레진시멘트의접착내구성에관한연구 레진시멘트의접착내구성에관한연구 조민우 박상혁 김종률 최경규 * 경희대학교대학원치의학과치과보존학교실 ABSTRACT THE BONDING DURABILITY OF RESIN CEMENTS Min-Woo Cho, Sang-Hyuk Park,
|
|
- 서진 좌
- 5 years ago
- Views:
Transcription
1 조민우 박상혁 김종률 최경규 * 경희대학교대학원치의학과치과보존학교실 ABSTRACT THE BONDING DURABILITY OF RESIN CEMENTS Min-Woo Cho, Sang-Hyuk Park, Jong-Ryul Kim, Kyoung-Kyu Choi* Department of Conservative Dentistry, Division of Dentistry, Graduate of Kyung Hee University The objectives of this study was to evaluate the durability of 4 resin cements by means of microtensile bond strength test combined with thermocycling method and fractographic FE-SEM analysis. Experimental groups were prepared according to thermocycling (0, 1,000, 5,000) and the kind of resin cements, those were Variolink II, Multilink, Panavia F 2.0, Rely X Unicem. Flat dentin surfaces were created on mid-coronal dentin of extracted third molars. Then fresh dentin surface was grounded with 320-grit silicon carbide abrasive papers to create uniform smear layers. Indirect composite block (Tescera, Bisco Inc., Schaumburg, IL, USA) was fabricated ( mm 3 ). It s surface for bonding to tooth was grounded with silicon carbide abrasive papers from 180- to 600-grit serially, then sandblasted with μm alumina oxide. According to each manufacturer s instruction, dentin surface was treated and indirect composite block was luted on it using each resin cement. For Rely X Unicem, dentin surface was not treated. The bonded tooth-resin block were stored in distilled water at 37 for 24 hours. After thermocycling, the bonded tooth-resin block was sectioned occluso-gingivally to 1.0 mm thick serial slabs using an Isomet slow-speed saw (Isomet, Buehler Ltd, Lake Bluff, IL, USA). These sectioned slabs were further sectioned to mm 2 composite-dentin beams. The specimens were tested with universal testing machine (EZ-Test, Shimadzu, Japan) at a crosshead speed of 1.0 mm /min with maximum load of 500 N. The data was analyzed using one-way ANOVA and Duncan s multiple comparison test at p 0.05 level. Within the limited results, we conclude as follows; 1. The bond strength of Variolink II was evaluated the highest among experimental groups and was significantly decreased after 1,000 thermocycling (p < 0.05). 2. The bond strength of Multilink was more affected by thermocycling than the other experimental groups and significantly decreased after 1,000 thermocycling (p < 0.05). 3. Panavia F 2.0 and Rely X Unicem showed the gradually decreased tendency of microtensile bond strength according to thermocycling but there was no significant difference (p > 0.05). * Corresponding Author: Kyoung-Kyu Choi Professor of Division of Dentistry, Graduate school of KyungHee University 1, Hoegi Dong, Dongdaemun Gu, Seoul, Korea, Tel: choikkyu@khu.ac.kr 343
2 대한치과보존학회지 : Vol. 32, No. 4, Adhesive based-resin cements showed lower bond strength with or without thermocycling than composite based-resin cements. 5. Variolink II & Multilink showed high bond strength and mixed failure, which was occurred with a thin layer of luting resin cement before thermocycling and gradually increased adhesive failure along the dentin surface after thermocycling. The bonding performance of resin cement can be affected by application procedure and chemical composition. Composite based-resin cement showed higher bond strength and durability than adhesive based-resin cement. [J Kor Acad Cons Dent 32(4): , 2007] Key words: Bonding Durability, Resin Cement, Variolink II, Multilink, Panavia F 2.0, Rely X Unicem - Received , revised , accepted Ⅰ. 서론 최근임상에서간접레진수복은심미적인요구가커짐에따라점차그수요가증가하는추세이다. 이러한술식은직접수복에비해수축응력이작기때문에술후민감성을감소시킬수있다. 간접레진수복을위해서는레진시멘트를사용해야하며치아와수복물간에직접붙는성질때문에 inlay, onlay, crown, post, veneer 등치과용수복물전반으로점차그사용범위가확대되고있다 1-5). 레진시멘트는상아질접착과정을기본으로하며, 치아에전처리없이사용하는자가접착형레진시멘트를제외하고전체산부식형또는자가부식형상아질접착제를필요로한다 6). 레진시멘트는상아질접착제의접착과정에따른방법과레진시멘트의중합방식에따른방법그리고접착기능성단량체의유무와시멘트의조성에따른방법으로분류한다. 레진시멘트의중합방식에따른방법으로자가중합, 이중중합, 광중합형레진시멘트로분류한다 7). 광중합형레진시멘트는색상, 조성등이다양하여심미적이고충분한작업시간을가지며광조사를통해빠른경화를가능하게하는장점을가지지만빛이투과하지못하는곳에서는사용할수없다. 이중중합레진시멘트는자가중합형과광중합형의특징을동시에가지게되지만대부분광중합이먼저선행되지않으면결합강도가저하되는경향이있다 8,9). 자가중합레진시멘트는고정된작업시간및경화시간을가지고빛이투과할수없는곳에사용한다. 접착기능성단량체의유무에따라서복합레진형레진시멘트 (composite based-resin cement) 와접착형레진시멘트 (adhesive based-resin cement) 로분류할수있다 7). 접착형레진시멘트는자가접착능력을지니며, 치질표면에대해스스로간단한부식과정을하거나또는직접적용할수있는레진시멘트이다. 이는접착기능성단량체 (4- META, 10-MDP, Phenyl P, 4-MET 등 ) 를포함하고있기때문이다. 반면에복합레진형레진시멘트는스스로접착할수있는능력이없어상아질접착제를적용한후이용하며그성분이복합레진과유사하기때문에심미성이좋고강도가우수하다. 레진시멘트의결합내구성은많은부분상아질내레진침투층 (resin infiltrated layer) 의영향을받게되며일상적인저작이나구강내온도변화, 이갈이, 기계적인 stress 등많은요소들이영향을끼치게된다. 인산을사용하여상아질을산부식한후접착레진을침투시키는방식인전체산부식형상아질접착제는상아질의탈회된교원질구조를따라접착레진이탈회된깊이만큼침투하지못할수도있다 10,11). 즉시간이경과하면서노출된교원섬유가가수분해되어상아질과접착제계면에서접착레진의결합강도가저하될수있다 12). 이에반해자가부식형접착제는부식및침투능력은제한되지만상아질의탈회와접착레진의침투가동시에이루어져탈회와침투의깊이차이가없으며교원섬유의노출가능성또한낮아산부식형상아질접착제에비하여상대적으로결합이안정적일수있다 13). 결합의내구성을평가하는보편적인방법은 37 수중보관으로이루어지는시효처리 (aging by storage in water) 이다. 고분자기질내로수분이침투하여고분자사슬의마찰력이감소되고기질이팽창 (swelling) 되어물리적성질이저하되며미중합레진단량체가용출되어서시간의경과에따라상아질접착제는변성되거나가수분해되어레진 - 상 344
3 아질간의결합이실패하게된다 14,15). 결합의내구성을평가하는다른방법에는열순환방법이있으며이는가장널리사용되는인공시효처리방법이다열순환방법은 5 55 의수중에서반복적으로침지순환을하는것으로수중보관시효처리보다효율적으로접착내구성을평가할수있다 15-17). 열순환기를이용한인공시효처리는다음의두가지과정을통해이루어진다. (1) 첫째, 온수가접착계면의노출된교원섬유의가수분해를촉진시키고미중합레진단량체들을용출시킨다 18,19). (2) 두번째는치질과수복물간열팽창계수의차이로수축과팽창이반복되어계면에균열이생기고이를통해온수가소통하게되며이는더욱균열이확장되는것을촉진하게된다 (percolation). Krejci 와 Lutz 20) 는열순환후에법랑질결합강도는변하지않았으나, 상아질결합강도는영향을받아감소하였으며, 상아질과레진사이의누출이존재하였다고보고하였다. 본연구는 4 종의레진시멘트를통해접착한상아질과간접레진수복물간의인장결합강도를측정하고, 열순환시 효처리여부에따른결합강도를비교하고, 주사전자현미경관찰을통하여각레진시멘트의접착내구성을평가하고자시행되었다. 1. 실험재료 Ⅱ. 실험재료및방법 우식이없는건전한 48 개의제 3 대구치를발치하여 Tymol 용액에보관한후미세인장결합강도측정및전계방출형주사전자현미경 (FE-SEM) 관찰에사용하였다. 본연구에서사용한레진시멘트는 Variolink II (Ivoclar Vivadent, Schaan, Lichtenstein), Multilink (Ivoclar Vivadent, Schaan, Lichtenstein), Panavia F 2.0 (Kuraray Medical Inc, Osaka, Japan), Rely X Unicem (3M ESPE, Seefeld, Germany) 이다. 이들의각구성성분과분류는 Table 1 과같으며각레진시멘트에사용되는상아질접착제와그분류는 Table 2 와같다. Table 1. Resin cements used in this study Resin cements Type Curing mode Composition Lot Number Variolink II (Ivoclar Vivadent Base Paste : BisGMA, UDMA, TEGDMA, DMA, J03646 Schaan, Composite Dual barium sulfate, Ba-Al-F-Si glass, ytterbium trifluoride J01609 Lichtenstein) Catalyst Paste : benzoylperoxide Multilink (Ivoclar Vivadent Self dimethacrylate, HEMA, barium glass filler, ytterbium H33577 Schaan, trifluoride, silica filler, catalyst, stabilizer Lichtenstein) A Paste : 10-MDP, bisphenol A polyethoxy dimethacrylate, hydrophobic dimethacrylate, hydrophilic dimethacrylate, 00176A Panavia F 2.0 benzoyl peroxide, silianated silica, colloidal silica, D,L-CQ (Kuraray, Adhesive Dual B Paste : bisphenol A polyethoxy dimethacrylate, hydrophobic Osaka Japan) dimethacrylate, hydrophilic dimethacrylate, N,N -diethanol- P-toluidine, sodium 2,4,6-trisopropyl benzene sulffinate, 00025B silanated barium glass, silanated titanium oxide, sodium fluoride, colloidal silica Rely X Unicem Powder : glass powder, silica, calcium hydroxide, pigment, (3M ESPE, Dual substituted pyrimidine, peroxy compound, initiator Seefeld Liquid : methacrylated phosphoric ester, dimethacrylate, Germany) acetate, stabilizer, initiator 345
