Page 2 of 14 Absolute Maximum Ratings - Supply voltage : 5.5V - Operating Temperature Range : -20 ~ 70 - Storage Temperature Range : -40 ~ 85 위조건을넘어서게

Similar documents
Page 2 of 13 Absolute Maximum Ratings Absolute Maximum Rating 값을초과하는조건에서 DTPML을동작시킬경우치명적인손상을 가할수있습니다. Parameter Symbol Conditions min Typ Max Unit Sup

Page 2 of 13 Absolute Maximum Ratings - Supply voltage : 5.5V - Operating Temperature Range : -20 ~ 70 - Storage Temperature Range : -40 ~ 85 위조건을넘어서게

Page 2 of 12 Absolute Maximum Ratings Absolute Maximum Rating 값을초과하는조건에서 CT 을동작시킬경우치명적인손 상을가할수있습니다. Parameter Symbol Conditions min Typ Max Uni

Page 2 of 13 Absolute Maximum Ratings - Supply voltage : 5.5V - Operating Temperature Range : -20 ~ 70 - Storage Temperature Range : -40 ~ 85 위조건을넘어서게

Microsoft Word - DTPAL-UART-1604_Spec_V1.2.docx

Page 2 of 18 Absolute Maximum Ratings Absolute Maximum Rating 값을초과하는조건에서 DTPM을동작시킬경우치명적인손상을 가할수있습니다. Parameter Symbol Conditions min Typ Max Unit Supp

Page 2 of 20 Absolute Maximum Ratings - Supply voltage : 3.5V - Operating Temperature Range : -20 ~ 70 - Storage Temperature Range : -40 ~ 85 위조건을넘어서게

Microsoft Word - DTM-M300_Spec_V1_0.doc

DTS-L300-V2 Specification Page 1 of 14 비접촉온도측정 원거리온도측정 High Accuracy Digital Interface : SPI Arduino UNO 예제코드제공 제품설명 DTS-L300-V2는접촉을하지않고원하는물체표면에온도를 50

Formatvorlage für Arbeitsanweisungen

Page 2 of 21 Absolute Maximum Ratings Absolute Maximum Rating 값을초과하는조건에서 DTPML을동작시킬경우치명적인손상을 가할수있습니다. Parameter Symbol Conditions min Typ Max Unit Sup

Formatvorlage für Arbeitsanweisungen

-. Data Field 의, 개수, data 등으로구성되며, 각 에따라구성이달라집니다. -. Data 모든 의 data는 2byte로구성됩니다. Data Type는 Integer, Float형에따라다르게처리됩니다. ( 부호가없는 data 0~65535 까지부호가있는

Microsoft Word - FS_ZigBee_Manual_V1.3.docx

BY-FDP-4-70.hwp

SRC PLUS 제어기 MANUAL

T100MD+

Microsoft Word - DTPA-UART-3232_Spec_V1.4.docx

Page 2 of 27 Absolute Maximum Ratings - Supply voltage : 3.5V - Operating Temperature Range : -20 ~ 70 - Storage Temperature Range : -40 ~ 85 위조건을넘어서게

(SW3704) Gingerbread Source Build & Working Guide

MODBUS SERVO DRIVER( FDA7000 Series ) STANDARD PROTOCOL (Ver 1.00) 1

Page 2 of 9 PIN Definition 먼지흡입구 PIN Definition No Definition Description 1 NOP N/A 2 5V Power Supply Input (+5V) 3 NOP N/A 4 NOP N/A 5 GND GND 6 TX U

1. Features IR-Compact non-contact infrared thermometer measures the infrared wavelength emitted from the target spot and converts it to standard curr

untitled

untitled

[8051] 강의자료.PDF

Poison null byte Excuse the ads! We need some help to keep our site up. List 1 Conditions 2 Exploit plan 2.1 chunksize(p)!= prev_size (next_chunk(p) 3

4) CRC - 16bit MODBUS crc 4. MODBUS Exception Codes Code 01h 02h 03h 04h 05h 06h 10h 11h 12h 13h 14h Name ILLEGAL FUNCTION ILLEGAL DATA ADDRESS ILLEGA

