GDUM-IC-DCAU71(User Manual for Drs Cam)(EngKor)(0).ai

Similar documents
H3050(aap)

사용시 기본적인 주의사항 경고 : 전기 기구를 사용할 때는 다음의 기본적인 주의 사항을 반드시 유의하여야 합니다..제품을 사용하기 전에 반드시 사용법을 정독하십시오. 2.물과 가까운 곳, 욕실이나 부엌 그리고 수영장 같은 곳에서 제품을 사용하지 마십시오. 3.이 제품은

- 이 문서는 삼성전자의 기술 자산으로 승인자만이 사용할 수 있습니다 Part Picture Description 5. R emove the memory by pushing the fixed-tap out and Remove the WLAN Antenna. 6. INS

PowerChute Personal Edition v3.1.0 에이전트 사용 설명서

#KM560

6. Separate HDD by pulling in the arrow direction. * Cautions Avoid lifting HDD excessively, because Connector can be damaged ODD Remove

#KM-235(110222)

untitled

Microsoft Word - USB복사기.doc

#KM-340BL

RVC Robot Vaccum Cleaner

CD-RW_Advanced.PDF

1. Features IR-Compact non-contact infrared thermometer measures the infrared wavelength emitted from the target spot and converts it to standard curr

¹Ìµå¹Ì3Â÷Àμâ

LCD Display

ez-md+_manual01

DE1-SoC Board

(specifications) 3 ~ 10 (introduction) 11 (storage bin) 11 (legs) 11 (important operating requirements) 11 (location selection) 12 (storage bin) 12 (i

ez-shv manual

(Table of Contents) 2 (Specifications) 3 ~ 10 (Introduction) 11 (Storage Bins) 11 (Legs) 11 (Important Operating Requirements) 11 (Location Selection)

대경테크종합카탈로그

00 SPH-V6900_....

K7VT2_QIG_v3

ORANGE FOR ORACLE V4.0 INSTALLATION GUIDE (Online Upgrade) ORANGE CONFIGURATION ADMIN O

#DPK5(PB)(9.8.19)

DDX4038BT DDX4038BTM DDX4038 DDX4038M 2010 Kenwood Corporation All Rights Reserved. LVT A (MN)

KM-380BL,BLB(100908)

K7_Korean

목차 제 1 장 inexio Touch Driver소개 소개 및 주요 기능 제품사양... 4 제 2 장 설치 및 실행 설치 시 주의사항 설치 권고 사양 프로그램 설치 하드웨

#KLZ-371(PB)

10X56_NWG_KOR.indd

Orcad Capture 9.x

Remote UI Guide

1

Solaris Express Developer Edition

목차 윈도우드라이버 1. 매뉴얼안내 운영체제 (OS) 환경 윈도우드라이버준비 윈도우드라이버설치 Windows XP/Server 2003 에서설치 Serial 또는 Parallel 포트의경우.

Microsoft PowerPoint - User Manual pptx

Chapter 1

Coriolis.hwp

Vertical Probe Card Technology Pin Technology 1) Probe Pin Testable Pitch:03 (Matrix) Minimum Pin Length:2.67 High Speed Test Application:Test Socket

A B C D E F RRC350 RRC Roteo 35


#KM-250(PB)

B _00_Ko_p1-p51.indd

Page 2 of 6 Here are the rules for conjugating Whether (or not) and If when using a Descriptive Verb. The only difference here from Action Verbs is wh

GDUM-CL-DLT30(User Manual for Drs Light2)(EngKor)(1).ai

Page 2 of 5 아니다 means to not be, and is therefore the opposite of 이다. While English simply turns words like to be or to exist negative by adding not,

7 LAMPS For use on a flat surface of a type 1 enclosure File No. E Pilot Lamp File No. E Type Classification Diagram - BULB Type Part Mate

본문01

Series 100 IMPORTANT CUSTOMER NOTICE Sierra Instruments, Inc. is not liable for any damage or personal injury, whatsoever, resulting from the use of S

목차 1. 제품 소개 특징 개요 Function table 기능 소개 Copy Compare Copy & Compare Erase

step 1-1

Microsoft Word - Installation and User Manual_CMD V2.2_.doc

3000 Series Art. 3171B Digital intercoms Bus line Local bell input Alarm input Service push button Handset

untitled

02 Reihe bis 750 bar GB-9.03

04-다시_고속철도61~80p

K_R9000PRO_101.pdf

#KM-350AB..