4 대한치과보존학회지 : Vol. 32, No. 4, 실험방법 A. 실험군의분류 4 가지레진시멘트를이용하여복합레진 block 을상아질표면에결합시킨후, 각각 0, 1,000, 5,000 번열순환회수에따라 12 개의실험군으로분류하였다. B. 시편의제작 48 개의건전한제 3 대구치의교합면법랑질을제거한후저속 diamond saw (Isomet, Buehler Ltd, Lake Bluff, IL, USA) 로연마하여건전한상아질표면을노출시킨후표면을 #320 SiC paper 를이용하여연마하고표준도말층을형성하였다. 복합레진 block 을 Tescera (Bisco Inc., Schaumburg, IL, USA) 를사용하여 mm 3 의크기로제작하였다. 제작된복합레진 block 을순차적으로 #180, #320, #600 SiC paper 를이용하여연마하고 μm산화알루미늄으로 10 초간표면처리 (sandblast) 하여접착면을형성하였다. 제조사의지시에따라상아질접착제를적용한후, 치아표면에각레진시멘트를적용하고복합레진 block 을접착시켰다 (Table 3). Rely X Unicem 은치면처리를하지않고직접시멘트를적용하였다. 각시멘트를사용하여 12 개의치아에접착시킨후광조사가필요한 Variolink II, Panavia F 2.0, Rely X Unicem 에서는 LED 광중합기 (Elipar FreeLight 2, 3M ESPE, St. Paul, MN, USA) 를사용하여 40 초간중합시켰다 (Table 3). C. 시편의열순환제작된 12 개실험군의시편을 37 증류수에 24 시간동안보관한후, 열순환을시행하지않은즉시군 (T = 0), 1,000 회군 (T = 1000), 5,000 회군 (T = 5000) 으로나누어열순환기 ( 항온수조기, TaeWon Tech, Sihung, Korea) 에서열순환을시행하였다. 본실험의열순환기는 5 및 55 의항온수조로구성되며, 시편이수조에머무르는시간은각각 15 초이며이동시간은 6 초가소요되었다. 모든열순환과정은프로그램에의하여자동으로제어되도록하였다 (Figure 1). D. 미세인장결합강도측정접착된 12 개실험군의시편을저속 diamond saw (Buehler, USA) 를이용하여치아의장축을따라 1 mm의두께로절단하고, 이를다시수직절단하여단면적이약 1 mm 2 가되도록막대형시편을제작하였다 (Figure 2). 절단된시편을미세인장결합강도측정을위한 jig 에 Zapit (Palladium, USA) 을이용하여부착한후 universal testing machine (EZ Tester, Shimadzu, Japan) 을이용하여 1 mm /min 의속도로인장응력을가하여미세인장결합강도를측정하였다. 유의수준 0.05 level 에서 one-way ANOVA / Duncan s test 로통계분석하였다. Table 2. Bonding system of resin cements used in this study Resin cements Bonding Type Bonding system Composition Lot Number Variolink II (Ivoclar Vivadent Total etching Excite DSC : Etchant : 37% phosphoric acid gel J03640 Schaan, Adhesive : BisGMA, HEMA, ethanol, water, filler, CQ Lichtenstein) Multilink Primer A : water, initiator J04346 (Ivoclar Vivadent Self etching Primer B : phosphoric acid acrylate, HEMA, methacrylate Schaan, Lichtenstein) modified polyacrylic acid stabilizer J03234 ED Primer II A : 2-hydroxyethyl methacrylate, 10-MDP, Panavia F 2.0 N-methacryloyl 5-aminosalicylic acid, N,N - diethanol-p B (Kuraray Self etching toluidine, water Medical Inc, ED Primer II B : 2-hydroxyethyl methacrylate, sodium Osaka Japan) bezen sulfinate, N-methacryloyl 5-aminosalicylic acid, 00100A N,N -diethanol-p-toluidine, water, Rely X Unicem (3M ESPE, Seefeld Auto adhesive none Germany) 346
5 Table 3. Bonding procedure of resin cements used in this study Resin cement Bonding Procedure 1. etch for 15s, wash and blot dry Variolink II 2. apply Excite DSC for 10s, light cure for 10s 3. mix equal volume of base & catalyst 4. lute and light cure for 40s 1. mix Primer A & B 1:1 2. apply for 15s and wait 15s Multilink 3. dry with water & oil free air 4. mix Multilink paste 5. lute and wait 5 minutes 1. mix ED primer II A & B 1:1 2. apply and wait 30s Panavia F gently air dry 4. mix equal volume of paste A & B 5. lute and light cure for 40s 1. mix Applicap capsule by Rotomix for 10s Rely X Unicem 2. lute and light cure for 40s Thermocycling method : dwelled for 15s at each bath and interval for 6s : 0, 1000, 5000 cycles Figure 1. Schematic presentation of thermocycling method. Figure 2. Schematic presentation of μtbs testing. E. 전계방출형주사전자현미경 (FE-SEM) 관찰미세인장결합강도실험전에열순환을하지않은즉시군 (T = 0) 의시편의접착계면을수직절단하여노출된접착면을 #1500, #2000 SiC paper 와 ZnO 분말을이용하여연마하고산부식 3 초, NaOCl 에 3 분처리한후 gold sputtering (SC 502 sputter coater, VG Microtech, England) 하였고, 미세인장결합강도실험후의상아질측파단면을 gold sputtering 하여 FE-SEM (Leo Supra 55, Carl Zeiss, Germany; Genesis 2000, Edax, USA) 을이용하여관찰하였다. 347
6 대한치과보존학회지 : Vol. 32, No. 4, 미세인장결합강도 Ⅲ. 실험성적 Table 4 는 4 종류의레진시멘트의열순환전후의미세인장결합강도를나타내고있다. Variolink II 의경우, 2 단계전체산부식형상아질접착제 를사용하는복합레진형레진시멘트로서즉시군 (T = 0) 에서높은결합강도를보여주고있으며 1,000 회열순환이후에통계적으로유의성있는결합강도의감소가관찰되었으나 (p < 0.05), 5,000 회이후에는유의차가없었다 (Figure 3). Multilink 는 1 단계자가부식형상아질접착제를사용하며 1,000 회열순환이후에결합강도가유의성있게감소되 Table 4. Microtensile bond strengths(mpa, mean strength ± SD) of 12 experimental groups T = 0 T = 1000 T = 5000 Variolink II ± a ± b ± b Multilink ± b ± 9.21 c ± cd Panavia F ± cd ± cd ± 8.55 cd Rely X Unicem ± 6.94 cd ± 7.41 d ± 4.62 d * Groups with the same superscripts are not statistically significant. Figure 3. Microtensile bond strength of Variolink II. Figure 4. Microtensile bond strength of Multilink. Figure 5. Microtensile bond strength of Panavia F 2.0. Figure 6. Microtensile bond strength of Rely X Unicem. 348
7 Figure 7. Comparison of μtbs for each experimental group. 었고 (p < 0.05), 5,000 회이후에는유의차가없었다 (Figure 4). Panavia F 2.0 은자가부식형상아질프라이머를사용하는접착형레진시멘트로서복합레진형 (Variolink II) 보다즉시군에서결합강도가많이낮게나타났다. 열순환후점진적으로결합강도가감소되는양상을보여주고는있지만, 통계적으로유의성은없었다 (p > 0.05)(Figure 5). Rely X Unicem 은상아질접착과정을거치지않는자가접착형레진시멘트이며 4 가지레진시멘트중가장낮은결합강도를보여주었다. 그러나열순환이후에통계적으로유의성있는차이를보여주지않았다 (p > 0.05)(Figure 6). a b c d Figure 8. FE-SEM photograph illustrating the resin/dentin interface ( 1000). a. Cross-sectioned image of Variolink II. The thickness of resin cement was approximately 30 μm, hybrid layer was 10 μm, and the adhesive layer was likely thick. Uniform resin tags could be noticed. b. Cross-sectioned image of Multilink. The short and uncertain resin tags were formed. Hybrid layer was not certain. The thickness of resin cement was approximately 50 μm. c. Cross-sectioned image of Pavavia F 2.0. The thickness of resin cement was approximately 30 μm, slender resin tags were formed and hybrid layer was not certain. d. Cross-sectioned image of Rely X Unicem. The thickness of resin cement was approximately 15 μm and hybrid layer and resin tag were not formed. Notice slightly detached interface between resin cement and dentin. (RC : Resin cement, AD : Adhesive layer, HL : Hybrid layer, RT : Resin tag, D : Dentin, R : Tescera composite resin) 349
8 대한치과보존학회지 : Vol. 32, No. 4, 전계방출형주사전자현미경 (FE-SEM) 관찰 접착계면에대한 FE-SEM 관찰에서 2 단계전체산부식형상아질접착제를사용하는복합레진형레진시멘트인 Variolink II 에서두꺼운접착레진층과함께균질의혼성층이형성되어있고레진 tag 가잘형성되어있었다 (Figure 8a). 1 단계자가부식형상아질접착제를사용하는 Multilink 에서는혼성층이불분명하였고레진 tag 는약 5 μm정도로짧게형성되어있었다 (Figure 8b). 자가부식형상아질프라이머를사용하는 Panavia F 2.0 에서는마찬가지로혼성층이레진시멘트층과혼재되어불분명하였으며레진 tag 는가늘고길게형성되었다 (Figure 8c). 상아질접착과정을거치지않는 Rely X Unicem 은혼성층과레진 tag 는관찰되지않았다 (Figure 8d). 파단면의관찰에서 Variolink II 의열순환하기전시편에서혼합형파괴양상이관찰되었으며, 이후열순환에의해접착성파괴양상이증가하는경향을나타내었다 (Figure 9, 13). Multilink 의경우, 열순환하기전시편에서는혼합형파괴양상이관찰되었으며, 열순환이후접착성파괴양상을보여주었다 (Figure 10, 14). Panavia F 2.0 의경우열순환전후접착성파괴양상을보여주었다 (Figure 11). Rely X Unicem 의경우에는접착층이없으며열순환전비균일한레진시멘트의파괴가관찰되었으나, 열순환후점차균일한파괴양상이관찰되었다 (Figure 12). a b a : mixed failure without thermocycling b : adhesive failure with thermocycling of 5,000 cycle Figure 9. Debonded interface of Variolink II ( 100). A : adhesive, D : dentin a b a : mixed failure without thermocycling b : adhesive failure with thermocycling of 5,000 cycle Figure 10. Debonded interface of Multilink ( 100). A : adhesive 350
