www.supremainc.com QUICK GUIDE Version.00 ML 20.00.BSA2 V.00A
Cables and Connectors English Power Connectors Pin Name Color PWR +VDC Red(White Stripe) 2 2 PWR GND Black(White Stripe) Relay RLY NO White 2 RLY COM Blue RLY NC Orange RS-85 85 TRXP Blue 2 85 TRXN Yellow 85 GND Black SH GND Gray TTL Input TTL IN0 Red 2 TTL IN Yellow TTL GND Black SH GND Gray Wiegand Input / Ouput WG D0 Green 2 WG D White WG GND Black SH GND Gray Note To get more details and download the drivers, guides and BioStar 2, visit www.supremainc.com.
Standalone Connection Door Button Door Sensor Cable Shield (Option) IMPORTANT! The device and the electric door lock must use independent power source. Otherwise, it may cause your device to malfunction. Fail Secure Lock Or Fail Safe Lock Hub DC Power Deadbolt / Door Strike PC 2 DC Power Automatic Door Connection Wiegand Connection Wiegand IN Door Lock Door Button Presence Detector RFID Reader / Controller Cable Shield (Option) Door Controller Wiegand OUT 2 Controller Cable Shield (Option)
Secure I/O 2 Connection English DC Power Cable Shield (Option) 2 Secure I/O 2 DC Power Hub Door Sensor DC Power PC Door Lock Door Button IMPORTANT! The device, Secure I/O 2, and the electric door lock must use independent power source. Otherwise, it may cause your device to malfunction. For more information about Secure I/O 2 installation, visit www.supremainc.com.
FCC Compliance Information THIS DEVICE COMPLIES WITH PART 5 OF THE FCC RULES. Operation is subject to the following two conditions; () This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 5 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. Modifications not expressly approved by the manufacturer could void the user's authority to operated the equipment under FCC rules. This appliance and its antenna must not be co-located or operation in conjunction with any other antenna or transmitter. A minimum separation distance of 20 cm must be maintained between the antenna and the person for this appliance to satisfy the RF exposure requirements. EU Declaration of Conformity (CE) This product is CE marked according to the provisions of the R&TTE Directive(999/5/EC). Hereby, Suprema Inc. declares that this product is in compliance with the essential requirements and other relevant provisions of Directive 999/5/EC. This device is Class radio equipment under the European Radio and Telecommunications Terminal Equipment (R&TTE) Directive (999/5/EC). For more information, contact us at the following contact information. Suprema Inc. Website : https://www.supremainc.com Address : Parkview Tower F6, 28, Jeongjail-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea (Jeongja-dong 6) Tel: +82--78-502 / Fax: +82--78-50
케이블및커넥터 커넥터핀이름색상 전원 2 PWR +VDC 빨간색 ( 흰띠 ) 2 PWR GND 검정색 ( 흰띠 ) 한국어 릴레이 RLY NO 흰색 2 RLY COM 파란색 RLY NC 주황색 RS-85 85 TRXP 파란색 2 85 TRXN 노란색 85 GND 검정색 SH GND 회색 TTL 입력 TTL IN0 빨간색 2 TTL IN 노란색 TTL GND 검정색 SH GND 회색 Wiegand 입출력 WG D0 초록색 2 WG D 흰색 WG GND 검정색 SH GND 회색 알아두기 설치가이드, BioStar 2, 드라이버파일등을다운로드받거나제품에대한자세한내용을확인하려면, 슈프리마웹사이트 (www. suprema.co.kr) 에접속하십시오. 5
독립형연결 출입문스위치 출입문센서 케이블실드 ( 옵션 ) 중요! 장치와전기정 ( 전기식잠금장치 ) 은반드시개별전원을사용하십시오. 전원을함께연결하여사용하면장치가오작동할수있습니다 Fail Secure Lock Or Fail Safe Lock 허브 DC 전원 데드볼트 / 도어스트라이크 PC 2 DC 전원 자동문연결 Wiegand 연결 출입문잠금장치 출입문스위치 감지센서 Wiegand IN RFID 리더 / 제어장치 케이블실드 ( 옵션 ) 자동문제어장치 Wiegand Out 6 제어장치 케이블실드 ( 옵션 )
Secure I/O 2 연결 한국어 DC 전원 케이블실드 ( 옵션 ) 2 2 Secure I/O 2 DC 전원 허브 출입문센서 DC 전원 PC 출입문잠금장치 출입문스위치 중요! 장치, 전기정 ( 전기식잠금장치 ), Secure I/O 2 는반드시개별전원을사용하십시오. 전원을함께연결하여사용하면장치가오작동할수있습니다 Secure I/O 2 설치에대한자세한내용은슈프리마웹사이트 (www.suprema.co.kr) 에접속하여확인하십시오. 7
FCC 준수정보 이기기는 FCC 규제의 Part 5 를준수합니다. 작동은다음의두조건을따릅니다. () 이기기는해로운전파방해를발생시키지않습니다. (2) 이기기는원치않는작동을일으키는전파방해를포함한어떠한전파방해도수용합니다. 참고 : 이기기는 Class B 디지털기기에대한제한사항을준수하여테스트를거쳤고 FCC 규제의 Part 5 에적합하다는것을검증받았습니다. 이러한제한은주거설치에서해로운전파방해로부터적정한수준의보호를제공하기위해고안되었습니다. 이장비는무선주파수에너지를생성, 사용및방사하므로지침에따라설치하여사용하지않을경우무선통신에서유해한간섭을일으킬수있습니다. 그러나특정한설치에서는전파방해가발생하지않는다는어떠한보장도하지않습니다. 본장비를켜거나끌때라디오또는 TV 수신에해로운전파방해를일으키는경우, 다음중하나이상의조치를수행하여전파방해를해결하십시오. 수신안테나의방향을조정하거나재설치합니다. 장비와수신기사이의간격을늘립니다. 장비를수신기가연결된회로와다른회로의콘센트에연결합니다. 판매업체나숙련된라디오 /TV 기술자에게문의합니다. 제조업체가승인하지않은제품변경또는개조에대해서는 FCC 규칙에따라제품을사용할수있는권리가무효화됩니다. 유럽연합적합성선언 (CE) 이제품은 R & TTE (999/5/EC) 지침의규정에따라 CE 마크를제공합니다. 슈프리마는이문서에서설명하는장치에유럽연합라디오및통신단말기장치지침 (R&TTE 999/5/EC) 을준수하는 CE 마크가있음을선언합니다. 이장치는지침에따라클래스 라디오장치입니다. 더자세한내용은아래연락처로연락하십시오. 슈프리마웹사이트 : http://www.suprema.co.kr 주소 : 경기도성남시분당구정자일로 28 ( 정자동 6) 파크뷰타워 6 층 전화 : 0-78-50 / 팩스 : 0-78-57 8
www.supremainc.com Tel +82--78-502 Fax +82--78-50 Sales information sales@supremainc.com Technical support support@supremainc.com