維 盟 科 技 有 限 公 司 Evowave Technology Co., Ltd. 規 格 書 / Specification Description: BLDC Vibration Motor Part No.: Date: 2015/04/16 地 址 : 新 北 市 汐 止 區 康 寧 街 169 巷 27 號 10 樓 之 1 Address: 10F 1, No.27, Lane 169, Kang ning St., Hsi Chih 221, Taipei, Taiwan. Tel: 886 2 2692 6058 Fax: 886 2 2692 6659 The copyright belongs to Evowave. Any unauthorized use is prohibited.
Page 2 of Standard 0 Product Name BLDC Vibration Motor No. Contents Page 1 변경이력 Revision History 3 2 적용범위 Application 4 3 표준사용조건 Standard Operating Condition 4 4 표준측정조건 Standard Measurement Condition 4 5 판정환경조건 Judgment Environmental Condition 5 6 시험오차범위 Test Tolerance 5 7 전기적특성 Electrical Characteristics 5 8 기계적특성 Mechanical Characteristics 6 9 특성그래프 Characteristic Graph 6 10 신뢰성시험 Reliability Test 7~8 주의사항 Caution 9 12 사양변경 Specification Change 10 13 안전규격 Safety Standard 10 14 도면 Specification Draw
Standard 0 Product Name BLDC Vibration Motor Page 3 of Doc. No. Date S-0825-S001-A 2014. 10. 30. 1. 변경이력 Revision History 변경번호 변경일 Rev. No. Date 변경내용 Description 설계 Designed 확인 Checked 승인 Approved 0 14/10/30 신규작성 released
Page 4 of Product Standard 0 Product Name BLDC Vibration Motor 2.적용범위 Application 본 사양서는 영진하이텍 공급하는 브러시레스 진동모터 표준사양서로 사용한다. This speccification applies to brushless type vibration motor. 3. 표준사용조건 Standard Operating Condition No. 3-1 사용전압범위 DC 2.5V ~ 3.6V Operating Voltage Range 3-2 보관온도범위 -40~+85 Storage Temperature Range 3-3 사용온도범위 Operating Temperature Range -20~+60 단,-20 에서는 +25 에 비해서 7-3항 정격회전수 감소현상이 있음. However, there is decrease of rated load speed of the section 7-3 at -20 compared to +25. 3-4 사용위치 전방향 Operating Position All Direction 4. 표준사용조건 Standard Measurement Condition No. 4-1 온도 Temperature 20±5 4-2 습도 Humidity 65%±15% RH 4-3 측정전압 Measurement Voltage DC3.0V 4-4 측정방법 Measuring Method ma Motor Condensor Switch + - M Jig 14/10/30 Sponge Oscilloscope Current Probe Amp. 표준측정상태 Standard Measurement State 검사회로도 Inspection Circuit Diagram - Jig : Φ50 t6.5 [Steel; 비자성체 (SUS303 or SUS304등)] - 중량 Weight : 100g - 고정방법 : 모터를 양면테이프(3M 9448HK)로 치구에 고정한 상태에서 측정. Motor shall be fixed on Jig by adhesive tape(3m 9448HK).
Page 5 of Product Standard 0 Product Name BLDC Vibration Motor 5. 판정환경조건 Judgment Environmental Condition No. 5-1 온도 20±5 5-2 Temperature 습도 65%±15%RH Humidity 6. 시험오차범위 Test Tolerance 시험조건과 장비은 별도지정이 없을 경우 다음의 조건을 만족해야 한다. Test set-ups and equipment shall be capable of maintaining following condition, unless otherwise specified. No. 6-1 상온/상습 20±15 /65±20%RH Room Temperature & Humidity 6-2 항온조온도 Test Chamber Temperature 지정치±3 Limits ±3 6-3 전압 지정치±0.15V Voltage Limits ±0.15V 7. 전기적특성 Electrical Characteristics No. 측정조건 Test Condition 規 格 Specification 7-1 7-2 전압범위 Rated Voltage 회전방향 [Red Wire (+), Black Wire(-)] DC 3.0V CW Rotating Direction 도면 참조 refer to Specification Draw 7-3 정격회전수 4항의 표준측정조건에 의함. 15,000 ± 3,500 rpm 7-4 Rated Load Speed 정격전류 It is based on the standard measurement condition of the section 4. 4항의 표준측정조건에 의함. 90 ma max 7-5 Rated Load Current 기동전류 It is based on the standard measurement condition of the section 4. 4항의 표준측정조건에 의함. 175 ma max 7-6 Starting Current 기동전압 It is based on the standard measurement condition of the section 4. 모터를 4-1, 4-2, 4-4항으로 지정한 상태로 고정한 후, DC 2.6 V max Starting Voltage On/Off 시험. Motor On/Off test based on the standard measurement condition of the section 4-1, 4-2, and 4-4. 7-7 절연저항 단자부와 모터 Case 사이를 절연저항계로 DC100V에서 측정. 10 MΩ min Insulation Voltage Measured between terminal and case with DC100V Megger.