APOGEE Insight_KR_Base_3P11

WOMA Pumps - Z Line

Å©·¹Àγ»Áö20p

슬라이드 1

USER Manual

Hardware Manual TSP100

# KM

<BACEBDBAC5CD20BAEAB7CEBCC52D A2DC3D6C1BE2D312D E6169>

CD 2117(121130)

BC6HP Korean.ai


온라인등록용 메뉴얼

PowerPoint 프레젠테이션

72129o

(SW3704) Gingerbread Source Build & Working Guide

VZ94-한글매뉴얼

istay

Windows 네트워크 사용 설명서

1. GigE Camera Interface를 위한 최소 PC 사양 CPU : Intel Core 2 Duo, 2.4GHz이상 RAM : 2GB 이상 LANcard : Intel PRO/1000xT 이상 VGA : PCI x 16, VRAM DDR2 RAM 256MB

, DVR. DVR. > > > " ". DVR.. ("wisenetlife.com" )? _

about_by5

DBPIA-NURIMEDIA

182 동북아역사논총 42호 금융정책이 조선에 어떤 영향을 미쳤는지를 살펴보고자 한다. 일제 대외금융 정책의 기본원칙은 각 식민지와 점령지마다 별도의 발권은행을 수립하여 일본 은행권이 아닌 각 지역 통화를 발행케 한 점에 있다. 이들 통화는 일본은행권 과 等 價 로 연

BC6DX-II Korean.ai

#KM-250š

Microsoft Word - Automap3

R50_51_kor_ch1

USER Manual

CL100B_manual_kor_m.0.2.indd

LCD Monitor

Smart Power Scope Release Informations.pages

Microsoft Word MetOne237Bmanual

서강대학교 기초과학연구소대학중점연구소 심포지엄기초과학연구소

1

PJTROHMPCJPS.hwp


untitled

<32B1B3BDC32E687770>

11¹Ú´ö±Ô

BC6DX Korean.ai

Transcription:

Intraoral Camera Autofocus Intraoral Camera with Mouse Wired type User manual Eng Kor

Intraoral Camera Autofocus Intraoral Camera with Mouse Wired type User manual Eng

Contents 1. Introduction 02 - Features - Description - Overview 2. Safety Information 03 - Symbols - Notes and reference - Installation and Connection - Operation - Maintenance 3. List of Components 07 4. Parts and functions 08 5. Installation 09 6. How to use 12 7. Maintenance 14 8. Trouble Shooting 15 9. Specification 16 10. Accessories 17 11. Warranty 17 12. Warranty card 18 01

1 Introduction Thank you for purchasing the device. The instructions described below have been designed to provide the necessary information for the successful operation, daily maintenance and safety for the use of this unit. Features - Autofocus - Gyro mouse built-in - 280 twist head - Adjustable LED brightness - Software compatibility - Easy to read OLED screen - Dental image software included (DrsViewer2) - 3 color impressions Description This device is an intraoral camera used to take images of the inside of the mouth or oral cavity. Overview 1) Camera Lens Button OLED screen 2) USB cable Connect port Connect pin USB cable 02 Autofocus Intraoral Camera with Mouse

2 Safety information It is important to understand the following information to use this product safely. Symbols Warning and Caution used in this manual are shown below. Warning Indicates a potentially hazardous situation which, if not avoided, may result in serious injury or death. Caution Indicates a potentially hazardous situation which, if not avoided, may result in minor/moderate injury or in damage of property. Notes and References Notes and References used in this manual are shown below. Note Indicates that potential malfunctions may occur if the description is ignored. Reference Supplementary information to facilitate better operation. 03

2 Safety information Installation and Connection Warning - Before use, check that there is no dust or foreign particles in the USB cable or connection part to avoid an electric shock. - Keep away from sources of ignition. - Protect the device from any liquid to avoid an electric shock or functional error. - Place the device on a plate, stable surface, or cradle supplied. Dropping the device could result in an internal defect that may cause overheating or fire. - Do not place the USB cable near a gas burner or other sources of heat. Should the cable catch on fire or become damaged, replace with a new one to avoid short-circuiting. Caution - Do not use or leave the unit in areas of high temperature or exposed to direct sunlight. Internal circuit faults may cause the device to overheat or catch on fire. - Securely connect the dust-free USB cable. Use this device in well ventilated areas, as overheating may cause ignition. 04 Autofocus Intraoral Camera with Mouse

