Sun ZFS Storage 7120, 7320, 7420 Appliance : E39000 01 2012 12 E39000 01
Copyright 2009, 2011, 2012, Oracle and/or its affiliates. All rights reserved.,.,,,,,,,,,,,,.,...,. U.S. GOVERNMENT END USERS: Oracle programs, including any operating system, integrated software, any programs installed on the hardware, and/or documentation, delivered to U.S. Government end users are "commercial computer software" pursuant to the applicable Federal Acquisition Regulation and agency-specific supplemental regulations. As such, use, duplication, disclosure, modification, and adaptation of the programs, including any operating system, integrated software, any programs installed on the hardware, and/or documentation, shall be subject to license terms and license restrictions applicable to the programs. No other rights are granted to the U.S. Government..., -,,. Oracle Corporation. Oracle Java Oracle Corporation /.. Intel Intel Xeon Intel Corporation. SPARC SPARC International, Inc.. AMD, Opteron, AMD, AMD Opteron Advanced Micro Devices. UNIX The Open Group. ( ) 3,. Oracle Corporation 3,. Oracle Corporation 3,,. 130321@25097
...7 1...9...9...9 Hardware... 12... 13 BUI... 13 CLI... 19... 21 2...23... 23... 23 7120... 24 7120... 24... 24... 27... 27... 33... 34 7320... 34 7320... 34... 35 7320... 40 7320... 41 7420... 44 3
7420... 44... 44... 46... 47 7420... 50... 53 7x20... 53 7x20 CRU... 53... 54... 54... 54... 55... 55 Shelf... 78 Disk Shelf... 78 Shelf... 93 Disk Shelf... 93... 93... 94... 94 Disk Shelf... 94... 95... 105... 105 HBA 1... 106 HBA 2 3... 106 HBA 2... 110 HBA 3 4... 110 HBA 3... 115 HBA 4 5... 115 HBA 4... 119 HBA 5 6... 119 3...125 System... 125 4 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
... 125... 125... 126... 127... 128... 128... 128... 136... 138... 139 BUI... 141 CLI... 142 Passthrough x... 145 Passthrough-x... 145... 146... 146 COMSTAR... 146 COMSTAR... 146 3 RAID... 147 3 RAID... 147... 147... 147... 147... 147... 148... 148 Slim ZIL... 148... 148... 149... 149... 149... 149... 149... 149 RAIDZ... 150 RAIDZ/... 150 5
... 150... 150... 150... 150... 155... 155... 155... 156... 156... 156... 156 BUI... 158 CLI... 159... 161 6 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
Sun ZFS Storage 7120, 7320 7420 Appliance NAS Oracle Sun ZFS Storage 7x20. Help.. Sun ZFS Storage 7x20 Appliance.,,., (http://www.oracle.com/technetwork/ documentation/) URL. 7
( ) 3,. Oracle Corporation 3,. Oracle Corporation 3,,. Oracle Oracle My Oracle Support. http://www.oracle.com/pls/topic/lookup?ctx=acc&id=info http://www.oracle.com/pls/topic/lookup?ctx=acc&id=trs( ). 8 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
1 Sun ZFS Storage 7000. 7120 7320 7420 : 7110 7210 7310 7410 Disk Shelf : J4400/J4500 9
Sun ZFS Storage. SMB NFS HTTP HTTPS WebDAV iscsi FC SRP iser FTP SFTP Sun ZFS Storage /. Analytics - ZFS -,, DRAM Sun ZFS Storage. :.. Oracle. "Oracle ("SLA") ". RAID-Z(RAID-5 RAID-6), /, - (7310, 7320, 7410, 7420) 10 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
iscsi LUN NDMP Sun ZFS Storage.. (CPU, DRAM, I/O,,, ) ZFS RAID-6( ) Disk Shelf RAID-6 - (7310, 7320, 7410, 7420) IP Disk Shelf I/O Phone-Home Lights Out BUI( ) BUI.BUI,,. 1 11
Hardware. NET-0 IP ( : https://ipaddress:215 https://hostname:215).. BUI.BUI Help. CLI( ) CLI BUI. CLI. CLI. Tab. Tab. Tab 'Tab'.. help. ( : help commands). help help topics.. dory:> help tab builtins commands general help properties script Hardware 12 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
Hardware Maintenance > Hardware (" " ) Disk Shelf. BUI CLI. BUI BUI Disk Shelf. Sun Storage 7110,.... LED. 1 13
Hardware.. ( ). ( ). ( )., Disk Shelf( )...... Configuration > Services > System Identity. LED,,.. "Show Details",.. 14 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
Hardware Manufacturer Model Serial Processors Memory System Data Cache Log Total........ "-".. Disk Shelf. "-"... "-".. Disk Shelf Disk Shelf( ). Disk Shelf. Disk Shelf... Name Manufacturer Model Data Cache Log Disk Shelf. Disk Shelf,. Disk Shelf. Disk Shelf. Disk Shelf. Drive Shelf ("Readzillas"). Disk Shelf,. Shelf "-". Drive Shelf ("Logzillas"). Shelf "-". 1 15
Hardware Paths Locate Disk Shelf I/O., "2".. Disk Shelf HBA. Disk Shelf,. Disk Shelf LED. LED. ( )., (,,,, ).......,. Disk Slot CPU( ) Memory( ) Fan Power supply (PSU) Service processor (SP)( )...,... 16 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
Hardware Label FMRI Active Problems Manufacturer Model Build Part Serial Revision Size Type Speed Cores GUID.. FMRI( ).,.,........... ( ).. 'system', 'data', 'log', 'cache', 'spare'. 'spare'. (GB). CPU... Locate. LED. 1 17
Hardware Offline Online. ( )..,. ( : )..... Infiniband Infiniband (HCA). State "active". ("down", "init", "arm").. GUID Speed GUID., Single Data Rate (SDR), Dual Data Rate (DDR), Quad Data Rate (QDR).... MAC Address IP Address Source IP Address Subnet MAC.. 'DHCP' 'Static'. DHCP. IPv4 ( IP ). IPv6. ( IP ). 18 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
Hardware Default Gateway IPv4. ( :DHCP IP ). CLI CLI maintenance hardware. show. list, show. tarpon:> maintenance hardware show Chassis: NAME STATE MANUFACTURER MODEL chassis-000 0839QCJ01A ok Sun Microsystems, Inc. Sun Storage 7410 cpu-000 CPU 0 ok AMD Quad-Core AMD Op cpu-001 CPU 1 ok AMD Quad-Core AMD Op cpu-002 CPU 2 ok AMD Quad-Core AMD Op cpu-003 CPU 3 ok AMD Quad-Core AMD Op disk-000 HDD 0 ok STEC MACH8 IOPS disk-001 HDD 1 ok STEC MACH8 IOPS disk-002 HDD 2 absent - - disk-003 HDD 3 absent - - disk-004 HDD 4 absent - - disk-005 HDD 5 absent - - disk-006 HDD 6 ok HITACHI HTE5450SASUN500G disk-007 HDD 7 ok HITACHI HTE5450SASUN500G fan-000 FT 0 ok unknown ASY,FAN,BOARD,H2 fan-001 FT 0 FM 0 ok Sun Microsystems, Inc. 541-2068 fan-002 FT 0 FM 1 ok Sun Microsystems, Inc. 541-2068 fan-003 FT 0 FM 2 ok Sun Microsystems, Inc. 541-2068 fan-004 FT 1 ok unknown ASY,FAN,BOARD,H2 fan-005 FT 1 FM 0 ok Sun Microsystems, Inc. 541-2068 fan-006 FT 1 FM 1 ok Sun Microsystems, Inc. 541-2068 fan-007 FT 1 FM 2 ok Sun Microsystems, Inc. 541-2068 memory-000 DIMM 0/0 ok HYNIX 4096MB DDR-II 66 memory-001 DIMM 0/1 ok HYNIX 4096MB DDR-II 66... ("SERIAL") 5.. BUI.. 1 19
