02 Reihe bis 750 bar GB-9.03

Similar documents
WOMA Pumps - Z Line

ๆญฏcoolingtower๊ฐœ์š”_1_.PDF

<BACEBDBAC5CD20BAEAB7CEBCC52D A2DC3D6C1BE2D312D E6169>

(specifications) 3 ~ 10 (introduction) 11 (storage bin) 11 (legs) 11 (important operating requirements) 11 (location selection) 12 (storage bin) 12 (i

E010 CYLINDER BLOCK GROUP (0 01) 76

#KM-1751/1791..

(Table of Contents) 2 (Specifications) 3 ~ 10 (Introduction) 11 (Storage Bins) 11 (Legs) 11 (Important Operating Requirements) 11 (Location Selection)

Microsoft PowerPoint - Powertrain_Actuator

Parts List

#KM-350AB..

ๆญฏ๊ตญ๋ฌธ-Heatran์†Œ๊ฐœ์ž๋ฃŒ1111.PDF

ๆญฏTrap๊ด€๋ จ.PDF

CFP ์ œ์ž‘(0113)

#KM-250ลก

์†Œ๊ฐœ.PDF

0604ํฌ๋ฆฌ์• ๋“œ-์ค‘์•™์นดํ”„๋ง์ˆ˜์ • :46 AM ํŽ˜์ด์ง€7 GEAR COUPLING ํŠน์ง• / Distinctive 1. ์ค‘์•™(Jac) ๊ธฐ์•„์นดํ”„๋ง์€ ์ „๋‹ฌ๋งˆ๋ ฅ์— ๋น„ํ•˜์—ฌ ์†Œํ˜• ๊ฒฝ๋Ÿ‰์ด๋ฉฐ ๊ณ ์† ํšŒ์ „์‹œ์—๋„ ์†Œ์Œ ๋ฐ ์ง„๋™์ด ๊ฑฐ์˜ ์—†๊ณ , ๊ธด ์ˆ˜๋ช…์„ ์œ ์ง€ํ•˜์—ฌ ์ „๋‹ฌ ๋™๋ ฅ์˜

3์žฅ ION M74 ์ž๋™๋ณ€์†๊ธฐ.ppt

# KM

GEAR KOREA

ๆญฏRCM

Z DB 6 -X V * Sandwich plate = Z Further details in clear text With pressure valve cartridges = No code = Without locating pin hole (only applies to v

GD-SERISE / GS-SERISE DESCRIPTION GD / GS series pneumatic actuator are designed & developed with new concept for the next generation. GD / GS series


KM-380BL,BLB(100908)

#SPS/B-BH6000ลก

#KM-1750/1790..

< C6AFC1FD28B1C7C7F5C1DF292E687770>

*KM-380BL,BLB724.

<BAB0C3A5BABBB9AE2E687770>

Ball float steam trap ๊ธฐ๊ณ„์‹์ŠคํŒ€ํŠธ๋ ™ ( ์ฆ๊ธฐ์™€๋“œ๋ ˆ์ธ์˜๋น„์ค‘์ฐจ์ด์šฉ ) ๋ณผํ”Œ๋กœํŠธ์‹์ŠคํŒ€ํŠธ๋ ™ CONA SC ANSI / SC Plus ANSI Ball float steam trap CONA SC Ball float steam trap with capsule

Berechenbar mehr Leistung fur thermoplastische Kunststoffverschraubungen

๊ธฐ๋Šฅ.PDF

12ํ•˜์ด๋ธŒ๋ฆฌ๋“œ๋ธŒ๋กœ์…”-๊ตญ๋ฌธ

2.2, Wm -2 K -1 Wm -2 K -2 m 2 () m 2 m 2 ( ) m -1 s, Wm -2 K -1 Wsm -3 K -1, Wm -2 K -1 Wm -2 K -2 Jm -3 K -1 Wm -2 K -1 Jm -2 K -1 sm -1 Jkg -1 K -1

1. Features IR-Compact non-contact infrared thermometer measures the infrared wavelength emitted from the target spot and converts it to standard curr

ยณยปรรถร€ร›ยพรท-~89ลก

13์žฅ_

PL E-Euro-V01.pmd

#KM

ITVX-A-C1

ํ•œ๊ตญ์ฝ˜๋ฒ ์–ด-AP8p

#SPS/C-5050.B.

#KM857/867..

COLUMN, BED, SADDLE The column is of a rugged box-type construction and its ground slide ways are wide to support and guide securely the spindle head.