0 Doc. No. Date S-0825-S001-A Standard 0 Product Name BLDC Vibration Motor 0 Page 6 2014. 10. 30. of 8. 기계적특성 Mechanical Characteristics No. 측정조건 Test Condition 8-1 진동력 7-3항의 회전수에 Vibration Force Pick-Up Motor Steel Jig(100g) Sponge 준함.(참조치) (3.0 m s2 MIN) It is referred to the rated load speed of the section 7-3 (reference) - 고정방법 : 모터를 양면테이프로 치구에 고정한 후 측정. (3.0 m s2 MIN) - Motor shall be fixed on Jig by adhesive tape. 8-2 기계적잡음 Micro phone 50dB MAX Mechanical Noise Motor 100mm Steel Jig( 100g) Sponge 8-3 - 암소음 Background Noise : 24dB MAX - 고정방법 : 모터를 양면테이프로 치구에 고정한 후 측정. - Motor shall be fixed on Jig by adhesive tape. 중량 about 0.95g Weight 9. 특성그래프 Characteristic Graph [ma] 200 [rpm] 20,000 150 15,000 V-N 100 10,000 V-I 50 5,000 0 2.5 3.0 3.5 4.0 4.5 [DC V]
Standard 0 Product Name BLDC Vibration Motor Page 7 of 10. 신뢰성 시험 Reliability Test No. 측정조건 Test Condition 10-1 상온회전수명 -정격회전수 : Room Temperature & 상온회전수명 초기치에서 +40, -20% Humidity Life Test Room Temp. & Humi. L/T -Rated Load Speed: 전압 Initial value +40, -20% DC 3.0V Voltage -정격전류: 온도 초기치에서 ±30% 20±5 Temperature -Rated Load Current: 습도 Initial value±30% 65±15% RH Humidity -기타 The others: 수명 7-6과 7-7항의 조건에 의함. 1,000,000 cycles Life cycles Conform to the section 주기 7-6 and 7-7. 0.5 sec ON /0.5 sec OFF Duty Cycle 모터는 접착테이프로 치구에 고정함. Motor shall be fixed on Jig by adhesive tape. (4-4항의 조건에 의함.) (Refer to the section 4-4) 10-2 10-3 저온방치시험 -40, 96시간 저온보관후 상온상습에서 4시간 방치후 측정. -정격회전수: Low Temperature Exposed to -40 for 96 hours and then room 초기치에서 ±30% Storage temperature for 4 hours. -Rated Load Speed: Performance Initial value±30% -정격전류: 초기치에서 ±30% 고온방치시험 +85, 96시간보관후 상온상습에서 4시간 방치후 측정. -Rated Load Current: High Temperature Exposed to +85 for 96 hours and then room Initial value ±30% Storage te 14/10/30 -기타 The others: Performance 7-6과 7-7항의 조건에 의함. Conform to the section 7-6 and 7-7. 10-4 고온고습방치시험 온도 +60, 습도 95%RH에서 96시간 방치후, 상온상습에서 4시간-목시검사에서 손상이 없을 것. High Temperature 방치후 측정. 녹, 얼룩이 없을 것. and Humidity Exposed to +60, 95%RH for 96 hours and then room 변형이 없을 것. Storage Performance temperature for 4 hours. -No scar, rust, stain, or deformation by visual 10-5 열충격조건 -40 와+85, 각 30분, 전체 100 cycles로 구성함. (1cycle=1 시간) inspection. Thermal Shock Test Total 100cycles at -40 and +85 for 30 minutes each (1cycle=1 H) 온도절환시간<5분 Temperature Change Time< 5min 상온상습에서 4시간 방치후 측정. Motor shall be measured after exposure at room temperature for 4 hours.
