COMbricks Main Slide Set

Similar documents
Parameterization


High Available SIMATIC S7-400H


KDTÁ¾ÇÕ-1-07/03

12하이브리드브로셔-국문

歯Cablexpert제안서.PDF

1.LAN의 특징과 각종 방식

CPX-E-SYS_BES_C_ _ k1

Smart IO_K_121108

CPX-E-PB_BES_C_ _ k1

FTTH 기술발표

Microsoft Word - FS_ZigBee_Manual_V1.3.docx

KDTÁ¾ÇÕ-2-07/03

歯A1.1함진호.ppt

Smart Power Scope Release Informations.pages

Smart IO_K_160427

TTA Verified : HomeGateway :, : (NEtwork Testing Team)

PRO1_04E [읽기 전용]

歯I-3_무선통신기반차세대망-조동호.PDF


2

untitled

PCServerMgmt7

istay

VZ94-한글매뉴얼


thesis

LDK-300 제안서

PRO1_16E [읽기 전용]

<BACEBDBAC5CD20BAEAB7CEBCC52D A2DC3D6C1BE2D312D E6169>

RFID USN_K_100107

Å©·¹Àγ»Áö20p

chapter4

PowerPoint 프레젠테이션

Microsoft PowerPoint - ch03ysk2012.ppt [호환 모드]

(specifications) 3 ~ 10 (introduction) 11 (storage bin) 11 (legs) 11 (important operating requirements) 11 (location selection) 12 (storage bin) 12 (i

MAX+plus II Getting Started - 무작정따라하기

APOGEE Insight_KR_Base_3P11

Information Memorandum Danam Communications Inc

PowerChute Personal Edition v3.1.0 에이전트 사용 설명서

1217 WebTrafMon II


i-movix 특징 l 안정성 l 뛰어난화질 l 차별화된편의성

review hwp


airDACManualOnline_Kor.key

슬라이드 제목 없음

歯DCS.PDF

F1-1(수정).ppt

Microsoft PowerPoint - CoolMessenger_제안서_라이트_200508


PowerPoint 프레젠테이션

歯기구학

<4D F736F F D20C0CCBEBEC1A6BEEE5FC3A5BCD2B0B35F >

CMSX-C-U-F1_BES_C_ b_ k1

인켈(국문)pdf.pdf

SMB_ICMP_UDP(huichang).PDF

(Table of Contents) 2 (Specifications) 3 ~ 10 (Introduction) 11 (Storage Bins) 11 (Legs) 11 (Important Operating Requirements) 11 (Location Selection)

OEM Machine I/O : DeviceNet, PROFIBUS 2 - : RSA, Rockwell Automation, Mastushita PDN I/O, Point I/O - : Rockwell Automation ODM FnIO : DeviceNet, PROF

1. PVR Overview PVR (Personal Video Recorder), CPU, OS, ( 320 GB) 100 TV,,, Source: MindBranch , /, (Ad skip) Setop BoxDVD Combo

2 PX-8000과 RM-8000/LM-8000등의 관련 제품은 시스템의 간편한 설치와 쉬운 운영에 대한 고급 기술을 제공합니다. 또한 뛰어난 확장성으로 사용자가 요구하는 시스템을 손쉽게 구현할 수 있습니다. 메인컨트롤러인 PX-8000의 BGM입력소스를 8개의 로컬지

s SINUMERIK 840C Service and User Manual DATA SAVING & LOADING & & /

Microsoft Word - Installation and User Manual_CMD V2.2_.doc

Microsoft PowerPoint - AC3.pptx

Backup Exec

歯최덕재.PDF

歯CRM개괄_허순영.PDF

02 Reihe bis 750 bar GB-9.03

°í¼®ÁÖ Ãâ·Â

<23C0B1C1A4B9E65FC6EDC1FDBFCFBCBA E687770>

PRO1_02E [읽기 전용]

I What is Syrup Store? 1. Syrup Store 2. Syrup Store Component 3.

Microsoft PowerPoint - eSlim SV [ ]

CPX-E-EC_BES_C_ _ k1

untitled

<3034B1E2B9DD32302DBAB8B0EDBCAD2D DC0FCC6C4C0DABFF BAB0C3A53420C8A8B3D7C6AEBFF6C5A9292E687770>

untitled

untitled

T100MD+

歯AG-MX70P한글매뉴얼.PDF

슬라이드 1

학습영역의 Taxonomy에 기초한 CD-ROM Title의 효과분석

00829A_SHR-6164-KOR.indb

PowerPoint 프레젠테이션

Microsoft Word - 1-차우창.doc

안전을 위한 주의사항 제품을 올바르게 사용하여 위험이나 재산상의 피해를 미리 막기 위한 내용이므로 반드시 지켜 주시기 바랍니다. 2 경고 설치 관련 지시사항을 위반했을 때 심각한 상해가 발생하거나 사망에 이를 가능성이 있는 경우 설치하기 전에 반드시 본 기기의 전원을


