SF6 GAS INSULATED Pad Mounted Load Break Switch Technology SPS series Pad Mount type for underground line Rating 5.8kV 6A 5/6Hz Line up 4 Way - Automa

Similar documents
<BACEBDBAC5CD20BAEAB7CEBCC52D A2DC3D6C1BE2D312D E6169>

5. Kapitel URE neu

DC Link Application DC Link capacitor can be universally used for the assembly of low inductance DC buffer circuits and DC filtering, smoothing. They

歯동작원리.PDF

Microsoft Word - SRA-Series Manual.doc

Coriolis.hwp

untitled

대경테크종합카탈로그

INDUCTION MOTOR 표지.gul

DIB-100_K(90x120)

REVERSIBLE MOTOR 표지.gul

< C6AFC1FD28B1C7C7F5C1DF292E687770>

PowerChute Personal Edition v3.1.0 에이전트 사용 설명서

SURGE PROTECTIVE DEVICE 전원 전원 전원 +E +E +N+E

CD-6208_SM(new)

PD-659_SM(new)

02 Reihe bis 750 bar GB-9.03

(Table of Contents) 2 (Specifications) 3 ~ 10 (Introduction) 11 (Storage Bins) 11 (Legs) 11 (Important Operating Requirements) 11 (Location Selection)

歯AG-MX70P한글매뉴얼.PDF

?뗡뀶?믟뀱?솽꼶?듄꼮??

GLHPS-D

Microsoft Word - Installation and User Manual_CMD V2.2_.doc


歯Trap관련.PDF

- 2 -

72129o

PowerPoint 프레젠테이션

Microsoft PowerPoint - ch03ysk2012.ppt [호환 모드]


acdc EQ 충전기.hwp

(specifications) 3 ~ 10 (introduction) 11 (storage bin) 11 (legs) 11 (important operating requirements) 11 (location selection) 12 (storage bin) 12 (i

Å©·¹Àγ»Áö20p

WOMA Pumps - Z Line

#Ȳ¿ë¼®

TAE YOUNG Electronics 당사는 1987년 설립되어 직류전원장치를 전문 제조하는 업체로서, 국내 인터넷서비스 업체인 두루넷과 하나로텔레콤 등을 거쳐 현재의 SK브로드밴드, LG유플러스의 전원아답터 공급업체로서 오랜 시간 함께 성장하였습니다. 또한 자체 브

나사식볼밸브.indd

Vertical Probe Card Technology Pin Technology 1) Probe Pin Testable Pitch:03 (Matrix) Minimum Pin Length:2.67 High Speed Test Application:Test Socket

hwp

歯3이화진

RFID USN_K_100107

#KM560

7 LAMPS For use on a flat surface of a type 1 enclosure File No. E Pilot Lamp File No. E Type Classification Diagram - BULB Type Part Mate

NX_Sale_Presentation(Korean)


04-다시_고속철도61~80p

ISO17025.PDF

D101351X0KR_May17

SW_faq2000번역.PDF

PowerPoint 프레젠테이션

Microsoft Word - KSR2012A132.doc

#KM-235(110222)


DE1-SoC Board

¹Ìµå¹Ì3Â÷Àμâ

untitled

,,,,,, (41) ( e f f e c t ), ( c u r r e n t ) ( p o t e n t i a l difference),, ( r e s i s t a n c e ) 2,,,,,,,, (41), (42) (42) ( 41) (Ohm s law),

BC6HP Korean.ai

Microsoft Power Point 2002

??뀁?뀁?

BC6DX Korean.ai

solution map_....


CD-RW_Advanced.PDF

Genie Industries http//wwwgenieliftcom Copyright 00 Genie Industries 1, 00 1, Genie Genie Industri

전자교탁 사양서.hwp


Output file

Microsoft Word - FS_ZigBee_Manual_V1.3.docx

ETC Electrolytic Technologies Corporation Electrolytic Technologies Corporation (ETC) (High Strength Sodium Hypochlorite). ETC.,. ETC,,. - (Cl2) (NaOH

<4D F736F F F696E74202D2028B9DFC7A5BABB2920C5C2BEE7B1A420B8F0B5E220C8BFC0B220BDC7C1F520BDC3BDBAC5DB5FC7D1B1B94E4920C0B1B5BFBFF85F F726C F72756D>

동아내지1수(A~E)-수정2

CD-6208_SM(new)

경제성과안정성이높은차단기 / VCB IEC 신규격개정에따른한전의교류차단기표준규격 (ES150) 의개정및적용 (2004 년 10 월 ) 으로인해한전수화력발전소용으로개발된제품으로, 차단성능향상및안전성과신뢰성을확보한국내최초의대용량 (40~50kA) 발전소용 VCB 시리즈를완

