APOGEE Solutions for BACnet Networks
BACnet ASHRAE 위원회내에서개발 ASHRAE (American Society of Heating, Refrigerating and Air- Conditioning Engineers ) 가이드라인, 최종사용자와생산자에게오픈멤버쉽보장 ANSI, ISO, CEN 에서채택됨 무료배포, 라이센스없음 세계적으로수백개의업체들에의해사용 SSPC-135 ASHRAE Committee, BTL and BACnet International 에서활발히활동
Certification - BTL Mark
APOGEE BACnet System s10 매니지먼트레벨 (MLN), 오토메이션레벨 (ALN), 필드레벨네트워크 (FLN) 등모든레벨에서 ANSI/ASHRAE standard BACnet/IP를지원 BTL (BACnet Testing Laboratory) 충족 B-OWS (BACnet Operator Workstation Software) Insight BACnet client and server B-BC (BACnet Building Controller) BACnet MEC / MBC / PXC Compact B-ASC (BACnet Application Specific Controller) BACnet TEC
슬라이드 4 s10 영문약자첨부 아키텍처그림첨부 ANSI 란? 마지막줄이해가안가요. sel02640, 2007-08- 27
APOGEE BACnet 시스템아키텍쳐 Management Level Ethernet TCP/IP and/or BACnet/IP BACnet/IP Automation Level RS-485 P2 Field Level BACnet, BACnet, Chillers Boilers Lighting Power Monitoring PLCs
APOGEE 매니지먼트레벨 Insight BACnet 클라이언트또는서버 Ethernet BACnet/IP 상에서 BACnet 디바이스들과통신 BACnet 을통해감시, 명령, 스케줄링, 경향, 경보기능제공 Management- Level Network Ethernet TCP/IP 와 BACnet/IP BACnet/IP
BACnet 클라이언트 / 서버 BACnet 클라이언트 : 데이터사용자 (A) BACnet 서버디바이스에대해정보요청 BACnet 서버디바이스에대해변경요청 BACnet 서버 : 데이터제공자 (B) 클라이언트서버관계 BACnet 클라이언트디바이스에정보제공 BACnet 클라이언트디바이스의변경 요청에응답
PICS: BACnet Operator Workstation (B-OWS) BACnet Protocol Implementation Conformance Statement Products Product Model Number Protocol Revision Software Version Firmware Version Insight workstation with BACnet Client Operator Workstation 571-188 135-2004 3.7 N/A Insight workstation with BACnet Server Operator Workstation 571-189 135-2004 3.7 N/A Date Tested: Not Tested No BTL test currently available for B-OWS Vendor Information Siemens 1000 Deerfield Parkway Buffalo Grove, IL 60089 www.sbt.siemens.com Product Description The Insight workstation provides a powerful and comprehensive interface to manage and control a facility within a user friendly operating environment. The Insight workstation, combined with the multi-tasking environment of Windows 2003/XP/2000, provides ease-of-use, power, connectivity, and manageability. The Insight workstation with BACnet provides an integration platform to work with other BACnet enabled systems and devices using either the BACnet Ethernet or BACnet/IP protocol. BACnet Standardized Device Profile Supported Device Profile BACnet Operator Workstation (B-OWS) BACnet Building Controller (B-BC) BACnet Advanced Application Controller (B-AAC) BACnet Application Specific Controller (B-ASC) BACnet Smart Actuator (B-SA) BACnet Smart Sensor (B-SS)
APOGEE Insight Client 적용예 (1) BACnet 클라이언트로서의 APOGEE Insight BACnet 서버로서의다른 BACnet VAndor BAS Controllers BACnet System 1 BACnet System 2 BACnet System 3
APOGEE Insight Client 적용예 (2) BACnet 클라이언트로서 APOGEE Insight BACnet 서버로서의 BAS Controllers
APOGEE Insight Client 적용예 (3) BACnet 클라이언트로서의 APOGEE Insight BACnet 서버로서의타사 BAS controllers
BACnet 오토메이션레벨 P2P 통신을위한 BACnet/IP 지원 MBC (Modular Building Controller) MEC (Modular Equipment Controller) PXC Compact BTL 의 B-BC 인증획득 BACnet/IP Management Automation Level Network Level Network
MBC Controller with Power Open Processor 유연성있는 I/O 관제점확장장치이용없이최대 296 개의관제점수용 BACnet/IP 프로토콜을이용하여 B-BC (BACnet Building Controller) 로서 BTL (BACnet Testing Laboratories) 인증획득 지원을위해펌웨어 3.0 필요 FLN 지원
Power MEC Controller 고정형 I/O 옵션에따른다양한모델 : BACnet /IP 연결 RS-485 ALN 지원 TCP/IP Ethernet ALN 지원 BACnet/IP 프로토콜을이용하여 B-BC(BACnet Building Controller) 로서 BTL (BACnet Testing Laboratories) 인증획득 지원을위해펌웨어 3.0 필요 FLN 지원