BC6HP Korean.ai

Plc\PLC-p

슬라이드 제목 없음

¼º¿øÁø Ãâ·Â-1

<C0CCBCBCBFB52DC1A4B4EBBFF82DBCAEBBE7B3EDB9AE2D D382E687770>

LG-LU6200_ICS_UG_V1.0_ indd

Install stm32cubemx and st-link utility

untitled

LAN케이블링

PLC Robot Starter Quick Guide


Chapter11OSPF

Transcription:

PHONE :, FAX : 2644 E-mail: COMbricks Networking, Monitoring and Control

COMbricks 개요 Web server `with ProfiTrace ProfiTrace 2 CommDTM SNMP OPC Email TELNET Ethernet / Internet Monitoring networks PN/PN coupler Redundancy Star networks T T Non-standard cable Fiber optic Alarm contacts I/O DP/DP coupler PN/DP coupler I/O 2

다양한종류의미디어구성 Redundancy 12 Mbps Ethernet ProfiTrace CommDTM 10 modules Ethernet RS 485 Non-PROFIBUS Fiber optic 3

강력한 backplane 구조 Example 1: Example 2: Repeaters Fiber Optic Head Station Modular repeaters Remote I/O station PROFIBUS and PROFINET Example 3: Up to 32 modules (10 high speed modules) DP Slave PN Device I/O dig, rel Mix of modules Repeaters, I/O, etc. 4

Modular Repeaters Redundancy 6

프로피버스의분할 (Segmentation) 은필수!! 프로피버스의분할 (Segmentation) 은단순히물리적한계 ( 노드수, 거리 ) 의확장만을위한것이아니다... 사용환경에서발생되는공통적인 fault 를차단내지는분산시키는효과. 민감, 취약한구역을차폐하여고장을없애는기능. spur line( 네트워크의 T 분기 ) 의한계를넘어서는방안. 가동중에도확장이나제거를자유롭게.. 생산공정의구간을서로전기적으로차단. 제어시스템을보호 전기적차단효과에의하여.. 실제로상존하는대부분의네트워크문제가 Segmentation 에의해해결됩니다. 7

분할 (Segmentation) 실제사례 ( 발췌 ) 8

ProfiHub A5/B5 적용사례 ( 발췌 ) Paper production (Rhein Papier Germany) 410 대 x ProfiHub B5 사양 : PROFIBUS DP Baudrate: 1,5 Mbps 시스템 : - Siemens S7 PLC - Siemens Simocodes ProfiHub 적용이유 - 장거리의분기라인 - 가동중디바이스의추가 및제거를자유롭게 - 안정된버스의구성 ( 트러블로인한다운타임의감소 ) - 신기술제품의시스템구성 9

분할 (Segmentation) 의방안 표준 repeaters ProfiHubs COMbricks ProfiTrace OE - 1 Meter rule problems - Termination problems - Power supply overload - 비용과설치작업의문제 - 5 채널고정 - 프로피버스 /MPI 전용 - No asset management - Single power supply - Modular and hotswap - ProfiTrace over Ethernet - Bus redundancy integrated - Fibre, I/O and PROFINET 10

모듈형 repeaters (ProfiHub 기능 ) 1 channel repeaters ProfiTrace OE LEDs G-isolation Hot extendible Hot swap 2 segments 최대 10 modules (2 channel repeaters) 2 segments 1 channel 과 2 channel repeaters 의혼합구성 혁신 : 최대크기의 backbone 3 segments 20 segments 참조 : Segment 는 PROFIBUS rule 에부합됨 (31 devices, 12 Mbps = 100 m, 1.5 Mbps = 200 m) 11

ProfiHub versus COMbricks 비교 ProfiHub ( 단순 ) COMbricks ( 유연한신기술 ) 본체에 5개확장포트고정 프로피버스전용 RS-485 설치가간편 IP65 version 가격이저렴 모듈방식 다중인터페이스 (PB, PN, MPI) 다중네트워크 (4 PBs, Redundancy) 트레이스 ( ProfiTrace OE) 설비관리 (Asset Management) 가볍다 (IP65 외함이용가능 ) 12

EMC Barrier - 1 Network 에 2 segments - The isolation and bit recovery provide a barrier for electrical sensitive segments. 전기적분리 Max. 1200 m Max. 31 devices Clean signal Max. 1200 m Max. 31 devices Noisy signal 민감한구역과노이즈발생구역간의전기적분리 (Segmentation) 와차단 (barrier) Damage 방지 13