- 이 문서는 삼성전자의 기술 자산으로 승인자만이 사용할 수 있습니다 Part Picture Description 5. R emove the memory by pushing the fixed-tap out and Remove the WLAN Antenna. 6. INS

ez-shv manual

내지-2도뻂

영상5월_펼침면

GD-SERISE / GS-SERISE DESCRIPTION GD / GS series pneumatic actuator are designed & developed with new concept for the next generation. GD / GS series

사용시 기본적인 주의사항 경고 : 전기 기구를 사용할 때는 다음의 기본적인 주의 사항을 반드시 유의하여야 합니다..제품을 사용하기 전에 반드시 사용법을 정독하십시오. 2.물과 가까운 곳, 욕실이나 부엌 그리고 수영장 같은 곳에서 제품을 사용하지 마십시오. 3.이 제품은

.....pdf

untitled

VZ94-한글매뉴얼

F-INDEX(9).pdf

Smart-UPS On-Line 230 V UPS apc.com/kr

Preliminary spec(K93,K62_Chip_081118).xls

CFP 제작(0113)

소개.PDF

1. Features IR-Compact non-contact infrared thermometer measures the infrared wavelength emitted from the target spot and converts it to standard curr

X-VA-MT3809G-MT3810G-kor

Slide 1

MAX+plus II Getting Started - 무작정따라하기

전기정보 11월(내지).qxp

À̵¿·Îº¿ÀÇ ÀÎÅͳݱâ¹Ý ¿ø°ÝÁ¦¾î½Ã ½Ã°£Áö¿¬¿¡_.hwp

歯174구경회.PDF

歯4.PDF

<453A5C736F6E67616D656E675CBBE7BFEBBCB3B8EDBCAD26C4ABB4D9B7CF2E2E2E>

ez-md+_manual01

example code are examined in this stage The low pressure pressurizer reactor trip module of the Plant Protection System was programmed as subject for

THE JOURNAL OF KOREAN INSTITUTE OF ELECTROMAGNETIC ENGINEERING AND SCIENCE Jun.; 29(6),

BSC Discussion 1

Transcription:

The only choice of, Thriving together with customers. SF6 GAS INSULATED Pad Mounted Load Break Switch

SF6 GAS INSULATED Pad Mounted Load Break Switch Technology SPS series Pad Mount type for underground line Rating 5.8kV 6A 5/6Hz Line up 4 Way - Automatic type & Control unit Overview SPS series is puffer interrupting pad mounted, fully deadfront switchgear for underground system up to 5.8kV 6A, enclosed in stainless steel body full of SF6 gas insulation media. It incorporates grounding switches in every way to provide added safety and faster working. Pad mounted load break switch has been fully certified in accordance with IEC 665- and ANSI/IEEE 7.7 to meet and exceed customer specifications. Product Highlights Design for SCADA system(automatic type only) Integrated capacitive voltage sensors, CT s and internal power supply makes this switch easy to be installed in SCADA system. SF6 Gas Insulation Media which is enclosed in stainless steel body sealed for life and maintenance free with less than.% leakage rate per year, showing normal insulation and interruption performance even at an atmospheric gas pressure. Unique and field proven puffer and heavy duty tulip shaped contacts made of arc resistant Cu-W tip ensures short arc-extinguishing time of less than.5 cycles and more than times load current capacity. Internal power source through integrated capacitor-potential transformer combination for the control circuit s power.

The only choice of Thriving together with customers., Technology SPS series Pad Mount type for underground line Rating 5.8kV 6A 5/6Hz Line up 4 Way - Manual type Way Manual type Three phase group-operated mechanism offers regular close-open speed regardless operating speed and method(manual or electrical). Front ground circuit bushings offer easy cable testing. Deadfront design and mechanical interlock between main and earth switch provides a high level of safety and efficient maintenance. Closed state of main circuit switch interlocks grounding circuit switch, and also closed state of grounding circuit switch interlocks main circuit switch in every ways. The switch is designed to be mounted on the concrete pad. The switch offers following features ; Maintenance free Light weight and easy installation Measuring, status monitoring and control Safety devices(low pressure interlocking, pressure relief, pressure gage, locking)

