Microsoft PowerPoint - Powertrain_Actuator

Similar documents
Microsoft PowerPoint - Powertrain_Sensor

02 Reihe bis 750 bar GB-9.03

E010 CYLINDER BLOCK GROUP (0 01) 76

한국콘베어-AP8p

<BACEBDBAC5CD20BAEAB7CEBCC52D A2DC3D6C1BE2D312D E6169>

대형디젤기관의 Cooled-EGR제어 시스템 개발에 관한 실험적 연구

(Table of Contents) 2 (Specifications) 3 ~ 10 (Introduction) 11 (Storage Bins) 11 (Legs) 11 (Important Operating Requirements) 11 (Location Selection)

Coriolis.hwp

Vertical Probe Card Technology Pin Technology 1) Probe Pin Testable Pitch:03 (Matrix) Minimum Pin Length:2.67 High Speed Test Application:Test Socket

(specifications) 3 ~ 10 (introduction) 11 (storage bin) 11 (legs) 11 (important operating requirements) 11 (location selection) 12 (storage bin) 12 (i

3장 ION M74 자동변속기.ppt

< C6AFC1FD28B1C7C7F5C1DF292E687770>

WOMA Pumps - Z Line

REVERSIBLE MOTOR 표지.gul

INDUCTION MOTOR 표지.gul

DC Link Application DC Link capacitor can be universally used for the assembly of low inductance DC buffer circuits and DC filtering, smoothing. They

Using Material of High Quality! ST 044N LYOUT O TH HIN Ls: Stroke Lp: Loop Length Lf: Loop Projection Hs: Safe Space (Dimensions in mm) ending radius

Ceramic Innovation `

B-3 B-4 HDV B-8 B-37 B-39 3S1A B-40 3S2A B-42 3S3A B-44 3S4A B-45 B-11 B-15 S1A B-16 K2A B-20 K3A B-24 S3A B-27 S4A B-30 S5A B-33 HPV5-6, HPV5-8 B-78

³»ÁöÀÛ¾÷-~89š

ePapyrus PDF Document

untitled

WIDIN - Toolholding Catalogue.pdf

GD-SERISE / GS-SERISE DESCRIPTION GD / GS series pneumatic actuator are designed & developed with new concept for the next generation. GD / GS series

GLHPS-D


DBPIA-NURIMEDIA

歯국문-Heatran소개자료1111.PDF

<4D F736F F F696E74202D20454D49A3AF454D43BAEDB7CEBCC52EBBEABEF7BFEBC6F7C7D428BBEFC8ADC0FCC0DA >

歯Trap관련.PDF

2

.....pdf

RC /07.12 RC / /6 2 3 / CA-08A-2N 2 CA-10A-2N 2 CA-12A-2N 2 CA-16A-2N 2 CA-20A-2N CA-08A-3N 4 CA-10A-3N 4 CA-12A-3N

歯coolingtower개요_1_.PDF

- 2 -

CFP 제작(0113)

1. Features IR-Compact non-contact infrared thermometer measures the infrared wavelength emitted from the target spot and converts it to standard curr

Microsoft Word - Installation and User Manual_CMD V2.2_.doc

LYOUT O TH HIN (Dimensions in mm) ending radius R Lp Lf H ORDRING RKT TYP (ree nd racket)

Elix 3 Elix 5 Elix 10 RiOs 3 RiOs 5 RiOs 8 RiOs 16!.. MILLIPORE

PJTROHMPCJPS.hwp

13장_

12하이브리드브로셔-국문

대경테크종합카탈로그

Microsoft PowerPoint - ch03ysk2012.ppt [호환 모드]

D40-T00A CLUTCH GROUP D40-T0A CLUTCH LEVER GROUP DK45-T0A CLUTCH HOUSING GROUP.....

윤활유 개발 동향 및 연구 사례

歯RCM

hwp

untitled

The Top Ten Moulding Problems

MANN+HUMMEL

歯기구학

17(2)-00(268).fm

5. Kapitel URE neu


COLUMN, BED, SADDLE The column is of a rugged box-type construction and its ground slide ways are wide to support and guide securely the spindle head.