Elix 3 Elix 5 Elix 10 RiOs 3 RiOs 5 RiOs 8 RiOs 16!.. MILLIPORE

์œ ์„ฑ๊ฐ์†๊ธฐ_K_170404

GLHPS-D

๋‚˜์‚ฌ์‹๋ณผ๋ฐธ๋ธŒ.indd

2013<C724><B9AC><ACBD><C601><C2E4><CC9C><C0AC><B840><C9D1>(<C6F9><C6A9>).pdf

๋Œ€ํ˜•๋””์ ค๊ธฐ๊ด€์˜ Cooled-EGR์ œ์–ด ์‹œ์Šคํ…œ ๊ฐœ๋ฐœ์— ๊ด€ํ•œ ์‹คํ—˜์  ์—ฐ๊ตฌ

#KM-235(110222)

Electropure EDI OEM Presentation

ETC Electrolytic Technologies Corporation Electrolytic Technologies Corporation (ETC) (High Strength Sodium Hypochlorite). ETC.,. ETC,,. - (Cl2) (NaOH

ๆญฏ์ „์šฉ]

X-VA-MT3809G-MT3810G-kor

PowerPoint ํ”„๋ ˆ์  ํ…Œ์ด์…˜

๋ชฉ์ฐจ ์›ํ•˜์‹œ๋Š” ํ™”๋ฌผ ํฌ์žฅ ์•ˆ๋‚ด๋ฅผ ํด๋ฆญํ•˜์‹ญ์‹œ์˜ค. ์ผ๋ฐ˜ ํ™”๋ฌผ ํฌ์žฅ ์•ˆ๋‚ด 3 ์ปดํ“จํ„ฐ ๊ธฐ๊ธฐ ํ™”๋ฌผ ํฌ์žฅ 9 ์ž๋™์ฐจ ๋ฐ ๊ธฐ๊ณ„ ๋ถ€ํ’ˆ ํฌ์žฅ ์•ˆ๋‚ด ๋ฐ ์„ค๊ณ„ 15 ๋ฐฐํ„ฐ๋ฆฌ ๋ฐฐ์†ก๋ฌผ ํฌ์žฅ 23

REVERSIBLE MOTOR ํ‘œ์ง€.gul

๋ชฉ์ฐจ

WIDIN - Toolholding Catalogue.pdf

๋„ํ๋ฉ˜ํŠธ3

RC /07.12 RC / /6 2 3 / CA-08A-2N 2 CA-10A-2N 2 CA-12A-2N 2 CA-16A-2N 2 CA-20A-2N CA-08A-3N 4 CA-10A-3N 4 CA-12A-3N

#KM-340BL

2013 Energy Info. Korea

์ตœ์ข…๋™์•„์ˆ˜์ •๋„ํ01

์ง€๊ธˆ๊นŒ์ง€ ๊ณ ์šฉ๋…ธ๋™๋ถ€๋Š” ๊ทผ๋กœ๊ธฐ์ค€๋ฒ•์ด ๊ทผ๋กœ์‹œ๊ฐ„๊ณผ ์—ฐ์žฅ๊ทผ๋กœ, ํœด์ผ๊ทผ๋กœ๋ฅผ ๊ตฌ๋ณ„ํ•˜๊ณ  ์žˆ๊ณ , ๋”ฐ๋ผ์„œ ์—ฐ์žฅ๊ทผ๋กœ์— ํœด์ผ๊ทผ๋กœ๋Š” ํฌํ•จ๋˜์ง€ ์•Š๋Š”๋‹ค๋Š” ์‹์œผ๋กœ ํ–‰ ์ •ํ•ด์„์„ ํ•ด์™”๋‹ค. ์ด์— ๋”ฐ๋ฅด๋ฉด ํ† ์š”์ผ๊ณผ ์ผ์š”์ผ ํœด์ผ๊ทผ๋กœ๋Š” 12์‹œ๊ฐ„ ์ด์ƒ์˜ ์—ฐ ์žฅ๊ทผ๋กœ๋ฅผ ๊ธˆ์ง€ํ•˜๋Š” ์ œํ•œ ๊ทœ์ •์—์„œ ์ œ์™ธ๋˜๊ณ , ๋”ฐ๋ผ์„œ ์—ฐ

?????????????????2009-????????