Hardware CLI build cores device faulted label locate (writable) manufacturer model offline (writeable) part present revision serial size speed type use BUI Build Cores N/A (status indicator) Label (status indicator) Manufacturer Model (status indicator) Part (status indicator) Revision Serial Size Speed (combined with use) detach. CPU "CPU 0". tarpon:maintenance hardware> select chassis-000 tarpon:maintenance chassis-000> select cpu tarpon:maintenance chassis-000 cpu> select cpu-000 tarpon:maintenance chassis-000 cpu-000> show Properties: label = CPU 0 present = true faulted = false manufacturer = AMD model = Quad-Core AMD Opteron(tm) Processor 8356 part = 1002 20 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
Hardware revision = 03 cores = 4 speed = 2.14G BUI 1 2 Maintenance > Hardware. Storage System Disk Shelf. 3 4.. ( ). LED. CLI CLI LED.. hostname:> maintenance hardware. hostname:maintenance hardware> list NAME STATE MODEL SERIAL chassis-000 hostname ok Sun Storage 7410 unknown chassis-001 000000000C faulted J4400 000000000C. hostname:maintenance hardware> select chassis-001 hostname:maintenance chassis-001> list disk fan psu slot. 1 21
Hardware hostname:maintenance chassis-001> select disk hostname:maintenance chassis-001 disk> show Disks: LABEL STATE MANUFACTURER MODEL SERIAL disk-000 HDD 0 ok ST3500630NS ST3500630NS 9QG1ACNJ disk-001 HDD 1 faulted ST3500630NS ST3500630NS 9QG1A77R disk-002 HDD 2 ok ST3500630NS ST3500630NS 9QG1AC3Z disk-003 HDD 3 ok ST3500630NS ST3500630NS 9QG1ACKW disk-004 HDD 4 ok ST3500630NS ST3500630NS 9QG1ACKF disk-005 HDD 5 ok ST3500630NS ST3500630NS 9QG1ACPM disk-006 HDD 6 ok ST3500630NS ST3500630NS 9QG1ACRR disk-007 HDD 7 ok ST3500630NS ST3500630NS 9QG1ACGD disk-008 HDD 8 ok ST3500630NS ST3500630NS 9QG1ACG4 disk-009 HDD 9 ok ST3500630NS ST3500630NS 9QG1ABDZ disk-010 HDD 10 ok ST3500630NS ST3500630NS 9QG1A769 disk-011 HDD 11 ok ST3500630NS ST3500630NS 9QG1AC27 disk-012 HDD 12 ok ST3500630NS ST3500630NS 9QG1AC41 disk-013 HDD 13 ok ST3500630NS ST3500630NS 9QG1ACQ5 disk-014 HDD 14 ok ST3500630NS ST3500630NS 9QG1ACKA disk-015 HDD 15 ok ST3500630NS ST3500630NS 9QG1AC5Y disk-016 HDD 16 ok ST3500630NS ST3500630NS 9QG1ACQ2 disk-017 HDD 17 ok ST3500630NS ST3500630NS 9QG1A76S disk-018 HDD 18 ok ST3500630NS ST3500630NS 9QG1ACDY disk-019 HDD 19 ok ST3500630NS ST3500630NS 9QG1AC3Y disk-020 HDD 20 ok ST3500630NS ST3500630NS 9QG1ACG6 disk-021 HDD 21 ok ST3500630NS ST3500630NS 9QG1AC3X disk-022 HDD 22 ok ST3500630NS ST3500630NS 9QG1ACHL disk-023 HDD 23 ok ST3500630NS ST3500630NS 9QG1ABLW LED. hostname:maintenance chassis-001 disk> select disk-001 hostname:maintenance chassis-001 disk-001> set locate=true locate = true (uncommitted) hostname:maintenance chassis-001 disk-001> commit 22 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
2 2. BUI Hardware Maintenance.BUI Maintenance > Hardware.. -. 23
7120 7120 7320 7420-7x20 -,,,,,. 7110 7210 7310 7410-7x10 -,,,,,. Disk Shelf - Oracle Storage Drive Enclosure DE2-24, Sun Disk Shelf J4400/J4500 Disk Shelf - Disk Shelf. HBA 2 3 HBA 3 4 HBA 4 5 HBA 5 6 -ILOM. -,. -. -. -. -. -. 7120 7120 Sun ZFS Storage 7120.. -. Disk Shelf - Disk Shelf. Sun ZFS Storage 7120 Xeon 2 x64, 2U PCIe 4 24 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7120 DIMM 18. http://www.oracle.com/us/ products/servers-storage/storage/nas/overview/index.html (http://www.oracle.com/ us/products/servers-storage/storage/nas/overview/index.html). Sun ZFS Storage 7120 FC SAN Implementing Fibre Channel SAN Boot with Oracle's Sun ZFS Storage Appliance (http://www.oracle.com/ technetwork/articles/servers-storage-admin/fbsanboot-365291.html (http:// www.oracle.com/ technetwork/articles/servers-storage-admin/fbsanboot-365291.html)). 7120 Disk Shelf, 11 x 300GB 15K, 600GB 15K, 1TB 7.2K, 2TB 7.2K 3TB 7.2K SAS-2 HBA. SAS-2 SAS-1,,. 2U. 87.6mm/3.45 765.25mm/30.13 436.8mm/17.2 29.54kg/65. Logzilla 3.5" SSD 3 Sun Aura HBA Logzilla. 1 LED/ ( ) 7 HDD 2 13 HDD 8 2 25
7120 2 LED( ) 8 HDD SSD 3 14 HDD 9 3 9 HDD 4 15 HDD 10 4 / LED( ) 10 HDD 5 16 HDD 11 5 HDD 0 11 HDD 6 17 6 HDD 1 12 HDD 7. : Sun Dual Port 40Gb/sec 4x Infiniband QDR HCAdapter PCIe (375-3606-01) 1, 2 3. 375-3606-01 HCA 10Gb. 1 1 6 PCIe 4 11 2 0 7 HDD 1 12 NET0,1,2,3 3 PCIe 0 8 HDD 0 13 USB 2.0 (0, 1) 4 PCIe 3 9 LED 14 HD15 5 PCIe 1 10 (SER MGT) RJ-45,SP. 26 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7120 (NET MGT) RJ-45,SP. 10/100/1000 Mbit/ 4 RJ-45 (NET0, NET1, NET2, NET3).. 7120... 110-220v C13 2 : 50/60Hz : 100-120/200-240 VAC AC RMS: 13.8A @ 100 VAC AC : 90-264 VAC 3.3 VDC STBY: 3.0A +12 VDC: 86.7A : 1235.3W : 4212 BTU( ) : 1261 VA @ 240 VAC, 0.98P.F. : FRU( ). PCIe - PCIe.. 2 27
7120 - FRU, CPU, DIMM 18, SP( ).SP ( ).SP 3.3V AC. - FRU, 12V. Break Out. kill.. - FRU,,, I/O. "kill". - FRU,. LED I2C. - FRU,, I/O,, / LED. 12. /,, LED. 28 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7120 I/O 7120 I/O. 1 3 2 4. 2 29
7120 :. 1 HBA PCI-Express. 30 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7120 2. CPU 7120 DDR3 DIMM 18. 48GB, 6x8GB DDR-1333 (LV) DIMMS. 7120 CPU. FRU/CRU F371-4966-01 DIMM, 8GB, DDR3, 2RX4, 13 CRU F371-4885-01 Intel E5620, 2.40G FRU DDR3 DIMM. DDR3 DIMM. DIMM P0 D1, D2, D4, D5, D7, D8. 2 31
7120, LED.. 1 5 32 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7120 2 SAS 6 3 7 4 7120. All PCIe. Aura Logzilla 7120. TA7120-12TB S7120, 1xCPU, 24GB, 12TB 597-0754-01 TA7120-24TB S7120, 1xCPU, 24GB, 24TB 597-0755-01 Logzilla 3.5" SSD 7120. 7101282 S7120, 1xCPU, 24GB, 3.3TB 7014523 7101284 S7120, 1xCPU, 24GB, 6.6TB 7014525 NIC/HBA 7120 NIC/HBA. SG-XPCIESAS-GEN2-Z 2 Sun Thebe SAS (x4) HBA, PCIe 594-5889-01 SG-XPCIE2FC-QF8-Z 2 FC HBA, 8Gb, PCIe 594-5684-01 X4446A-Z 4 PCI-E Quad GigE UTP 594-4024-01 X4237A-N 2 4X IB HCA PCIe 594-5862-02 X1109A-Z 2 10Gig SFP+ NIC, PCIe 594-6039-01 2 33