9 a b a : adhesive failure without thermocycling b : adhesive failure with thermocycling of 5,000 cycle Figure 11. Debonded interface of Panavia F 2.0 ( 100). A : adhesive a b a : failure without thermocycling b : failure with thermocycling of 5,000 cycle Figure 12. Debonded interface of Rely X Unicem ( 100). Figure 13. Debonded interface of Variolink II without thermocycling ( 1000). Failure mode was mixed failure and dentinal tuble was observed. Figure 14. Debonded interface of Multilink without thermocycling ( 2000). Failure mode was mixed failure and small dentinal tubule was observed. 351
10 대한치과보존학회지 : Vol. 32, No. 4, 2007 Ⅳ. 총괄및고안 접착치과학은괄목할만한성장을이루었으며이는상아질접착기술의발전이근간을이루고있다. 최근의상아질접착시스템에는상아질과의결합을향상시키기위하여친수성을지닌레진단량체가포함되어있다 21). 친수성레진단량체가포함된프라이머를사용하는전체산부식형접착제는상아질내교원질을탈회시키고친수성단량체가그공간및상아세관내로침투할수있게해준다 22). 반면에자가부식형접착제는충분한산도를가지고도말층을없애지않고용해변형시켜상아질과접착한다 23). 본연구는상아질접착방식및성분에따라레진시멘트를구분하고열순환전후의결합강도를비교하여임상적으로내구성파악에도움을주고자하였다. 본연구에사용된레진시멘트는상아질접착방식에따라전체산부식형혹은자가부식형상아질접착제를사용하는레진시멘트, 상아질접착제를사용하지않는레진시멘트로분류할수있다. 또한접착능력을가지는기능성단량체의유무에따라복합레진형레진시멘트 (composite based-resin cement) 와접착형레진시멘트 (adhesive based-resin cement) 로분류할수있다. 2 단계전체산부식형접착제를사용하는 Variolink II 의경우는복합레진형레진시멘트이다. 실험결과에서다른레진시멘트보다월등히높은미세인장결합강도를보여주었는데, 이는산부식과상아질접착제의도포를통해다른자가부식형접착제와는달리두꺼운혼성층과굵고깊은레진 tag 가형성되었기때문으로생각된다 (Figure 8a). 더욱이복합레진형레진시멘트로서다른접착형레진시멘트보다성분이복합레진에가깝기때문에물리적성질이우수했기때문으로볼수있다. 열순환이후에결합강도가감소하였고 5,000 회열순환이후에는즉시군 (T = 0) 보다약 22% 가감소되는결과를보여주었다 (Table 4). 또한 FE- SEM 을통한파단면관찰을통해열순환을할수록접착성파괴가일어남을알수있었다 (Figure 9). 전체산부식형접착제를적용할때, 탈회된상아질의교원질구조내로완전히침투가되지않는층 (hybridoid layer) 이발생하고, 용매가모두제거되지않으면친수성단량체가다량존재하기때문에불안정한혼성층이형성될수있다. 따라서열순환시행후가수분해가일어나결합강도의저하또는변연누출등이일어나기쉽다 24). Armstrong 등 25) 은상아질접착후수중에서 15 개월보관하고미세인장결합강도를측정한결과, 2 단계전체산부식형접착제의결합강도는 3 단계또는 2 단계자가부식형접착제에비하여시간경과에따라결합강도가감소한다고하였으며, 파괴양상은 2 단계전체산부식형접착제에서시간경과에따라접착성파괴가증가하였다고보고하였다. 즉 Variolink II 의경우결합강도의감소는열순환후접착층의내구성이약화되었기때문으로사료된다. Multilink 는자가부식형레진시멘트로서 6 세대상아질접착제를사용한다. 구성성분상 HEMA 를포함하기때문에접착형레진시멘트의일종으로볼수있지만접착력의대부분을상아질접착제가담당하게된다 (Table 1). HEMA 를제외하고는복합레진성분과유사하고다른접착형레진시멘트보다즉시군 (T = 0) 에서결합강도가높게나타났다. 결합강도는 1,000 회열순환이후유의성있게감소되었으며 (p < 0.05), 5,000 회이후에는즉시군보다약 44% 가감소되는결과를보여주었다 (Table 4). 6 세대자가부식형상아질접착제는시술과정의단순화및편의성이라는장점을가지는반면접착신뢰성과내구성에는아직까지문제가있음을지적받고있다 26). Amstrong 등 26) 은 6 세대자가부식형상아질접착제가와동형태와수중시효처리에매우민감하다고하였다. 6 세대자가부식형접착제의내구성은 5 세대접착제에비하여낮은것으로보고되고있으며, 이는임상적접착력평가에주로이용되는 5 급와동에대한연구에서입증되었다 27,28). Multilink 의열순환이후급격한결합강도감소는자가부식능력의제한으로접착레진의불완전한침투가원인으로추정된다 (Figure 8b). FE-SEM 을통한파단면관찰에서초기열순환전에는혼합형파괴양상을보이나열순환이후접착성파괴양상을보여이설명에부합한다할수있을것이다 (Figure 10). Panavia F 2.0 은자가부식형프라이머를사용하며접착기능성단량체인 10-MDP 를포함하고있는접착형레진시멘트이다. 즉시군 (T = 0) 의결합강도는복합레진형레진시멘트와비교하여낮은값을보여주고있으며, 열순환이후에점진적인감소양상을보여주고는있지만통계적인유의차는없었다 (p > 0.05)(Table 4, Figure 5). Panavia F 2.0 은상아질접착제의적용과정이일반적인레진시멘트와는다른방식이다. ED primer II 는 2 bottle 로구성되어있고혼합하여도포하는방식이다. 즉 ED primer II 를도포하고접착레진의도포없이시멘트를적용하는것으로이는시멘트내의기능성단량체가직접상아질에작용하도록설계된것이다. 동일회사의 5 세대자가부식형상아질접착제인 Clearfil SE bond 의경우 primer 와 adhesive 로구성되어있으며이제품의 primer 는 Panavia F 2.0 에포함된 ED primer II 와그성분이유사하다. SE bond 의 adhesive 는접착레진으로접착기능성단량체 (10-MDP) 와레진기질, 미세필러를함유하고있다. Panavia F 2.0 의경우열순환후결합강도가별로감소되지않았는데, 이것은 5 세대자가부식형상아질접착제가열순환에영향을적게받는다는연구에서그원인을찾을 352
11 수있을것이다 29-31). Panavia F 2.0 은 ED primer II 를통한상아질전처리후에접착형시멘트를직접적용하기때문에 2 단계자가부식형상아질접착제인 Clearfil SE bond 와유사한방식으로접착되는것이다. 파단면관찰을통해서 Panavia F 2.0 은열순환을하지않았을때접착성파괴가일어나는것을알수있는데 (Figure 11), 이것은이시멘트의낮은결합강도와자가부식형상아질접착제의특성으로혼성층상방에서분리되었기때문으로사료된다. Rely X Unicem 은상아질접착제를사용하지않는자가접착형레진시멘트로서기능성단량체로 methacrylated phosphoric ester 를함유하고있으며산부식과동시에레진기질로작용을한다 (Table 1). 하지만 FE-SEM 관찰에서다른레진시멘트와는달리혼성층이나레진 tag 가형성되지않았다 (Figure 8d). 이는선학들의연구와같은양상을보여주고있다 32.33). Rely X Unicem 은다이아몬드버등의삭제로형성된거칠고불규칙한상아질표면을미약하게탈회시키고기계적인접합층을형성한다 32). 이에따라낮은결합강도가보고되었고본실험에서도확인되었다. 하지만열순환이후결합강도의감소가적게나타났으며 (Table 4), 이는접착층이거의존재하지않는이레진시멘트의특성으로이해할수있을것이다. 본연구에서산부식과정을거치고상아질접착제를적용하는복합레진형레진시멘트로 Variolink II 를사용하였다. 레진시멘트를적용할때상아질접착제의접착력에의존하게되는복합레진형레진시멘트는현재까지발전된상아질접착기술에의해서그결합강도가매우우수하며본실험에서도또한확인되었다. Multilink 의경우 HEMA 를포함하고있어완전한복합레진형으로분류할수는없지만접착력의상당부분이상아질접착제에의한것으로생각된다. 이것은열순환이후에결합강도가유의성있게감소되었고, 이는 6 세대자가부식형상아질접착제들에서나타나는내구성이약화된다는보고와일치하기때문이다. 이를종합할때복합레진형레진시멘트는적절한상아질접착제를함께사용할경우높은내구성과결합강도를가질것으로생각된다. Panavia F 2.0 에서는상아질전처리로 ED primer II 를사용하였다. Carvalho 등 6) 은 Panavia F 를사용할때부가적으로레진층을도포하면결합강도가증가됨을보고하였다. 본실험과유사한방식으로진행되었던선행연구에서김등 34) 은 Panavia F 와 Clearfil SE bond 를사용하였을경우, 미세인장결합강도가약 35.7 MPa 까지증가한다고보고하였다. 따라서 Panavia F 2.0 을적용할때에는부가적인접착레진의도포가결합강도와내구성을증가시킬수 있을것으로사료되며이는제조사에서참고할수있을것이다. Rely X Unicem 은레진시멘트가나아가야할다른방향을제시하고있는선행재료라할수있다. 본연구의열순환이최대 5,000 회이므로이를임상에적용하거나일반화된실험방법으로평가하기는어려울것이다. 하지만전처리또는접착과정이없는새로운개념의레진시멘트는초기결합강도는다른레진시멘트에비하여현저히낮지만안정성에서는유리한측면이있어앞으로이에대한논의와연구가더필요할것으로생각된다. 본연구는열순환으로최대 5,000 회를시행하였고교합압이작용하는환경은고려치않았다는점에서임상적으로적용시키는데에한계가있다. 열순환횟수를더증가시켰을경우, 결합강도의감소양상은본연구결과와상이할수도있을것이다. 하지만본실험결과에국한하여볼때, 적절한상아질전처리와접착과정을행한다면복합레진형레진시멘트는접착형레진시멘트보다결합강도와내구성이우수하다고할수있을것이다. 앞으로이에대한지속적인연구가진행되어야할것으로생각한다. Ⅴ. 결론 서로다른접착과정을갖는 4 가지레진시멘트를이용하여상아질에간접레진으로수복을하였고이시편의열순환 0 회, 1,000 회, 5,000 회시효처리후의미세인장결합강도를측정하였다. 접착계면과파단면을 FE-SEM 을통하여관찰한결과다음의결론을얻었다. 1. Variolink II 의결합강도는다른실험군보다높게나타났으며, 1,000 회열순환후유의성있게감소되었다 (p < 0.05). 2. Multilink 의결합강도는열순환에가장많은영향을받았으며 1,000 회열순환이후유의성있게감소되었다 (p < 0.05). 3. Panavia F 2.0 과 Rely X Unicem 의결합강도는열순환에의하여감소되지않았다 (p > 0.05). 4. 접착형레진시멘트는복합레진형레진시멘트에비해서열처리전후모두낮은결합강도를보여주었다. 5. 결합강도가높은 Variolink II 와 Multilink 에서는혼합형파괴양상을보였고, 결합강도가낮은 Panavia F 2.0 에서는접착성파괴양상을나타내었다. 접착성간접수복물의결합강도와내구성은레진시멘트의접착과정과종류, 형태에의해영향을받기때문에이들의적절한선택과올바른사용이성공적인수복을위해중요하다. 353
12 대한치과보존학회지 : Vol. 32, No. 4, 2007 참고문헌 1. Manhart J, Scheibenhogen Fuchsbrunner A, Chen HY, Hiekel R. A 2-year clinical study of composite and ceramic inlays. Clin Oral Invest 4:192-8, Peumans M, Van Meerbeek B, Lambrechts P, Vanherle G. Porcelain Veneers; a review of the literature. J Dent 28:163-77, Mitchell CA, Abbariki M, Orr JF. The influence of luting cement on the probabilities of survival and modes of failure of cast full-coveraged crowns. Dent Mater 16: , Knox J, Kralj B, Hubsch PF, Middleton J, Jones ML. An evaluation of the influence of orthodontic adhesive on the stresses generated in a bonded bracket finite element model. Am J Ortho Dent Orthop 119;43-53, el-mowafy O, Rubo MH. Retention of a posterior resinbonded fixed partial denture with a modified design : an in vitro study. Int J Prosthod 13:425-31, Carvalho RM, Pegoraro TA, Tay FR, Pegoraro LF, Pashley DH. Adhesive permeability affects coupling of resin cements that utiliseself-etching primers to dentine. J Dent 32:55-65, Kramer N, Lohbauer U, Frankenberger R. Adhesive luting of indirect