DSP_MON 프로그램 메뉴얼

<4D F736F F F696E74202D20B8B6C0CCC5A9B7CEC7C1B7CEBCBCBCAD202834C1D6C2F7207E2038C1D6C2F729>

2

Preliminary spec(K93,K62_Chip_081118).xls

hd1300_k_v1r2_Final_.PDF

- 2 -


유량 MODBUS-RTU Protocol UlsoFlow시리즈초음파유량계는 MODBUS-ASCII와 MODBUS-RTU를지원한다. 여기서는 MODBUS-RTU를기준으로설명한다. 유량계의국번은 0 ~ 6,5535 까지지정할수있다. ( 단, 0, 10, 13, 38, 42

스마트주택용분전반_160331

Turbine Digital Flowmeter SEMI U+ 특징 PVC, PTFE, P.P, PVDF 등 다양한 재질 Size, 유량, Connection별 주문제작 정밀성, 내화학성이 우수 4~20mA, Alarm, 통신(RS485) 등 출력 제품과 Controll

INDUCTION MOTOR 표지.gul

CPX-E-PB_BES_C_ _ k1

REVERSIBLE MOTOR 표지.gul

Coriolis.hwp

(Asynchronous Mode) ( 1, 5~8, 1~2) & (Parity) 1 ; * S erial Port (BIOS INT 14H) - 1 -

1. 제품규격및특징 구분 규격및특징 입력전압 DC 12~30V 모터구동방식 Bipolar 방식 최대모터전류 Max 3.0A 초기설정정지전류 :4(0.46A), 구동전류 :18(1.75A) 분주비 0(x256), 1(x128), 2(x64), 3(x32), 4(x16),

개요

MAX+plus II Getting Started - 무작정따라하기

歯AG-MX70P한글매뉴얼.PDF

ez-shv manual

<4D F736F F D20B1E2BCFAC0DAB7E1202D20454F435220B8F0B5E5B9F6BDBA20C5EBBDC5C1A6C7B020BBE7BFEBB9FD202D F302E646F63>

<4D F736F F F696E74202D20B8B6C0CCC5A9B7CEC7C1B7CEBCBCBCAD202839C1D6C2F7207E203135C1D6C2F >

歯FDA6000COP.PDF

CONTENTS 1. Approval Revision Record Scope Numbering of product Product Part No Lot. No Absolu

KMC.xlsm

MR-3000A-MAN.hwp

CPX-E-EC_BES_C_ _ k1

한글사용설명서

슬라이드 제목 없음

hwp

CD-6208_SM(new)

< C6AFC1FD28B1C7C7F5C1DF292E687770>

Ultimate High Performance Audio tx-usb Operating Instructions Rev : 1.0

X-VA-MT3809G-MT3810G-kor

Vertical Probe Card Technology Pin Technology 1) Probe Pin Testable Pitch:03 (Matrix) Minimum Pin Length:2.67 High Speed Test Application:Test Socket

BS-K1217-M□□-3012_ProductGuide_KR_PDF

PD-659_SM(new)

목차 1. 제품 소개 특징 개요 Function table 기능 소개 Copy Compare Copy & Compare Erase

온습도 판넬미터(JTH-05) 사양서V1.0

untitled

Microsoft Word - PEB08_USER_GUIDE.doc

전자교탁 사양서.hwp


GLHPS-D

SEMI U+

SSi Super Systems Inc / DP RETURNING THE UNIT TO SSI 11 SPARE PARTS 12 APPENDIX A 13 APPENDIX B 14 Super System Inc DP2000

untitled

Microsoft PowerPoint - Ch13

BC6DX Korean.ai

Microsoft Word - Installation and User Manual_CMD V2.2_.doc

DWCOM15/17_manual

Microsoft Word - SMB-63-2_KR_.doc

(specifications) 3 ~ 10 (introduction) 11 (storage bin) 11 (legs) 11 (important operating requirements) 11 (location selection) 12 (storage bin) 12 (i

대경테크종합카탈로그

비트와바이트 비트와바이트 비트 (Bit) : 2진수값하나 (0 또는 1) 를저장할수있는최소메모리공간 1비트 2비트 3비트... n비트 2^1 = 2개 2^2 = 4개 2^3 = 8개... 2^n 개 1 바이트는 8 비트 2 2

?뗡뀶?믟뀱?솽꼶?듄꼮??