INDUCTION MOTOR ํ‘œ์ง€.gul

์—ฐ๊ตฌ์ง„ ์—ฐ๊ตฌ์ฑ…์ž„ ์—ฐ ๊ตฌ ์› ๊น€์šด์ˆ˜ / ๊ตํ†ต๋ฌผ๋ฅ˜์—ฐ๊ตฌ์‹ค ์—ฐ๊ตฌ์œ„์› ์ด๋ช…ํ™” / ๊ตํ†ต๋ฌผ๋ฅ˜์—ฐ๊ตฌ์‹ค ์ดˆ๋น™์—ฐ๊ตฌ์›

84-01~11

์ƒ๊ธฐ ์ด๋ฏธ์ง€๋Š” ๊ตญ๋‚ด ์‚ฌ์–‘๊ณผ ๋‹ค์†Œ ์ฐจ์ด๊ฐ€ ์žˆ์„ ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

PowerPoint ํ”„๋ ˆ์  ํ…Œ์ด์…˜

INSIDabcdef_:MS_0001MS_0001 5kW - ใ…‡ * 2 ( 14) 6, % % ( 7, 15.07) -, ใ…‡ * (bottoming power unit),, kw MW * - /, GE ใ…‡ - ใ…‡ : - 5kW (TRL: [ ์‹œ์ž‘

ecorp-ํ”„๋กœ์ ํŠธ์ œ์•ˆ์„œ์ž‘์„ฑ์‹ค๋ฌด(์–‘์‹3)

๋ ˆ์ด์•„์›ƒ 1

B-3 B-4 HDV B-8 B-37 B-39 3S1A B-40 3S2A B-42 3S3A B-44 3S4A B-45 B-11 B-15 S1A B-16 K2A B-20 K3A B-24 S3A B-27 S4A B-30 S5A B-33 HPV5-6, HPV5-8 B-78

D40-T00A CLUTCH GROUP D40-T0A CLUTCH LEVER GROUP DK45-T0A CLUTCH HOUSING GROUP.....

ร‡รยผรบยดรซรˆยธยฟรยผยบ

2012ยณรข8ยฟรนรˆยฃห™รˆยธลก

untitled

ํšจ์„ฑํŽŒํ”„ํŽธ๋žŒ

ๆญฏMW-1000AP_Manual_Kor_HJS.PDF

๋ชฉ์ฐจ Twin Seal Valve ์„ค์น˜ ์ž‘๋™ 2 00, 00, 00 ์‹œ๋ฆฌ์ฆˆ ์ผ์ฒดํ˜• ๋ถ€์‹ฑ/๊ณ ์ • ๋ง ๋งˆ๊ฐœ ์ผ์ฒดํ˜• ๋ถ€์‹ฑ/๋ณผํŠธํ˜• ๋งˆ๊ฐœ ๋ถ€์‹ฑ/๋‹จ์ผ ๋งˆ๊ฐœ ๋ถ€์‹ฑ/์ด์ค‘ ๋งˆ๊ฐœ ๋ฒ ์–ด๋ง/์ด์ค‘ ์ฐจ์•• 5 ๋ฒ ์–ด๋ง/๋‚ด๋ถ€ ๋ฐ ์™ธ๋ถ€ ๊ณ ์ • ๋ฒ ์–ด๋ง/๋‘ ๋งˆ๊ฐœ๋กœ ๋‚ด๋ถ€ ๊ณ ์ • 00 ์‹œ๋ฆฌ์ฆˆ 7 ์ž‘๋™๊ธฐ ๋ชจ๋ธ 75

แ„‹แ…ฑแ†ฏแ„…แ…ฉ แ„‹แ…ฉแ„‡แ…ขแ„‰แ…ฎแ„‘แ…ขแ„แ…ตแ„Œแ…ตแ„‰แ…ตแ„‰แ…ณแ„แ…ฆแ†ท indd

Pilot Operated Regulator 1098-EGR ์šฉ๋„ ๋„์‹œ๊ฐ€์Šค์ง€๊ตฌ์ •์••๊ธฐ (City Gate Station, Main Station) ๋„์‹œ๊ฐ€์Šค์ง€์—ญ์ •์••๊ธฐ (District Station) ์ƒ ๊ณต์—…์šฉ๋Œ€์œ ๋Ÿ‰์ „์šฉ์ •์••๊ธฐ ( ๋นŒ๋”ฉ, ๊ณต์žฅ, ๋ณ‘์›, ํ•™๊ต ) ์‚ฐ์—…์šฉ๋Œ€์œ ๋Ÿ‰๊ธฐ

example code are examined in this stage The low pressure pressurizer reactor trip module of the Plant Protection System was programmed as subject for

