신청기관 ( 인 ) Applicant : 스미스테크 : SMITHTECH 주소 ( 한글 ) : 경기도파주시탄현면한산로 36 Address (Engl.) : 36, Hansan-ro, Tanhyeon-myeon, Paju-si, Gyeonggi-do, Korea 발행면수 (Page) : 1 of 10 시료명세 (Sample Description) 제품명 / 형식 : SHIELDING BAG (Name/Type of Product) 재질 (Name of Material) 시료고유번호 (Sample ID No.) : 시료에대한상세한정보는아래와같음 (The following submitted sample(s) said to be) : VMPET + LLDPE (VMPET + LLDPE) : RT1R-S2484 (RT1R-S2484) 제품생산자 / 공급자 : 스미스테크 (Manufacturer/Vendor) (SMITHTECH) 시료접수일자 : 201. 0. 27. (Sample received) (May 27, 201) 시험일자 : 201. 0. 27. ~ 201. 0. 29. (Testing Date) (May 27, 201 ~ May 29, 201) 시험유형 (Test Type) 시험방법 (Test Method) 시험결과 (Test Result) : RoHS 화학분석 (RoHS wet chemical analysis) : 이시험성적서의다음페이지첨부 (Please see the following page) : 이시험성적서의다음페이지첨부 (Please see the following page) 비고 (Notes) : 1. 이시험성적서는제시된시료및시료명으로시험한결과로서유사대상시료에적용할수없음. (The test results presented in this report relate only to the object tested.) 2. 이시험성적서는승인없이복사사용을금함. (This report shall not be reproduced except in full without the written approval of the testing laboratory.) 승인자 (Approved by) 권한자 (Authorized by) 장준용 / 기술책임자 (Jade Jang / Lab. Technical Manager) 박병옥 / 소장 (Bo Park / Lab. General Manager) Authenticity check
발행면수 (Page) : 2 of 10 시험항목 (Test Item) 카드뮴 (Cadmium, Cd) 납 (Lead, Pb) 수은 (Mercury, Hg) 6 가크롬 (Hexavalent Chromium, Cr 6+ ) (For non-metal) Tested by : Chanoh Kim, Jooyeon Lee 단위 (Unit) 분석방법 (Test Method) IEC 62321- Edition 1.0 : 2013, by acid digestion and determined by ICP-OES IEC 62321- Edition 1.0 : 2013, by acid digestion and determined by ICP-OES IEC 62321-4 Edition 1.0 : 2013, by acid digestion and determined by ICP-OES IEC 62321 Edition 1.0 : 2008, by alkaline digestion and determined by UV-VIS Spectrophotometer 검출한계 (MDL) 시험결과 (Result) 0. 2 1 Notes : = ppm = parts per million ( 함량표시 : 백만분의일 ) < = Less than ( 결과값이하 ) = Not detected (< MDL, 미검출 검출한계이하 ) MDL = Method detection limit ( 검출한계 )
발행면수 (Page) : 3 of 10 시험항목 (Test Item) Tested by : Hyoji Lee 단위 (Unit) 폴리브롬화비페닐 (Polybrominated Biphenyls, PBBs) 모노브로모비페닐 (MonoBB) 분석방법 (Test Method) 검출한계 (MDL) 시험결과 (Result) 다이브로모비페닐 (DiBB) 트라이브로모비페닐 (TriBB) 테트라브로모비페닐 (TertaBB) 펜타브로모비페닐 (PentaBB) 헥사브로모비페닐 (HexaBB) 헵타브로모비페닐 (HeptaBB) IEC 62321 Edition 1.0 : 2008, by solvent extraction and determined by GC/MS 옥타브로모비페닐 (OctaBB) 노나브로모비페닐 (NonaBB) 데카브로모비페닐 (DecaBB) 폴리브롬화디페닐에테르 (Polybrominated Diphenyl Ethers, PBDEs) 모노브로모디페닐에테르 (MonoBDE) 다이브로모디페닐에테르 (DiBDE) 트라이브로모디페닐에테르 (TriBDE) 테트라브로모디페닐에테르 (TetraBDE) 펜타브로모디페닐에테르 (PentaBDE) 헥사브로모디페닐에테르 (HexaBDE) 헵타브로모디페닐에테르 (HeptaBDE) IEC 62321 Edition 1.0 : 2008, by solvent extraction and determined by GC/MS 옥타브로모디페닐에테르 (OctaBDE) 노나브로모디페닐에테르 (NonaBDE) 데카브로모디페닐에테르 (DecaBDE) Notes : = ppm = parts per million ( 함량표시 : 백만분의일 ) < = Less than ( 결과값이하 ) = Not detected (< MDL, 미검출 검출한계이하 ) MDL = Method detection limit ( 검출한계 )