Redundancy ( 네트워크 redundancy 다중화 ) ProfiTrace OE Dipswitch or web config. Hot swap Alarm relay 최대 10 redundant cables redundant channels 케이블경로를다르게하여안정성확보가능 혁신 : 10 배의 redundancy 참조 : Repeaters 는 1 혹은 2 channel type 선택 15

사례 : 3 중 Redundancy (3 segments) Info: - 1 네트워크에서 3 redundant segments - 1CH repeater 로서구성 - 이사례에서는네트워크속도가 1.5 Mbps (200 m) Redundant 200 m ProfiTrace OE 200 m 200 m 200 m 3 4 5 6 7 8 9 10 16

사례 : 2 중 Redundancy (2 segments) Info: - 1 네트워크에서 2 redundant segments - 1CH repeater 로서구성 17

PHONE :, FAX : 2644 E-mail: ProfiTrace in a web server

PROFIBUS 관련제품기술의진보 2010 2003/2007 ProfiTrace 2 PROCENTEC (USB, Oscilloscope Master, OPC, DTM) 2006 ProfiHuB ProfiTrace OE - COMbricks - PROCENTEC (ProfiTrace in the network components and No software) 22

COMbricks 는미래지향의대책임 PROFIBUS 설치및통신상태를상시감시 프로젝트시작시부터반영함이추세임 문제발생가능성있을때부터 Warnings Ethernet/Internet : PROFIBUS에는물리적, 논리적영향가능성이원천적으로없음. PC를항상설치해놓을필요없이필요시간단히 connection Operating system 이나 platform independent Expert 가아니어도용이하게인지 23

예 : 원격감시의최소구성 Message recording Statistics Live List Log Email 웹브라우저로!! Bar graph Oscilloscope Segment 2 (repeater function) 1 PROFIBUS Network Segment 1 Live List 구성 : - 1 Head Station - 1 Repeater module 24

예 : 여러세그먼트의감시 ( 한네트워크 ) Browser 구성 : - 1 Head Station - 최대 10 Repeater modules (2 channels / each) = 20 채널 ProfiTrace OE WWW 1 PROFIBUS Network Segment 1..5 25

Segments 와 Networks 를 BAR Graph 및 Scoping (Scope Module 적용시!!) ProfiTrace OE Segment 3 Segment 2 SCOPE repeater 는개별 segments 나 networks 를 Oscilloscope 와 Bar Graph 로감시. SCOPE repeaters 는보통의 repeater 기능에감시기능을더한제품임 4 Segment 1 Segment 3 2 3 1 11 12 13 Segment 2 24 55 83 Scope Module 적용시!! 26

예 : 여러네트워크감시 N1 N2 N2 N3 N4 Browser ProfiTrace OE WWW 4 PROFIBUS Networks 구성 : - 1 Head Station - 최대 10 Repeater modules (2 channels / each) = 20 채널 N1 N2 N2 N3 N4 27

사례 : 여러네트워크감시 (1) Info: - 서로다른통신속도의 2 networks (N1, N2) - 5 segments (3 x N1, 2 x N2) - 2 개의 protocols (DP and MPI) - PLC/DCS 는전기적으로완전분리 - addresses 중복 OK (3 and 4 별도네트워크 ) ProfiTrace OE - 1 Head Station - 3 x 2 Channel repeaters LAN/WAN N1 - DP 1,5 Mbps 200m N2 - MPI 187,5 kbps 1000 m N1 200 m 3 4 N2 1000 m 3 4 N1 200 m 5 6 7 28

사례 : 여러네트워크감시 (2) Info: 안전펜스내에사람이들어갈필요가없이네트워크점검 사람투입으로인한설비정지가없음. Network 1 ProfiTrace OE Network 2 Product LAN/WAN Network 3 Network 4 Production cell with PROFIsafe 29

자동차제조라인 ( 안전망이있는..) 안전망에지장을주지않고원격으로감시하므로안전구역침범으로인한설비정지를방지항수있습니다. 31

광산 (Mining ) 거리상, 유해가스, 들어갈수없는곳의프로피버스감시를현재의사무실에서가능합니다. DTM 기술로기기는파라메터설정이나진단기능을수용할수있습니다. 32

크레인 (Crane) 제어 접근할수없는구역이므로기술자가 Main Floor 에서 PROFIBUS 의상태를원격으로감시하고있습니다. 33

해양 Offshore 위성인터넷통신으로모든 PROFIBUS 네트워크가원격으로감시됩니다. 34

Logistics COMbricks 고속제어의응용에도적합합니다. 전문가가측정진단을위해설비에 touch 할필요가없습니다. Technical Presentation 10 July 2012 35