OSTSen-PIR100 사용자설명서 Ver 1.1 Onsystech OSTSen-PIR100 V1.1 1 of 8 Onsystech

YD-3533.xls

MIL-C-99 Class C, R Style Connector, Receptacle, lectrical, Wall mounting YH7(MS7 Style) PLCS 전기적특성 (lectrical ata) ltitude erating Service Rating Nom

RS- 232, RS485 FND Display Module NET-SFND-4-23A RS-232, RS485 FND Display Module NET-SFND-4-23A MANUAL (Rev 1.0) Net-Control http

목차 1. 개요 USB 드라이버 설치 (FTDI DRIVER) FTDI DRIVER 실행파일 USB 드라이버 확인방법 DEVICE-PROGRAMMER 설치 DEVICE-PROGRAMMER

DE1-SoC Board

Mango-IMX6Q mfgtool을 이용한 이미지 Write하기

Microsoft Word - SRA-Series Manual.doc

<4D F736F F F696E74202D20BBB7BBB7C7D15F FBEDFB0A3B1B3C0B05FC1A638C0CFC2F72E BC8A3C8AF20B8F0B5E55D>

5. Kapitel URE neu

Microsoft Word MetOne237Bmanual

(Table of Contents) 2 (Specifications) 3 ~ 10 (Introduction) 11 (Storage Bins) 11 (Legs) 11 (Important Operating Requirements) 11 (Location Selection)

OSTSen-THL100 사용자설명서 Ver 1.1 Onsystech OSTSen-THL100 Ver1.1 1 of 8 Onsystech

MicrocontrollerAcademy_Lab_ST_040709

901-(Twin)¿ë AB

Transcription:

Page 1 of 14 <DTPML-485-151> <DTPML-485-81> 비접촉온도측정 방사율조절가능 IR refresh rate : 50Hz 원거리온도측정 High Accuracy Digital Interface : RS485 MODBUS RTU ( Isolation Interface ) 레이저포인터기본장착 제품설명 DTPML-485 Series는온도계산프로세서를내장하고있어정확한온도값을출력합니다. (Master Controller에온도계산알고리즘이필요하지않습니다.) 방사율조절이가능합니다 ( 초기값 0.95ε 으로출하 ). DTPML-485 Series는디지털통신 (RS485) 으로온도값을출력합니다. 센서온도와대상온도를동시에측정합니다. 레이저포인터를장착하여측정방향을쉽게알수있습니다. Warning: This DTPML contains a class II laser device.(650nm) 특징 응용분야 8:1 모델측정온도구간 : -20 ~ 200 15:1 모델측정온도구간 : -20 ~ 270 동작온도구간 : -20 ~ 70 동작온도 ( 레이저 ) : -10 ~ 40 분해능 : 0.1 DTPML-485-81 DS ratio : 8:1 DTPML-485-151 DS ratio : 15:1 정확도 : ±2% 입력전압 : 5V 통신인터페이스 : RS485 MODBUS RTU 과열방지시스템 산업용온도측정장치 체온측정을통한인체감지 가전기기

Page 2 of 14 Absolute Maximum Ratings - Supply voltage : 5.5V - Operating Temperature Range : -20 ~ 70 - Storage Temperature Range : -40 ~ 85 위조건을넘어서게되면제품의수명을보장할수없습니다. 반드시아래 Electrical Requirements 를지켜주세요. Electrical Requirements Parameter Symbol Conditions min Typ Max Unit 공급전압 Vcc Measured versus GND 4.75 5 5.5 V 방사율 (Emission Coefficient) ε 0.1 0.95 1 소비전류 ( 5 V 기준 ) Full ambient temp. range, Typical value, no output load 21 ma On Laser 38 ma Operational Characteristics if not otherwise noted, 25 ambient temperature, 5V supply voltage and object with ε =0.95 were applied Parameter Symbol Conditions min Typ Max Unit DS ratio : DTPML-485-81 DTPML-485-151 8:1 15:1 온도측정범위 : DTPML-485-81 -20 200 Tobj DTPML-485-151 -20 270 동작온도 ( 주변온도 ) Tamb -20 70 동작온도 ( 레이저동작 ) -10 40 IR refresh rate 50 Hz 정확도 AccT ±2 % Resolution Digital 0.1 Standard Start-UP Time tstart 1 sec Stabilization Time tstab 1 min