2 Safety information Operation Warning - Do not plug in the USB cable with wet hands. This may result in an electric shock. - Do not use this product on a person with a pacemaker as it may cause malfunction of the pacemaker. - Use a disposable cover for each new client to prevent cross-infection. Caution - Do not disconnect the USB cable by pulling on the cable. This may result in an electric shock or fire. - Avoid damage or use of unnecessary force on the USB cable. This may result in an electric shock or fire. - Remove the USB cable if the device is out of use for a long period of time. - Do not use this product for any purpose other than dental use. - This device is not water prove. Use disposable cover when use to avoid wet the device. In case of malfunction due to this case, it is not covered by warranty. 05

2 Safety information Maintenance Warning - Never disassemble or repair the product, this may cause injuries, electric shock, or fire. - Avoid getting the unit wet to prevent an electric shock. - Ensure that the USB cable is disconnected prior to cleaning. Caution - If the OLED screen malfunctions, remove the USB cable and reinsert it. - Do not use solvents oil, ethanol, or acetone to cleaning and disinfection. - The user must be in charge of the operation and maintenance of the device. 06 Autofocus Intraoral Camera with Mouse

3 List of components Please check the contents described below when removing the contents from the original packaging. Camera USB cable Cradle Data CD User Manual Disposable cover x 2ea (x 100 pcs by weight) 07

4 Parts and functions 3 Button 1 Lens a Capture button 2 Head b Left button c Right button d Mode button 4 OLED screen 5 USB Cable 1 Lens - Image is reflected on the lens through prism. 4 OLED screen - Show the device states 2 Head - Twistable 280 degrees 3 Button Capture button - Image capture, focus adjusting, select Left button - Mouse left button Right button - Mouse right button Mode button - Mouse moving activate, setup mode, cancel Live image window indicate Semi or Full autofocus (SE, AF) Black & White mode indicate Color mode indicate (Original, Warm, Cool) LED brightness indicate 5 USB Cable - Connect with camera and PC. 08 Autofocus Intraoral Camera with Mouse

5 Installation 1. USB cable connection Connect the USB cable with body as follow picture. 1 2 Caution Be careful to connect the USB cable with body. Do not force too much 2. Camera connection Connect the USB cable to USB port of PC. Then device is turned on. Booting Standby (live screen off) Standby (live screen on) 09

5 Installation 3. DrsViewer2 installation - If you don t have other Viewer software < Installation DrsViewer2 screen > Reference In case to use other software, contact local dealer. 10 Autofocus Intraoral Camera with Mouse

5 Installation 4. Camera device setup - Click and hold left button and right button for 3 seconds. Then the device is turn to setup mode. - Capture button: select - Left button: down a Capture button Reference - Right button: up - Mode button: Cancel b Left button c Right button d Mode button 1) Capture key setting - Select appropriate capture key - Default value is Space Reference Capture key can be changed with HIDDrs Manager in the CD. 2) Mouse speed - Select appropriate gyro mouse speed. (5 levels) - Default level is 3 3) Turn off time - Select turn off time of device (5, 10, 15, 20, 30 mins) - Default time is 5 mins. 4) Autofocus & Autocapture - Select Disable or Enable - Default value is Disable To avoid shaking image there is Auto capture function. Reference * Auto capture: - Semi autofocus (Disable): Half click and hold the condition, image is captured after 1 seconds after get focus, and image is captured for every 2 seconds. - Full autofocus (Enable): Half click is image capture and hold the condition, image is captured for every 2 seconds. 11

6 How to use 1. Turn on the device - Connect USB cable to PC and device. Then the device is turn on with LED blink and beep sound. 2. Image capture - Click camera icon on the DrsViewer2. Then live image is shown. - Half click is focus adjusting, and click is image capture. If the mode is full autofocus mode, half click is image capture. Reference Default setup is semi autofocus. And capture key is Space To use other company software, need to check capture key. Or need to use twain driver. 3. Mouse - To move mouse cursor click mode button and shake the device. Then mouse cursor is moved as device shacked. 4. Color impression changing - Click mode button and capture button on live image. Then the color impression is changed. - Original Warm Cool color impression is rotated. 5. Brightness change - Click mode button with mouse left button. Then LED brightness is changed. Turn off Brightness LV1 Brightness LV2 Brightness LV3 is rotated. Reference Brightness change is worked on live image is on. 12 Autofocus Intraoral Camera with Mouse