교통관제 (Traffic control) 거리가멀고다운타임 (downtime) 관리가중요한교통관제시스템에서는 COMbricks 가완벽한해결책입니다. 36

버스문제시즉각알림기능 Relay- 나 digital output modules 의 configuration 에의해서 bus 문제시즉각알림 ; bus voltage too low, retries, syncs, master lost, diagnostics, etc. Repeaters I/O Also direct ON/OFF control (manual and timer). Head Stations 에이미 1 개 configurable relay 포함 Syncs Lost Diagnostics Bus voltage low Retries 4 Segment 1 2 3 Segment 2 24 55 83 Power switches, Hold switches, Indicators, Backup systems, Device I/O, Doors, LED towers, etc. 37

전세계어디에서나여러대의 PCs/laptops/phones 에의한감시 Monitoring 4 networks Monitoring 4 networks 여러대의 PC 로어느곳에서나모든 COMbricks 시스템에 Access Monitoring 4 networks 38

39

40

Scope Module 적용시!! 41

Scope Module 적용시!! 42

별도의 SOFTWARE 설치없이단순한 web browser 로해결 43

ProfiTrace versus COMbricks 비교 ProfiTrace ( 현장유지보수용 ) COMbricks ( 관리감시 ) USB (power supply) 휴대형 오실로스코프 / 바그래프 마스터기능 (ProfiCptain) 트리거 & 필터 대용량기록 이더넷 / 인터넷 고정영구설치 다중네트워크관리감시 다중접근 ( IP 에의한 ) 이메일 / 로그기록 웹서버 보고서기능 고속 44

광모듈 (Fiber Optic) PHONE :, FAX : 2644 E-mail: 광모듈 (Fiber Optic)

COMbricks fiber optic module offers... 장거리전송 (3km between 2 couplers - G 62.5/125) 기기간에 Galvanic isolation 모든속도 (9.6 kbps - 12 Mbps) 자동감지 Point to point-, redundant-, bus-, star,- and hub topologies 인터넷에서 ProfiTrace 버스감시 Communication path for all PROFIBUS protocols Communication path for CommDTM to copper segments 46

Fiber Optic topologies 3 km 3 km Point-to-point with split up over the same or different networks 3 km Point-to-point in a hub topology Mix of topologies and interfaces in the same or different networks Point-to-point (redundant) 3 km 3 km 3 km Point-to-point bus structure 47

Wiring fiber optic modules (Bus) 3 km 3 km Always cross the Input and Output wires 48

Wiring fiber optic (redundancy) 3 km 3 km 49

Delay times FO Cable delay = 5μ Cable length Baudrate Example: 1.5 Mbps, 3 km FO cable delay = 5μ 3 1.5M = 22.5 Tbit 3 km Tdelay 52.2 Tbit 1 km Tdelay 22.2 Tbit Tdelay = (FO cable delay + (2 Module delay)) 2 Continued example: 1.5 Mbps, 22.5 Tbit Tdelay = (22.5 + (2 1.8)) 2 = 52.2 Tbit This is between 2 modules! More calculations have to be done when more modules are involved. The total delay for the entire network has to be added to the Slottime setting in the busparameters of the master. backplane backplane backplane 50

총비용의관점에서.. 초기투자및기동 유지보수비용 운전비용 설비 유지보수비용의절감을도모하자.. 51

유지보수의전형적인어려움 숙련된기술자의부족 광역적으로프로젝트는모두위탁하지만관리는 1곳에서이루어짐 공정및공장의무인화추세 고장시간에대한압박 기계의수명연장 Logging, tracking and tracing 52

설비고장..(Break downs) Capacity loss profit plant limit company approach break even disturbance 여분의용량 partial breakdown breakdown ProfiTrace 는고장의발견에아주유용한 Tool 이다. 그러나.. 현장에속히달려가야한다. 수집된정보의분석을위해그자리에기술자가있어야한다. 고장에예고가없다. Time 53

개선을위한항시적감시기구 * end-user 가원하는 2 nd tool 이란 설비의상태를고정적으로항시감시 설비도입시에포함될수있을것 문제가일어나기전에경고를알수있으면.. 이더넷이나인터넷으로손쉽게.. PC연결이고정되지않을것 ( 어디에서나볼수있을것 ) Operating system 에구애됨없이.. 현장에전문가없이도발견 -- no need an expert on-site 54

LinkedIN Group SIGN UP TO GET THE LATEST INFO 55

PHONE :, FAX : 2644 E-mail: COMbricks Networking, Monitoring and Control