Page 3 of 14 Mechanical Dimensions (DTPML-485-151) 단위 : mm < TOP View > < SIDE View > < BOTTOM View > 제품사진 (DTPML-485-151) < TOP View > < SIDE View > < BOTTOM View >

Page 4 of 14 Mechanical Dimensions (DTPML-485-81) 단위 : mm < TOP View > < SIDE View > < BOTTOM View > 제품사진 (DTPML-485-81) < TOP View > < SIDE View > < BOTTOM View >

Page 5 of 14 MODBUS 485-RTU Protocol 1. 통신규격 통신버스 : RS485 Multi-Drop, Half duplex 통신속도 : 19200 bps DATA : 8 bit Parity : NONE STOP : 1 bit Handshake : NONE 2. 송수신시퀀스 T1 : 캐릭터간의지연시간 T2 : 요구텔레그램과응답텔레그램간의지연시간 T3 : 한 Frame(Request->Response) 완료후다음 Frame 시작간의지연시간 Baud rate T1 min T1 Max T2 min T2 Max T3 가변가능여부불가불가불가불가 19200 1ms 2ms 3ms 11ms ( 최소 ) 20ms 이상 주의 : T2의경우 ID Write하는 Function 0x06 의명령에서는응답이더늦을수있습니다. 내부적으로 ID값을 Flash에저장을하는시간이필요합니다.

Page 6 of 14 3. Request/ Response (Function 0x03) - 온도값 Read 예제 Request ( Master DTPML-485) Response ( DTPML-485 Master ) Field Name Hex DEC Field Name Hex DEC 1 ID 0x01~0xc8 1~200 1 ID 0x01~0xc8 1~200 Function 0x03 3 Function 0x03 3 Starting Address Hi 0x04 Byte Count 0x04 4 1200 Starting Address Lo 0xB0 Data Value 1 Hi 대상온도 No. of Data Hi 0x00 Data Value 1 Lo 2 No. of Data Lo 0x02 Data Value 2 Hi 센서온도 Data Value 2 Lo 8 Byte Request 9 Byte Response 1 ID는출고시 0x01로설정돼있습니다. ID를바꾸려면아래 4번 ID Write 를참고하세요. ID값은 1~200 까지가능합니다. 4. Request/ Response (Function 0x06) - ID Write 예제 Request ( Master DTPML-485) Response ( DTPML-485 Master ) Field Name Hex DEC Field Name Hex DEC 2 ID 0xFF 255 ID 0xFF 255 Function 0x06 6 Function 0x06 6 Register Address Hi 0x03 Register Address Hi 0x03 1000 Register Address Lo 0xe8 Register Address Lo 0xe8 Register Value Hi 0x00 Register Value Hi 0x00 3 ID Register Value Lo 3 ID Register Value Lo ID 1000 ID 8 Byte Request 8 Byte Response 2 번 ID 위치에는 0xff 값을써야 ID write 를인식합니다. 3 ID 에는쓰고자하는 ID 를넣으면됩니다.

Page 7 of 14 5. 온도계산법예제1) 영상온도 응답한데이터 HEX DEC Data Value 1 Hi Data Value 1 Lo Data Value 2 Hi Data Value 2 Lo 0x016D 365 0x00FA 250 대상온도 : 0x016D = 365 --> 36.5도센서온도 : 0x00FA = 250 --> 25.0도예제2) 영하온도응답한데이터 HEX DEC Data Value 1 Hi Data Value 1 Lo Data Value 2 Hi Data Value 2 Lo 0xFFF1 0xFF9C 대상온도 : 0xFFF1 -> (2의보수연산) -> 0x000F = 15 즉, -1.5도센서온도 : 0xFF9C -> (2의보수연산) -> 0x0064 = 100 즉, -10.0도 6. 방사율 6-1. 방사율쓰기 (Function 0x06) Request ( Master DTPML-485) Response ( DTPML-485 Master ) Field Name Hex DEC Field Name Hex DEC ID 0x01~0xc8 1~200 ID 0x01~0xc8 1~200 Function 0x06 6 Function 0x06 6 Register Address Hi 0x03 Register Address Hi 0x03 800 Register Address Lo 0x20 Register Address Lo 0x20 Register Value Hi 0x00 Register Value Hi 0x00 10~100 Register Value Lo 4방사율 Register Value Lo 방사율 800 10~100 8 Byte Request 8 Byte Response 4 " 방사율 " 은 10~100 까지변경이가능합니다.