6 How to use 6. Black & White mode - Click mode button with mouse right button. Then LED turn off, and live image changed to black & white mode. Normal Black & White mode is rotated. Reference Black & White mode is worked on live image is on. 7. Setup mode - Click mouse left button and mouse right button both for 3 seconds. Then setup mode is shown. - About setup mode, please refer, 5. Installation 6. Camera device setup. 8. Turn off - Click the capture button for 3 seconds, the device is turned off. - The device is turned off automatically, if there is no signal for minutes set on setup mode. Reference - User can adjust the sleep mode time for 5, 10, 15, 20, 25, and 30 minutes on setup mode. 9. Reset - If the device doesn t work normally, reset the device. Then the device will be reboot. 13

7 Maintenance Cleaning and disinfection - Clean the camera gently with clean, soft, lint-free cloth. - Avoid using solvents which contain ethanol or acetone. - Do not use sharp or pointed tools to clean as they may damage or scratch the plastic. - Be careful not to spill any liquid into the device. - Use disposable cover when use the device to avoid cross-infection and spilling any liquid into the device. Maintenance - Do not disassemble the device for any purpose. - To repair the device, please contact authorized dealer or manufacturer. - Remove the USB cable from PC, if the device is not in use for long period. 14 Autofocus Intraoral Camera with Mouse

8 Trouble shooting If the device doesn t work normally, please refer to the following points. Problem Cause and solution Button doesn t work If the button is pressed with excessive force, it would not work, try pressing the button gently. In case of installation or device setting is incorrect, the button could not work. Check the 5. Installation and 6. How to use. Display screen does not work If the USB connection is not good, or USB electric power is not enough the camera is not work. Check the USB connection. And use other USB port. Power off while in operation If the USB cable is not connected properly, the device may turn off. Check the USB cable connection. Not able to capture image Capture key-value would not match with other company dental viewer software. Please check keyboard short-cut. If you don t know it please ask the dental viewer software vendor. And check the key-value of device. If the device is not recognized well, live image is not shown. Please check camera connection or imaging device of device manager. If there is TV tuner in the PC. The image could be not shown. Check Disable the TV tuner device on the device manager. Live image is not shown If you use other company dental viewer software, it would be related with its setting. Please ask to the dental viewer software vendor. If you use other company dental viewer software, other imaging device (ex. Web-cam, etc.) should be checked for Disable. Some codec makes block the live image shown. Uninstall the codec file. (ex. klite codec and etc.) * If the trouble is not fixed after following solution, please contact your local dealer or manufacturer. 15

9 Specification Equipment Class Model: Trademark: Power supply: Protection from ingress of liquids: IC-DCAU71 Dr s Cam 5V USB power IXPO (ordinary equipment) Operating environment Ambient temperature: Relative humidity: Atmospheric pressure: 16 C to 40 C 10% to 80% 500 hpa to 1060 hpa Transport and Storage Environment Ambient temperature: Relative humidity: Atmospheric pressure: -20 C to 60 C 10% R.H. to 85% R.H. 500 hpa to 1060 hpa Additional Information Camera Operation voltage Measurement Weight Resolution Sensor/Lens type 5V Approx. 202 x 30 x 28 mm Approx. 56g 1.3 Mega pixel sensor CMOS / Liquid lens USB cable Length Approx. 3 M Disposable cover Quantity Approx. 100 pcs by weight x 2ea Raw material Polyethylene Minimum system requirement PC system: OS: USB port: 2.0 Ghz CPU, 1GB RAM Windows XP service pack 2 USB 2.0 * Upper specification is changeable without prior notice. 16 Autofocus Intraoral Camera with Mouse

10 Accessories USB cable Cradle Disposable cover (x 100 pcs by weight) 11 Warranty This product is only shipped after strict inspection. Should the product incur any problems under normal use conditions within one year from the date of purchase, the repair will be free of charge. However, repair of consumables (Disposable Cover, and etc.) are not covered by the warranty. For more information, refer to the 12. Warranty card attached. Serial number check. Gruneworld GmbH Gerhard-Domagk-Str.2, 53121 Bonn, Germany TEL: +49(0)288/7077695 FAX: +49(0)288/7077696 Website: www.gooddrs.de S/N : DCAU 04160001 Good Doctors Co., Ltd. #208, B-dong, 283 Bupyeong-daero, Bupyeong-gu (Woolim Lions Valley, Cheongchoen-dong), Incheon, 21315, Republic of Korea Tel : + 82 32 424 6325 Fax : + 82 32 424 6326 E-mail : info@gooddrs.com Website : www.gooddrs.com 17