restorations. Am J Dent 13:60D-76D, Hasegawa EA, Boyer DB, Chan DC. Hardening of dual-cured cements under composite resin inlays. J Prosthet Dent 66:187-92, el-badrawy WA, el-mowafy OM. Chemical versus dual curing of resin inlay cements. J Prosththet Dent 73:515-24, Primenta LAF, Amaral CM, Bredrane de Castro AKB, Ritter AV. Stability of dentin bond strengths using different bonding techniques after Total-etch, deproteinization and self-etching. Oper Dent 29: , 11. Paul SJ, Welter DA, Ghazi M, Pashley D. Nanoleakage at the dentin adhesivevs. microtensile bond strength. Oper Dent 24: , Giannini M, Seixas CAM, Reis AF, Pimenta LAF. Sixmonth storage-time evaluation of one-bottle adhesive systems to dentin. J Esth Rest Dent 15:43-49, Tay FR, Pashley DH, Yoshiyama M. Two mondes of nanoleakage expression in single-step adhesives. J Dent Res 81: , Sano H, Yoshikawa T, Pereira PNR, Kanemura N, Morigami M, Tagami J, Pashley D. Long-term Durability of dentine bonds made with a self-etching primer. J Dent Res 78: , Kato G, Nakabayashi N. The durability of adhesion to phosphoric acid etched,wet dentine substrates. Dent Mater 14: , Hakimeh S, Vaidyanathan J, Houpt ML, Vaidyanathan TK, Hagen SV. Microleakage of compomer class V restorations: effect of load cycling, thermal cycling, and cavity shape differences. J Prosthet Dent 83: , Wendt SL, Mcinnes PM, Dickinson GL. The effect of thermocycling in microleakage analysis. Dent Mater 8: , Miyazaki M, Sato M, Onose H, Moore BK. Influence of thermal cycling on dentin bond strength of two-step bonding systems. Am J Dent 11: , Hashimoto M, Ohno H, Kaga M, Endo K, Sano H, Oguchi H. In vivo degradation of resin-dentin bonds in humans over 1 to 3 years. J Dent Res 79: , Krejci I, Lutz F. Mixed class V restorations: the potentials of dentine bonding. J Dent 18: , Suh BI, Feng L, Pashley DH, Tay FR. Factors contributing to the incompatibility between simplified-step adhesives and chemically-cured or dual-cured composites. Part III. Effect of acidic resin monomers. J Adhes Dent 5: , Attal JP, Asmussen E, Degrange M. Effects of surface treatment on the free surface energy of dentin. Dent Mater 10: , Tay FR, Pashley DH. Aggressiveness of contemporary self-etching systems. I: Depth of penetration beyond dentin smear layers. Dent Mater 17: , Frankenberger R, Strobel WO, Lohbauer U, Kramer N, Petschelt A. The effect of six years of water storage on resin composite bonding to human dentin. J Biomed Mater Res Part B: Appl Biomater 69:25-32, Armstrong SR, Vargas MA, Fang Q, Laffoon JE. Microtensile bond strength of a total-etch 3-step, total-etch 2-step, self-etch 2-step, and a self-etch 1- step dentin bonding system through 15-month water storage. J Adhes Dent 5:47-56, Tay FR, Pashley DH. Dental adhesives of the future. J Adhes Dent 4:91-103, Brackett MG, Dib A, Brackett WW, Estrada BE, Reyes AA. One-year clinical performance of a resin-modified glass ionomer and a resin composite restorative material in unprepared Class V restorations. Oper Dent 27:112-6, Türkün SL. Clinical evaluation of a self-etching and a one-bottle adhesive system at two years. J Dent 31: , Takahashi A, Inoue S, Kawamoto C, Ominato R, Tanaka T, Sato Y, Pereira PNR, Sano H. In vivo longterm durability of the bond to dentin using two adhesive systems. J Adhes Dent 4: , Miyazaki M, Sato M, Onose H, Moore BK. Influence of thermal cycling on dentin bond strength of two-step bonding systems. Am J Dent 11: , Nikaido T, Kunzelman KH, Chen H, Ogata M, Harada N, Yamaguchi S, Cox CF, Hickel R, Tagami J. Evaluation of thermal cycling and mechanical loading on bond strength of a self-etching primer system to dentin. Dent Mater 18: , Jan DM, Marcos V, Kirsten VL, Kazuhiro H, Paul L, Bart VM. Bonding of an auto-adhesive luting material to enamel and dentin. Dent Mater 20: , Bin Y, Klaus L, Rainer A, Matthias K. Microtensile bond strength of three luting resins to human regional dentin. Dent Mater 22:45-46, 김도완, 최경규, 박상진. 자가부식형상아질접착제와레진시멘트와의적합성에관한연구. 대한치과보존학회지 30: ,
13 국문초록 조민우 박상혁 김종률 최경규 * 경희대학교대학원치의학과치과보존학교실 4 종의레진시멘트를통한상아질과간접레진수복물간의인장결합강도를열순환시효처리여부에따라측정하여비교하고, 주사전자현미경관찰을통하여각레진시멘트의접착내구성을평가하고자시행하였다. 48 개의건전한제 3 대구치의상아질표면을평탄하게노출시키고 #320 grit Sic Paper 로연마하였다. 복합레진블록을제작하여 #600 grit Sic Paper 로연마한후에접착면을 Sandblast 로처리하였다. 각각의레진시멘트로제조사지침에따라적용하여복합레진블록을상아질표면에접착하였다. 이후제작된시편을열순환시키지않거나, 1,000 회, 5,000 회열순환시킨후 (5-55 ) 미세인장결합강도를측정하였다. 열순환전시편의접착계면 ( 수직절단면 ) 과파절된시편의상아질파단면을전자현미경관찰하여다음과같은결론을얻었다. 1. Variolink II 의결합강도는다른실험군보다높은결합강도를보여주었으며, 1,000 회열순환후유의성있게결합강도가감소되었다 (p < 0.05). 2. Multilink 의결합강도는열순환에가장많은영향을받았으며 1,000 회열순환이후유의성있게감소되었다 (p < 0.05). 3. Panavia F 2.0 과 Rely X Unicem 의결합강도는열순환에의하여감소되지않았다 (p > 0.05). 4. 접착형레진시멘트는복합레진형레진시멘트에비해서열처리전후모두낮은결합강도를보여주었다. 5. 결합강도가높은 Variolink II 와 Multilink 에서는혼합형파괴양상을보였고, 결합강도가낮은 Panavia F 2.0 에서는접착성파괴양상을나타내었다. 이상의연구결과를토대로적절한전처리와접착제를도포한다면복합레진형레진시멘트는접착형레진시멘트보다결합강도와그내구성이우수하다고할수있을것이다. 접착성간접수복물의초기결합강도와내구성은레진시멘트의접착과정과종류, 형태에의해영향을받기때문에이들의적절한선택과올바른사용이성공적인수복을위해중요하다. 주요어 : 접착내구성, 레진시멘트, Variolink II, Multilink, Panavia F 2.0, Rely X Unicem 355
법랑질에대한 total etching과 self-etching 접착제의산부식효과와미세인장결합강도 법랑질에대한 total etching과 self-etching 접착제의산부식효과와미세인장결합강도 오선경 허복 * 김현철부산대학교치과대학보존학교실 ABSTRACT THE ET
법랑질에대한 total etching과 self-etching 접착제의산부식효과와미세인장결합강도 법랑질에대한 total etching과 self-etching 접착제의산부식효과와미세인장결합강도 오선경 허복 * 김현철부산대학교치과대학보존학교실 ABSTRACT THE ETCHING EFFECTS AND MICROTENSILE BOND STRENGTH OF TOTAL
More information간접복합레진합착시자가부식형과자가접착형레진시멘트의상아질에대한미세인장결합강도 거칠게함으로써얻어진다. 3,4) 한편치질에대한레진시멘트의접착은인산이나프라이머를이용한치질의전처리에의해이루어진다. 레진시멘트는접착시스템과마찬가지로치질의처리방법에따라전체산부식형 (total-etch),
간접복합레진합착시자가부식형과자가접착형레진시멘트의상아질에대한미세인장결합강도 박재구 1 조영곤 1 * 김일신 2 1 조선대학교치의학전문대학원치과보존학교실, 2 전남대학교대학원치의학과 ABSTRACT MICROTENSILE BOND STRENGTH OF SELF-ETCHING AND SELF-ADHESIVE RESIN CEMENTS TO DENTIN AND INDIRECT
More information관하여여러연구들이진행되어왔다. Kious 등 3 의연구에서는, 실험에사용된접착제들이모두혼합후 2 분안에 50 N 의부하에서 25 μm이하의피막도를가졌다. Windeler 는접착제의작업시간은접착제의점성변화와직접적으로연관이있으며, 작업시간은보철물장착시최소한의피막도에이르는시
ORIGINAL ARTICLE http://dx.doi.org/0.4047/jkap.205.53.4.325 이유승 김성훈 2 * 이재봉 2 한중석 2 여인성 2 하승룡 3 김희경 4 서울대학교치의학대학원, 2 서울대학교치의학대학원치과보철학교실, 3 아주대학교의과대학치의학과, 4 중앙보훈병원치과병원치과보철과 Effect of working time on the
More information대한치과보존학회지 :Vol. 29, No. 4, 2004 치수압이상아질접착제의미세전단결합강도에미치는영향에관한 In vitro 연구 송윤정 박성호 * 연세대학교치과대학치과보존학교실 ABSTRACT MICRO-SHEAR BOND STRENGTH TO DENTIN UNDER
송윤정 박성호 * 연세대학교치과대학치과보존학교실 ABSTRACT MICRO-SHEAR BOND STRENGTH TO DENTIN UNDER SIMULATED PULPAL PRESSURE Yun-Jung Song, Sung-Ho Park* Department of Conservative Dentistry, College of Dentistry, Yonsei University
More informationMicrosoft Word doc
1 2 3 감사의글 본논문이완성되기까지사랑과배려로지도해주신정문규교수님께진심으로감사드리며, 논문의진행과정동안관심을가지고조언을아끼지않으신이근우교수님께깊은감사를표합니다. 또한본논문에많은가르침을주시고격려해주신심준성교수님께도감사를드립니다. 본연구에도움을주신유지성선생님과치과재료학교실의박혜옥선생님께도감사를드리며, 끝으로늘변함없는사랑으로기도해주시고걱정해주시는사랑하는부모님께이논문을바칩니다.
