MV Drive-N5000 Up to 16,000 kv at 13.8 kv Electronics
N5000 EST SOLUTION YOU N RELY ON Up to 16,000 kv at 13.8 kv Hyundai Heavy Industries (HHI) N5000 MV drive offers advanced vector controls for efficient motor control ranging from 155 kw to 12, kw at 13.8 kv. With our extensive experience, N5000 is engineered with modular design for high reliabilty, easy installation and low maintenance cost. ONTENTS 04 Features / 08 ircuit onfiguration / 09 onnection / 10 Specifications / 11 Outline and Dimensions
Model Name Indication Series Name ppli Motor Output (kw) Voltage lass Frequency N5000-3930 H 5 L: 3,300 V M: 4,160 V H: 6, V E: 11,000 V U: 13, V 5: 50 Hz 6: 60 Hz
Medium Voltage Drive N5000 Features High Performance and Efficiency - Factor: over 0.95 No requirements for power factor correction capacitor - System Efficiency: over 97 % System efficiency is improved by connecting the power and motor without input-output filter and output transformer Factor/Efficiency (%) 100 90 80 70 60 50 40 30 lean Inverter Factor lean Inverter Efficiency onventional SR DRIVE 40 50 60 70 80 90 100 Speed (%) lean - clean input wave is achieved via a secondary phase-shifted transformer - Without a filter, N5000 meets the stringent harmonic requirements of IEEE-519 (1992) - Protects the other equipment from harmonic disturbance urrent Voltage Supplies of lean for Motors - Output waveforms, without a filter, are close to sine waves due to multiple PWM control ㆍNo length & motor type restrictions ㆍExisting motor can be used without modifications ㆍReduced noise and vibration of motors ㆍ3.3 kv - 13 level / 4.16 kv - 17 level / 6.6 kv - 21 level / 11 kv - 33 level / 13.8 kv - 41 level output (ased on line to line voltage) 6.6 kv Output Voltage Small Footprint and Economical Maintenance - Small footprint and reduced installation costs due to no requirements for ancillary equipments such as input & output filter and the integral structure incorporating the input transformer and inverter panel Filter TR Inverter Output Filter [ onventional System ] [ lean System ] - Thanks to the modulized single-phase inverter of draw-out type, easy maintenance and time saving are achieved. Filter TR Inverter Output Filter Outstanding Operation Features by the Improved Sensorless Vector ontrol - Energy saving V/F control for the fluid load (Fan, Pump) - Inherent speed sensorless vector control of N5000 ㆍHigh starting torque operation ㆍontrol of current, speed and vibration of motor at the low speed range of light duty ㆍQuick torque responsiveness and improved speed precision ㆍStrong control regardless of motor specifications Much more improved vector control functions can be achieved if the encoder is installed (Option). 04 HYUNDI HEVY INDUSTRIES