00.1

<453A5C736F6E67616D656E675CBBE7BFEBBCB3B8EDBCAD26C4ABB4D9B7CF2E2E2E>

untitled

전자교탁 사양서.hwp

DIB-100_K(90x120)

저작자표시 - 비영리 - 변경금지 2.0 대한민국 이용자는아래의조건을따르는경우에한하여자유롭게 이저작물을복제, 배포, 전송, 전시, 공연및방송할수있습니다. 다음과같은조건을따라야합니다 : 저작자표시. 귀하는원저작자를표시하여야합니다. 비영리. 귀하는이저작물을영리목적으로이용할

Preliminary spec(K93,K62_Chip_081118).xls

KAERI/RR-2245/2001 : 원전 주기적 안전성 평가기술 개발 : 방사선 안전성능 및 환경방사선 감시기술 개발

<C7A5C1F65FC0FCB8E95F31502E6169>

GEAR KOREA

#KM560

PowerChute Personal Edition v3.1.0 에이전트 사용 설명서

소개.PDF

Pilot Operated Regulator 1098-EGR 용도 도시가스지구정압기 (City Gate Station, Main Station) 도시가스지역정압기 (District Station) 상 공업용대유량전용정압기 ( 빌딩, 공장, 병원, 학교 ) 산업용대유량기

LCD Display

한약재품질표준화연구사업단 단삼 ( 丹參 ) Salviae Miltiorrhizae Radix 생약연구과

Z DB 6 -X V * Sandwich plate = Z Further details in clear text With pressure valve cartridges = No code = Without locating pin hole (only applies to v

한약재품질표준화연구사업단 강활 ( 羌活 ) Osterici seu Notopterygii Radix et Rhizoma 생약연구과

D101351X0KR_May17

Å©·¹Àγ»Áö20p

DBPIA-NURIMEDIA

F-INDEX(9).pdf

歯4.PDF

KM-380BL,BLB(100908)

JSI-EN-04-2E-001=LHDV.hwp

인켈(국문)pdf.pdf

특허청구의 범위 청구항 1 몸체(110)의 일측에는 테스트의 필요성에 따라 여타한 디젤 자동차(100)에서 분리시킨 상태의 분리형 커먼레일 인젝트(110)를 고정할 수 있는 분리형 인젝터 고정부(20)가 구비되고, 그 고정부(20)의 하측에는 분리형 커먼 레일 인젝터(

Microsoft PowerPoint - Freebairn, John_ppt


1508 고려 카달록

Parts List

05-1Ưº°±âȹ


( Full Automatic Printer ) 작용업종 : Tube Light ( 형광등 1.2m / 2.4m) 가로등조명. 인테리어산업용조명 Loader 1.2m Stencil Solder LED LD812V Reflow 8 to 10 Hot Air Convecti

나사식볼밸브.indd

X-VA-MT3809G-MT3810G-kor

Gray level 변환 및 Arithmetic 연산을 사용한 영상 개선

목차 생활용품오염물질방출시험및방출특성연구 (IV) - 전기 전자제품방출오염물질권고기준 ( 안 ) 도출 - ⅰ ⅱ ⅲ Abstract ⅳ 환경기반연구부생활환경연구과 Ⅰ,,,,,, 2010 Ⅱ i

#KM-350AB..

# KM

D103198X0KR_Jul18 Korean

Microsoft PowerPoint - User Manual pptx

IZMAC 의 Shock Absorber 는수백만번을작동할수있도록설계되어있으며다음과같은사 항을고려하여주시면긴수명을보장합니다. 1) 용량선정이적정하게되었는지확인하십시오. 2) 충돌물체와 Shock Absorber 의설치각도가일치한가를확인하십시오. Piston Rod 의중

Transcription:

Injector Precise fuel metering Wide dynamic operation range Excellent linearity of low dynamic flow Fast response MPI injector is a type of solenoid valve which injects fuel into the intake port with precise fuel amount and generates optimal spray characteristics according to the operating conditions. Excellent spray and atomization performance Low leakage, Low noise Long endurance Operation Pressure 3~6 bar (Max. 10 bar) Operating temperature range -40 ~ 140 Fuel Gasoline, E100, M15 (Worldwide standard fuel) Flow rate (Static) 106 ~ 410 ± 4% g/min (@ 3 bar) Hydraulic Leakage 0.8 mm 3 /min (@ 3 bar) Spray angle / Targeting Variable spray hole diameter and spray angle Droplet size (SMD * ) 80 µm (@ 12 holes) 180 µm (@ 4 holes) *SMD : Sauter Mean Diameter