7320 PCIe 7120 PCIe. Slot Sun 0 PCIe 540-7975-03 Sun Aura HBA Logzilla ( ) 0 PCIe 375-3481-01 Intel EXPI9404PT QP Copper NIC 0 PCIe 375-3617-01 Intel Niantic DP 10GE NIC 0 PCIe 371-4325-01 QLogic 8Gb DP FC HBA FC ( ) 0 PCIe 375-3606-01 Mellanox MHJH29-XTC InfiniBand HCA 1 PCIe 375-3617-01 Intel Niantic DP 10GE NIC 1 PCIe 375-3606-01 Mellanox MHJH29-XTC InfiniBand HCA 1 PCIe 375-3481-01 Intel EXPI9404PT QP Copper NIC 1 PCIe 371-4325-01 QLogic 8Gb DP FC HBA FC ( ) 3 PCIe 375-3665-01 Sun Thebe (INT) SAS HBA 4 PCIe 375-3481-01 Intel EXPI9404PT QP Copper NIC 4 PCIe 371-4325-01 QLogic 8Gb DP FC HBA FC ( ) 4 PCIe 375-3609-03 Sun Thebe (EXT) 8P 6Gb/s SAS HBA 7120 Disk Shelf. 7120 (Logzilla) SSD. Disk Shelf 24 HDD. Shelf. 7320 7320 7320.. -. 34 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7320 Disk Shelf - Disk Shelf. Sun ZFS Storage 7320. 1-6 Disk Shelf. 7320 CPU 2, 4 x 1Gb/s GigE,, NIC,, InfiniBand, SAS HBA. CPU 4 Intel Xeon 5600, 2.40GHz, 80W. 96GB, 6 x 8GB DDR3-1333 (LV) DIMMS(CPU ). CPU 9x 8GB DDR3-1333 LV DIMM(CPU 2 18 x 8GB) 144GB. 7320 24GB( ), 48GB 72GB.. 1-6 Disk Shelf. RAID. 18GB SAS-1 SSD(7320 SAS-2) (LogZilla ) ZIL(ZFS ), Disk Shelf 24 4. 20. http://www.oracle.com/us/products/servers-storage/storage/ unified-storage/index.html (http://www.oracle.com/ us/products/servers-storage/storage/unified-storage/index.html). 7320 HBA, Disk Shelf (1TB 2TB SAS-2) SAS-2(Serial Attached SCSI 2.0). SAS-2 SAS-1,,. 7320. : FRU( ). PCIe - CRU( ) PCIe 3. PCIe. - FRU, CPU, DIMM 18, SP( ).SP ( ).SP 3.3V AC. 2 35
7320 - FRU, 12V.. kill. - FRU,,, I/O. - FRU,. LED I2C. - FRU,, I/O,, / LED. 8. /,, ( ) LED. 7320. FRU/CRU F541-2883-01 X8 PCIe 1U CRU F541-2885-01 X16 PCIe 1U CRU F541-4081-01 RoHS FRU F511-1489-01 DB, FRU F511-1548-01 PCB, 8 1U FRU F541-4275-02 PCBA,, 1U FRU 7320. FRU/CRU F530-4228-01, SAS FRU( ) F530-3927-01 FRU,CBL,PDB,MB,1U+2U,RIBBON FRU( ) F530-4431-01, FRU( ) F530-4417-01 FRU, FRU( ) F530-3880-01,,,, RJ45-RJ45, 6m CRU( ) F530-3883-01 FRU,2M,4X SAS CRU( ) 36 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7320 7320 I/O I/O. 1 2 3 4 SSD(Solid State Disk) 5 /USB 6 7320 CPU 7320 CPU. FRU/CRU F371-4966-01 DIMM, 8GB, DDR3, 2RX4, 13 CRU F371-4885-01 Intel E5620, 2.40G FRU 2 37
7320 DDR3 DIMM 18. DDR3 DIMM. 7320 /. 1 4 / 2 5 3 38 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7320 7320. :.. 110-220v C13 2 : 50/60Hz : 100-120/200-240 VAC AC RMS: 9.0 amps( ) AC : 90-264 VAC 3.3 VDC STBY: 3.6A +12 VDC: 62.3A : 873W : 2977 BTU( ) : 891 VA @ 240 VAC, 0.98P.F 7320 LED. 1 /LED 2 ( ) 3 / LED( ) 2 39
7320 4 5 6 LED 7 7320. HDD( ) 0 1. 4 (ReadZilla SSD) 2-5. 6 7. HDD1 HDD3 HDD5 HDD0 HDD2 HDD4 HDD6 HDD7 7320 7320,.,. FRU/CRU F300-2233-02 RoHS 760W CRU F541-2075-04, 1U FRU F542-0184-01 DR, 3Gb SATA CRU F542-0330-01 2.5" 512GB ReadZilla SSD CRU F541-276-01 ASSY, CRU F541-4274-02 (1U) FRU 40 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7320 7320 PCIe 7320 PCIe. FRU/CRU F371-4325-01 8Gb FC HBA(PCIe) CRU F375-3609-02 PCA, SAS 6GBS 8 (PCIe) CRU F375-3606-03 (x4) IB HCA(PCIe) CRU F375-3696-01 CX2 4XQDR(PCIe) CRU F375-3617-01 2X10GbE SFP+, X8(PCIe) CRU F375-3481-01 NIC 1GigE Cu(PCIe) CRU F511-1496-04 Sun Fishworks Cluster Controller 200(PCIe) FRU 7320 7320. Sun 375-3609 2,,. 1 4 2 SC LED 5 3 6 PCIe 7320 96GB RAM, 2x2.4GHz, SAS HBA 1, 10/100/1000 4. 7320. 2 41
7320 TA7320-24A S7320, 2xCPU, 24GB, 597-1060-01 7104054 S7320, 2xCPU, 96GB, 7045900 TA7320-24A-HA S7320, 2xCPU, 24GB, 597-1061-01 7104055 S7320, 2xCPU, 96GB, 7045903 PCIe. All PCIe. Slot 0 PCIe 375-3617-01 Intel Niantic DP 10GE NIC 0 PCIe 375-3696-01 Mellanox InfiniBand HCA 0 PCIe 375-3606-03 MHJH29-XTC InfiniBand HCA 0 PCIe 375-3481-01 Intel EXPI9404PT QP Copper NIC 0 PCIe 371-4325-01 QLogic 8Gb DP FC HBA FC ( ) 1 PCIe 375-3617-01 Intel Niantic DP 10GE NIC 1 PCIe 375-3696-01 Mellanox InfiniBand HCA 1 PCIe 375-3606-03 MHJH29-XTC InfiniBand HCA 1 PCIe 375-3481-01 Intel EXPI9404PT QP Copper NIC 1 PCIe 371-4325-01 QLogic 8Gb DP FC HBA FC ( ) 2 PCIe 375-3609-03 Sun Thebe SAS HBA 7320 7320 96GB RAM, 2x2.4GHz, SAS HBA 1, 10/100/1000 4,. Sun Storage 7420C (XOPT 594-4680-01) 7320 7420.. : 7320,, NIC/HBA. 42 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7320 Slot 0 PCIe 375-3617-01 Intel Niantic DP 10GE NIC 0 PCIe 375-3696-01 Mellanox InfiniBand HCA 0 PCIe 375-3606-03 MHJH29-XTC InfiniBand HCA 0 PCIe 375-3481-01 Intel EXPI9404PT QP Copper NIC 0 PCIe 371-4325-01 QLogic 8Gb DP FC HBA FC ( ) 1 PCIe 542-0298-01 Sun Fishworks 2 2 PCIe 375-3609-03 Sun Thebe SAS HBA 7320 (SERIAL MGT) RJ-45,SP. (NET MGT) RJ-45,SP. 10/100/1000 Mbit/ 4 RJ-45 (NET0, NET1, NET2, NET3).. 7320 Storage Disk Shelf 7320 1-6 Disk Shelf. Shelf Logzilla Shelf.. Shelf. Disk Shelf Disk Shelf 2 43
7420 7420 7420 7420.. -. Disk Shelf - Disk Shelf. Sun ZFS Storage 7420 Appliance 1-36 Disk Shelf. http://www.oracle.com/us/products/servers-storage/storage/unified-storage/ index.html (http://www.oracle.com/ us/products/servers-storage/storage/unified-storage/index.html). 3U. 13.3cm/5.25 70.6cm/27.8 43.7cm/17.19 16.36kg/96 1 LED ( ) 7 PS( ) LED 13 SSD(Solid State Disk) 2() 44 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7420 2 ( ) 8 LED 14 SSD(Solid State Disk) 3() 3 / LED( ) 9 USB 2.0 15 SSD(Solid State Disk) 4() 4 10 DB-15 16 SSD(Solid State Disk) 5() 5 SP( ) LED( ) 6 /CPU/ LED 11 0 12 1( ) 500GB (HDD) 0 1, Sun Storage Readzilla 512GB SSD(Solid State Drive) 2-5. 0, 2, 3 4 Readzilla. 1 ( ) 2 ( ) 3 / ( ) 7420. HBA. 2 45
7420 1 0( LED :, :,AC : ) 8 (NET) 10/100/1000 : NET0-NET3 2 0AC 9 USB 2.0 3 1( LED :, :,AC : ) 10 PCIe 5-9 4 1AC 11 (NET MGT) 5 LED( :, :, : ) 12 (SER MGT) 6 PCIe 0-4 13 DB-15 7 7420. FRU( ). - FRU, CPU, DIMM 8, SP( ).SP ( ).SP 3.3V AC. - FRU, 12V. PDB. ("kill").,. 46 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7420 PDB - FRU,,, I/O. - 0 1. - FRU,. LED I2C. -6 FRU,, I/O,, / LED. /,, LED.. 1 7 CPU 2 PCIe 8 3 9 4 10 5 11 SSD 2 47
7420 6 CPU 7420 2 4 CPU, CPU. 4 8 4GB 8GB DDR3 DIMM, CPU 2 256GB CPU 4 512GB. CPU. 7420 CPU, 7420 (1.86GHz 2.00GHz CPU). 7420. 2,4 8 8GB DDR3 DIMM, 2.0Ghz CPU 128GB, 256GB 512GB. 4 8 8GB DDR3 DIMM, 2.0GHz 2.4Ghz CPU 256GB 512GB. 4 8 16GB DDR3 DIMM, 2.4Ghz CPU 512GB 1TB. 48 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7420 DIMM. D0, D2, D4, D6, D1, D3, D5, D7. DIMM. Maintenance > Hardware DIMM /SYS/MB/P0/D7. LED. LED. 2 49