Multi-Winding Phase-Shifted Transformer ell Inverter ontrol Panel Multi-Winding Phase-Shifted Transformer ell Inverter ㆍ supply lead-in terminal and output terminal section to the cell inverter ㆍ3.3 kv: 9 phase shift windings / 18 pulse ㆍ4.16 kv: 12 phase shift windings / 24 pulse ㆍ6.6 kv: 15 phase shift windings / 30 pulse ㆍ11 kv: 24 phase shift windings / 48 pulse ㆍ13.8 kv: 30 phase shift windings / 60 pulse ㆍSelf standing panel type ㆍ3-10 cells connected in series per inverter output phase ㆍModulization of PWM controller and power conversion section ㆍ13 level (3.3 kv) / 17 level (4.16 kv) / 21 level (6.6 kv) / 33 level (11 kv) / 41 level (13.8 kv) 3 phase direct output ontrol Panel ㆍMain controller with dual PUs for high speed calculating digital signal process ㆍSelf-Diagnostic ㆍExtendable I/O board ㆍN communication control and optical signal transmission ㆍontrol circuit for UPS (customer) back-up (Option) HYUNDI HEVY INDUSTRIES 05
Medium Voltage Drive N5000 Features Functions for Trip-Free Operation Improved ell ypass (Option) In case of cell failure during operation, the faulty cell will be bypassed and the neutral point will be shifted (balance is restored through angle adjustment). 90 % of the rated voltage can be output after the failure of one cell. U U W-U Voltage = 6, V U-V Voltage = 6, V W-U Voltage = 6,060 V U-V Voltage = 6,060 V W V-W Voltage = 6, V V W V-W Voltage = 6,060 V V Normal Operation ell ypass Operation (with cell U3 out of service) Main MU with Dual PUs (Standard) Main MU in compliance with IE 61508 SIL3 (Safety Integrity Level - 3) by dual PUs. Redundant ell Optic ommunication (Option) If there are problems with the power cell communication during operation, an automatic switching to the standby reserve optical communication H/W is made. Redundant Supply for Main ontroller (Option) The redundant control power module in the main controller can receive 440 V and D 110 V supplied by a customer in the case of failure of one of the power supplies. 06 HYUNDI HEVY INDUSTRIES
Operator with User-Friendly Design (10.2 inch olor LD) - Multi language support Inverter Operation Status Display ㆍ Operation frequency, input-output voltage, output current ㆍ -output of external signals ㆍ MV switchgear on/off status ㆍ Output voltage wave form Inverter Fault Display ㆍ Fault type ㆍ Time of fault ㆍ Operating frequency at time of fault ㆍ Voltage and current at time of fault User Friendly P-ased onsole ㆍ Remote operation and monitoring via laptop or desktop ㆍ Easy parameter setting and monitoring ㆍ Various communication interfaces (Standard: RS-232, RS-485, Modbus), (Option: Ethernet, Profibus-DP, Devicenet) ㆍ MMI display and upgrade support ㆍ Display of detailed information HYUNDI HEVY INDUSTRIES 07
Medium Voltage Drive N5000 ircuit onfiguration 3.3 kv System ircuit onfiguration 6.6 kv System ircuit onfiguration ell U1 ell U2 ell U3 ell V1 ell V2 ell V3 ell W1 ell W2 ell W3 ell U1 ell U2 ell U3 ell U4 ell U5 ell V1 ell V2 ell V3 ell V4 ell V5 ell W1 ell W2 ell W3 ell W4 ell W5 3,300 V Induction Motor 6, V Induction Motor U U ell Voltage=635 V Phase Voltage 635 V Vu = 1,905 V 635 V Interline Voltage Vuv = 3,300 V 762 V 762 V 762 V 762 V 762 V Phase Voltage Vu = 3,810 V Interline Voltage Vuv = 6, V W V W V Single-Phase ell Inverter ( ell) 08 HYUNDI HEVY INDUSTRIES