LPI Injector Precise fuel metering Wide dynamic operation range Excellent linearity of low dynamic flow Fast response LPI injector is a type of solenoid valve which injects fuel into the intake port with precise fuel amount and generates optimal spray characteristics according to the operating conditions. Excellent spray and atomization performance Low leakage, Low noise Long endurance Operation Pressure 8 ~ 15 bar (max. 30 bar) Operating temperature range -40 ~ 140 Fuel LPG Flow rate (Static) 90 ~ 200 ± 4% g/min (@ 3 bar) Hydraulic Leakage 0.06 cm 3 /min (with N2 gas @ 3.8 bar) Spray angle / Targeting Variable spray hole diameter and spray angle Feeding type Side feeding

GDI Injector GDI(Gasoline Direct Injection) injector is the solenoid valve type which injects the fuel with precise amount and optimal spray characteristic according to the vehicle condition. Precise fuel metering Wide dynamic operation range Excellent linearity of low dynamic flow Fast response Optimal spray pattern & atomization Low leakage & noise Long endurance Operation Pressure 40~250 bar (Max. 317 bar) Operating temperature range -40 ~ 140 (Tip : 170 ) Fuel Gasoline, E30, M15 (Worldwide standard fuel) Flow rate 300 ~ 900 ± 5% g/min (@ 100 bar) Hydraulic Leakage 1.5 mm 3 /min (@ 100 bar) Spray angle / Targeting Variable spray hole diameter and spray angle Droplet size(smd*) 12 um (@ 250 bar) *SMD : Sauter Mean Diameter

GDI Pump GDI(Gasoline Direct Injection) Pump, that is to say the high pressure pump, compresses low pressure fuel into high pressure fuel and delivers the compressed fuel to the delivery pipe in order to directly inject it into cylinders. Stably pressurized fuel supply Isolation of external leakage Minimization of internal leakage Minimized operation noise Enhanced external shape to reduce the radiated noise System pressure up to 200 bar Flow rate up to 1.12cm 3 /cam revolution Mounting on cylinder head or adapter flange Compact size, flex fuel application Made from stainless steel Integrated pressure damper for variable feed pressure Integrated pressure relief valve Flexible customer interface concept Zero evaporation by laser welding, resistance welding (No O-ringseals)

Idle Speed Control Actuator When engine is at idling, ISCA is activated by ECU in order to maintain the target engine speed. Anti-contamination (Cleaning function) Direct mounting (Al housing prevents crack, deformation etc.) Limp home function Compact design and low cost Max. air flow rate 63 ~ 71m 3 /h Leakage air flow rate 1.0 ~ 2.3m 3 /h Operating temperature -30 ~ 120 Vibration level 40 G Limp home function applied

VCM motor VCM system makes tumble flow of inlet air for observance of emission control at engine starting and improving fuel efficiency in the mid to low load operation. VCM motor, mounted on VCM valve shaft of intake manifold, is actuated rotation of the VCM valve. Compact size, Low weight Quick response time Accurate angle control Fail-safe function (option) Operating temperature -40 ~ +140 Operating voltage 9V ~ 16V Sensor operating voltage 5±0.1V Response time 300 ms Linearity ±2% Output voltage 0 ~ 5V

Integrated VIS Actuator Integrated VIS Actuator can operate VIS(Variable Induction System) valve to change the length of the intake manifold Runner - in order to optimize power and torque across the range of engine speed operation by ECU control. Solenoid valve and vacuum actuator integrated structure Compact size, Low weight Mounting stability Operating temperature -40 ~ 140 Operating voltage Max. 9V Release voltage Max. 6V Leakage Max. 3cc/min Minimum Air Flow Rate Max. 10 l/min