1 grating steel bar grating Hot Dip Galvanized Steel Bar Grating stage flooring stair treads 2 heat resisting casting parts of refuse in

๋Œ€๊ฒฝํ…Œํฌ์ข…ํ•ฉ์นดํƒˆ๋กœ๊ทธ

#KM560

์Šฌ๋ผ์ด๋“œ 1

PowerPoint ํ”„๋ ˆ์  ํ…Œ์ด์…˜

4์ž„๊ธˆ์—ฐ๊ตฌ๊ฒจ์šธ-์ง€์ƒํ† ๋ก 

(2006)-01

00.1

2015_METRIC_CAT.indd

์•ˆ์ „-09์žฌ์ถœ๋ ฅ

D101351X0KR_May17

ํšŒ์‚ฌ์†Œ๊ฐœ์„œ

<4D F736F F F696E74202D20C0CEC5CDB1D7B7A1C7C120C8B8BBE7BCD2B0B320666F F E BC0D0B1E220C0FCBFEB5D>

CD-6208_SM(new)

Transcription:

Water as a tool High-Pressure Plunger Pumps 02-Line (up to 750 bar) 252 702 1002 1502 1852 2502

Technical Data High-Pressure Plunger Pump Type 252 / 702 approx. 1.8 l approx. 50 kg net 45 mm/1.77 inch Inlet pressure required*: 2 bar/30 psi 7.5 kn * Depends on operating mode, crank shaft speed and water temperature 210 100 35 220 260 M16-35 deep 36 18 Key per DIN 6885 Page 1 136 220 272 80 40 365 300 30 160 15 ø30n6 Discharge on both sides G 3/4 on both sides G 1 1/2 Discharge on both sides G 3/4 310 Performance Chart Pump Type 252 Plungerdiameter Crank shaft Required drive Nominal flow rate Maximum permissible (mm) (Rpm) (kw) USG pm IMPG pm (l/min) operating pressure (psi/bar) P22 1,000 18 13.5 11.2 51 750 13 10.0 8.4 38 2,0/ P24 1,000 18 16.1 13.4 61 750 14 11.9 9.9 45 2,320/160 P26 1,000 18 18.8 15.6 71 750 13 14.0 11.7 53 1,958/135 P30 1,000 18 25.1 20.9 95 750 13 18.8 15.6 71 1,450/100 P35 1,000 18 34.1 28.4 129 750 14 25.6 21.3 97 1,088/ 75 connection for oil cooling IG3/4 182 345 407,5 mounting space 140 250 245 284 approx. 3.2 l approx. 150 kg net 44.5 mm/1.75 inch Inlet pressure required*: 2 bar/3 bar 30 psi/43,5 psi (1000 Rpm) 21 kn 12,5 241 suction 529 109 16,5 284,5 oil sight glass 52 25 213 key12x70 per DIN 6885 page1 ø 40 k6 ø19 420 384 108 62,5 25 suction IG 3/4 ø 19 384 420 discharge M30x1,5 40,5 184,5 300 426 mounting space * Depends on operating mode, crank shaft speed and water temperature 667 Performance Chart Pump Type 702 Plungerdiameter Crank shaft Required drive Nominal flow rate Maximum permissible (mm) (Rpm) (kw) USG pm IMPG pm (l/min) operating pressure (psi/bar) P20 1000 47 10.30 8.58 39 750 35 7.66 6.38 29 9,425/650 P24 1000 48 15.32 12.76 58 750 37 11.36 9.46 43 6,500/450 P26 1000 50 17.96 14.96 68 750 37 13.47 11.22 51 5,800/400 P30 1000 50 24.04 20.02 91 750 37 17.96 14.96 68 4,400/300 P35 1000 51 33.02 27.50 125 750 38 24.83 20.68 94 3,/220 P40 1000 51 43.59 36.30 165 750 38 32.49 27.06 123 2,500/170 P45 1000 52 55.21 45.97 209 750 38 41.48 34.54 157 1,958/135