09 HYUNDI HEVY INDUSTRIES ontrol apacity 3.5 kv (Except cooling fan power) onnection
Medium Voltage Drive N5000 Specifications Voltage lass 3,300 V 1) 3.3 kv Output apacity (kv) 200 300 400 500 750 1,000 1,250 1,750 2,250 3,500 4,000 Rated Output urrent () 35 53 70 88 105 132 175 219 263 307 350 394 473 525 619 707 Motor Output (kw) 2) 155 245 325 410 490 620 835 1,040 1,270 1,710 1,940 2,250 2, 3,200 Voltage lass 4,160 V 1) 4.16 kv Output apacity (kv) 250 380 500 640 750 950 1,250 1, 2,850 3,400 3,750 4,400 Rated Output urrent () 35 53 70 88 105 132 175 219 263 307 350 394 473 525 619 707 Motor Output (kw) 2) 205 310 410 530 630 790 1,040 1,310 1,630 2,160 2,460 3,240 3,500 4,000 Voltage lass 6, V 1) 6.6 kv Output apacity (kv) 400 1,000 3,500 4,000 4,500 5,400 6,000 7,000 8,000 Rated Output urrent () 35 53 70 88 105 132 175 219 263 307 350 394 473 525 619 707 Motor Output (kw) 2) 330 495 675 835 1,000 1,270 2,130 2,590 3,020 3, 3,930 4,500 5, 6,400 Voltage lass 11,000 V 1) 11 kv Output apacity (kv) 660 1,000 1, 3,300 4,100 5, 6, 7,500 9,000 10,000 11, 13,300 Rated Output urrent () 35 53 70 88 105 132 175 219 263 307 350 394 473 525 619 707 Motor Output (kw) 2) 820 1,120 1,390 1,660 2,110 2,830 3, 4,310 5,030 5,750 6, 7,500 8,330 9,330 10,660 Voltage lass 13, V 1) 13.8 kv Output apacity (kv) 1, 4,000 6,000 7,000 8,000 9,000 10, 1 14,000 16,000 Rated Output urrent () 35 53 70 88 105 132 175 219 263 307 350 394 473 525 619 707 Motor Output (kw) 2) 670 1,000 1,340 1,670 3,340 4,170 5,840 6,670 7,500 9,000 10,000 1 12, Output Output Frequency Range (Hz) Main ircuit 0-120 Hz 3-phase 3,300 V, 4,160 V, 6, V, 11,000 V or 13, V, 50 / 60 Hz Overload apacity ontrol ircuit / Tolerance 120 %, 60 sec 3-phase 200 V or 400 V, 50 Hz or 60 Hz / Voltage: ±10 %, Frequency: ±5 % Factor of Main Supply Efficiency ontrol Method Frequency Precision Torque haracteristics of Load pprox 95 % or more at normal operating speed pprox 97 % (Including transformer) at 100 % load V/F, Vector control, Sensorless vector control + Multi-level sinusoidal PWM (Pulse width modulation) ±0.5 % of maximum output frequency (nalog input) Variable torque load, onstant torque load 2 cceleration / Deceleration Time 0.1-3, sec (Depend on GD of load machine) Soft stall (utomatic load reduction control during overload), Ride-through function (0-83 ms, Main ontrol Function non-torque control), Specific frequency evasion function, Total run time display function, Non-Stop operation during speed reference loss, Multiple cc. / Dec. rate setting, Flying start Operation oard Signal Interface Main Protective Function Data Transmission Display ontrol Method nalog Digital urrent limit, Overcurrent, Overvoltage, Overload, Undervoltage, Ground fault, PU error, ooling fan abnormal, ontrol power abnormal RS 485 / 232, Modbus, Ethernet (Option), Profibus-DP (Option), Devicenet (Option) olor LD graphic display: olor TFT touch method 10.2 inch LD