Standard 0 Product Name BLDC Vibration Motor Page 8 of 10. 신뢰성 시험 Reliability Test No. 측정조건 Test Condition 10-6 저온 수명 시험 - 샘플수량 : 10 - Sample Quantity : 10EA - 53,000 Cycles 후, Low Temperature - 테스트조건 : 정격전압에서 2.5초 ON/OFF 주기로 구동 정격회전수, 정격전류의 Life Test Condition - Test Condition : Use the rated voltage to driving the vibrator motor and setting the period time to 2.5sec on/off. -시험환경 : -20. -Test Environmental : -20 -시험주기 : 53,000cycles. - Test Cycle : 53,000Cycles 변화량이 초기치에 비해 ±35% 범위를 벗어나야 하지 말아야 함. 다른 모든 특성은 정해진 -측정주기: 매 20,000주기마다 전,후의 모든 전기적 특성을 측정. 사양에 부합하여야 함. -Check Cycles : Before, after test and every 20,000 cycles 측정은 상온에서 4시간 to measure the all electrical characteristic. 방치 후 측정해야 함. 방치 후 측정해야 함. 10-7 고온,고습 수명 시험 - 샘플수량 : 10 - Sample Quantity : 10EA After 53,000 Cycles : High Temperature - 테스트조건 : 정격전압에서 2.5초 ON/OFF 주기로 구동 The fluctuation of rated speed Humidity Life Test - Test Condition : Use the rated voltage to driving the vibrator and rated current is not over Condition motor and setting the period time to 2.5sec on/off. -시험환경 -Test Environmental : 65,Humidity 80%RH -시험주기 : 53,000cycles. - Test Cycle : 53,000Cycles ±35% of its initial value after the test. Other parameters must be -측정주기: 매 20,000주기마다 전,후의 모든 전기적 특성을 측정. within specification defined. -Check Cycles : Before, after test and every 20,000 cycles The measurement is conducted to measure the all electrical characteristic. after 4hours of recovery after climatic test. 10-8 낙하시험 모터를 약 150g Dummy set에 고정한 상태에서 150cm -정격회전수: Drop Test 높이에서 콘크리트면에 6면기준 각3회, 초기치에서 ±30% 합계18회 자유낙하. -Rated Load Speed: Dummy set (about 150g) motor shall be dropped Initial value±30% onto concrete plate. 3 times each side of 6 directions from -정격전류: a height of 150 cm, total 18 times. 초기치에서 ±30% 10-9 내진동시험 1) 모터를 Dummy set에 고정한 상태에서 10Hz~500Hz로 -Rated Load Current: Vibration Test 15분, 3방향으로 각2시간 시험. Initial value ±30% 가속도 : 1.5mm 又 は14.7m s2 -기타 The others: 진동방향 : x,y,z 7-6과 7-7항의 조건에 의함. 2) 모터를 Dummy set에 고정한 상태에서 33.3Hz로 Conform to the section 15분, 3방향로 각3시간 시험. 7-6 and 7-7. 가속도 : 43.2m s2 -목시검사에서 손상이 없을 것. 진동방향 : x,y,z 녹, 얼룩이 없을 것. 1) Dummy set motor shall be subjected to sine wave 변형이 없을 것. of 10Hz~500Hz -No scar, rust, stain, or each of 2 hours. deformation by visual acceleration : 1.5mm or14.7m s2 inspection. Direction : x,y,z (each 15 minutes) 2) Dummy set motor shall be subjected to sine wave of 33.2Hz each of 3 hours. Direction : x,y,z (each 15 minutes)
Standard 0 Page 9 of Product Name BLDC Vibration Motor. 주의사항 Caution No. -1 적용범위 Operating Range - 규격과 다른 사용조건에서 사용할 경우, 제품의 성능 및 수명에 문제가 발생할 수 있습니다. - When using on the operating condition different from a standard, a problem can be generated to the performance and the life of a product. -2 보관 Storage - 온도5~30, 습도60%이하일 것. - Temperature 5~30, Humidity 60% Max. -3 모터 취급 Motor Handling - 제품을 취급할 때 가능한 Case부분을 이용하고, 무리한 외력을 가하지 마십시오. - To handle the motor, hold the case softly. - 모터의 영구자석 가까이에 자기적 성질이 있는 물체의 접촉을 피해주십시오. 이러한 물체는 모터의 성능에 장애를 유발 시킬 수 있습니다. - Do not bring a magnetized object or attracted object by the magnet of motor, or such object may deteriorate a performance of motor. - 검사 부주의로 전원단자(+/-)의 Short시 Drive IC가 손상될 수 있습니다. DRIVE IC 손상을 방지하기 위하여 전원단자(+/-)간에 2uF이상의 콘덴서를 모터와 병렬로 연결하여 검사를 수행하는 것이 안전합니다. - At the time of power input short to the motor due to mis-operating, Drive IC of the motor inside can be damaged. To avoid this problem, please add capacitor of 2uF or more between the power line in parallel with the motor. - Drive IC 보호를 위해서 DC4.5V 이상 인가하지 마십시오. - Supplying voltage more than DC4.5V can make IC out of function. -4 기타 14 문제점 발생시 사양서를 근거로 하여 고객과 영진하이텍 상호간의 협의하에 Others 해결함을 원칙으로 합니다. It is made to a rule make specifications into a basis at the time of problem generating, and with a customer under deliberations between YJ Hi-Tech Co.,Ltd.
Page 10 of Product Standard 0 Product Name BLDC Vibration Motor 12. 사양변경 Specificification Change 변경이 있을 경우에는 사전에 그 내용과 실시 Lot등의 필수사항을 명기한 변경 요청서를 제출한다. 실시에 관해서는 사전에 협의하여 결정한다. 변경내역관리와 승인 필요한 경우에는 사양서에 개정기호를 표시한다. Even when there is any change to this specification, change application report which has the information of details of the change, lot of product, and etc shall be presented to customer before that change being carried out. And mutal discussion may be necessary before the change being corried out. Revision history shall be recorded on to the specification sheet when the change record and approval may be required. 13. 안전규격 Safety standard 해당없음. Not applicable
Standard 0 Product Name BLDC Vibration Motor Page of 14. 도면 Specification Draw