More information저작자표시 - 비영리 - 변경금지 2.0 대한민국 이용자는아래의조건을따르는경우에한하여자유롭게 이저작물을복제, 배포, 전송, 전시, 공연및방송할수있습니다. 다음과같은조건을따라야합니다 : 저작자표시. 귀하는원저작자를표시하여야합니다. 비영리. 귀하는이저작물을영리목적으로이용할
저작자표시 - 비영리 - 변경금지 2.0 대한민국 이용자는아래의조건을따르는경우에한하여자유롭게 이저작물을복제, 배포, 전송, 전시, 공연및방송할수있습니다. 다음과같은조건을따라야합니다 : 저작자표시. 귀하는원저작자를표시하여야합니다. 비영리. 귀하는이저작물을영리목적으로이용할수없습니다. 변경금지. 귀하는이저작물을개작, 변형또는가공할수없습니다. 귀하는, 이저작물의재이용이나배포의경우,
More informationDBPIA-NURIMEDIA
The e-business Studies Volume 17, Number 4, August, 30, 2016:319~332 Received: 2016/07/28, Accepted: 2016/08/28 Revised: 2016/08/27, Published: 2016/08/30 [ABSTRACT] This paper examined what determina
More information대한치과보존학회지 : Vol. 30, No. 6, 2005 수종의단일병접착제의적용시간연장이건조상아질의미세인장결합강도에미치는영향 김학근 김동준 황윤찬 오원만 황인남 * 전남대학교치과대학치과보존학교실 ABSTRACT EFFECT OF INCREASING APPLICATIO
김학근 김동준 황윤찬 오원만 황인남 * 전남대학교치과대학치과보존학교실 ABSTRACT EFFECT OF INCREASING APPLICATION TIME OF SINGLE BOTTLE ADHESIVES TO MICROTENSILE BOND STRENGTH OF DRIED DENTIN Hak-Geun Kim, Dong-Jun Kim, Yun-Chan Hwang,
More informationDOI: /JKACD Basic research FRC- 포스트의표면처리가레진시멘트와의접착력에미치는영향 박찬현 박세희 김진우 조경모 * 강릉원주대학교치과대학치과보존학교실 ABSTRACT Effect of surface treatme
DOI: 10.5395/JKACD.2011.36.2.125 FRC- 포스트의표면처리가레진시멘트와의접착력에미치는영향 박찬현 박세희 김진우 조경모 * 강릉원주대학교치과대학치과보존학교실 ABSTRACT Effect of surface treatment of FRC-Post on bonding strength to resin cements Chan-Hyun Park,
More information수산화칼슘적용에따른상아질접착제의접착강도변화에관한연구 었다. 그러나새로운제품들이개발되면서글래스아이오노머시멘트와함께이장재로서사용빈도가증가되고있다. 즉이는수산화칼슘제재가상아질의광화를유도하며 16), 잔존상아질의재광화를촉진하고살균효과때문에노출치수의복조재로도사용이추천되고있다.
대한치과보존학회지 : Vol. 32, No. 3, 2007 수산화칼슘적용에따른상아질접착제의접착강도변화에관한연구 박노훈 박상혁 최기운 박상진 * 경희대학교대학원치의학과치과보존학교실 ABSTRACT EFFECT OF CALCIUM HYDROXIDE ON BOND STRENGTH OF DENTIN BONDING SYSTEMS No-Hoon Park, Sang-Hyuk
More information레진코팅된상아질표면과레진인레이간결합에임시가봉재가미치는영향 레진코팅된상아질표면과레진인레이간결합에임시가봉재가미치는영향 김태균 이광원 유미경 * 전북대학교치의학전문대학원치과보존학교실 ABSTRACT THE EFFECT OF TEMPORARY FILLING MATERIALS
김태균 이광원 유미경 * 전북대학교치의학전문대학원치과보존학교실 ABSTRACT THE EFFECT OF TEMPORARY FILLING MATERIALS ON THE ADHESION BETWEEN DENTIN ADHESIVE-COATED SURFACE AND RESIN INLAY Tae-Gun Kim, Kwang-Won Lee, Mi-Kyung Yu* Department
More informationJournal of Educational Innovation Research 2017, Vol. 27, No. 2, pp DOI: : Researc
Journal of Educational Innovation Research 2017, Vol. 27, No. 2, pp.251-273 DOI: http://dx.doi.org/10.21024/pnuedi.27.2.201706.251 : 1997 2005 Research Trend Analysis on the Korean Alternative Education
More informationÆ÷Àå½Ã¼³94š
Cho, Mun Jin (E-mail: mjcho@ex.co.kr) ABSTRACT PURPOSES : The performance of tack coat, commonly used for layer interface bonding, is affected by application rate and curing time. In this study, bonding
More informationDBPIA-NURIMEDIA
The e-business Studies Volume 17, Number 6, December, 30, 2016:237~251 Received: 2016/11/20, Accepted: 2016/12/24 Revised: 2016/12/21, Published: 2016/12/30 [ABSTRACT] Recently, there is an increasing
More information012임수진
Received : 2012. 11. 27 Reviewed : 2012. 12. 10 Accepted : 2012. 12. 12 A Clinical Study on Effect of Electro-acupuncture Treatment for Low Back Pain and Radicular Pain in Patients Diagnosed with Lumbar
More informationORIGINAL ARTICLE CAD/CAM 세라믹인레이에대한 3 종의레진시멘트의전단결합강도에관한연구 백철우 1 박철우 1 박준섭 2 류재준 1 * 1 고려대학교임상치의학대학원심미수복학과,
ORIGINAL ARTICLE http://dx.doi.org/10.4047/jkap.2013.51.1.20 백철우 1 박철우 1 박준섭 2 류재준 1 * 1 고려대학교임상치의학대학원심미수복학과, 2 굿윌치과병원 Shear bond strength of the three different kinds of resin cement on CAD/CAM ceramic
More information<4D F736F F D20B1E8BCB1C0CFBCAEBBE7C3D6C1BE>
CAD/CAM 세라믹의두께및 레진시멘트의종류에따른 접착강도비교 연세대학교대학원 치의학과 김선일 CAD/CAM 세라믹의두께및 레진시멘트의종류에따른 접착강도비교 지도노병덕교수 이논문을석사학위논문으로제출함 2010 년 6 월일 연세대학교대학원 치의학과 김선일 김선일의석사학위논문을인준함 심사위원 심사위원 심사위원 인 인 인 연세대학교대학원 2010 년 6 월일 감사의글
More informationJournal of Educational Innovation Research 2017, Vol. 27, No. 2, pp DOI: * Review of Research
Journal of Educational Innovation Research 2017, Vol. 27, No. 2, pp.79-102 DOI: http://dx.doi.org/10.21024/pnuedi.27.2.201706.79 * Review of Research Trends on Curriculum for Students with Severe and multiple
More information<283732372D3733312920B4D9C3CAC1A120BCD2C7C1C6AEC4DCC5C3C6AEB7BBC1EEC0C720B3EBBEC8C0C720BDC3B7C2BAB8C1A4BFA120B4EBC7D120C0AFBFEBBCBA20C6F2B0A1283035292E687770>
대한안과학회지 제 49 권 제 5 호 2008 J Korean Ophthalmol Soc 49(5):727-731, 2008 DOI : 10.3341/jkos.2008.49.5.727 다초점 소프트콘택트렌즈의 노안의 시력보정에 대한 유용성 평가 김현경 1 김효명 2 정성근 1 가톨릭대학교 의과대학 성모병원 안과학교실 1, 고려대학교 의과대학 안암병원 안과학교실
More information한국성인에서초기황반변성질환과 연관된위험요인연구
한국성인에서초기황반변성질환과 연관된위험요인연구 한국성인에서초기황반변성질환과 연관된위험요인연구 - - i - - i - - ii - - iii - - iv - χ - v - - vi - - 1 - - 2 - - 3 - - 4 - 그림 1. 연구대상자선정도표 - 5 - - 6 - - 7 - - 8 - 그림 2. 연구의틀 χ - 9 - - 10 - - 11 -
More information대한치과보존학회지 : Vol. 35, No. 2, 2010 복합레진의 exponential 중합법이상아질접착제의미세인장접착강도에미치는영향 성소래 서덕규 이인복 손호현 조병훈 * 서울대학교치의학대학원치과보존학교실 ABSTRACT EFFECT OF THE EXPONENTI
성소래 서덕규 이인복 손호현 조병훈 * 서울대학교치의학대학원치과보존학교실 ABSTRACT EFFECT OF THE EXPONENTIAL CURING OF COMPOSITE RESIN ON THE MICROTENSILE DENTIN BOND STRENGTH OF ADHESIVES So-Rae Seong, Duck-kyu Seo, In-Bog Lee, Ho-Hyun
More information12.077~081(A12_이종국).fm
J. of Advanced Engineering and Technology Vol. 1, No. 1 (2008) pp. 77-81 y w» e wx Á w œw Fabrication of Ceramic Batch Composition for Porcelain by Using Recycled Waste Ceramic Powder Hyun Guen Han, and
More informationLumbar spine
Lumbar spine CT 32 111 DOI : 10.3831/KPI.2010.13.2.111 Lumbar Spine CT 32 Received : 10. 05. 23 Revised : 10. 06. 04 Accepted : 10. 06. 11 Key Words: Disc herniation, CT scan, Clinical analysis The Clinical
More information멘트의개발이있어왔으나, 레진강화형글라스아이오노머시멘트에관한연구는많지않으며, 특히합착용시멘트의전단결합강도에영향을줄수있는요인중치면의산처리에관한연구는거의이루어지지않았다. 이에본연구에서는최근임상에서널리사용되고있는레진강화형글라스아이오노머시멘트를대상으로결합력을향상시키기위한다양한방
대한치과보철학회지 :Vol. 39, No. 5, 2001 상아질의치면처리에따른합착용레진강화형글라스아이오노머시멘트의전단결합강도 경북대학교치과대학보철학교실 최혜숙 이청희 조광헌 Ⅰ. 서론 1972년 Wilson과 Kent 1) 에의해소개된자가중합형글라스아이오노머시멘트는치질과의화학적결합, 생체적합성, 불소유리로인한항우식작용, 치질과유사한열팽창계수, 합착제로서의강도와견고성등의장점을가지며합착용시멘트로널리이용되어왔으나,
More information- i - - ii - - iii - - iv - - v - - 1 - - 2 - - 3 - - 4 - - 5 - - 6 - - 7 - - 8 - - 9 - - 10 - - 11 - - 12 - - 13 - - 14 - - 15 - - 16 - - 17 - - 18 - - 19 - α α - 20 - α α α α α α - 21 - - 22 - - 23 -
More information歯1.PDF
200176 .,.,.,. 5... 1/2. /. / 2. . 293.33 (54.32%), 65.54(12.13%), / 53.80(9.96%), 25.60(4.74%), 5.22(0.97%). / 3 S (1997)14.59% (1971) 10%, (1977).5%~11.5%, (1986)
More information저작자표시 - 비영리 - 변경금지 2.0 대한민국 이용자는아래의조건을따르는경우에한하여자유롭게 이저작물을복제, 배포, 전송, 전시, 공연및방송할수있습니다. 다음과같은조건을따라야합니다 : 저작자표시. 귀하는원저작자를표시하여야합니다. 비영리. 귀하는이저작물을영리목적으로이용할
저작자표시 - 비영리 - 변경금지 2.0 대한민국 이용자는아래의조건을따르는경우에한하여자유롭게 이저작물을복제, 배포, 전송, 전시, 공연및방송할수있습니다. 다음과같은조건을따라야합니다 : 저작자표시. 귀하는원저작자를표시하여야합니다. 비영리. 귀하는이저작물을영리목적으로이용할수없습니다. 변경금지. 귀하는이저작물을개작, 변형또는가공할수없습니다. 귀하는, 이저작물의재이용이나배포의경우,
More information저작자표시 - 비영리 - 변경금지 2.0 대한민국 이용자는아래의조건을따르는경우에한하여자유롭게 이저작물을복제, 배포, 전송, 전시, 공연및방송할수있습니다. 다음과같은조건을따라야합니다 : 저작자표시. 귀하는원저작자를표시하여야합니다. 비영리. 귀하는이저작물을영리목적으로이용할
저작자표시 - 비영리 - 변경금지 2.0 대한민국 이용자는아래의조건을따르는경우에한하여자유롭게 이저작물을복제, 배포, 전송, 전시, 공연및방송할수있습니다. 다음과같은조건을따라야합니다 : 저작자표시. 귀하는원저작자를표시하여야합니다. 비영리. 귀하는이저작물을영리목적으로이용할수없습니다. 변경금지. 귀하는이저작물을개작, 변형또는가공할수없습니다. 귀하는, 이저작물의재이용이나배포의경우,
More informationORIGINAL ARTICLE 지르코니아세라믹의표면처리에따른치과용접착제의전단결합강도 김지혜 서재민 안승근 박주미 송광엽 * 전북대학교치의학전문대학원치과보철학교실및구강생체과학연구소 The ef
ORIGINAL ARTICLE http://dx.doi.org/10.4047/jkap.2013.51.2.73 김지혜 서재민 안승근 박주미 송광엽 * 전북대학교치의학전문대학원치과보철학교실및구강생체과학연구소 The effect of surface treatment conditioning on shear bond strength between zirconia and
More information도말층존재유무에따른 One-step 접착시스템의미세인장결합강도 도말층존재유무에따른 One-step 접착시스템의미세인장결합강도 송용범 진정희 이세준 이광원전북대학교치과대학치과보존학교실및구강생체과학연구소 ABSTRACT MICROTENSILE BONDING OF ONE-S
송용범 진정희 이세준 이광원전북대학교치과대학치과보존학교실및구강생체과학연구소 ABSTRACT MICROTENSILE BONDING OF ONE-STEP ADHESIVES TO SMEARED AND NON-SMEARED DENTIN Yong-Beom Song, Jin-Jeong Hee, Se-Joon Lee, Kwang-Won Lee Department of Conservative
More information???? 1
The Korean Journal of Applied Statistics (2014) 27(1), 13 20 DOI: http://dx.doi.org/10.5351/kjas.2014.27.1.013 Maximum Tolerated Dose Estimation by Stopping Rule and SM3 Design in a Phase I Clinical Trial
More informationDBPIA-NURIMEDIA
The e-business Studies Volume 17, Number 6, December, 30, 2016:275~289 Received: 2016/12/02, Accepted: 2016/12/22 Revised: 2016/12/20, Published: 2016/12/30 [ABSTRACT] SNS is used in various fields. Although
More informationKor. J. Aesthet. Cosmetol., 및 자아존중감과 스트레스와도 밀접한 관계가 있고, 만족 정도 에 따라 전반적인 생활에도 영향을 미치므로 신체는 갈수록 개 인적, 사회적 차원에서 중요해지고 있다(안희진, 2010). 따라서 외모만족도는 개인의 신체는 타
RESEARCH ARTICLE Kor. J. Aesthet. Cosmetol., 20-40대 여성의 외모만족도가 미용관리태도에 미치는 영향 홍수남 1, 김효숙 2 * 1 건국대학교 뷰티사이언스디자인학과, 2 건국대학교 의상디자인과 Effects of Extrinsic Body Satisfaction on Beauty Management Behavior of
More information00....