Start, Stop, Reset fault, Interlock (Emergency stop) : 4 channel (D 0-10 V or D 4-20 m) Output: 4 channel (D 0-10 V or D 4-20 m) : 16 channel (Dry contact) Output: 8 channel (Dry contact: 250 V 5 or D 30 V 5 ) Transformer Protection Degree of Enclosure Panel onstruction ooling Panel olor mbient Temperature / Humidity Noise Level ltitude Vibration Temperature class H, Dry type, Tapping range ±5 % for N5000 IP41 (IP20: ooling fan outlet), IP42 (Option) Self standing, Front maintenance type (Except 11 kv, 13.8 kv), Door handle key attached ir cooled by ventilation fans mounted on panels, Redundant cooling fans (Option) Munsell No. 5Y 7/1, Other colors (Option) 0-40 / Max 90 % (No condensation) Max 75 d () (Max 83 d: 6.6 kv over 4,500 kv, 11 kv over 7,500 kv, 13.8 kv over 9,000 kv) 1,000 m above sea level or less 0.5 G or less at 10-50 Hz pplications Fan, lower, Pump, ompressor, Extruder, Mixer etc. Standards Electrical performance: IE omponents and others: KS ontrol Speciation onstruction mbient onstructions 1) s for the non-standard voltage (3.0 / 6.0 / 6.3 / 6.9 / 10 kv etc.) motor, please contact Hyundai Heavy Industries. 2) ased on standard squirrel type 4 pole motors. 10 HYUNDI HEVY INDUSTRIES
Outline and Dimensions Type [Unit: mm] H1 H H2 D2 D1 H1 H D H2 H1 H H2 W FRONT VIEW D SIDE VIEW (RIGHT) Output ontrol SETION - Type [Unit: mm] W FRONT VIEW D1 D2 SIDE VIEW (RIGHT) Output ontrol SETION - Type [Unit: mm] W FRONT VIEW D1 D2 SIDE VIEW (RIGHT) D2 Output ontrol D1 SETION - HYUNDI HEVY INDUSTRIES 11
Medium Voltage Drive N5000 Outline and Dimensions Model Name Indication N5000 - Frequency 5: 50 Hz 6: 60 Hz Voltage L: 3.0 / 3.3 kv M: 4.16 kv H: 6.0 / 6.3 / 6.6 kv E: 11,000 V U: 13, V Motor apacity (kw) 155 kw: 0155 1,000 kw: 1000 3,020 kw: 3020 Panel Size for 50 Hz (3.3 kv, 4.16 kv) Frequency (Hz) 50 Hz Voltage (V) 3,300 4,160 Model Name 0155L5 0245L5 0325L5 0410L5 0490L5 0620L5 0835L5 1040L5 1270L5 1500L5 1710L5 1940L5 2250L5 2500L5 2L5 3200L5 0205M5 0310M5 0410M5 0530M5 0630M5 0790M5 1040M5 1310M5 1630M5 1900M5 2160M5 2460M5 2930M5 3240M5 3500M5 4000M5 apacity (kv) 200 300 400 500 750 1,000 1,250 1,750 2,250 3,500 4,000 250 380 500 640 750 950 1,250 1, 2,850 3,400 3,750 4,400 Panel Type Width (mm) Total Depth (mm) Width TR INV ON (mm) D1 (TR) D2 (INV + ON) 1, 1, 1, 1, 1, 1, 3, 3, 3, 3,900 3,900 3,900 4,400 5,500 5,500 1,825 1,825 2, 2, 1, 1, 1, 1, 1, 1, 1, 1, 3, 3, 4,100 4,200 4,200 4,400 4,400 4,400 5,100 6,500 6, Height (H1 + H2) (mm) 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, H1 With ase H2 Fan over s for the non-standard size, please contact Hyundai Heavy Industries. 12 HYUNDI HEVY INDUSTRIES