BACnet PXC Compact 기존 ALN PXC Compact 하드웨어이용 루프탑옵션이용가능 16/ 24 관제점옵션 소프트웨어로가능한 TX-IO 기술 BACnet/IP 프로토콜을이용하여 B-BC(BACnet Building Controller) 로서 BTL (BACnet Testing Laboratories) 인증획득 지원을위해펌웨어 3.0 필요
PICS: BACnet Building Controller (B-BC) BACnet is a registered trademark of ASHRAE. ASHRAE does not endorse, approve or test products for compliance with ASHRAE standards. Compliance of listed products to the requirements of ASHRAE Standard 135 if the responsibility of the BACnet Manufacturers Association (BMA). BTL is a registered trademark of the BMA. BACnet Testing Labs Product Listing This product has been tested at the BACnet Testing Labs and found to comply with all the necessary interoperability requirements in place on the published test date. This listing represents the tested capability of the Listed Product. For information on additional functionality that was not covered in the test process, refer to the Manufacturer s PICS statement on the BMA website. Listing Information Vendor Siemens 1000 Deerfield Parkway Buffalo Grove, IL 60089 www.sbt.siemens.com Listing Status Listed Product Test Requirements BACnet Protocol Revision Date Tested Requirements as of May 2005 135-2004 February 2006 Product Name Model Number Software Version Power Open Processor for BACnet/IP Networks Power Open Processor for BACnet/IP 3.0 1200-EFB 1210-EFB 1200-ELB Power Modular Equipment Controller for BACnet/IP 1210-ELB Networks 1100-EB 3.0 1110-EB 1200-EB 1210-EB PXC Compact for BACnet/IP Networks PXC16 PXC24 3.0 Product Name Power Open Processor for BACnet/IP Networks Power Modular Equipment Controller for BACnet/IP Networks PXC Compact for BACnet/IP Networks Link to PICS on BMA Website http://www.bacnetassociation.org/mfr/prod1 http://www.bacnetassociation.org/mfr/prod2 http://www.bacnetassociation.org/mfr/prod3
BACnet 필드레벨 BACnet TEC 마스터 / 슬레이브또는 P2P 통신을위해 BACnet MS/TP 지원 BTL 의 B-ASC 인증획득 Field Level Network BACnet MS/TP
BACnet Terminal Box (VAV) Controller 애플리케이션마다독특한제어알고리즘 BACnet MS/TP 이용하여필드패널과연결 BACnet MS/TP 프로토콜을이용하여 B-ASC(BACnet Application Specific Controller) 로서 BTL (BACnet Testing Laboratories) 인증획득
PICS: BACnet Application Specific Controller (B-ASC) BACnet is a registered trademark of ASHRAE. ASHRAE does not endorse, approve or test products for compliance with ASHRAE standards. Compliance of listed products to the requirements of ASHRAE Standard 135 if the responsibility of the BACnet Manufacturers Association (BMA). BTL is a registered trademark of the BMA. BACnet Testing Labs Product Listing This product has been tested at the BACnet Testing Labs and found to comply with all the necessary interoperability requirements in place on the published test date. This listing represents the tested capability of the Listed Product. For information on additional functionality that was not covered in the test process, refer to the Manufacturer s PICS statement on the BMA website. Listing Information Vendor Listing Status Siemens BAU NA 1000 Deerfield Parkway Buffalo Grove, IL USA 60089 www.sbt.siemens.com Listed Product Test Requirements BACnet Protocol Revision Date Tested Requirements as of May 2005 135-2001b August 2005 Product Name Model Number Software Version BACnet Terminal Equipment Controller - FC 550-789A Rev. 1.2 BACnet Terminal Equipment Controller - HP 550-790A Rev. 1.2 Product Name BACnet Terminal Equipment Controller - FC BACnet Terminal Equipment Controller - HP Link to PICS on BMA Website http://www.bacnetassociation.org/mfr/prod1 http://www.bacnetassociation.org/mfr/prod1
BIG-EU : SBT BACnet 제품인증현황