Fig. 1 2.5%. 51.5%, 46.0%,.. /, Table 1 (U.V.; Ultraviolet 10-400 nm)/ (NIR; Near Infrared 700 nm - 5 µm) ( TiO 2, WO 3, ZnO, CeO, ATO, Sb 2O 3-ZnO, ITO.) (400 nm - 780 nm). /. Fig. 1.. 23 Table 1. / /
More informationJ Korean Acad Pediatr Dent 39(4) 2012 광을받고있으며이를뒷받침하는많은연구들이발표되고있다. 저자는새로개발된유동성자이오머의물성이기존유동성복합레진에어느정도근접했는지에초점을맞추고압축강도와표면미세경도를측정한후비교분석하여다소의지견을얻었기에보고하는바이다
http://dx.doi.org/10.5933/jkapd.2012.39.4.383 대한소아치과학회지 39(4) 2012 유동성자이오머와복합레진의압축강도및표면미세경도비교 김종수 단국대학교치과대학소아치과학교실 국문초록본연구의목적은유동성자이오머인 Beautifil flow와유동성복합레진인 Filtek TM Z350, Z350XT의압축강도와표면미세경도를비교평가하는것이었다.
More information10(3)-10.fm
w y wz 10«3y 259~264 (2010.12.) Journal of Korean Society of Urban Environment w gj p p y Á Á½k * w m œw Á* w y œw (2010 9 28, 2010 10 12 k) Characteristics of Antiwashout Underwater Concrete for Reduction
More information- iii - - i - - ii - - iii - 국문요약 종합병원남자간호사가지각하는조직공정성 사회정체성과 조직시민행동과의관계 - iv - - v - - 1 - - 2 - - 3 - - 4 - - 5 - - 6 - - 7 - - 8 - - 9 - - 10 - - 11 - - 12 - - 13 - - 14 - α α α α - 15 - α α α α α α
More informationePapyrus PDF Document
.130-812 103-18 02-2253-2800 02-2253-2809 kdtech@chol.com 370 2013 10 1 1977 11 20 Korean Dental Technologist Association News, 45 8 30. 6 27 2 2. ( ),,,,,,,,,, 13.,,., ( ) 40. 9 27 45 9 27 45 6. (1,272
More informationAlloy Group Material Al 1000,,, Cu Mg 2000 ( 2219 ) Rivet, Mn 3000 Al,,, Si 4000 Mg 5000 Mg Si 6000, Zn 7000, Mg Table 2 Al (%
http://wwwtechnonetcokr (Aluminum & Aluminum BasedAlloy) : LG 1 Aluminum Table 1, 2 1000 7000 4 Al 990% Al 1XXX AlCu 2XXX AlMn 3XXX AlSi 4XXX AlMg 5XXX AlMgSi 6XXX AlZn(Mg, Cu) 7XXX 8XXX ( ) 9XXX Fig 1
More information대한치과보존학회지 : Vol. 31, No. 5, 2006 수복물의미세누출도와변연적합도측정에사용되는방법사이의상관관계평가 황순주 신동훈 * 단국대학교치과대학치과보존학교실 ABSTRACT ESTIMATION OF RELATION BETWEEN TECHNIQUES OF DY
황순주 신동훈 * 단국대학교치과대학치과보존학교실 ABSTRACT ESTIMATION OF RELATION BETWEEN TECHNIQUES OF DYE PENETRATION FOR MICROLEA- KAGE AND SEM EVALUATION FOR MARGINAL ADAPTATION OF THE RESTORATION Soon-Joo Hwang, Dong-Hoon
More information대한치과보존학회지 : Vol. 31, No. 4, 2006 접착제와와동형성의차이에따른 5 급복합레진수복의전향적임상연구 이경욱 1 정세준 1 한영철 1 손호현 1,2 엄정문 1,2 오명환 3 조병훈 1,2 * 1 서울대학교치과대학치과보존학교실, 2 치학연구소, 3 ㄜ베리
대한치과보존학회지 : Vol. 31, No. 4, 2006 이경욱 1 정세준 1 한영철 1 손호현 1,2 엄정문 1,2 오명환 3 조병훈 1,2 * 1 서울대학교치과대학치과보존학교실, 2 치학연구소, 3 ㄜ베리콤기술연구소 ABSTRACT PROSPECTIVE CLINICAL EVALUATION OF THREE DIFFERENT BONDING SYSTEMS IN
More information원위부요척골관절질환에서의초음파 유도하스테로이드주사치료의효과 - 후향적 1 년경과관찰연구 - 연세대학교대학원 의학과 남상현
원위부요척골관절질환에서의초음파 유도하스테로이드주사치료의효과 - 후향적 1 년경과관찰연구 - 연세대학교대학원 의학과 남상현 원위부요척골관절질환에서의초음파 유도하스테로이드주사치료의효과 - 후향적 1 년경과관찰연구 - 연세대학교대학원 의학과 남상현 원위부요척골관절질환에서의초음파 유도하스테로이드주사치료의효과 - 후향적 1 년경과관찰연구 - 지도김석원교수 이논문을석사학위논문으로제출함
More information1..
Volume 12, Number 1, 6~16, Factors influencing consultation time and waiting time of ambulatory patients in a tertiary teaching hospital Jee-In Hwang College of Nursing Science, Kyung Hee University :
More information대한치과보존학회지 : Vol. 33, No. 6, 2008 다양한레진시멘트로합착한섬유포스트의결합강도비교 이현아 조영곤 * 조선대학교치과대학치과보존학교실 ABSTRACT COMPARISON OF BOND STRENGTH OF A FIBER POST CEMENTED WIT
이현아 조영곤 * 조선대학교치과대학치과보존학교실 ABSTRACT COMPARISON OF BOND STRENGTH OF A FIBER POST CEMENTED WITH VARIOUS RESIN CEMENTS Hyun-A Lee, Young-Gon Cho* Department of Conservative Dentistry, College of Dentistry,
More information저작자표시 - 비영리 - 변경금지 2.0 대한민국 이용자는아래의조건을따르는경우에한하여자유롭게 이저작물을복제, 배포, 전송, 전시, 공연및방송할수있습니다. 다음과같은조건을따라야합니다 : 저작자표시. 귀하는원저작자를표시하여야합니다. 비영리. 귀하는이저작물을영리목적으로이용할
저작자표시 - 비영리 - 변경금지 2.0 대한민국 이용자는아래의조건을따르는경우에한하여자유롭게 이저작물을복제, 배포, 전송, 전시, 공연및방송할수있습니다. 다음과같은조건을따라야합니다 : 저작자표시. 귀하는원저작자를표시하여야합니다. 비영리. 귀하는이저작물을영리목적으로이용할수없습니다. 변경금지. 귀하는이저작물을개작, 변형또는가공할수없습니다. 귀하는, 이저작물의재이용이나배포의경우,
More information27 2, 1-16, * **,,,,. KS,,,., PC,.,,.,,. :,,, : 2009/08/12 : 2009/09/03 : 2009/09/30 * ** ( :
27 2, 1-16, 2009. * **,,,,. KS,,,., PC,.,,.,,. :,,, : 2009/08/12 : 2009/09/03 : 2009/09/30 * ** (: jjhkim@cau.ac.kr) 2 한국교육문제연구제 27 권 2 호, 2009 Ⅰ.,. 2008 3,536, 10 99.9% (, 2008). PC,, (, 2007). (, 2008),.,
More informationISSN eissn Original Article Chemical compatibility of interim material and bonding ag
https://doi.org/10.14368/jdras.2016.32.4.293 ISSN 2384-4353 eissn 2384-4272 Original Article Chemical compatibility of interim material and bonding agent on shear bond strength Jonghyuk Lee* Department
More informationA Study on Married Female Immigrants Life Style and Marriage Satisfaction in Terms of Preparing Their Old Age in Chungcheongnam-do Department of Gerontology, Hoseo University Doctoral Student : Hi Ran
More information歯전용]
2001. 9. 6 1. 1. (1) (1) 1 (2) (2) 2 3 INVESTER PROFESIONAL ORGANIZATION GOVERNMENT CODE COMMITTEE SPECIFICATION CODE LAW LICENSE PERMIT PLANT 4 5 6 7 2. (1) 2. (1) 8 9 (2) (2) 10 (3) ( ). () 20kg/ (P70,
More information27 2, 17-31, , * ** ***,. K 1 2 2,.,,,.,.,.,,.,. :,,, : 2009/08/19 : 2009/09/09 : 2009/09/30 * 2007 ** *** ( :
27 2, 17-31, 2009. -, * ** ***,. K 1 2 2,.,,,.,.,.,,.,. :,,, : 2009/08/19 : 2009/09/09 : 2009/09/30 * 2007 ** *** (: dminkim@cau.ac.kr) 18 한국교육문제연구제 27 권 2 호, 2009. Ⅰ. (,,, 2004). (,, 2006).,,, (Myrick,
More information서론 34 2
34 2 Journal of the Korean Society of Health Information and Health Statistics Volume 34, Number 2, 2009, pp. 165 176 165 진은희 A Study on Health related Action Rates of Dietary Guidelines and Pattern of
More information저작자표시 2.0 대한민국 이용자는아래의조건을따르는경우에한하여자유롭게 이저작물을복제, 배포, 전송, 전시, 공연및방송할수있습니다. 이차적저작물을작성할수있습니다. 이저작물을영리목적으로이용할수있습니다. 다음과같은조건을따라야합니다 : 저작자표시. 귀하는원저작자를표시하여야합니
저작자표시 2.0 대한민국 이용자는아래의조건을따르는경우에한하여자유롭게 이저작물을복제, 배포, 전송, 전시, 공연및방송할수있습니다. 이차적저작물을작성할수있습니다. 이저작물을영리목적으로이용할수있습니다. 다음과같은조건을따라야합니다 : 저작자표시. 귀하는원저작자를표시하여야합니다. 귀하는, 이저작물의재이용이나배포의경우, 이저작물에적용된이용허락조건을명확하게나타내어야합니다.