Purge Control Solenoid Valve PCSV is switched on and/or off to prevent hydrocarbons discharge out of the air under certain ECU operating conditions and then the evaporated gas is carried to the intake manifold from the canister to combust. Superior Max. Flow rate Low Valve Leakage Mesh filter's built in for Preventing contamination (96 μm above) Rotatable Cover Direction : Mounting Flexibility Low Noise Design Compact Size KEV1 3.5 KEV1 5.0 KEV2 7.0 KEV3 5.0 Flow Point Q100 ( P=100mbar, τ=100%) 2.5 ±0.5 m3 /h 3.5 ±0.5 m3 /h 5.0 ±0.5 m3 /h 3.5 ±0.5 m3 /h Flow Point Qmax( P=700mbar, τ=100%) 3.5 ±0.4 m3 /h 5.0 ±0.4 m3 /h 7.0 ±0.4 m3 /h 5.0 ±0.4 m3 /h Flow Point Qlow( P=700mbar, τ=10%) 0.08~0.40 m3 /h 0.20~0.60 m3 /h 0.08~0.40 m3 /h Operating temperature -40~140 Trigger frequency Battery Supply Voltage Operating voltage 10 Hz 13.5 V 9~16 V Resistance 20.5 ±2 Ω 14.5 ±2 Ω 20.5 ±2 Ω Valve Tightness Type of vehicle using the valve 0.00132 m3 /h ( 22ml/min) Compact Midsize ~ Large HEV Midsize ~ Large

On-Off solenoid valve Installed in valve-body of Auto transmission, control the hydraulic pressure (to Clutch/Brake) required for shift by operating Pressure-switchingvalve(SW) of valve body(v/b). Low leakage Light weight Rapid response Robust of vibration (excellent durability) Robust of contamination (for steel or aluminum powder in ATM) Supply Pressure (kgf/cm 2 ) 5.5 Control Pressure (kgf/cm 2 ) 0 / 5.5 Flow rate(s C) (ml/min) at 85, P=3 kgf/cm 2 2,000 Flow rate(c Ex) (ml/min) at 85, P=3 kgf/cm 2 3,500 Leakage (ml/min, at 85 ) Max 50

Variable Force Solenoid Valve (Direct control) Installed in valve-body of Auto transmission, control the hydraulic pressure (to Clutch/Brake) required for shift. Without such as Pressure-control-valve (PCV) of valve body (V/B), VFS operate directly the passing and blocking hydraulic pressure for shift control. Simple structure Low leakage & hysteresis in contrast long stroke 3 ports 3 filters (prevent contamination) Robust of contamination (for steel or aluminum powder in ATM) High magnetic force High pressure control & High discharge flow Rapid response / precision control NH type (Normally high pressure at non-current) / NL type (Normally low pressure at non-current) Supply Pressure 16 kgf/cm 2 Control Pressure 0 ~ 16 kgf/cm 2 Hysteresis < 0.8 kgf/cm 2 Flow rate Min 8,000 ml/min (@ 85 ) Leakage Max 1,000 ml/min (@ 85 )

Variable Force Solenoid Valve (Indirect control) HV5.2 K26 HV10 Installed in valve-body of Auto transmission the VFS controls the hydraulic pressure (to Clutch/Brake) required for shift. The VFS operates Pressure-control-valve(PCV) of valve body(v/b) indirectly, while passing and blocking hydraulic pressure for shift control. (1st control : VFS 2nd control : PCV) Multiple type (wide range of selections) -Type of Body / Magnetic Force / Filter mesh size / Flow / Pressure range / color No electrical contact failure Robust of vibration (excellent durability) Robust of contamination (for steel or aluminum powder in ATM) Light weight Rapid response & precision control NH type (Normally high pressure at non-current) / NL type (Normally low pressure at non-current) Supply Pressure (kgf/cm 2 ) Control Pressure (kgf/cm 2 ) HV5.2 K26 HV10 5.5 5.5 9.75 0 ~ 5.5 0 ~ 5.5 0 ~ 9.75 Hysteresis(kgf/cm 2 ) < 0.25 < 0.25 < 0.6 Flow rate (ml/min, at 85 ) Leakage (ml/min, at 85 ) Min 5,000 Min 3,000 Min 7,000 Max 510 Max 400 Max 730

Electronic Throttle Control From the accelerator pedal position, which reflects the driver s wishes for power, ECU calculates the appropriate throttle valve opening angle. Therefore drivability can be optimized. Idle speed control Compensation of engine torque Cruise control function Limp home function Operating temperature -40 ~ 140 Operating voltage 9 V ~ 16 V Response time 100 ms Linearity ±1.5 % 0