Page 8 of 14 단, 방사율에 100을곱한값을전송하여야합니다. 전송할데이터 HEX DEC ( 방사율 *100) 방사율 0x0A 10 0.1 0x32 50 0.5 0x5F 95 0.95 0x63 99 0.99 전송할데이터 위의예처럼방사율 0.95 로변경할경우 4" 방사율 " 에정수값 95 를입력하면됩니다. 6-2. 방사율읽기 (Function 0x04) Request ( Master DTPML-485) Response ( DTPML-485 Master ) Field Name Hex DEC Field Name Hex DEC ID 0x01~0xc8 1~200 ID 0x01~0xc8 1~200 Function 0x04 4 Function 0x04 4 Starting Address Hi 0x03 800 Byte Count 0x02 2 Starting Address Lo 0x20 방사율 Hi 0x00 0 Quantity of Input Reg. Hi 0x00 1 방사율 Lo 0x0A~0x64 10~100 Quantity of Input Reg. Lo 0x01 8 Byte Request 7 Byte Response

Page 9 of 14 7. 레이저 ON (Function 0x06) Request ( Master DTPML-485) Response ( DTPML-485 Master ) Field Name Hex DEC Field Name Hex DEC ID 0x01~0xc8 1~200 ID 0x01~0xc8 1~200 Function 0x06 6 Function 0x06 6 Register Address Hi 0x04 Register Address Hi 0x04 1100 Register Address Lo 0x4C Register Address Lo 0x4C Register Value Hi 0x00 Register Value Hi 0x00 1 Register Value Lo 0x01 Register Value Lo 0x01 1100 1 8 Byte Request 8 Byte Response 레이저를눈으로바라보지마십시오. 레이저는명령후약 15~20 초간동작합니다. 레이저가꺼지기전에반복명령을주면마지막 Command 을기준으로 15~20 초간동작합니다. 레이저포인터는 1~2m 기준중심에서 10cm 이내로포인트오차가있을수있습니다. 가리키는방향을참고하시기바랍니다. Optical field of view (FOV) The optical chart below indicates the nominal target spot diameter at any given distance from the sensing head and assumes 50% energy. < DTPML-485-81 > < DTPML-485-151 >

Page 10 of 14 DISTANCE AND SPOT SIZE Spot Size 는아래그림에서와같이측정하고자하는대상의면적보다반드시작아야합니다. Pin Assignment number Name Description Type 1 PE Protective earth 2 D+ 485 D+ 3 D- 485 D- 4 GND Ground 5 5V Supply Voltage Connector : (Header : molex 5267-05), ( Female : molex 5264-05 )

Page 11 of 14 종단저항 RS485 의통신에있어서지연등에의한왜곡과감쇠방지를목적으로선로의임피던스매칭을위해저항을삽입합니다. 이를종단저항이라합니다. DTPML-485 모듈에는 120옴의기본종단저항이적용돼있으며간단히스위치의조작을통해종단저항적용을 ON/OFF 시킬수있습니다. < 종단저항미적용 > < 종단저항적용 > 주의사항 1. 종단저항은항상 120옴은아닙니다. 상황에따라저항을바꿔줘야할상황이있을수있습니다. 저항을바꿀때에는위그림에서종단저항 120옴부분의저항을바꿔주시면됩니다. 2. 종단저항교체시 90옴이하의저항은사용하지마십시오. 3. 통신선로상에서 2개이상의종단저항을 ON 하면안됩니다. 4. 제품출고시기본종단저항스위치가 OFF 상태로출고됩니다.