7420 LED (TOP) LED LED LED. PCIe Sun Fishworks Cluster Controller 200 (C). SAS HBA 1 8. SAS HBA 2, SAS HBA 7. PCIe 9( ), 0( ), 7, 2, 6, 3, 5, 4. (SER MGT) RJ-45,SP. (NET MGT) RJ-45,SP LAN. 10/100/1000 Mbit/ 4 RJ-45 (NET0, NET1, NET2, NET3).. 7420 7420 7420. All PCIe. 7420. : 7100566 7100568. TA7420-26A S7420, DIMM, 2x1.86GHz-6C 597-0789-01 TA7420-28A S7420, DIMM, 2x2.00GHz-8C 597-0790-01 50 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7420 7420. TA7420-26AR00HA S7420, DIMM, 2x1.86GHz-6C, 597-0795-01 TC7420-28AR00HA S7420, DIMM, 2x2.00GHz-8C, 597-0792-01 7100566 S7420, DIMM, 4x2GHz-8C, 7014572 7100568 S7420, DIMM, 4x2.40GHz-10C, 7014573 NIC/HBA 7420 NIC/HBA. SG-XPCIESAS-GEN2-Z 2 Sun Thebe SAS (x4) HBA, PCIe F375-3609-03 SG-XPCIE2FC-QF8-Z 2 FC HBA, 8Gb, PCIe 594-5684-01 X4446A-Z 4-port PCIe Quad GigE UTP 594-4024-01 X4242A 2 CX2 4xQDR, HCA PCIe 594-6776-01 X4237A 2 4X IB HCA PCIe 594-5862-02 X1109A-Z 2 10Gig SFP+ NIC, PCIe 594-6039-01 X2129A XCVRm 850NM, 1/10GPS, Short Reach, SFP 594-6508-01 X5562A-Z XCVR 1300NM, 1/10GPS, Long Reach, SFP 594-6689-01 PCIe 7420 PCIe. 7420 6 10Gb NIC, 8Gb FC HBA, Gb NIC 4 InfiniBand HCA. Slot Sun 0 PCIe 371-4325-01 8Gb DP FC HBA 6 FC ( ) 1 PCIe 375-3609-02 DP SAS-2 HBA 6 ( 2) 2 PCIe 375-3609-02 DP SAS-2 HBA 6 2 51
7420 Slot Sun 2 PCIe 375-3481-01 QP Copper NIC 6 2 PCIe 371-4325-01 8Gb DP FC HBA 6 FC ( ) 2 PCIe 375-3606-01 Infiniband HCA 4 2 PCIe 375-3617-01 DP 10GE NIC 6 2 PCIe 375-3696-01 CX2 Infiniband HCA 4 3 PCIe 375-3609-02 DP SAS-2 HBA 6 3 PCIe 375-3481-01 QP Copper NIC 6 3 PCIe 371-4325-01 8Gb DP FC HBA 6 FC ( ) 3 PCIe 375-3606-01 Infiniband HCA 4 3 PCIe 375-3617-01 DP 10GE NIC 6 3 PCIe 375-3696-01 CX2 Infiniband HCA 4 4 PCIe 375-3481-01 QP Copper NIC 6 4 PCIe 375-3606-01 InfiniBand HCA 4 4 PCIe 375-3617-01 DP 10GE NIC 6 4 PCIe 371-4325-01 8Gb DP FC HBA 6 FC ( ) 4 PCIe 375-3696-01 CX2 Infiniband HCA C PCIe 511-1496-04 200 4 1 5 PCIe 375-3481-01 QP Copper NIC 6 5 PCIe 375-3606-01 InfiniBand HCA 4 5 PCIe 375-3617-01 DP 10GE NIC 6 5 PCIe 371-4325-01 8Gb DP FC HBA 6 FC ( ) 6 PCIe 375-3609-02 DP SAS-2 HBA 6 6 PCIe 375-3481-01 QP Copper NIC 6 6 PCIe 371-4325-01 8Gb DP FC HBA 6 FC ( ) 6 PCIe 375-3606-01 InfiniBand HCA 4 52 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7x20 Slot Sun 6 PCIe 375-3617-01 DP 10GE NIC 6 6 PCIe 375-3696-01 CX2 Infiniband HCA 4 7 PCIe 375-3609-02 DP SAS-2 HBA 6 7 PCIe 375-3481-01 QP Copper NIC 6 7 PCIe 371-4325-01 8Gb DP FC HBA 6 FC ( ) 7 PCIe 375-3606-01 Infiniband HCA 4 7 PCIe 375-3617-01 DP 10GE NIC 6 7 PCIe 375-3696-01 CX2 Infiniband HCA 4 8 PCIe 375-3609-02 DP SAS-2 HBA 6 ( 2) 9 PCIe 371-4325-01 8Gb DP FC HBA 6 FC ( ) 7420 Shelf. Disk Shelf 7420 1-6 Disk Shelf 1-6. Shelf Logzilla Shelf.. Shelf. Disk Shelf. 7x20 7x20 CRU Oracle Sun ZFS Storage 7120, 7320, 7420 CRU( ). Shelf Disk Shelf. 2 53
7x20 7120 7320 7420...,.... Important Safety Information for Sun Hardware Systems,... PCI, HDD, SSD, (ESD). HDD..,. CRU. -HDD PCI... -. 2 Phillips 1 ( ) 54 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7x20... BUI Sun. hostname: maintenance hardware show 7x20 HDD SSD 1. BUI Maintenance > Hardware HDD SSD. HDD SSD. 2.. 3. HDD SSD. 4. (2). 5. 15 Hardware > Maintenance. 2 55
7x20 6.. 7.. Sun ZFS Storage. Drive Shelf BUI Maintenance > Hardware.,. :.. 7120 7320: 7120 7320. 7120 7320,. 7320. 60. 7420: 7420. 56 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7x20 1. BUI Maintenance > Hardware, SP( ) set /SYS/LOCATE status=on. LED. 2.. 3.. 4.. 5. 7120 7320:.. BUI Maintenance > Hardware.. 2 57
7x20. : 1..,.. 6. 7420:. BUI Maintenance > Hardware... 58 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7x20 7420..,. 7., /. 8.... LED. 1.. 2 59
7x20 2. CMA( ) CMA. 3.. 4.. 7120 7320:. 7120 7320,. 7320. 7420:. 5.. 60 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7x20 6.. 7420. 7.. 8. AC. 9. CMA CMA. 10. BUI Maintenance > Hardware. ( ). Memory LED. BUI Maintenance > Hardware. DIMM. :,...,.. BUI. SSH maintenance system poweroff. SSH SP( ) stop /SYS.. / 4. 2 61
7x20 1. AC. 2.. 3.. 4.. 5. 7120 7320: 7120 7320,. 7320... 1.3cm(1/2 )... 6. 7420:. 62 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7x20.. 7. DIMM. 7120. 2 63
7x20 7420. 8. 7420: DIMM.. 9. DIMM DIMM. 64 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7x20 10. DIMM. 11. DIMM. 12. 7120 7320: 7120 7320,. 7320.. 2.5cm(1 ).... 13. 7420:. 2 65
7x20 CPU. 2.5cm(1 ).. 66 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7x20 14.. 7420. 15.. 16.., / 2. 17.. /.BUI Maintenance > Hardware DIMM Details. 2 67
7x20 PCIe BUI Maintenance > Hardware Slots. :,.. 7120 Sun Flash Accelerator F20 FRU Oracle. HBA. HBA..,.. BUI. SSH maintenance system poweroff. SSH SP( ) stop /SYS.. / 4. 1. AC. 2.. 3.. 4.. 5. 7120 7320:.. 1.3cm(1/2 ).. 6. 7420:. 68 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7x20.. 7. PCIe. (7320 ), 7120 7420. 8. 7120 7320: PCIe. PCIe.... 2 69
7x20. PCIe. PCIe. PCIe... 70 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7x20 PCI PCIe. 9. 7420: PCIe. PCIe. PCIe. PCIe. PCIe PCIe. PCIe.. 2 71
7x20 10. 7120 7320: 7120 7320,. 7320.. 2.5cm(1 )... 11. 7420:. 2.5cm(1 ) (1). (2). 72 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7x20. 12.,. 13.. 14.., / 2. 15.. /. 16. PCIe. 17. BUI Maintenance > Hardware. Slots. ( ). 18. Disk Shelf. 2 73
7x20. (1 )..,.. BUI. SSH maintenance system poweroff. SSH stop /SYS.. / 4. 1. AC. 2.. 3.. 4.. 5. 7120 7320:.. 1.3cm(1/2 ).. 6. 7420:. 74 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7x20. 7.. 8.. 7420. 2 75
7x20 7120. 9. (+). 10. 7120 7320: 7120 7320,. 7320.. 2.5cm(1 )... 11. 7420:. 2.5cm(1 ) (1). (2). 76 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
7x20. 12.,. 13.. 14.., / 2. 15.. /. 16. PCIe. 17. BUI. 2 77
Shelf Shelf Disk Shelf Oracle Disk Shelf SAS( SCSI).,, IOM(I/O ) SIM(SAS ).. Disk Shelf BUI Maintenance > Hardware. Disk Shelf Disk Shelf. J4500 http://download.oracle.com/docs/cd/e19122-01/j4500.array/index.html (http://download.oracle.com/docs/cd/e19122-01/j4500.array/index.html.). Oracle Storage Drive Enclosure DE2-24P Oracle Storage Drive Enclosure DE2-24P 24 2.5" SAS-2 2U. HDD, SSD. Disk Shelf IOM(I/O ). Oracle Storage Drive Enclosure DE2-24C 78 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
Shelf Oracle Storage Drive Enclosure DE2-24C 24 3.5" SAS-2 4U. SSD, HDD. Disk Shelf IOM(I/O ). Sun Disk Shelf 24x3.5" SAS-2 Sun Disk Shelf 24 3.5" SAS-2 4U. SSD, HDD. Disk Shelf SIM(SAS ). Sun Storage J4400 Array 2 79