High-Pressure Plunger Pump Type 1002 / 1502 Inlet pressure required: approx. 6 l approx. 254 kg net 73 mm/2.88 inch 2 bar/30 psi 29.4 kn 295 239 435 455 suction G1 1/2 40,5 239 864 295 484 315 299 81,5 230,5 330 82 82 suction G11/2 Connection for Oil cooling G 1/2 301 key per DIN 6885 Bl.1 ø40k6 41 discharge M30x1,5 167 134 226 284 365 98 40 ø19 170 175 45 345 50 ø35k6 key per DIN 6885 Bl.1 Performance Chart Pump Type 1002 Plunger- Gear Ratio Crank Required Nominal flow rate Maximum permissible (mm) 1,500 1,800 (Rpm) (kw) pm pm (l/min) (psi/bar) 3.63 495 56 10.6 8.8 40 P 22 3.00 500 56 10.6 8.8 40 10,875/750 3.63 413 46 8.7 7.3 33 3.63 495 56 14.5 12.1 55 P 26 3.00 500 57 14.8 12.3 56 7,975/550 3.63 413 47 12.2 10.1 46 3.63 495 58 27.5 22.9 104 P 35 3.00 500 58 27.7 23.1 105 4,350/300 3.63 413 48 22.7 18.9 86 3.63 495 58 35.9 29.9 136 P 40 3.00 500 58 36.2 30.1 137 3,335/230 3.63 413 48 29.9 24.9 113 3.63 495 57 45.4 37.8 172 P 45 3.00 500 58 46.0 38.3 174 2,610/180 3.63 413 48 37.8 31.5 143 approx. 9 l approx. 319 kg net 95 mm/3.74 inch Inlet pressure required*: from P 40: 2 5 bar/30 75 psi 40 kn * Depends on plunger diameter 268 304 572 255 351 Performance Chart Pump Type 1502 211 133 250 630 41 346 41 83 675 975 Oil sight glass Connection for Oil cooling G 1/2 Key 14x72 per DIN 6885 Page 1 495 Ø50k6 100 Ø19 240 Discharge Plunger- Gear Ratio Crank Required Nominal flow rate Maximum permissible (mm) 1,500 1,800 2,100 (Rpm) (kw) pm pm (l/min) (psi/bar) 4.57 459 91 17.7 14.7 67 3.69 488 98 19.0 15.8 72 P 26 79 101 15.3 19.5 12.8 16.3 58 74 10,875/750 3.69 407 82 15.9 13.2 60 4.57 328 66 12.7 10.6 48 4.57 459 93 23.8 19.8 3.69 488 99 25.4 21.1 96 P 30 79 102 20.3 26.2 16.9 21.8 77 99 8,193/565 3.69 407 82 21.1 17.6 80 4.57 328 66 16.9 14.1 64 4.57 459 94 33.0 27.5 125 3.69 488 100 35.1 29.3 133 P 35 81 104 28.3 36.5 23.5 30.4 107 138 6,018/415 3.69 407 84 29.3 24.4 111 4.57 328 67 23.5 19.6 89 4.57 459 96 43.3 36.1 164 3.69 488 101 46.0 38.3 174 P 40 82 105 37.0 47.8 30.8 39.8 140 181 4,640/320 3.69 407 85 38.3 31.9 145 4.57 328 68 30.9 25.7 117 4.57 459 94 54.7 45.5 207 3.69 488 101 58.4 48.6 221 P 45 81 47.0 39.2 178 104 60.5 50.4 229 3,625/250 3.69 407 84 48.6 40.5 184 4.57 328 68 39.1 32.6 148 180 185 75 45

High-Pressure Plunger Pump Type 1852 211 133 630 255 351 240 250 268 304 572 41 346 41 83 675 975 Oil sight glass Connection for Oil cooling G 1/2 approx. 9 l approx. 328 kg net 95 mm/3.74 inch Inlet pressure required*: from P 40: 2 5bar/30 75psi 50 kn * Depends on plunger diameter Key 14x72 per DIN 6885 Page 1 495 Ø50k6 100 Ø19 Discharge 75 185 180 45 Performance Chart Pump Type 1852 Plunger- Gear Ratio Crank Required Nominal flow rate Maximum permissible (mm) 1,500 1,800 2,100 (Rpm) (kw) pm pm (l/min) (psi/bar) 4.57 460 103 19.8 16.5 75 3.69 488 109 21.1 17.6 80 P 28 4.57 394 89 17.4 14.5 66 115 21.9 18.3 83 10,875/750 3.69 407 92 17.7 14.7 67 4.57 328 74 14.3 11.9 54 4.57 460 113 23.8 19.8 3.69 488 121 25.4 21.1 96 P 30 4.57 394 98 20.3 16.9 77 126 26.2 21.8 99 10,150/700 3.69 407 100 21.1 17.6 80 4.57 328 84 16.9 14.1 64 4.57 460 117 33.0 27.5 125 3.69 488 124 35.1 29.3 133 P 35 4.57 394 100 28.3 23.5 107 129 36.5 30.4 138 7,540/520 3.69 407 104 29.3 24.4 111 4.57 328 84 23.5 19.6 89 4.57 460 120 43.3 36.1 164 3.69 488 127 46.0 38.3 174 P 40 4.57 394 102 37.0 30.8 140 133 47.8 39.8 181 5,800/400 3.69 407 105 38.3 31.9 145 4.57 328 85 30.9 25.7 117 4.57 460 121 54.7 45.5 207 3.69 488 130 58.4 48.6 221 P 45 4.57 394 105 47.0 39.2 178 135 60.5 50.4 229 4,640/320 3.69 407 107 48.6 40.5 184 4.57 328 87 39.1 32.6 148