Page 12 of 14 Ordering Guide DTPML - - Laser Protocol DS ratio 측정온도범위 L Laser 장착 485 Modbus 485 RTU 81 8:1-20 ~ 200 SPI SPI 151 15:1-20 ~ 270 예 ) DTPML-485-151 - 레이저장착, 15:1 DS ratio, 485 통신모델을의미합니다. 테스트보드 ( 별도구매 ) - CT-Testboard-Plus 손쉽게측정하여온도값을다른 device(mcu, PC, embedded 등 ) 로전송 (RS-232) 할수있습니다. < CT-Testboard-Plus > 테스트보드에서레이저켜는법 : 온도측정중에 "ID" 버튼을누르면레이저가켜집니다. Additional Information manufacturer : Diwell Electronics Co., Ltd. <( 주 ) 디웰전자 > Homepage : www.diwell.com shopping mall : www.diwellshop.com Phone : +82-70-8235-0820 Fax : +82-31-429-0821 Technical support : expoeb2@diwell.com, dsjeong@diwell.com

Page 13 of 14 Appendix - A ( 방사율표 ) 방사율이란물체가외부적외선에너지를흡수, 투과및반사하는비율을말하는데, 이론적으로외부에너지를흡수만하고반사하지않는물체를흑체라하여이때의방사율은 "1" 입니다. 하지만, 일반적으로물체의표면상태 ( 광택, 거침, 산화여부등 ) 에따라흡수, 반사하는에너지량이변합니다. 재질에따른방사율값은하단의 " 방사율표 " 를참고하여변경하면됩니다. 단, " 방사율표 " 의값은절대적인값이아니며표면상태와그외복합적인환경요인에따라오차가있을수있으니, 이점참고하십시오. 대상 방사율 대상 방사율 대상 방사율 산화아연 0.1 에나멜 0.9 구리 ( 연마된 ) 0.5 아연도금철 0.3 페인트 0.95 구리 ( 산화된 ) 0.8 주석도금철 0.1 라카 0.9 니켈 ( 순수 ) 0.1 금 ( 연마된 ) 0.1 고무 (smooth) 0.9 니켈 ( 산화된 ) 0.4~0.5 은 ( 연마된 ) 0.1 고무 (Rough) 0.98 니켈크롬 0.7 크롬 ( 연마된 ) 0.1 플라스틱 0.8~0.95 니켈크롬 ( 산화된 ) 0.95 붉은벽돌 0.75~0.9 플라스틱필름 0.5~0.95 직물 0.9 흙 0.92~0.96 주철 ( 연마 ) 0.2 피부 0.98 석면 0.95 Steel 0.6 가죽 0.75~0.8 콘크리트 0.7 산화 Steel 0.9 얼음 0.96~0.98 대리석 0.9 목재 0.8~0.9 모래 0.9 모르타르 0.89~0.91 스테인레스 ( 연마된 ) 0.1 아스팔트 0.9~0.98 석고 0.85 스테인레스 ( 기타 ) 0.2~0.6 유리 0.8~0.9 시멘트 0.96 알루미늄 ( 연마된 ) 0.1 물 0.8~0.9 규토 ( 정제된 ) 0.4 알루미늄 ( 합금 ) 0.1~0.25 종이 0.9 세라믹 0.90~0.94 황동 ( 연마된 ) 0.1 실리콘 0.7 석영 0.9 황동 ( 거친 ) 0.2 주철 ( 부식된 ) 0.95 석탄 0.75 황동 ( 산화된 ) 0.6 Mild Steel 0.3~0.5 Fe( 부식된 ) 0.7~0.85 측정하고자하는대상의재질이코팅이돼있거나반짝이는재질이라면방사율을수정적용해도온도변화가적을수있습니다. 이때에는측정물체표면에무광의락카스프레이를칠하면됩니다.

Page 14 of 14 DTPML-485 Revision History Version Date Description 1.0 2015-10-20 First version is released. 1.1 2015-12-22 부품변경에따른소비전류변경, PCB 종단저항스위치적용