Shelf Sun Storage J4400 Array 24 3.5" SAS-1 SATA II 4U. SIM(SAS ). Sun Storage J4500 Array Sun Storage J4500 Array 48 3.5" SATA II 4U. SAS,. SAS-1 Sun Storage J4400 Array SAS-1( SCSI 1.0). SAS-2 SAS-2( SCSI 2.0),,. 864 36 Shelf SAS-2 80 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
Shelf. SAS-2 HBA Sun ZFS Storage 7000 1024. Shelf.. SAS-2 Shelf. Oracle Storage Drive Enclosure DE2-24P Oracle Storage Drive Enclosure DE2-24C Sun Disk Shelf.. Oracle Storage Drive Enclosure DE2-24P Disk Shelf 4 Logzilla SSD. Logzilla SSD 20, 21, 22, 23. Oracle Storage Drive Enclosure DE2-24C, Sun Disk Shelf J4400 2 81
Shelf Disk Shelf 4 Logzilla SSD. Logzilla SSD 20, 21, 22, 23., J4400 SSD 8, 4, 16, 20. Oracle Storage Drive Enclosure DE2-24C.. Oracle Storage Drive Enclosure DE2-24P 1 4 2 5 / 3 Oracle Storage Drive Enclosure DE2-24C 82 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
Shelf 1 4 / 2 5 3 Sun Disk Shelf 2 83
Shelf 1 4 7 2 5 8 SIM 3 6 9 Sun Storage J4400 Array 1 2 84 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
Shelf IOM(I/O ) SIM. Oracle Storage Drive Enclosure DE2-24P 1 0 3 I/O 0 2 I/O 1 4 1 Oracle Storage Drive Enclosure DE2-24C 2 85
Shelf 1, 0 4, 3 7 I/O 2 1 5 I/O 8 I/O 1 3 2 6 I/O 0 :. Sun Disk Shelf Sun Storage J4400 Array 86 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
Shelf 1. 0 1. 2 SIM(SAS ). SIM 0 SIM 1. I/O IOM(I/O ) Disk Shelf. Oracle Storage Drive Enclosure DE2-24P Oracle Storage Drive Enclosure DE2-24C 2 87
Shelf 1 / 4 SAS-2 1 7 Oracle 2 / 5 SAS-2 2 8 Oracle 3 SAS-2 0 6 SIM SIM Disk Shelf. Sun Disk Shelf Sun Storage J4400 Array Sun Storage J4500 Array Sun Disk Shelf SIM. 88 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
Shelf 1 AC 6 2 DC 7 3 8 4 9 SIM ( )/SIM ( ) 5 10 SIM Sun Storage J4400 Array Sun Storage J4500 Array SIM. 2 89
Shelf 1 SIM 2 SIM 3 SIM 4 SIM 5 SIM / LED Disk Shelf. Oracle Storage Drive Enclosure DE2-24P Oracle Storage Drive Enclosure DE2-24C 1 DC 6 2 7 3 AC 4 5 / Disk Shelf. Sun Disk Shelf 90 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
Shelf Sun Storage J4400 Array Sun Storage J4500 Array 1 6 2 AC 7 3 DC 8 4 5 / Disk Shelf Shelf. 2 91
Shelf Oracle Storage Drive Enclosure DE2-24P 7103910 Drive Enclosure DE2-24P Disk Shelf 7103911 300GB 10Krpm, SAS-2, 2.5" HDD 7103912 900GB 10Krpm, SAS-2, 2.5" HDD 7103915 73GB SSD SAS-2, 2.5" 7103917, Drive Enclosure DE2-24P Oracle Storage Drive Enclosure DE2-24C 7103914 Drive Enclosure DE2-24C Disk Shelf 7103913 3TB 7.2Krpm, SAS-2, 3.5" HDD 7103916 73GB SSD XATO SAS-2, 2.5"(2.5" - 3.5" ) 7103918, Drive Enclosure DE2-24C Sun Disk Shelf(DS2) DS2-0BASE DS2-HD2T Sun Disk Shelf(DS2) 24x3.5" SAS-2 2TB 7.2Krpm, SAS-2, 3.5" HDD 7101765 3TB 7.2Krpm, SAS-2, 3.5" HDD 7101274 300GB 15Krpm, SAS-2, 3.5" HDD 7101276 600GB 15Krpm, SAS-2, 3.5" HDD 7101197 73GB SSD XATO, 3.5" DS2-LOGFILLER DS2-4URK-19U Sun Disk Shelf(DS2) 24x3.5", LOGFiller Disk Shelf 92 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
Shelf Sun Storage J4400 Array XTA4400R00A2N12000 XTA4400R00A2N24000 XTA4400A2N11SA18 XTA4400A2N10SA36 XTA4400A2N23SA18 XTA4400A2N22SA36 XTA4400A2N20SA72 Sun Storage J4400, 12xHDD Sun Storage J4400, 24HDD Sun Storage J4400, 11xHDD, 1xSSD Sun Storage J4400, 10xHDD, 2xSSD Sun Storage J4400, 23xHDD, 1xSSD Sun Storage J4400, 22xHDD, 2xSSD Sun Storage J4400, 20xHDD, 4xSSD Sun Storage J4500 Array XTA4500R00A1A24TB XTA4500R00A1N48TB 48x500/7K SATA HDD,1xI/O 48x1TB/7K SATA HDD,1xI/O Shelf Disk Shelf Sun ZFS Storage 7000 Disk Shelf CRU( ). Disk Shelf.. 7120 7320 7420-7110 7210 7310 7410 -. 2 93
Shelf Important Safety Information for Sun Hardware Systems(http://docs.oracle.com/cd/E19446-01/ (http://docs.oracle.com/cd/e19446-01/ )),.,. CRU. CRU. CRU. CRU. CRU. CRU. CRU ( ). Disk Shelf Disk Shelf.. Disk Shelf. Disk Shelf Disk Shelf SAS Shelf NSPF( ). Shelf. NSPF. 1. Disk Shelf Disk Shelf. 2. 2. 3. on/off "O". 4.. : Disk Shelf. 94 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
Shelf Shelf Shelf Shelf... LED.BUI Maintenance > Hardware Disk Shelf, LED. :. Disk Shelf. 1 2.. 2 95
Shelf 3. 4 5.. 96 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
Shelf 6. 7 8., ( ). LED. BUI Maintenance > Hardware Disk Shelf Disk ( ). 2 97
Shelf Disk Shelf. CRU( )., Disk Shelf.. LED.. LED BUI.BUI Maintenance > Hardware Disk Shelf PSU Fan. LED. :. Disk Shelf. 1 2 3. / "O".. 98 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
Shelf 4 /. Oracle Storage Drive Enclosure DE2-24P DE2-24C:. Sun Disk Shelf / J4500 / J4400:. 5. 2 99
Shelf 6 7 /. /. /. Oracle Storage Drive Enclosure DE2-24P DE2-24C:. Sun Disk Shelf / J4500 / J4400:. 8 / "O". 100 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
Shelf 9 10 11. / "I". / LED. BUI Maintenance > Hardware Disk Shelf. PSU Fan ( ). I/O IOM(I/O ) Disk Shelf. Oracle Storage Drive Enclosure DE2-24P Oracle Storage Drive Enclosure DE2-24C IOM(I/O ) SIM,. I/O LED. BUI Maintenance > Hardware Disk Shelf Slot, LED. :. Disk Shelf. 1 2 3 Disk Shelf I/O. I/O.. 4 5 I/O. I/O I/O Disk Shelf. 2 101
Shelf 6 7 8 9.. I/O 60. LED / LED. SAS-2 4 LED. BUI Maintenance > Hardware Disk Shelf Slot I/O I/O ( ). SIM SIM Disk Shelf. Sun Disk Shelf Sun Storage J4500 Array Sun Storage J4400 Array SIM I/O,. SIM, SIM SIM. SIM LED.BUI Maintenance > Hardware Disk Shelf Slot, LED. :. Disk Shelf. 1 2 3 4 SIM.. SAS.... ( : ).. 2. 102 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
Shelf 5 SIM. 6 SIM. 2 103
Shelf 7 SIM. 8 9 10 11 12 SIM.. SAS. SIM 60. LED SIM LED. BUI Maintenance > Hardware Disk Shelf Slot SIM SIM ( ). 104 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
SP( ). CPU. ILOM. ILOM. ILOM ILOM( ) BUI. ILOM. ILOM (i) (ii).ilom. :ILOM. NIC.BUI Allow Admin 215 BUI ssh 22 CLI. NIC. NIC. nodea nge0 nodeb nge1,. BUI Configuration -> Cluster.. BUI CLI... :. 2 105
HBA 1 ILOM CPU ILOM CLI.. -> show /SP/faultmgmt. SP/faultmgmt Targets: 0 (/SYS/MB/P0) Properties: Commands: cd show CPU. -> set /SYS/MB/Pn clear_fault_action=true CP0. -> set /SYS/MB/P0 clear_fault_action=true Are you sure you want to clear /SYS/MB/P0 (y/n)? y HBA 1 HBA 2 3 HBA 2 3. PCI. : HBA. PCIe. 106 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
HBA 1 1 HBA 2 Disk Shelf 2 PCI HBA. Disk Shelf Shelf. 2 107
HBA 1 3. 4.. 108 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