12 Warranty card We guarantee the quality df the product as follows Name of product : < Assurance details > Name of model : Customer information - Office name : - Office phone : Distributor - Dealer name : Assurance period - Date of purchase : from,, 20 Product is for 1 year except accessories. 1. If there is any defect of manufacturer or product has any fault itself within the assurance period, it will be replaced with the same product. 2. Below cases are not effective for the free refund. - Malfunction and damage according to user s carelessness. - Malfunction and damage according to natural disaster such as fire, earthquake and flood etc. - Malfunction and damage according to user s intention or accident. - Malfunction and damage according to using incompaible product. 3. The manufacturer does not accept any liability resulting misuse. Good Doctors Co., Ltd. #208, B-dong, 283 Bupyeong-daero, Bupyeong-gu (Woolim Lions Valley, Cheongchoen-dong), Incheon,21315, Republic of Korea Tel: +82 32 424 6325 Fax: +82 32 424 6326 18 Autofocus Intraoral Camera with Mouse

Intraoral Camera Autofocus Intraoral Camera with Mouse Wired type User manual Kor

목차 1. 소개 22 - 특징 - 사용목적 - 개요 2. 안전에관한정보 23 - 기호 - 노트와참조 - 설치시 - 사용시 - 유지보수시 3. 내용물 27 4. 부품및기능 28 5. 설치방법 29 6. 사용방법 32 7. 유지보수 34 8. 문제해결 35 9. 기재사항 36 10. 악세서리 37 11. 품질보증 37 12. 품질보증서 38 21

1 소개 본제품을구매해주셔서감사드립니다. 본매뉴얼에는제품설치, 사용및유지보수에관한사항이적혀있습니다. 안전하고원활한사용을위하여본매뉴얼을꼭읽고숙지해주시길바랍니다. 특징 - 오토포커스 - 내장형자이로마우스 - 280도회전헤드 - LED밝기조절가능 - 소프트웨어호환성 - OLED 화면 - DrsViewer2 소프트웨어 - 3가지색감선택가능 사용목적 구강내를비추어확대해볼수있는카메라장비 개요 1) 카메라 렌즈 버튼 OLED 스크린 연결포트 2) USB 케이블 연결핀 USB 케이블 22 Autofocus Intraoral Camera with Mouse

2 안전에관한정보 다음의정보들은제품의안전한사용을위한표시입니다. 기호 경고 발생할경우심각한부상이나죽음에이를수있는잠재적인위험요소 주의 발생할경우가벼운부상이나재산상의피해를야기하는잠재적인위험요소 노트와참조 노트및참조표시는다음의경우에표시됩니다. 노트 무시할경우제품의고장을야기할수있는사항 참조 보다나은사용을위한부가정보 23

2 안전에관한정보 설치시 경고 - 사용전에 USB 케이블안에먼지등이물질이있는지확인하시기바랍니다. 감전의위험이있습니다. - 발화물질등에제품을가까이두지마십시오. - 감전이나기능적인에러등을방지하기위해액체나습기등으로부터제품을보호해주십시오. - 제품을동봉된크래들이나평평하고안정된곳에위치해두십시오. 제품을떨어뜨릴경우내부적인고장이나발열, 화재등의위험이있을수있습니다. - USB 케이블을가스버너나열기구등근처에두지마십시오. 케이블이손상된경우구입처나제조사로연락주십시오. 주의 - 제품을온도가높은곳이나직사광선이비치는곳에두지마십시오. 내부적인기능문제, 발열혹은화재의위험이있습니다. - 발열이나발화를방지하기위해제품사용시환기가잘되는곳에서사용하십시오. 24 Autofocus Intraoral Camera with Mouse