발행면수 (Page) : 4 of 10 시험항목 (Test Item) 브롬 (Bromine, Br) 염소 (Chlorine, Cl) 안티몬 (Antimony, Sb) 디부틸프탈레이트 (Dibutyl phthalate, DBP) 디에틸헥실프탈레이트 (Di-(2-ethylhexyl) phthalate, DEHP) 벤질부틸프탈레이트 (Benzyl butyl phthalate, BBP) 퍼플루오로옥타노익에시드 (Perfluorooctanoic acid, PFOA) 퍼플루오로옥탄설포네이트 (Perfluorooctane sulfonate, PFOS) 단위 (Unit) Tested by : Dahye Lim, Yeonju Lee, Misun Lee, Shirley Park 분석방법 (Test Method) EN 1482, by oxygen combustion with bomb and determined by IC EN 1482, by oxygen combustion with bomb and determined by IC US EPA 302, by acid digestion and determined by ICP-OES US EPA 8061A, by solvent extraction and determined by GC/MS US EPA 8061A, by solvent extraction and determined by GC/MS US EPA 8061A, by solvent extraction and determined by GC/MS US EPA 30C & 8321B, by ultrasonic extraction and determined by LC/MS/MS US EPA 30C & 8321B, by ultrasonic extraction and determined by LC/MS/MS 검출한계 (MDL) 시험결과 (Result) 30 30 2 30 0 0 0 0.1 0.1 Notes : = ppm = parts per million ( 함량표시 : 백만분의일 ) < = Less than ( 결과값이하 ) = Not detected (< MDL, 미검출 검출한계이하 ) MDL = Method detection limit ( 검출한계 )
발행면수 (Page) : of 10 * 시료접수시시료상태 : (View of sample as received)
발행면수 (Page) : 6 of 10 Flow Chart (IEC 62321 Edition 1.0) Receipt Sampling/ Grinding or Cutting Pb, Cd, Hg Cr 6+ PBBs /PBDEs Polymers / Electronics For different material, digest the sample with appropriate acid *1 Confirm the tested samples are totally dissolved *2 Weigh sample and add alkaline solution Definite temperature extraction Cool and filter the extract Weigh sample and add organic solvent Soxhlet extraction or solvent extraction Make up with deionized water Make up with deionized water and add diphenylcarbazide solution Concentrate the extract and make up with organic solvent Analyzed by ICP-OES Analyzed by UV-VIS Analyzed by GC-MS Remarks : *1 : List of appropriate acid: Material Acid added for digestion Polymers HNO 3, HCl, HF, H 2O 2, H 3BO 3 Metals HNO 3, HCl, HF Electronics HNO 3, HCl, H 2O 2, HBF 4 *2 : The samples were dissolved totally by pre-conditioning method according to above flow chart.
발행면수 (Page) : 7 of 10 Flow Chart (Halogen) Receipt Sample preparation Sample weighing Bomb preparation Oxygen bomb combustion Absorption solvent preparation of absorption solution Cooling, for 1hr Collection of halides make up Vol. 100mL Analyzed by IC
발행면수 (Page) : 8 of 10 Flow Chart (Metal Testing) Receipt Sample preparation Sample measurement NO Microwave digestion with HNO 3 / HCl / HF Total digestion YES Analyzed by ICP-OES ** 비고 : 이샘플은위의흐름도에따른전처리방법에의해완전용해되었음. ( The samples were dissolved totally by pre-conditioning method according to above flow chart.)
발행면수 (Page) : 9 of 10 Flow Chart (Phthalates) Receipt Sample preparation Extraction Concentration Clean-up Concentration Analyzed by GC-MS
발행면수 (Page) : 10 of 10 Flow Chart (PFOS, PFOA) Receipt Sample preparation Loading in a vial Methanol loading Ultrasonication Filtering & Cleaning Make up (Methanol) Analyzed by LC/MS/MS ***** End of ***** This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct.