, white, red, green FireResisting 7/3hour KS C IEC 021 / KS C IEC 033 FireProof Layer (Single Core) Number & of wire Outer 1 1 00 0 7/ 7/ 7/1. 5.05.7 11..9 1. 1.2 2..2 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 2.1 8.0 8.5 9.0.5 13 1.5 21 33 37 2 00 Max Resistance at 7.1.1 8 3 0.52 0.28 0. 0.075 0.001 0.0 0.03 0.0283 81 1 1 17 2 3 37 59 785 53 17 55 190 7 2 028 3 311 58 Koryo Cable 59
소방케이블 (Two Cores) Number & of wire Outer 1 1 7/ 7/ 7/1. 5.05.7 11..9 1. 1 (Three Cores) Number & of wire Outer 1 1 (Four Cores) Number & of wire Outer 1 1 7/ 7/ 7/1. 7/ 7/ 7/1. 5.05.7 11..9 1. 1 5.05.7 11..9 1. 1 1. 1. 1. 1. 1. 1. 2. 2.8 2.1 2. 2.8 2.9 2.1 2. 2.7 3.2 1 1 18 19 31 38 2 7 52 57.5 17 19 2 2 29 33 37 1 5 5 1 1 17 21 2 29 37 1 5 2 9 00 00 00 Max Resistance at 7.1.1 8 3 0.52 0.28 0. 0.075 0.001 Max Resistance at 7.1.1 8 3 0.52 0.28 0. 0.075 0.001 Max Resistance at 7.1.1 8 3 0.52 0.28 0. 0.075 0.001 3 29 8 18 58 789 19 13 1803 90 2992 85 07 559 18 7 387 5 7 5 1377 1781 282 38 1 975 1 7800 980 292 377 75 7 919 13 1755 13 37 57 89 8018 8 8 0./1kV XLPE Insulated and Tray FlameRetardant PVC ed HeatRetardant Control Cable (TFR3) Application Used for operation and interconnection of fire alarm and emergency information equipment. Construction s :Circular Stranded Annealed Copper : 90 Cross Linked Polyethylene (XLPE) Assembly : Multicores or Cable Shall be Assembled to Form a Circular Cable with a Fireprotect Layer Fire Proof Layer : The Fireproof Layer Shall be Applied Between the Assembly and : FR PVC Core Identification: Core Type 1 core white / 2 cores blue, red / 3 cores blue, red, white / cores blue, red, white, white Above cores color tracer coding (Tracer color : blue, red) Pair Type 1 pair bluered / 2 pairs bluewhite, redwhite / Above 3 pairs color tracer coding FireResisting 380/3hour KS C IEC 021 / KS C IEC 033 FireProof Layer 0 Koryo Cable 1
2 3 5 7 8 00 00 00 00 00 00 00 00 00 00 00 00 00 3 2 Koryo Cable 소방케이블 Number & of wire Outer. Overall Max Resistance at No. of Cores 1/1.38 1/8 1/2. 1/1.38 1/8 1/2. 1/1.38 1/8 1/2. 1/1.38 1/8 1/2. 1/1.38 1/8 1/2. 1/1.38 1/8 1/2. 1/1.38 1/8 1/2. 1/1.38 1/8 1/2. 1/1.38 1/8 1/2. 1/1.38 1/8 1/2. 1/1.38 1/8 1/2. 1/1.38 1/8 1/2. 1/1.38 1/8 1/2. 1.38 8 2. 1.38 8 2. 1.38 8 2. 1.38 8 2. 1.38 8 2. 1.38 8 2. 1.38 8 2. 1.38 8 2. 1.38 8 2. 1.38 8 2. 1.38 8 2. 1.38 8 2. 1.38 8 2. 11 1 1 11 13 13 1 13 1 13.5 1 13.5 1 1 17.5 1.5 18 17 21 18 28 2 2 29 7.1.1 7.1.1 7.1.1 7.1.1 7.1.1 7.1.1 7.1.1 7.1.1 7.1.1 7.1.1 7.1.1 7.1.1 7.1.1 1 1 183 172 1 291 1 37 2 3 05 3 0 2 8 1 3 2 07 3 98 93 31 03 839 52 757 78 52 9 13 75 7 3 2 3 5 7 8 00 00 00 00 00 00 00 00 00 00 00 00 00 Number & of wire Outer. Overall Max Resistance at No. of Cores 7/ 7/ 7/ 7/ 7/ 7/ 7/ 7/ 7/ 7/ 7/ 7/ 7/ 9 5 9 5 9 5 9 5 9 5 9 5 9 5 9 5 9 5 9 5 9 5 9 5 9 5 11 13 1 1 13.5 1 13.5 13.5 1.5 17.5 17 1.5 17.5 19 21 18 19.5 19 21 2 21 2 2 2 29 28 31 7.1.1 7.1.1 7.1.1 7.1.1 7.1.1 7.1.1 7.1.1 7.1.1 7.1.1 7.1.1 7.1.1 7.1.1 7.1.1 131 1 1 18 1 5 2 28 3 31 2 339 0 28 37 52 37 0 03 52 72 3 878 581 788 1 3 91 1372 811 1117 3
부록허용전류 1 1 00 0 2 55 77 5 11 17 21 9 00 533 3 73 88 998 11 2 3 9 3 8 1 19 2 289 2 73 52 1 71 892 2 5 75 0 7 8 192 2 298 3 399 5 538 21 75 2 3 5 73 1 1 173 213 2 287 33 19 7 29 37 1 79 1 1 1 178 211 1 1 39 1 1 00 0 19 28 3 7 85 11 13 17 2 5 1 372 7 587 89 789 905 0 51 9 119 18 180 2 282 8 379 3 51 593 3 3 0 80 1 3 19 8 319 3 97 29 38 7 3 81 1 18 183 21 2 8 3 31 08 18 2 31 39 52 7 8 3 1 1 179 3 2 8 297 33 1 1 00 0 17 3 3 39 2 81 5 7 739 837 5 10 9 1 3 1 398 55 531 0 113 1 172 3 2 293 3 39 52 572 7 807 1 9 3 181 1 298 33 377 3 89 1 1 00 19 2 5 1 81 131 8 0 21 8 318 2 8 579 31 2 5 75 0 133 1 198 3 07 5 28 751 Koryo Cable 5
부록허용전류 0 5 55 0 5 75 80 85 90 2 7 1. 7 9 1 0.1 0. 0 0 0. 0 0 0 5 1 8 7 0. 9 2 2 2 0.5 5 7 0 1. 8 1 7 2 1 0.5 0.58 0. 0.1 0.0 3 0. 5 0 0.57 2 0. 3 9 1 2 3 5 7 8 9 1 0.5 2 0.3 3 9 0 7 3 5 7 0.57 0.5 0.52 1 0.2 2 8 0. 0. 0.1 2 8 1 7 2 8 0 5 0. 0.5 0.0 0.5 0.0 0. 0.5 0.1 0.38 Koryo Cable