2 안전에관한정보 사용시 경고 - 젖은손으로 USB 케이블을꽂지마십시오. 감전의위험이있습니다. - 제품을피스메이커를장착하고있는사람에게사용하지마십시오. 피스메이커의고장을일으킬수도있습니다. - 교차감염을방지하기위해일회용커버를반드시사용하십시오. 주의 - 사용중 USB 케이블을분리하지마십시오. 감전이나화재, 고장등을일으킬수있습니다. - USB 케이블에불필요한힘을가하거나충격으로부터보호하십시오. 감전이나화재의위험이있습니다. - 제품을오랜기간동안사용하지않는경우에는 PC 로부터분리를해두십시오. - 본제품을치과용목적이외의목적으로사용하지마십시오. - 본제품은방수가되지않는제품입니다. 제품이젖는것을방지하기위해서반드시일회용커버를사용하시기바랍니다. 침수에의한고장은제품보증에대한사항에서적용되지않습니다. 25

2 안전에관한정보 유지보수시 경고 - 제품을임의로분해하거나수리하지마십시오. 부상이나감전, 혹은화재의위험이있습니다. - 젖은손으로제품을잡지마십시오. 감전의위험이있습니다. - 제품을청소하기전에 USB 케이블을반드시분리하시기바랍니다. 주의 - 제품의 OLED 화면이고장난경우에는, USB 케이블을분리한후다시꽂아주시기바랍니다. - 솔벤트오일, 에탄올혹은아세톤등은사용하지마십시오. - 사용자는제품사용과관리의책임이있습니다. 26 Autofocus Intraoral Camera with Mouse

3 내용물 제품개봉후다음과같은내용물들이있는지확인바랍니다. 카메라 USB 케이블 크래들 데이터 CD 매뉴얼 일회용커버 2ea ( 약 100 매 ) 27

4 부분및기능 3 버튼 1 렌즈 a 캡쳐버튼 2 헤드 b 왼쪽버튼 c 오른쪽버튼 d 모드버튼 4 OLED 스크린 5 USB 케이블 1 렌즈 2 헤드 - 280 도회전 3 버튼 a 캡쳐버튼 - 이미지캡쳐, 포커스조절, 선택 b 왼쪽버튼 - 마우스왼쪽버튼 c 오른쪽버튼 - 마우스오른쪽버튼 d 모드버튼 - 마우스움직임활성화, 세팅모드, 취소 4 OLED 스크린 - 제품상태를보여줌. 라이브이미지윈도우표시세미 / 오토포커스 (SE, AF) 흑백모드표시컬러모드표시 (Original, Warm, Cool) LED 밝기표시 5 USB 케이블 - 카메라와 PC 연결 28 Autofocus Intraoral Camera with Mouse

5 설치방법 1. USB 케이블연결 그림과같이 USB 케이블을연결해주십시오. 1 2 주의 USB 케이블을케메라에연결할때는너무많은힘을주지않도록주의해주십시오. 2. 카메라연결 캡쳐버튼을누름과함께시작됩니다. 그리고나서장치는화면을인식합니다. 부팅로고 대기화면 ( 라이브스크린꺼짐 ) 대기화면 ( 라이브스크린켜짐 ) 29

5 설치방법 3. DrsViewer2 설치 - 만약다른뷰어소프트웨어가없다면 DrsViewer2 를설치하십시오. < DrsViewer2 설치화면 > 참조 다른소프트웨어를사용하는경우에는구입처에연락하십시오. 30 Autofocus Intraoral Camera with Mouse

5 설치방법 4. 카메라장치설정 - 왼쪽버튼과오른쪽버튼을동시에 3 초동안누르고있으면설정모드로바뀝니다. - a 캡처버튼 : 선택 - b 왼쪽버튼 : 아래 a 캡처버튼 Reference - c 오른쪽버튼 : 위 - d 모드버튼 : 취소 b 왼쪽버튼 c 오른쪽버튼 d 모드버튼 1) 캡쳐키값세팅 - 올바른캡쳐키를선택하십시오. - 초기값은스페이스입니다. 참조 캡쳐키는 CD 안에있는 HIDDrs Manager" 에서바꿀수있습니다. 2) 마우스스피드 - 자기에맞는속도 (5 레벨 ) 를선택하십시오. - 초기값은 3 레벨입니다. 3) 종료시간 - 장치의꺼지는시간을선택하시오.(5,10,15,20,30 분 ) - 초기값은 5 분입니다. 4) 오토포커스와오토캡쳐 - Disable 혹은 Enable 선택하시오 - 초기값은 "Disable" 입니다. 참조 사진촬영시, 흔들림을방지하기위한자동캡쳐기능이있습니다. * 자동캡쳐 - 세미오토포커스 (Disable): 하프클릭으로포커스를맞춘상태에서, 하프클릭을유지하면처음의 1초뒤에사진이찍히며, 매 2초마다사진이찍힙니다. - 풀오토포커스 (Enable): 하프클릭으로사진이찍히며, 하프클릭을유지하는경우매 2초마다사진이찍힙니다. 31