Control Unit for Pad mounted Load Break Switch Source Input : /VAC Output : 4VDC Control Local / Remote 4 Overview Control unit has been designed to work with the SPS-6-4A type pad mounted load break switch. It can communicate with SCADA or DAS via RTU and MODEM. Product Highlights Control cubicle mounted and fixed on the top of the pad mounted load break switch is fabricated from stainless steel of not less than mm thickness. Electrical surge protection and impedance-matching control circuit board is constructed and tested to meet the latest applicable standards of IEC 655 and ANSI/IEEE 7.9.. Lead acid battery provides DC power to the local control circuit board in case of AC power source failure. The battery has sufficient capacity to sustain more than 4 hour operation while AC power supply s failure, with a minimum lifetime of years. And the battery is automatically disconnected from the control circuit when the battery voltage falls below a preset value in order to prevent deep battery discharging. It is available to select one power source system among following alternatives for the control circuit s power. The internal power source system consists of integrated capacitor and potential transformer. The external power source system means external potential transformer supplying or VAC power to the control circuit. Power Supply AC power supply from power source inputs VAC or VAC to the control unit, and DC power 4VDC is parallel connected with battery and the other part of the control circuit. Battery charger has trickle charging mode with lower current and protecting function of over charging. Battery : lead acid battery Ah and 4VDC input toward control circuit. Local Control Circuit CT signal and voltage signal output from each phase of the pad mounted load break switch. Battery testing to check the battery voltage on load condition & battery charger. Local/Remote control selection switch. Local close/open button. Separate open(green) and close(red) status LED. RTU for remote control (option) The RTU is developed to communicate with center control, to measure the electrical quantity, and to get the fault information. It is using the DSP for calculation and micro-processor for other tasks. It can measure the V, I, VA, W, VAR and power factor, detect the fault current and memory the wave form for further analysis.

The only choice of Thriving together with customers., Rating 4 Way X 4 Switch Descriptions Type Code Manual type Automatic type Manual type SPS-6-4M SPS-6-4A SPS-6-M Rated Voltage 5.8kV Rated Continuous Current 6A Rated Short-time current.5ka(rms).sec (.5kAp) Rated Short Circuit Making Current.5kAp. 5 times Rated Current Switching Capacity WXS Load-current times CO / (5%) times Loop-current times Cable charging 5A times / (%) 7.5A times Line charging.5a times Excitation current A times No-load current 5, times CO /, times CG Rated Control Voltage - Ø VAC/4VDC Rated Power frequency withstand Voltage 6kV/min. Lightning Impulse Withstand Voltage 5kV(. x 5 ) SF6 gas Filling Pressure.7 kgf/cm.g(at ) Relief pressure ~ 4 kgf/cm.g - Environmental Ambient temperature -5 ~ 4 (Max. 75 ) Altitude Below,m Installation Outdoor pad mount for underground line / Horizontal Applied Standard IEC 665- ANSI/IEEE 7.7 5

Outline Drawing 4W X 4S (Automatic type) Control Box T( ), Pressure(MPa) Curve 5.8kV 가스절연부하 개폐기(지용) CONTROLLER 식 : SPS-4A 정격제어전압 : D~7V A87~4V 량 : 75KG 제 조 년 월 : 9. 6 조작 전원 최대 용량 : 정전시 5회 5회이상 회 로 도 FRTU Moving Lug 전원공통 S S S S4 PT 78.5 Name Plate SF6 GAS 온도-압력 특성 곡선 압력MPa.4.5 안전막 동작압력.~.4MPa..5. 4.5...9.8 정격가스 압력.7.6.5 잠금 압력 범위(. ~.5MPa) 최소보증압(.MPa).4... 적색 녹색 적색 적색 녹색 녹색 Pressure Gauge 적색 적색 녹색 녹색 5-5 -..5 4 psi -76 cmhg 적색 녹색 녹색 적색 녹색 -5. 4-5 -5 온도( C) 주의 사항. 잠금 압력 범위에서는 GAS를 충진한후 개폐기를 조작할 것.. GAS는 온도에 따라 표준 동작압력의 ±5%이내로 주입할 것. Main Bushing Pressure Sensor 5.8kV 가스절연부하개폐기(지용) Gas Stopple -.5 적색 SPS- 4A.7 MPa 가스 방출 압력 정격 전압 5.8kV 최저보증가스압력. MPa 구매오더번호 정격충격내전압 5kV 절연물의 종류 SF6 GAS 정격연속전류 6A 가 스 량.95 kg 정격부하개폐전류 6A 58 kg 식 정격 가스 압력 량 ES 정격단시간전류.5kA(rms)초 제 조 번 호 SPS- 4A- 정격투입전류.5kA(peak),5회 제 조 년 월.....~.4 MPa ES ES A C ES4 MPa WIKA PT Bushing A A C C 69 Counter Phase Indicator Earth Bushing Phase Sticker Earth Terminal Rupture Cover 44 45 4W X 4S (Manual type) 4W X 4S - M Name Plate T( ), Pressure(MPa) Curve Moving Lug SF6 GAS 온도-압력 특성 곡선 압력MPa.4.5 안전막 동작압력.~.4MPa..5. 4.5...9 정격가스 압력.8.7.6.5 잠금 압력 범위(. ~.5MPa) 최소보증압(.MPa).4... 녹색 Pressure Gauge 적색 적색 녹색 녹색 적색 적색 녹색 녹색 적색 적색 녹색 녹색 -..5 Gas Stopple 4 psi -76 cmhg. MPa -5. 4-5 -5 온도( C) 주의 사항. 잠금 압력 범위에서는 GAS를 충진한후 개폐기를 조작할 것.. GAS는 온도에 따라 표준 동작압력의 ±5%이내로 주입할 것. Main Bushing 5.8kV 가스절연부하개폐기(지용) 5 WIKA 녹색 A A C C SPS- 4A.7 MPa 가스 방출 압력 정격 전압 5.8kV 최저보증가스압력. MPa 구매오더번호 정격충격내전압 5kV 절연물의 종류 SF6 GAS 6A 가 스 량.95 kg 47 kg 적색 -.5-5 Counter 식 정격연속전류 정격부하개폐전류 6A 정격 가스 압력 량 정격단시간전류.5kA(rms)초 제 조 번 호 SPS- 4A- 정격투입전류.5kA(peak),5회 제 조 년 월... ES ES.~.4 MPa ES A C ES4 755.5 적색 Phase Indicator Earth Bushing Phase Sticker Earth Terminal Rupture Cover 44 6 45

