1 The Best Reliable Partner for High Availability * 2008 상반기효과적인시스템관리를위한기술세미나 - COEX, Seoul, Korea P-Sysplex performance Updates 고태호과장 (koth@kr.ibm.com) Advisory IT Specialist MTS, IBM Global Technology Services Korea April 8, IBM Corporation
2 Agenda 1. Performance on Sysplex components 1) Coupling Facility CF Service time and Delays System-Managed Duplexing CF Structure performance CFCC Level 15 Updates 2) XCF 2. Performance on Sysplex configurations 2/ 51
3 1. Performance on Sysplex components 1) Coupling Facility CF Service time and Delays System-Managed Duplexing CF Structure performance CFCC Level 15 Updates 2) XCF 2. Performance on Sysplex configurations 3/ 51
4 성능측면에서의 Sysplex 구성요소 아키텍쳐 Structures (Lock, List, Cache) Commands Coupling Technology CF 하드웨어 Coupling Facility CPs (Shared,Dedicated) Links High speed links Sender 와 Receiver link 소프트웨어 CFCC z/os와서브시스템 XCF, XES 4/ 51
5 Tuner s View of the Coupling Facility 3가지형태의 structure LIST (and Serialized List) Lock Cache Each exploiter has a different implementation Beware of general concepts like good or bad Use the performance data provided by the exploiter Make a general review of workloads and rates Are the CF accesses equivalent? Are the service times equivalent? Are there any indicators of delay of type links or subchannels? What are the CPU indicators? 5/ 51
6 Elements of CF model Link/Path : CEC와 CF를연결하는channel Link buffers : link내에존재하는 buffer Compatibility mode : link당 2개의 buffer Peer mode : link당 7개의 buffer Software subchannel z/os에서 CF request의전송시사용되는 buffer Link buffer와 1:1 관계 6/ 51
7 CF Request type Synchronous immediate Lock type access Delay time과 Service time이 CPU busy time에포함됨 Synchronous non-immediate Cache type access (transfers of data < 4k) Service time만 CPU busy time에포함됨 (if not converted) Async request로변환될수있음 Asynchronous Cache type access (transfers of data > 4k) 주로 IOP/SAP에의해처리됨 Subchannel busy일경우에는requeued, path busy일경우에는redriven 7/ 51
8 CF Request flow Sync/Async Sync Request APPL SQL DB2 IRLM XES H/W CF Processor Sysplex cost CPU busy Active Loop CFCC CF s CPU cost Async Request OS s CPU time APPL SQL DB2 IRLM XES H/W CF Processor CFCC OS s CPU time Elapse time In SQL ops. CPU Release HSA CF s CPU cost 8/ 51
9 CF 측정요소 COUPLING FACILITY NAME = CF SUBCHANNEL ACTIVITY # REQ REQUESTS DELAYED REQUESTS SYSTEM TOTAL -- CF LINKS -- PTH # -SERVICE TIME(MIC)- # % OF AVG TIME(MIC) NAME AVG/SEC TYPE GEN USE BUSY REQ AVG STD_DEV REQ REQ /DEL STD_DEV /ALL b XXX 3914K CBP SYNC 2903K LIST/CACHE 69K a SUBCH ASYNC LOCK CHANGED INCLUDED IN ASYNC TOTAL 71K 1.8 UNSUCC c d Request delay time : Subchannel Queuing time or Spinning time on Subchannel Service time : Link Queuing time + Link transfer time + CF CP queuing time + CF CP processing time + Time for MVS to recognize that the command has completed 9/ 51
10 CF Request 지연요소 Sync immediate Subchannel busy Sync immediate Path busy Sync non-immediate Subchannel busy Sync non-immediate Path busy Async Subchannel busy Async Path busy SW Subchannel Link Buffer CF CF CF CF CF CF Software subchannel busy 1 Sync immediate : spin/wait (HOST CPU cost 증가 ) 3 Sync non-immediate : Sync -> Async 5 Async : deferred (requeue) Link buffer busy ( 두개이상의 LAPR 가 CF link 를공유하는경우발생 ) Sync immediate : spin/wait Sync non-immediate : Sync -> Async Async : redriven (#of Req 증가 ) 10 / 51
11 PATH Busy 상태의처리 z/os V1.2 이전에는, CF 로연결되는 path 가 busy 상태일때는, sync req 는즉시 retry 되었고, async req 는 redriven 되었음 z/os V1.2 이후에는, 모든 req 들은 path busy 상태에서즉시 retry 됨 PATH BUSY retry 시간은 CF service time 에포함 PATH BUSY 는전체 REQ 의 10% 이하를유지하는것이바람직 Subchannel Tuning (OW54796) Path busy 가빈번히발생하여일정한 Threshold 값을넘기게되면, XES 가일시적으로 subchannel 을 offline 시킴 Path busy 상황을 Subchannel busy 상황으로유도 Path busy상태를 10~20% 이하로낮추려는시도 제한된 link 환경에서 link 의효과적인사용을극대화시키기위함 11 / 51
12 Heuristic Sync/Async 변환알고리즘 Long running SYNC CF request 는 sender 측의 CPU 를더많이사용함 z/os V1.2 이전에는 XES 가 LIST/CACHE SYNC request 를정해진 rule 에따라 Async 로변환하였음 Lock type 의 sync request 는예외 Request 형태 : long-running type 의 CF commands Sender 와 receiver 의프로세서형태 : Low-weighted CF partition with shared CPUs Data 의양 : 4KB 이상의 data 의전송시 z/os V1.2 이상에서는 Heuristic conversion 알고리즘적용 BEST 는아니지만 NICE or GOOD 을찾아가는알고리즘 Sync 처리의 cost 가 HOST CPU capacity 측면에큰영향을미치는것을방지하기위해 sync- >async ( 일정한 threshold 값을넘기는경우 ) 모든 CF operation 은 sync->async 의대상 구성에따라 threshold 값은달라짐 12 / 51