HBA 1 5 PCI HBA. 6. 2 109
HBA 2 7.. HBA 2 8 HBA 3 Disk Shelf HBA 3 4 HBA 3 4. PCI. 110 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
HBA 2 : HBA. PCIe. 1 HBA 3 Disk Shelf 2 111
HBA 2 2 PCI HBA. Disk Shelf Shelf. 3. 112 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
HBA 2 4.. 5 PCI HBA. 2 113
HBA 2 6. 7.. 114 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
HBA 3 8 HBA 4 Disk Shelf HBA 3 HBA 4 5 HBA 4 5. PCI. : HBA. PCIe. 1 HBA 4 Disk Shelf 2 115
HBA 3 2 PCI HBA. Disk Shelf Shelf. 3 PCI HBA. 116 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
HBA 3 4.. 5 PCI HBA. 2 117
HBA 3 6. 7.. 118 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
HBA 4 8 HBA 5 Disk Shelf HBA 4 HBA 5 6 HBA 5 6. PCI. : HBA. PCIe. 2 119
HBA 4 1 HBA 5 Disk Shelf 2 PCI HBA. Disk Shelf Shelf. 120 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
HBA 4 3 PCI HBA. 4.. 2 121
HBA 4 5 PCI HBA. 6. 122 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
HBA 4 7.. 8 HBA 6 Disk Shelf 2 123
124
3 3 System Maintenance > System...BUI, CLI. : tarpon:> maintenance system disks show Properties: profile = mirror root = 1.14G var = 52.4M update = 2.52M stash = 14.8M dump = 16.0G cores = 18K unknown = 39.0G free = 401G 125
System Disks: DISK LABEL STATE disk-000 HDD 7 healthy disk-001 HDD 6 healthy : GUI "disk".. Phone Home. Maintenance > System. Oracle Support (http://support.oracle.com (http://support.oracle.com)). Phone Home... BUI Maintenance > System Support Bundles.......... 126 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
System CLI sendbundle. loader:> maintenance system loader:maintenance system> sendbundle A support bundle is being created and sent to Oracle. You will receive an alert when the bundle has finished uploading. Please save the following filename, as Oracle support personnel will need it in order to access the bundle: /cores/ak.9a4c3d7b-50c5-6eb9-c2a6-ec9808ae1cd8.tar.gz. maintenance system bundles. loader:maintenance system> bundles loader:maintenance system bundles> list BUNDLE STATUS PROGRESS /cores/ak.9a4c3d7b-50c5-6eb9-c2a6-ec9808ae1cd8.tar.gz Uploading 7% loader:maintenance system bundles> ak.. destroy. select list. loader:maintenance system bundles> select 9a4c3d7b-50c5-6eb9-c2a6-ec9808ae1cd8 loader:maintenance system bundles 9a4c3d7b-50c5-6eb9-c2a6-ec9808ae1cd8> list Properties: filename = /cores/ak.9a4c3d7b-50c5-6eb9-c2a6-ec9808ae1cd8.tar.gz status = uploading step_progress = 14.709744730821669 14%. retry cancel... ( ).. BUI: Maintenance > System "INITIAL SETUP". CLI: maintenance system setup. 3 127
.. ( )... BUI: Maintenance > System "FACTORY RESET". CLI: maintenance system factoryreset. GRUB: kernel GRUB -c. :..,.. ( :HBA ),.. Oracle Support. ( : ak-nas-2010-02-09-1-0.pkg.gz)..,. 128 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
,. BUI CLI..... ( : )BUI CLI........( ).. 30...,... :. ( ).. Sun Storage 7410. BUI CLI.... 3 129
. Configuration/Storage CLI........,..,. System Ready Yes. :.. BUI BUI. Check Unchecked.. 130 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
System Ready Yes No Alert Log. CLI CLI maintenance system updates upgrade. gill:maintenance system updates> select ak-nas@2011.04.24,1-0 gill:maintenance system updates ak-nas@2011.04.24,1-0> check You have requested to run checks associated with waiting upgrade media. This will execute the same set of checks as will be performed as part of any upgrade attempt to this media, and will highlight conditions that would prevent successful upgrade. No actual upgrade will be attempted, and the checks performed are of static system state and non-invasive. Do you wish to continue? Are you sure? (Y/N) Healthcheck running... / Healthcheck completed. There are no issues at this time which would cause an upgrade to this media to be aborted. 3 131
. ( 1 ).. 7000:> maintenance system updates select ak-nas@2011.04.24.3.0,1-1.19 upgrade This procedure will consume several minutes and requires a system reboot upon successful update, but can be aborted with at any time prior to reboot. A health check will validate system readiness before an update is attempted, and may also be executed independently using the check command. Are you sure? (Y/N) error: System is not in an upgradeable state: prerequisite healthcheck reports problems. See alert log for more. 1. BUI CLI,.,.. ID B1 "System software update cannot proceed: Slot <label> in disk shelf <name> is reported as absent." B2 "System software update cannot proceed: Slot <label> in disk shelf <name> is faulted." SIM. 1,2,4 SIM. 1,2,4 132 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
ID C1 "System software update cannot proceed: Some slots of disk shelf <name> have no firmware revision information." C2 "System software update cannot proceed: The slots of disk shelf <name> have non-uniform part numbers." C5 "System software update cannot proceed: The slots of disk shelf <name> have mixed firmware revisions <rev1> and <rev2>." zero paths>." E2 "System software update cannot proceed: Disk shelf <name> path <pathname> is <state>." log> disk <label> in disk shelf <name> has <just one path zero paths>." PAN1 "Slot <slot> has a Revision B3 SAS HBA; Revision C0 (or later) required." SIM. SIM. SIM. Disk shelf. Disk shelf.. B3 SAS HBA. 1, 4 2, 4 4 1, 2, 4 1, 2, 4 3, 4 4. 1. SAS LED. 2. SIM.2 SIM LED. 3..30 LED. 4. Oracle Support..... 3 133
.. " "....... 'Apply'.,.,.. :... "passthrough-x" aclinherit property 2009.Q2.0.0 User quotas COMSTAR Triple-Parity RAID Dedup Replication Received Properties Slim ZIL Snapshot Deletion Recursive Snapshots Multi Replace 2009.Q3.0.0 2009.Q3.0.0 2009.Q3.0.0 2010.Q1.0.0 2010.Q1.0.0 2010.Q1.0.0 2010.Q3.1.0 2010.Q3.1.0 2010.Q3.1.0 2010.Q3.1.0 RAIDZ Mirror 2011.1.0.0 134 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