The only choice of Thriving together with customers., W X S (Manual type) Name Plate Moving Lug T( ), Pressure(MPa) Curve SF6 GAS 온도-압력 특성 곡선 압력MPa.4.5. 안전막 동작압력.~.4MPa.5..5...9.8 정격가스 압력.7.6.5.4 잠금 압력 범위(. ~.5MPa). 최소보증압(.MPa)... 적색 적색 적색 적색 적색 적색 녹색 녹색 녹색 녹색 녹색 녹색 -5 -..5 4 psi -76 cmhg -5 4 온도( C) 주의 사항. 잠금 압력 범위에서는 GAS를 충진한후 개폐기를 조작할 것.. GAS는 온도에 따라 표준 동작압력의 ±5%이내로 주입할 것..7 MPa 가스 방출 압력 5.8kV 최저보증가스압력. MPa 구매오더번호 5kV 절연물의 종류 SF6 GAS 회로도 6A 가 스 량.7 kg 6A 4 kg Gas Stopple. SPS- M 정격 전압 정격충격내전압 식 정격연속전류 정격부하개폐전류 정격 가스 압력 량 ES Main Bushing 정격단시간전류.5kA(rms)초 제 조 번 호 SPS- M- 정격투입전류.5kA(peak),5회 제 조 년 월....~.4 MPa ES ES A C 755.5 Counter 5-5 5.8kV 가스절연부하개폐기(지용) Phase Indicator -.5-5 MPa WIKA Pressure Gauge A A C C Earth Bushing Phase Sticker Earth Terminal 99 Rupture Cover 45 Installation Type Test P.T Cabinet MODEM & TR 설치공간 5.8kV 가스절연부하개폐기(지용) 식: SPS-4A 정격제어전압: DC 4V 량: kg 제 조 년 월:.. 제 조 번 호: 조작 전원 최대 용량 정전시 5회, 5회 이상 회 로 도 FRTU CONTROLLER 전원공통S S S S4 MODEM & TR 설치공간 SF6 가스 온도 - 압력 특성표 압력(kg/cm ) 압력(psi.G) 4 4 정격가스 압력.7 9 8 7 6 5 잠금 압력 범위 4. -5-5 4 온도( C) 적색 녹색 적색 적색 녹색 녹색 적색 적색 녹색 녹색 적색 적색 녹색 녹색 적색 주의 사항. 잠금 압력 범위에서는 GAS를 충진한후 개폐기를 조작할 것.. GAS는 온도에 따라 표준 동작압력의 ±5%이내로 주입할 것. 녹색 5.8kV 가스절연부하개폐기(지용).7 kg/cm 정격 전압 5.8kV 최저보증가스압력.4 kg/cm 정격충격내전압 5kV 절연물의 종류 SF6 GAS GLBS Main 식 SPS- 4A 정격연속전류 6A 정격부하개폐전류 6A 정격 가스 압력 kg 가 스 량 kg 량 정격단시간전류.5kA(rms)초 제조번호 정격투입전류.5kA(peak),5회 제 조 년 월... ES ES ES C A ES4 C A Concrete Pad Block Earth Ground Level 4 S/W Connect Cable 5 Main Cable 4 7 Test results are within the scopes accredited by Korea Laboratory Accreditation Scheme, which signed the International Laboratory Accreditation Cooperation Mutual Recognition Arrangement. 7

www.sns.co.kr S&S maintaining advanced technology and continuous innovation is challenging the unlimited possibility. Distributed by 65-, Suchon-ri, Jangan-myon, Hwaseong city, Gyeonggi-do, 445-944 R.o.Korea. Phone : 8--5-67~9 Fax : 8--5-69~4 http://www.sns.co.kr Nov. 9.