Technical Data High-Pressure Plunger Pump Type 2502 211 133 575 Thread M as per DIN 13/ISO 261 Thread G as per DIN ISO 228/1 approx. 8 l approx. 350 kg net 95 mm/3.74 Inlet pressure required*: from P 40: 2 bar/30 psi 70 kn * Depends on operating mode, crank shaft speed and water temperature 318 304 622 255 358 Connection for Oil cooling G 1/2 495 41 346 41 83 621 919 Oil sight glass Ø50 k6 100 Key 14x72 per DIN 6885 Page 1 Ø19 180 75 240 185 180 45 Discharge Performance Chart Pump Type 2502 Plunger- Gear ratio Crank Required Nominal flow rate Maximum permissible (mm) 1,500 1,800 2,100 (Rpm) (kw) pm pm (l/min) (psi/bar) 4.52 464 120 24.0 20.0 91 3.57 504 130 26.2 21.8 99 P30 4.52 398 103 20.6 17.2 78 3.04 493 127 25.4 21.1 96 10,875/750 3.57 420 108 21.7 18.0 82 4.52 331 85 17.2 14.3 65 4.52 464 143 32.8 27.3 124 3.57 504 155 35.4 29.5 134 P35 4.52 398 122 28.0 23.3 106 3.04 493 152 34.9 29.0 132 9,425/650 3.57 420 129 29.6 24.6 112 4.52 331 102 23.2 19.4 88 4.52 464 146 43.9 36.5 166 3.57 504 158 47.6 39.6 180 P40 4.52 398 125 37.5 31.2 142 3.04 493 155 46.5 38.7 176 7,250/500 3.57 420 132 39.6 33.0 150 4.52 331 104 31.2 26.0 118 4.52 464 149 55.5 46.2 210 3.57 504 162 60.2 50.2 228 P45 4.52 398 128 47.6 39.6 180 3.04 493 159 58.9 49.1 223 5,800/400 3.57 420 135 50.2 41.8 1 4.52 331 106 39.6 33.0 150

Technical Advantages Pump Gear Proven pump gear with forced oil lubrication and variable gear ratios Pump Head Easy-to-service pump head in block design made of treated forged steel Flange-mounted suction and discharge channel Valve design for high efficiency and easy servicing Maintenance-free plunger seal with lamellar packing Plungers made of ceramics (Types 252 to 2502) Long service live Additional Equipment Pressure regulating valve with pneumatic control Pneumatically controlled 2/2-way pressure relief valve Pneumatically controlled 3/2-way valve Pneumatically controlled high-pressure valves for parallel operation of several users Options Pump head, cylinders and valves made from special materials for aggressive media, e.g. seawater High-pressure waterjet system with electrically driven highpressure plunger pump Type 752 WOMA GmbH Werthauser Str. 77 79 D-47226 Duisburg P.O. Box 14 18 20 D-47208 Duisburg Phone +49 2065 304-0 Fax +49 2065 304- Internet: www.woma.de E-mail: info@woma.de Delivery Programme High-pressure plunger pumps High-pressure water jet systems High-pressure water tools and accessories High-pressure cleaning system with electric motor and high-pressure plunger pump Type 552 High-pressure cleaning system in explosion proofness design with electric drive and high-pressure plunger pump Type 1502 Fields of Application Agriculture Automotive and aviation industry Beverage industry Cement industry Chemical industry Construction and concrete industry Engineering industry Food industry Glass, porcelaine, ceramic industry Iron, steel and metal industry Mining Municipal services Offshore industry Power industry Public transport Pulp and paper industry Ship building Wood working industry HP-P-02-Line 1/09-E Subject to technical modification