Optional Child Directory 2011.1.0.0. GRUB. ( ) ( )..,..,.. GNU GRUB version 0.95 (613K lower / 3537536K upper memory) +-------------------------------------------------------------------------+ Sun Storage 7110 2010.02.09,1-0 Sun Storage 7110 2009.09.01,1-18 +-------------------------------------------------------------------------+ Use the ^ and v keys to select which entry is highlighted. Press enter to boot the selected OS, e to edit the commands before booting, or c for a command-line.. SunOS Release 5.11 Version ak/generic@2010.02.09,1-0 64-bit Copyright 1983-2010 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. System update in progress. Updating from: ak/nas@2009.09.01,1-18 Updating to: ak/nas@2010.02.09,1-0 Updating system datasets... done. Configuring network devices... done. Configuring devices. Sun Storage 7110 Version ak/nas@2010.02.09,1-0 Copyright 2010 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. Reading ZFS config: done. Mounting ZFS filesystems: (27/27) monk console login: 3 135
.,., SAS. Maintenance/System BUI maintenance system updates CLI.,. 2010Q3.4. Firmware Updates.,. Pending, In Progress, Failed. Pending, In Progress. Pending Failed.. Failed (30 ) Pending ( Pending In Progress ).,... ( ),.... Firmware Updates,..,.. 136 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
,.. :.,..,. SAS ( : HBA )... "stalled"..,. Disk Shelf, Shelf., "owner" Disk Shelf.. Maintenance/Hardware Configuration/Storage UI., ( ). Maintenance/Problems. Disk Shelf.. SIM. SIM.. 3 137
.... V V+1 DNS. DNS.,. V V+1,( ). V V-1 V-2 (V-1 " ") V-2 V V-1., V-2 V-1 V. V-1 V.,BUI CLI.. (). BUI CLI,. 10. GNU GRUB version 0.95 (613K lower / 3537536K upper memory) +-------------------------------------------------------------------------+ Sun Storage 7110 2010.02.09,1-0 Sun Storage 7110 2009.09.01,1-18 +-------------------------------------------------------------------------+ Use the ^ and v keys to select which entry is highlighted. Press enter to boot the selected OS, e to edit the commands before booting, or c for a command-line.,.,.. 138 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
SunOS Release 5.11 Version ak/generic@2009.09.01,1-18 64-bit Copyright 1983-2009 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. System rollback in progress. Rollback to: ak/nas@2009.09.01,1-18 Proceed with system rollback [y,n,?] "y",. "n" ( : ).. Sun Storage.. A B. A,B.... :. 1. CLI BUI. 2. B, A. A B.,A. 3. B Configuration/Cluster CLI. A..,. 4. CLI BUI A. Maintenance/System CLI. A. 3 139
5. A. B A. 6.. A B,. A A.( ) B, A. :.. 7. B. Maintenance/System CLI. B. B. 8.. A Configuration/Cluster.. V V+1. A A B B 1,2 CLUSTERED V CLUSTERED V 3 STRIPPED V OWNER V 4 STRIPPED V+1 OWNER V 5,6 OWNER V+1 STRIPPED V 7 OWNER V+1 STRIPPED V+1 8 CLUSTERED V+1 CLUSTERED V+1.. 4 A, 7 B. 6 A A V 4. 140 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
BUI CLI., ("Cluster rejoin mismatch" "Cluster rejoin mismatch on peer" ).. BUI Available Updates... "watch"... 3 141
,.....( )... -,..... 'Apply'.,. CLI CLI upload download. CLI maintenance system updates download. dory:maintenance system updates> download dory:maintenance system updates download (uncommitted)> get url = (unset) user = (unset) password = (unset) 142 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
"url" URL.. URL HTTP("http://" ) FTP("ftp://" ). URL ( : "ftp://myusername:mypasswd@myserver/export/foo"), URL. dory:maintenance system updates download (uncommitted)> set url= ftp://foo/update.pkg.gz url = ftp://foo/update.pkg.gz dory:maintenance system updates download (uncommitted)> set user=bmc user = bmc dory:maintenance system updates download (uncommitted)> set password Enter password: password = ******** dory:maintenance system updates download (uncommitted)> commit Transferred 157M of 484M (32.3%).... dory:maintenance system updates download (uncommitted)> commit Transferred 484M of 484M (100%)... done Unpacking... done dory:maintenance system updates> list UPDATE DATE STATUS ak-nas@2009.10.14,1-0-nd 2009-10-14 08:45 AKUP_WAITING...... help properties. update_. clownfish:maintenance system updates ak-nas@2009.04.03,1-0> help properties Properties that are valid in this context: version date status update_zfs_upgrade => Update media version => Update release date => Update media status => Apply incompatible storage pool update clownfish:maintenance system updates ak-nas@2009.04.03,1-0> get version = 2009.04.03,1-0 date = 2009-4-3 08:45:01 3 143
status = AKUP_WAITING update_zfs_upgrade = deferred clownfish:maintenance system updates ak-nas@2009.04.03,1-0> set update_zfs_upgrade=onreboot update_zfs_upgrade = onreboot clownfish:maintenance system updates ak-nas@2009.04.03,1-0> upgrade. ( ). dory:maintenance system updates> select ak-nas@2009.10.14,1-0-nd dory:maintenance system updates ak-nas@2009.10.14,1-0-nd> upgrade The selected software update requires a system reboot in order to take effect. The system will automatically reboot at the end of the update process. The update will take several minutes. At any time during this process, you can cancel the update with [Control-C]. Are you sure? (Y/N) y Updating from... ak/nas@2009.10.11,1-0 Backing up smf(5)... done. Loading media metadata... done. Selecting alternate product... SUNW,iwashi Installing Sun Storage 7110 2009.10.14,1-0 pkg://sun.com/ak/sunw,iwashi@2009.10.14,1-0:20091014t084500z Creating system/boot/ak-nas-2009.10.14_1-0... done. Creating system/root/ak-nas-2009.10.14_1-0... done..... ^C,. Updating from... ak/nas@2009.10.11,1-0 Backing up smf(5)... done. Loading media metadata... ^C This will cancel the current update. Are you sure? (Y/N) y error: interrupted by user dory:maintenance system updates ak-nas@2009.10.14,1-0-nd> rollback.. -,. destroy. dory:maintenance system updates> destroy ak-nas@2009.10.14,1-0-nd This will destroy the update "ak-nas@2009.10.14,1-0-nd". Are you sure? (Y/N) y dory:maintenance system updates> 144 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