More information(Exposure) Exposure (Exposure Assesment) EMF Unknown to mechanism Health Effect (Effect) Unknown to mechanism Behavior pattern (Micro- Environment) Re
EMF Health Effect 2003 10 20 21-29 2-10 - - ( ) area spot measurement - - 1 (Exposure) Exposure (Exposure Assesment) EMF Unknown to mechanism Health Effect (Effect) Unknown to mechanism Behavior pattern
More information- i - - ii - - iii - - iv - - v - - vi - - 1 - - 2 - - 3 - 1) 통계청고시제 2010-150 호 (2010.7.6 개정, 2011.1.1 시행 ) - 4 - 요양급여의적용기준및방법에관한세부사항에따른골밀도검사기준 (2007 년 11 월 1 일시행 ) - 5 - - 6 - - 7 - - 8 - - 9 - - 10 -
More information878 Yu Kim, Dongjae Kim 지막 용량수준까지도 멈춤 규칙이 만족되지 않아 시행이 종료되지 않는 경우에는 MTD의 추정이 불가 능하다는 단점이 있다. 최근 이 SM방법의 단점을 보완하기 위해 O Quigley 등 (1990)이 제안한 CRM(Continu
한 국 통 계 학 회 논 문 집 2012, 19권, 6호, 877 884 DOI: http://dx.doi.org/10.5351/ckss.2012.19.6.877 Maximum Tolerated Dose Estimation Applied Biased Coin Design in a Phase Ⅰ Clinical Trial Yu Kim a, Dongjae Kim
More informationORIGINAL ARTICLE Fiber reinforced composite post 의표면처리에따른접착강도 노현식 노관태 우이형 배아란 * 경희대학교치의학전문대학원치의학과치과보철학교실
ORIGINAL ARTICLE http://dx.doi.org/10.4047/jkap.2014.52.2.113 노현식 노관태 우이형 배아란 * 경희대학교치의학전문대학원치의학과치과보철학교실 Retentive bond strength of fiber-reinforced composite posts cemented with different surface treatments
More informationµµÅ¥¸àÆ®1
Quintessence of Dental Technology Vol. 24, No. 6, JUNE 1999 6/99 Journal for Dental Technicians & Prosthodontists Quintessence of Dental Technology QDT 3 9 16 26 36 52 CONTENTS June volume24 No. 6 1999
More information달생산이 초산모 분만시간에 미치는 영향 Ⅰ. 서 론 Ⅱ. 연구대상 및 방법 達 은 23) 의 丹 溪 에 최초로 기 재된 처방으로, 에 복용하면 한 다하여 난산의 예방과 및, 등에 널리 활용되어 왔다. 達 은 이 毒 하고 는 甘 苦 하여 氣, 氣 寬,, 結 의 효능이 있
대한한방부인과학회지 THE JOURNAL OF ORIENTAL OBSTETRICS & GYNECOLOGY VOL.17, NO.2 : 115-122 (2004) 달생산이 초산모 분만시간에 미치는 영향 * 북경한의원, ** 윤산부인과의원, *** 최은림산부인과의원, 상지대학교 한의과대학 부인과학교실 ****, 경희대학교 동서의학대학원 김성준 *****, 윤왕준
More information저작자표시 - 비영리 - 변경금지 2.0 대한민국 이용자는아래의조건을따르는경우에한하여자유롭게 이저작물을복제, 배포, 전송, 전시, 공연및방송할수있습니다. 다음과같은조건을따라야합니다 : 저작자표시. 귀하는원저작자를표시하여야합니다. 비영리. 귀하는이저작물을영리목적으로이용할
저작자표시 - 비영리 - 변경금지 2.0 대한민국 이용자는아래의조건을따르는경우에한하여자유롭게 이저작물을복제, 배포, 전송, 전시, 공연및방송할수있습니다. 다음과같은조건을따라야합니다 : 저작자표시. 귀하는원저작자를표시하여야합니다. 비영리. 귀하는이저작물을영리목적으로이용할수없습니다. 변경금지. 귀하는이저작물을개작, 변형또는가공할수없습니다. 귀하는, 이저작물의재이용이나배포의경우,
More information현대패션의 로맨틱 이미지에 관한 연구
한지닥섬유제품의인체생리반응및쾌적성평가 임순 Evaluation of Thermal Physiological Responses and Comfort in Dox Fabric Soon Im Professor, Dept. of Fashion Industry, Incheon National University This study performed the evaluation
More information<313630313032C6AFC1FD28B1C7C7F5C1DF292E687770>
양성자가속기연구센터 양성자가속기 개발 및 운영현황 DOI: 10.3938/PhiT.25.001 권혁중 김한성 Development and Operational Status of the Proton Linear Accelerator at the KOMAC Hyeok-Jung KWON and Han-Sung KIM A 100-MeV proton linear accelerator
More information[ 영어영문학 ] 제 55 권 4 호 (2010) ( ) ( ) ( ) 1) Kyuchul Yoon, Ji-Yeon Oh & Sang-Cheol Ahn. Teaching English prosody through English poems with clon
[ 영어영문학 ] 제 55 권 4 호 (2010) 775-794 ( ) ( ) ( ) 1) Kyuchul Yoon, Ji-Yeon Oh & Sang-Cheol Ahn. Teaching English prosody through English poems with cloned native intonation. The purpose of this work is to
More information- 대한치과보철학회지 Vol. 30 No. 1, 1992 - Core 와시멘트의종류가전부주조금관의유지력에미치는영향 원광대학교치과대학보철학교실 하점임 조혜원 동진근 < 목차 > Ⅰ. 서론 Ⅱ. 연구재료및방법 Ⅲ. 연구성적 Ⅳ. 총괄및고안 Ⅴ. 결론참고문헌영문초록 I. 서론 임상에서심한치아우식증이나외력에의해치관이많이파손된경우그수복술식은오랜동안치과보철영역의관심의대상이되어왔다.
More information歯5-2-13(전미희외).PDF
The Korean Journal of Counseling 2004, Vol. 5, No. 2, 423-434,. 4 5 18 9, 9.,,,,,.,,, t-.. :,,, (,, 1996),.,,. (, 2001),... 88 98 2000, 88 12.5%(250 )98 35.6%(712 )2.8 (,,, 2001) (Corresponding Author)
More informationfm
[ ] w wz DOI: 10.3740/MRSK.2009.19.12.692 Kor. J. Mater. Res. Vol. 19, No. 12 (2009) y INCONEL 718w Gas Tungsten Arc Welding» p sƒ ½»y Á *Á *Á y** ( ) d lj p wœq, *w wœ» q **( ) d lj p t Mechanical Properties
More information44-4대지.07이영희532~
A Spatial Location Analysis of the First Shops of Foodservice Franchise in Seoul Metropolitan City Younghee Lee* 1 1 (R) 0 16 1 15 64 1 Abstract The foodservice franchise is preferred by the founders who
More informationsystems: 이하 SEPS)은 프라이머를 도말층(smear layer)으로 덮힌 상아질에 15-20초정도 적용한 후 세척하 지 않고 접착레진을 바로 적용한다. 4) 프라이머에 함유된 유 기산과 산성 단량체는 상아질의 도말층을 강화시키며 동시 에 레진 단량체를 침투함
상아질 삭제기구가 자가부식 접착제의 결합강도에 미치는 효과 이영곤 문소라 조영곤* 조선대학교 치과대학 치과보존학교실 ABSTRACT EFFECT OF CUTTING INSTRUMENTS ON THE DENTIN BOND STRENGTH OF A SELF-ETCH ADHESIVE Young-Gon Lee, So-Ra Moon, Young-Gon Cho* Department
More information12(4) 10.fm
KIGAS Vol. 12, No. 4, December, 2008 (Journal of the Korean Institute of Gas) l x CNG» v m s w ½ Á y w» œw (2008 9 30, 2008 12 10, 2008 12 10 k) Numerical Analysis for Temperature Distribution and Thermal
More informationuntitled
[ ] œwz, 21«6y(2008) J. of the Korean Society for Heat Treatment, Vol. 21, No. 6, (2008) pp. 300~306 š y w p x*, **Á **Áy y* * ** w œ w œw, w» gœ Solid State Diffusion Brazing of the Aluminum Alloy Castings
More informationKAERIAR hwp
- i - - ii - - iii - - iv - - v - - vi - Photograph of miniature SiC p-n and Schottky diode detector Photograph SiC chip mounted on a standard electrical package Photograph of SiC neutron detector with
More informationDBPIA-NURIMEDIA
e- 비즈니스연구 (The e-business Studies) Volume 17, Number 1, February, 28, 2016:pp. 3~30 ISSN 1229-9936 (Print), ISSN 2466-1716 (Online) 원고접수일심사 ( 수정 ) 게재확정일 2016. 01. 08 2016. 01. 09 2016. 02. 25 ABSTRACT
More informationJournal of Educational Innovation Research 2017, Vol. 27, No. 1, pp DOI: NCS : G * The Analy
Journal of Educational Innovation Research 2017, Vol. 27, No. 1, pp.133-158 DOI: http://dx.doi.org/10.21024/pnuedi.27.1.201703.133 NCS : G * The Analysis of the Cognitive Level of Basic Job Skills of Specialized
More information조사연구 권 호 연구논문 한국노동패널조사자료의분석을위한패널가중치산출및사용방안사례연구 A Case Study on Construction and Use of Longitudinal Weights for Korea Labor Income Panel Survey 2)3) a
조사연구 권 호 연구논문 한국노동패널조사자료의분석을위한패널가중치산출및사용방안사례연구 A Case Study on Construction and Use of Longitudinal Weights for Korea Labor Income Panel Survey 2)3) a) b) 조사연구 주제어 패널조사 횡단면가중치 종단면가중치 선형혼합모형 일반화선형혼 합모형
More information( )Kjhps043.hwp
Difference of Fistula Maturation Degree and Physical Property by the Types of Tube Material: An Experimental Study Sang Koo Kang, M.D. 1, Hee Chul Yu, M.D. 1,4, Woo Sung Moon, M.D. 2,4, Ju Hyoung Lee,
More informationORIGINAL ARTICLE 다용도프라이머가레진시멘트와수복재의전단결합강도에미치는영향 김나홍 심준성 문홍석 이근우 * 연세대학교치과대학치과보철학교실 연구목적 : 이연구의목적은실란과인산모노머
ORIGINAL ARTICLE http://dx.doi.org/.447/jkap.12..2.112 김나홍 심준성 문홍석 이근우 * 연세대학교치과대학치과보철학교실 연구목적 : 이연구의목적은실란과인산모노머를혼합한프라이머인 Monobond plus (Ivoclar Vivadent, Schaan, Liechtenstein) 를사용했을때레진시멘트와수복물간의전단결합강도가귀금속,
More information14.531~539(08-037).fm
G Journal of the Korea Concrete Institute Vol. 20, No. 4, pp. 531~539, August, 2008 š x y w m š gj p { sƒ z 1) * 1) w w Evaluation of Flexural Strength for Normal and High Strength Concrete with Hooked