6 사용방법 1. 전원켜기 - PC 의 USB 포트에 USB 케이블을연결하면 LED 가깜박거리고삐소리가나면서켜집니다. 2. 이미지캡쳐 - DrsViewer2에카메라아이콘을클릭하십시오. 라이브이미지가보여집니다. - 포커스를조절하기위해서카메라아이콘을살짝눌러주십시오. 누르면이미지가캡쳐됩니다. 오토포커스모드에서는반셔터기능이작동하지않습니다. 참조 디폴트설정은세미오토포커스이고캡쳐키는 스페이스 입니다. 다른회사소프트웨어는캡쳐키를체크해보거나트와인드라이버를사용해야만합니다. 3. 마우스 - 마우스커서를움직이기위해서는모드버튼을누른상태에서카메라를움직이십시오. 마우스커서는카메라가움직이는대로움직입니다. 4. 색감변화 - 모드버튼과캡쳐버튼을라이브화면상에서눌러주면색감이바뀝니다. - Original Warm Cool 순서로바뀝니다. 5. 밝기조절 - 모드버튼과마우스왼쪽버튼을클릭하면 LED 밝기가변합니다. 꺼짐 밝기 1 밝기 2 밝기 3 순서로바뀝니다. 참조 밝기조절은카메라기능이활성화되어있을때만작동합니다. 32 Autofocus Intraoral Camera with Mouse

6 사용방법 6. 흑백모드 - 마우스오른쪽버튼과모드버튼을클릭하십시오 LED 가꺼지고라이브화면이흑백으로변합니다. 일반 흑백모드 참조 흑백모드는라이브화면이떠있을때만작동합니다. 7. 설정모드 - 마우스왼쪽오른쪽버튼을동시에 3초동안클릭하면설정모드가나옵니다. - 설정모드는, 5. 설치방법 6. 카메라장치설정 을참고하십시오. 8. 꺼짐 - 캡쳐버튼을 3 초동안누르면꺼집니다. - 장치는자동적으로꺼집니다. 만약몇분동안에도신호가없다면설정모드를실행해보십시오 참조 - 사용자는슬립모드시간을 5,10,15,20,25,30 분을설정모드에서조절할수있습니다. 9. 리셋 - 만약기기가정상적으로작동하지않는경우, 리셋을하십시오. 기기가재부팅됩디다. 33

7 유지보수 청소및소독 - 제품청소시, 부드럽고, 세정제등이첨가되어있지않은천등으로부드럽게닦아주십시오. - 에탄올, 아세톤등이포함된용매의사용을금합니다. - 날카로운기구등으로제품을청소하지마십시오. 제품에스크래치나고장등을일으킬수있습니다. - 본제품은방수가되지않은제품입니다. 물기나습기로부터주의해주십시오. - 교차감염과장치에액체가들어가는일을막기위해서일회용커버를사용하십시오. 유지보수 - 어떠한경우라도제품을임의로분해하지마십시오. - 제품수리시, 공인된딜러혹은제조자에게연락하십시오. - 제품을오랫동안사용안할시 USB 케이블을 PC 에서분리해주십시오. 34 Autofocus Intraoral Camera with Mouse