Passthrough x show. apply. clownfish:maintenance system updates> show Updates: UPDATE DATE STATUS ak-nas@2009.11.20.2.1,1-1.9 2009-4-1 04:18:48 AKUP_PREVIOUS ak-nas@2009.04.03,1-0 2009-4-3 08:45:01 AKUP_CURRENT Deferred updates: The following incompatible updates are available. Applying these updates will enable new software features as described below, but will prevent older versions of the software from accessing the underlying resources. You should apply deferred updates once you have verified that the current software update is functioning and a rollback is not required. Applying deferred updates in a cluster will also update any resources on the cluster peer. 1. Support for the "passthrough-x" aclinherit property for shares. clownfish:maintenance system updates> apply Applying deferred updates will prevent rolling back to previous versions of software. Are you sure? (Y/N) clownfish:maintenance system updates> apply Passthrough x Passthrough-x ACL "aclinherit" ( ). "discard", "noallow", "restricted", "passthrough". 2009.Q2.0.0 "passthrough-x". owner, group everyone ACL 'passthrough'. "passthrough" "data". 0664 0666 ACL., ACL. "cc" "gcc" 3 145
COMSTAR. ACL chmod(1)...,. ZFS http://www.opensolaris.org/os/community/zfs/version/14/ (http:// www.opensolaris.org/os/community/zfs/version/14/). 2009.Q3.. ( )... POSIX Windows ID..... COMSTAR COMSTAR PGR(Persistent Group Reservation) ZFS. LUN, 0. 146 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
ZFS 16. 3 RAID 3 RAID 3 RAID RAID-Z.3...,. ZFS 17....,. ZFS 21. 2010.Q1 2009.Q3., 2010.Q1. 3 147
2010.Q1. BUI CLI.... 2010.Q1 ZFS... ZFS 22. Slim ZIL ZFS. ZFS.. ZFS 23. 148 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
. ZFS... ZFS 26. ZFS,. ZFS.,. ZFS 27.,. ZFS. (CR 6782540 ). ZFS 28. 3 149
RAIDZ RAIDZ RAIDZ/. ZFS. ZFS 29.. ZFS.,. ZFS 31.. ( :,,, )..... 150 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
( : NTP, NIS, LDAP ), ( ),,. ( LUN). NDMP, /.. ( :LDAP Active Directory),. ( : LUN,,, ).. SNMP..... -.. - NFS NFS.,. -. DHCP,., 3 151
. CLI., -,..... -.,. -.,,.,.. - ()..... ( ).... ( :LDAP AD)., ID,. 152 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
. ( ).,. BUI BUI Maintenance > System Configuration Backup. "Backup"............ CLI maintenance system configs CLI. 3 153
host:maintenance system configs> list CONFIG DATE SYSTEM VERSION bfa614d7-1db5-655b-cba5-bd0bb0a1efc4 2009-8-5 17:14:28 host 2009.08.04,1-0 cb2f005f-cf2b-608f-90db-fc7a0503db2a 2009-8-24 17:56:53 host 2009.08.18,1-0 backup. done. host:maintenance system configs> backup Backup Configuration. Enter a descriptive comment for this configuration, and click Commit to backup current appliance settings: host:maintenance system configs conf_backup step0> set comment="pre-upgrade" comment = pre-upgrade host:maintenance system configs conf_backup step0> done host:maintenance system configs> restore. UUID( ) ( list ) done.. host:maintenance system configs> restore Restore. Select the configuration to restore: host:maintenance system configs conf_restore step0> set uuid=36756f96-b204-4911-8ed5-fefaf89cad6a uuid = 36756f96-b204-4911-8ed5-fefaf89cad6a host:maintenance system configs conf_restore step0> done : restore. destroy. host:maintenance system configs> destroy cb2f005f-cf2b-608f-90db-fc7a0503db2a Are you sure you want to delete the saved configuration "new"? y host:maintenance system configs> export HTTP FTP HTTP FTP PUT. HTTP FTP.. 154 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
import HTTP FTP HTTP FTP GET. HTTP FTP.. ( ) (, ). Phone Home Oracle Support.,,, Phone Home. BUI. Phone Home 2009-09-16 13:56:36 SMART. 2009-09-05 17:42:55 (, ).. 2009-08-21 16:40:37 ZFS I/O. 2009-07-16 22:03:22. CLI. gefilte:> maintenance problems show Problems: 3 155
COMPONENT DIAGNOSED TYPE DESCRIPTION problem-000 2010-7-27 00:02:49 Major Fault SMART health-monitoring firmware reported that a failure is imminent on disk HDD 17.,, ( ), (). CLI "uuid", "diagnosed", "severity", "type", "status".. Hardware.. ( ) ( )..... Oracle..... BUI. 156 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
ID 2009-9-16 13:01:56 2009-9-16 13:01:51 2009-9-16 13:01:51 f18bbad1-8084-4cab-c950-82ef5b8228ea 'PCIe 0' 'JBOD #1' I/O. 8fb8688c-08f2-c994-a6a5-ac6e755e53bb 'JBOD #1' 'HDD 4'. 446654fc-b898-6da5-e87e-8d23ff12d5d0 'JBOD #1' 'HDD 15'. Event ID.., SNMP,..... BUI. ID 2009-9-5 17:42:35 9e46fc0b-b1a4-4e69-f10f-e7dbe80794fe 'HDD 6'. 2009-9-3 19:20:15 2009-8-21 16:40:48 d37cb5cd-88a8-6408-e82d-c05576c52279. c91c7b32-83ce-6da8-e51e-a553964bbdbczfs I/O. ( : ).. System.,. 3 157
BUI. 2009-10-11 14:13:38 ntpdate. 2009-10-11 14:03:52 genunix ^MSunOS 5.11 ak/generic@2009.10.10,1-0 64 2009-10-11 14:02:04 genunix 2009-10-11 14:02:01 genunix... 2009-10-11 13:52:16 nxge : nxge : ==> nxge_rxdma_databuf_free: DDI BUI CLI. ( ),. BUI. Host 2009-10-12 05:20:24 deimos FTP. 2009-10-12 03:17:05 deimos. 2009-10-11 22:38:56 deimos. 2009-10-11 21:13:35 <console> FTP. Phone Home Phone Home Oracle Support. BUI Phone Home. 2009-10-12 05:24:09 'cores/ak.45e5ddd1-ce92-c16e-b5eb-9cb2a8091f1c.tar.gz' Oracle Support. BUI Maintenance > Logs. 158 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01
CLI CLI maintenance logs. show. caji:> maintenance logs caji:maintenance logs> show Logs: LOG ENTRIES LAST alert 2 2009-10-16 02:44:04 audit 42 2009-10-16 18:19:53 fltlog 2 2009-10-16 02:44:04 scrk 0 - system 100 2009-10-16 03:51:01 CLI 100. show. caji:maintenance logs> select audit show Entries: ENTRY TIME SUMMARY entry-000 2009-10-15 00:59:37 root, <console>, Enabled datalink:nge0 service entry-001 2009-10-15 00:59:39 root, <console>, Enabled interface:nge0 service entry-002 2009-10-15 01:00:39 root, <console>, User logged in entry-003 2009-10-15 01:41:44 root, <console>, Enabled nis service entry-004 2009-10-15 01:42:01 root, <console>, Imported storage pool "pool-0" entry-005 2009-10-15 17:56:30 root, <console>, User logged in entry-006 2009-10-15 17:56:53 root, deimos.sf.fishworks.com, User logged in via CLI entry-007 2009-10-15 18:00:21 root, deimos.sf.fishworks.com, User logged out of CLI entry-008 2009-10-15 18:14:47 root, <console>, Browser session timed out entry-009 2009-10-15 20:46:27 root, deimos.sf.fishworks.com, User logged in via CLI entry-010 2009-10-15 21:51:46 root, <console>, Rebooted appliance entry-011 2009-10-15 21:51:46 root, <console>, User logged out entry-012 2009-10-15 21:56:44 root, deimos.sf.fishworks.com, User logged in via CLI.... show. 3 159
caji:maintenance logs> select audit caji:maintenance logs audit> select entry-000 show Properties: timestamp = 2009-10-15 00:59:37 user = root address = <console> summary = Enabled datalink:nge0 service annotation = "annotation",. 160 Sun ZFS Storage 7120, 7320, 7420 Appliance 2012 12 E39000 01