More informationSEM 과 3 차원재구성법을이용한수복면의위치와와동크기에따른미세누출도분석 고있어이에따른응력발생으로인하여접착계면이분리되어미세누출이발생하는문제점을수반하고있다. 이러한수복물변연부의미세누출은술후과민증, 세균및이물질침투에따른치수자극, 2차우식증등을유발하며수복물의내구성을좌우하는것으
SEM과 3차원재구성법을이용한수복면의위치와와동크기에따른미세누출도분석 양인서 신동훈 * 단국대학교치과대학치과보존학교실 ABSTRACT MICROLEAKAGE OF THE CLASS V CAVITY ACCORDING TO RESTORATION SITE AND CAVITY SIZE USING SEM AND THREE-DIMENSIONAL RECONSTRUCTION
More informationDBPIA-NURIMEDIA
The e-business Studies Volume 17, Number 6, December, 30, 2016:21~34 Received: 2016/12/04, Accepted: 2016/12/27 Revised: 2016/12/19, Published: 2016/12/30 [ABSTRACT] With the development of the Internet,
More information03-서연옥.hwp
농업생명과학연구 49(4) pp.31-37 Journal of Agriculture & Life Science 49(4) pp.31-37 Print ISSN 1598-5504 Online ISSN 2383-8272 http://dx.doi.org/10.14397/jals.2015.49.4.31 국가산림자원조사 자료를 적용한 충남지역 사유림경영율 추정 서연옥
More information139~144 ¿À°ø¾àħ
2 139 DOI : 10.3831/KPI.2010.13.2.139 2 Received : 10. 04. 08 Revised : 10. 04. 26 Two Case Report on Wrist Ganglion Treated with Scolopendrid Pharmacopuncture Accepted : 10. 05. 04 Key Words: Wrist Ganglion,
More information歯14.양돈규.hwp
: The Korean Journal of Counseling and Psychotherapy 2003. Vol. 15, No. 3, 615-631. 1 2 3 1,410.,, ( ),., ( 69%),.,, ( ), ( ).,,.., ( ).,. :,,. :, (390-711) 21-1, : 043-649-1362 E-mail : ydk9498@hanmail.net
More informationAbstract Musculoskeletal Symptoms and Related Factors for Nurses and Radiological Technologists Wearing a Lead Apron for Radiation Pro t e c t i o n Jung-Im Yoo, Jung-Wan Koo 1 ) Angio Unit, Team of Radiology,
More informationAnalyses the Contents of Points per a Game and the Difference among Weight Categories after the Revision of Greco-Roman Style Wrestling Rules Han-bong
Analyses the Contents of Points per a Game and the Difference among Weight Categories after the Revision of Greco-Roman Style Wrestling Rules Han-bong An 1 & Kyoo-jeong Choi 2 * 1 Korea National Wrestling
More informationJournal of Educational Innovation Research 2017, Vol. 27, No. 1, pp DOI: * The
Journal of Educational Innovation Research 2017, Vol. 27, No. 1, pp.243-268 DOI: http://dx.doi.org/10.21024/pnuedi.27.1.201703.243 * - 2001 2015 - The Research Trends on Peer Counseling in Elementary and
More information..................
ptical & Mechanical Characteristics of Lining Papers Oby the Artificial Heat Ageing Treatment 1 1 This study was carried out to investigate the effect of artificial accelerated ageing treatment on the
More informationKor. J. Aesthet. Cosmetol., 라이프스타일은 개인 생활에 있어 심리적 문화적 사회적 모든 측면의 생활방식과 차이 전체를 말한다. 이러한 라이프스 타일은 사람의 내재된 가치관이나 욕구, 행동 변화를 파악하여 소비행동과 심리를 추측할 수 있고, 개인의
RESEARCH ARTICLE Kor. J. Aesthet. Cosmetol., 한국 중년 여성의 라이프스타일이 메이크업 추구이미지와 화장품 구매행동에 미치는 영향 주영주 1 *, 이순희 2 1 서경대학교대학원미용예술학과, 2 신성대학교 미용예술계열 The Effects of The Life Style for Korean Middle Aged Women on
More informationγ
경락경혈학회지 Vol.27, No.1, pp.87 106, 2010 Journal of Meridian & Acupoint Dept. of 1 Meridian & Acupoint, 3 Acupuncture & Moxibustion, College of Oriental Medicine, Daejeon University 2 Division of Clinical
More information농학석사학위논문 폴리페닐렌설파이드복합재료의기계적및열적 특성에영향을미치는유리섬유 환원된 그래핀옥사이드복합보강재에관한연구 The combined effect of glass fiber/reduced graphene oxide reinforcement on the mecha
저작자표시 - 비영리 - 변경금지 2.0 대한민국 이용자는아래의조건을따르는경우에한하여자유롭게 이저작물을복제, 배포, 전송, 전시, 공연및방송할수있습니다. 다음과같은조건을따라야합니다 : 저작자표시. 귀하는원저작자를표시하여야합니다. 비영리. 귀하는이저작물을영리목적으로이용할수없습니다. 변경금지. 귀하는이저작물을개작, 변형또는가공할수없습니다. 귀하는, 이저작물의재이용이나배포의경우,
More information저작자표시 - 비영리 - 변경금지 2.0 대한민국 이용자는아래의조건을따르는경우에한하여자유롭게 이저작물을복제, 배포, 전송, 전시, 공연및방송할수있습니다. 다음과같은조건을따라야합니다 : 저작자표시. 귀하는원저작자를표시하여야합니다. 비영리. 귀하는이저작물을영리목적으로이용할
저작자표시 - 비영리 - 변경금지 2.0 대한민국 이용자는아래의조건을따르는경우에한하여자유롭게 이저작물을복제, 배포, 전송, 전시, 공연및방송할수있습니다. 다음과같은조건을따라야합니다 : 저작자표시. 귀하는원저작자를표시하여야합니다. 비영리. 귀하는이저작물을영리목적으로이용할수없습니다. 변경금지. 귀하는이저작물을개작, 변형또는가공할수없습니다. 귀하는, 이저작물의재이용이나배포의경우,
More informationmain.hwp
열화상 측정기를 이용한 안마의자의 인체 영향 평가 박세진, 구준모, 이현자 한국표준과학연구원 생활계측그룹 Evaluation of Massage Chair Effect on Human Body using Infrared Imaging/Radiometric Camera Se Jin Park, Jun Mo Koo, Hyun Ja Lee Human L ife Measurement
More information09권오설_ok.hwp
(JBE Vol. 19, No. 5, September 2014) (Regular Paper) 19 5, 2014 9 (JBE Vol. 19, No. 5, September 2014) http://dx.doi.org/10.5909/jbe.2014.19.5.656 ISSN 2287-9137 (Online) ISSN 1226-7953 (Print) a) Reduction
More information, ( ) 1) *.. I. (batch). (production planning). (downstream stage) (stockout).... (endangered). (utilization). *
, 40 12 (2006 6) 1) *.. I. (batch). (production planning). (downstream stage) (stockout).... (endangered). (utilization). * 40, 40 12 (EPQ; economic production quantity). (setup cost) (setup time) Bradley
More information01_60p_서천민속지_1장_최종_출력ff.indd
01 달 모양의 해안을 따라, 월하성 012 달 모양의 해안을 따라, 월하성 013 달 빛 아 래 신 선 이 노 는, 월 하 성 마 을 1장 달 모양의 해안을 따라, 월하성 초승달을 닮은 바닷가마을 월하성( 月 河 城 )이 위치한 충청남도 서천군( 舒 川 郡 )은 육지로는 동쪽으로 부 여군( 扶 餘 郡 ), 북쪽으로 보령시( 保 寧 市 )와 접하고 남쪽은 금강(
More informationJournal of Educational Innovation Research 2019, Vol. 29, No. 2, pp DOI: 3 * Effects of 9th
Journal of Educational Innovation Research 2019, Vol. 29, No. 2, pp.357-378 DOI: http://dx.doi.org/10.21024/pnuedi.29.2.201906.357 3 * Effects of 9th Grade Students Participation in Career Curriculum Cluster
More information54 한국교육문제연구제 27 권 2 호, I. 1.,,,,,,, (, 1998). 14.2% 16.2% (, ), OECD (, ) % (, )., 2, 3. 3
27 2, 53-70, 2009. (Nursing Home) * ** (Nursing Home). 5 50 5 2 1,,,,, SPSS t.,,,,,,,. :,, : 2009/08/27 : 2009/09/24 : 2009/09/30 * ** (: hjkim@daelim.ac.kr) 54 한국교육문제연구제 27 권 2 호, 2009. I. 1.,,,,,,, (,
More information다용도프라이머가 레진시멘트와수복재의 전단결합강도에미치는영향 연세대학교대학원 치의학과 김나홍
다용도프라이머가 레진시멘트와수복재의 전단결합강도에미치는영향 연세대학교대학원 치의학과 김나홍 다용도프라이머가 레진시멘트와수복재의 전단결합강도에미치는영향 지도교수이근우 이논문을석사학위논문으로제출함 2011 년 6 월일 연세대학교대학원 치의학과 김나홍 김나홍의석사학위논문을인준함 심사위원 심사위원 심사위원 인 인 인 연세대학교대학원 2011 년 6 월일 감사의글 이논문이완성되기까지끊임없는지도와격려,
More informationJ Korean Acad Pediatr Dent 41(2) 2014 ISSN (print) ISSN (online) Effect of Various S
http://dx.doi.org/10.5933/jkapd.2014.41.2.125 ISSN (print) 1226-8496 ISSN (online) 2288-3819 Effect of Various Surface Treatment Methods on Shear Bond Strength of Orthodontic Brackets to Aged Composite
More informationJournal of Educational Innovation Research 2018, Vol. 28, No. 4, pp DOI: 3 * The Effect of H
Journal of Educational Innovation Research 2018, Vol. 28, No. 4, pp.577-601 DOI: http://dx.doi.org/10.21024/pnuedi.28.4.201812.577 3 * The Effect of Home-based Activities Using Traditional Fairy Tales
More informationÆ÷Àå82š
Lee, Kyungbae (E-mail : kblee6078@ex.co.kr) Lee, Jaehoon (E-mail : ranian74@ex.co.kr) Sohn, Duecksu (E-mail : mgsds@ex.co.kr) Kwon, Soonmin (E-mail : soonmini2@ex.co.kr) ABSTRACT PURPOSES : The purpose
More informationJksvs019(8-15).hwp
Grade I Grade II Grade III 12 대한혈관외과학회지 : 제 20 권 제 1 호 2004 Control Group A Group B Fig. 4. Microscopic findings of vein wall in control, group A and group B on the day of 7 after venous occlusion. The
More information