8 문제해결 제품이정상적으로작동을하지않는경우다음을참조하여주십시오. 문제 원인및해결 버튼이작동하지않는경우 버튼에무리한힘이가해졌을경우, 버튼이작동하지않을경우제품이작동하지않을수있습니다. 버튼을천천히눌러주시고, 버튼의상태를확인하여주십시오. 제품의설치가제대로되지않는경우버튼이작동하지않을수있습니다. "5. 설치방법 " 과 "6. 사용법 " 을참조하여주십시오. OLED 화면이작동하지않는경우 USB 케이블이제대로연결되지않을경우, 작동이제대로되지않을수있습니다. USB 케이블의연결상태를확인하여주십시오. USB 포트의전원이낮아서제품이작동을하지않을수있습니다. 다른 USB 포트에연결하여주십시오. 사용중제품이꺼지는경우 USB 케이블이제대로연결되지않을경우, 제품이꺼질수있습니다. USB 케이블의연결상태를확인하여주십시오. 이미지캡쳐가되지않는경우 다른회사의덴탈뷰어소프트웨어를사용하는경우캡쳐키값이올바르지않아캡쳐가되지않을수있습니다. 해당소프트웨어의캡쳐를위한키보드값을확인하여주십시오. 만약해당소프트웨어의캡쳐키값을모르는경우해당소프트웨어업체에문의를하시기바랍니다. "HIDDrsManager" 파일을이용하여키값을변경시켜주십시오. 제품인식이잘되지않는경우에, 라이브화면이보이지않을수있습니다. USB 연결상태를확인해주시고, 장치관리자의이미징장치를확인하여주십시오. 만약 PC 에 TV 튜너가설치되어있다면장치관리자에서해당 TV 튜너를 " 사용안함 " 으로설정하여주시기바랍니다. 라이브화면이보이지않는경우 다른회사의덴탈뷰어소프트웨어를사용하는경우, 세팅의문제와관련이있을수있습니다. 해당덴탈뷰어소프트웨어업체에문의하시기바랍니다. 다른회사의덴탈뷰어소프트웨어를사용하는경우, 다른이미징장치 ( 웹캠등 ) 를 " 사용안함 " 으로설정하여주시기바랍니다. 특정코덱이설치되어있는경우 ( 예. Klite codec) 제품영상이나오지않을수있습니다. 해당코덱을지워주시기바랍니다. * 상기의조치를취한후에도증상이고쳐지지않는경우구입처나생산자에게문의해주십시오. 35

9 기재사항 - 제품명 : 구강용카메라 - 형명 : IC-DCAU71 - 상품명 : Dr s Cam - 제조업체 : 주식회사굿닥터스 - 주소 : 인천광역시부평구부평대로 283 B 동 208 호 ( 청천동, 우림라이온스밸리 ) ( 우 21315) - 연락처 : 032) 424-6325 - 제조업허가번호 : 제 2341 호 - 제조품목신고번호 : 경인제신 14-671 호 검토요청 - 제조년월및제조번호 : 제품에표시 - 사용목적 : 구강내를비추어확대해볼수있는카메라장비 - 수량 : 1 SET - 사용방법및사용상의주의사항 : 사용자매뉴얼참조 - 본제품은의료기기입니다. 부가정보 카메라 작동전압치수무게해상도센서 / 렌즈타입 5V 약 202 x 30 x 28 mm 약 56g 1.3 Mega pixel sensor CMOS / 액체렌즈 USB 케이블 길이 약 3 M 일회용커버 수량 약 100장 ( 무게기준 ) x 2 팩 원재료 폴리에틸렌 최소사양 PC환경 OS USB포트 2.0 Ghz CPU, 1GB RAM Windows XP 서비스팩 2 USB 2.0 * 상기의스펙은사전공지없이변경될수있습니다. 36 Autofocus Intraoral Camera with Mouse

10 악세서리 USB 케이블 크래들 일회용커버 (x 100 매 ) 11 품질보증 본제품은엄격한품질관리하여출고된제품입니다. 정상적인작동환경에서문제없이사용할수있습니다. 정상적인작동환경에서사용하여문제가생기는경우구입일로부터 1 년간무상으로수리가가능합니다. 그러나소비재의 ( 일회용커버등 ) 경우는품질보증에서제외됩니다. 자세한사항은첨부되어있는품질보증서를참조하여주시기바랍니다. 시리얼번호확인방법 S/N : DCAU 04160001 월년일련번호 37

12 품질보증서 품질보증서 ( 우 21315) 인천광역시부평구부평대로 283, B 동 208 호 ( 청천동우림라이온스밸리 ) Tel:032-424-6325 Fax:032-424-6326 Email:info@gooddrs.com Website:http://www.gooddrs.com 38 Autofocus Intraoral Camera with Mouse

Rev.0 Address. #208, B-dong, 283 Bupyeong-daero, Bupyeong-gu (Woolim Lions Valley, Cheongchoen-dong), Incheon,21315, Republic of Korea Tel. +82-32-424-6325 Fax. +82-32-424-6326 Website. www.gooddrs.com E-mail. sales@gooddrs.com / info@gooddrs.com