13 HYUNDI HEVY INDUSTRIES s for the non-standard size, please contact Hyundai Heavy Industries. Frequency (Hz) 50 Hz 6, 0330H5 0495H5 0675H5 0835H5 1000H5 1270H5 1700H5 2130H5 1590H5 3020H5 3H5 3930H5 0H5 5000H5 5H5 6400H5 E5 820E5 1120E5 1390E5 1660E5 2110E5 2830E5 3E5 4310E5 5030E5 5750E5 6E5 7500E5 8330E5 9330E5 10660E5 670U5 1000U5 1340U5 1670U5 2000U5 2500U5 3340U5 4170U5 5000U5 5840U5 6670U5 7500U5 9000U5 10000U5 11200U5 12U5 400 1,000 3,500 4,000 4,500 5,400 6,000 7,000 8,000 660 1,000 1, 3,300 4,100 5, 6, 7,500 9,000 10,000 11, 13,300 1, 4,000 6,000 7,000 8,000 9,000 10, 1 14,000 16,000 1, 1, 2, 2,060 2,060 2,180 2,420 2,420 2,540 2,540 2,660 2,660 2,780 2,780 2,780 2,900 3,020 2,160 2,160 2,280 2,640 2,640 2,760 2,760 2,880 2,880 2,880 3,120 4,500 4,500 1,720 1,720 3,960 3,960 2,900 2,900 4,200 4, 4, 4, 4,900 4,900 5,700 5,700 7, 7,700 4,260 4,260 4,820 5,060 5,180 5,180 5,300 5,300 5,420 5,420 5,540 6,100 6,100 7,660 7,780 4,460 4,460 4,980 5,100 5,400 5,520 5,520 5,640 5,640 5,760 5,760 5,880 6, 6, 8,500 8,620 2, 2, 2, 2, 2, 2, 2, 2, 11,000 Voltage (V) Model Name apacity (kv) Panel Type Width (mm) Total Width (mm) Depth (mm) Height (H1 + H2) (mm) H1 With ase H2 Fan over TR INV ON D1 (TR) D2 (INV + ON) 13, Panel Size for 50 Hz (6.6 kv, 11 kv, 13.8 kv)
Medium Voltage Drive N5000 Outline and Dimensions Panel Size for 60 Hz (3.3 kv, 4.16 kv) Frequency (Hz) 60 Hz Voltage (V) 3,300 4,160 Model Name 0155L6 0245L6 0325L6 0410L6 0490L6 0620L6 0835L6 1040L6 1270L6 1500L6 1710L6 1940L6 2250L6 2500L6 2L6 3200L6 0205M6 0310M6 0410M6 0530M6 0630M6 0790M6 1040M6 1310M6 1630M6 1900M6 2160M6 2460M6 2930M6 3240M6 3500M6 4000M6 apacity (kv) 200 300 400 500 750 1,000 1,250 1,750 2,250 3,500 4,000 250 380 500 640 750 950 1,250 1, 2,850 3,400 3,750 4,400 Panel Type Width (mm) Total Depth (mm) Width TR INV ON (mm) D1 (TR) D2 (INV + ON) 1, 1, 1, 1, 1, 1, 1, 1, 3, 3, 3, 3, 3, 3, 5,400 5,500 2, 2, 1, 1, 1, 1, 1, 1, 1, 1, 3, 3, 4,100 4,100 4,200 4,200 4,400 6,500 6,500 Height (H1 + H2) (mm) 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, H1 With ase H2 Fan over s for the non-standard size, please contact Hyundai Heavy Industries. 14 HYUNDI HEVY INDUSTRIES
Frequency (Hz) 60 Hz 6, 0330H6 0495H6 0675H6 0835H6 1000H6 1270H6 1700H6 2130H6 1590H6 3020H6 3H6 3930H6 0H6 5000H6 5H6 6400H6 E6 820E6 1120E6 1390E6 1660E6 2110E6 2830E6 3E6 4310E6 5030E6 5750E6 6E6 7500E6 8330E6 9330E6 10660E6 670U6 1000U6 1340U6 1670U6 2000U6 2500U6 3340U6 4170U6 5000U6 5840U6 6670U6 7500U6 9000U6 10000U6 11200U6 12U6 400 1,000 3,500 4,000 4,500 5,400 6,000 7,000 8,000 660 1,000 1, 3,300 4,100 5, 6, 7,500 9,000 10,000 11, 13,300 1, 4,000 6,000 7,000 8,000 9,000 10, 1 14,000 16,000 1, 1, 2,060 2,060 2,180 2,180 2,420 2,420 2,420 2,540 2,540 2,660 2,780 2,780 2,780 2,900 2,160 2,160 2,280 2,280 2,640 2,640 2,760 2,880 2,880 2,880 4,500 4,500 1,720 1,720 3,960 3,960 2,900 2,900 4,200 4,200 4, 4, 4, 4, 4,900 5,700 5,700 7,500 7, 4,260 4,260 5,060 5,060 5,180 5,180 5,180 5,300 5,300 5,420 6,100 6,100 7,540 7,660 4,460 4,460 4,980 4,980 5,400 5,400 5,520 5,520 5,520 5,640 5,640 5,760 6, 6, 8,380 8,500 2, 2, 2, 2, 2, 2, 2, 2, 11,000 Voltage (V) Model Name apacity (kv) Panel Type Width (mm) Total Width (mm) Depth (mm) Height (H1 + H2) (mm) H1 With ase H2 Fan over TR INV ON D1 (TR) D2 (INV + ON) 13, Panel Size for 60 Hz (6.6 kv, 11 kv, 13.8 kv)