13 Heuristic 변환알고리즘의효과 Request rate 이많아지면, heuristic 알고리즘이개입 Heuristic 알고리즘이개입되면, response time 은증가하고 CPU cost 는일정수준으로유지됨 13 / 51
14 CF Service Time Service time 에영향을미치는요소들 Hardware speed of sender Hardware implementation of sender CFCC level Number of CF link adapter Type of link adapters Speed of the links Distance of links Request type and content (sync/async) Distribution of the CF request arrivals CF speed and number of CPs CF CPs dedicated vs. shared Availability of IOP/SAPs for async request What is the best possible response to expect Costs R64 to C to 1xx 3xx to 3xx 109 to 2xx Sync Async 가정 1) 가장빠른 CF link 사용시 2) HOST 와 CF 사이의거리를 0 으로가정 3) Well-tuned Sysplex 14 / 51
15 1. Performance on Sysplex components 1) Coupling Facility CF Service time and Delays System-Managed Duplexing CF Structure performance CFCC Level 15 Updates 2) XCF 2. Performance on Sysplex configurations 15 / 51
16 System-managed CF structure Duplexing CF exploiter에서받은 update request는각각의cf에대한두개의request로분기됨 CF to CF link상에서 signal 교환을통하여 CF의 sync상태를유지함 각각의 CF의 response는하나의response로 merge되어 exploiter에전달됨 Sync/Async type에관계없이모든 request에해당 16 / 51
17 Duplex Request 의 Response time 17 / 51
18 RMF Duplexed DB2 Lock PR WT : The amount of time that the system was holding one subchannel while waiting to get the other subchannel, to launch the duplexed operation. PR CMP : One of the two duplexed operations has completed, but the completed subchannel remains unavailable for use until the other operation completes 18 / 51
19 Costs of Duplexing z/os CPU 사용율 두개의request/response를일치시키는데드는비용 Additional pathlength is required to overlap the sending of the requests Sync request인경우, 두개의request가모두끝나기를기다려야함 CF CPU 사용율 Secondary structure를가지고있는cf의추가적인사용 CF-to-CF operation에사용되는시간 CF link 사용율 Secondary structure update를위한link의사용 CF-to-CF link의사용 CF-to-CF operation으로인해각 request의 response time이증가하고, response time의증가는 subchannel utilization을상승시킴 Costs Storage z/os CPU CF Links (time) CF CPU User Managed (DB2 GBPs) 2x 2x 2x 2x System Managed (LOCK) 2x 4x 5x 8x System Managed (LIST) 2x 3x 4x 6x 19 / 51
20 1. Performance on Sysplex components 1) Coupling Facility CF Service time and Delays System-Managed Duplexing CF Structure performance CFCC Level 15 Updates 2) XCF 2. Performance on Sysplex configurations 20 / 51
21 Coupling Facility Structures - Cache Cache structures Read/write access가가능한고속의 buffer Cached data의 coherency를보장하기위해 buffer invalidation mechanism 사용 형태 Directory only : 누가어떤 data를사용하고있는가에대해서만tracking, CF내에 data는없음 (IMS OSAM, IMS VSAM) Store-through : data가 CF와 DASD에동시에기록됨 (IMS OSAM, VSAM/RLS) Store-in : 변경된 data는 CF에쓰여지고, DASD에는일정시간후에쓰여짐 (IMS Fast Path, DB2) CPC 1 Cache Structure CONNECTION A Local Cache Vector Directory ENTRY 1 Data Entry 1 ADJ Data 1 CPC 2 CONNECTION B ENTRY m Data Entry m ADJ Data m Local Cache Vector ENTRY n Data Entry n ADJ Data n 21 / 51
22 Coupling Facility Structures - Cache 22 / 51
23 Coupling Facility Structures - List List Structures Shared work queue, shared control information LIFO/FIFO, serialized/non-serialized XCF, System logger, WebSphere MQ, DB2 SCA, JES2 Checkpoint CPC 1 CONNECTION A CONNECTION B CPC 2 CONNECTION C Serialized List Structure Lock Table m List 0 Header List 1 Header List n Header List Entry Controls Data Entry ADJ Data List Entry Controls Data Entry ADJ Data List Entry Controls ADJ Data 23 / 51
24 Coupling Facility Structures - List 24 / 51
25 Coupling Facility Structures - Lock Lock Structures 공유된 data의 serialized access를보장하기위해 shared/exclusive locking 기능제공 GRS, data sharing lock manager (IRLM, VSAM/RLS) Lock contention발생하는경우, XES에의한lock negotiation Lock table과 Record data entry로구성 CPC 1 CPC 2 Lock Structure Lock Entry x nn Excl nn Connector token Shr yyyyyyyy Resource TOM.PS1.729 TIM.PS FRANK.PS HARRY.PS dbid.psid.page# 25 / 51
26 Coupling Facility Structures - Lock 26 / 51
27 1. Performance on Sysplex components 1) Coupling Facility CF Service time and Delays System-Managed Duplexing CF Structure performance CFCC Level 15 Updates 2) XCF 2. Performance on Sysplex configurations 27 / 51
28 CFCC Level 15 Updates D CF output 과 RMF reports 에 CF 구성에관한보다자세한정보제공 RMF pp reports와 Monitor III에 structure별 CF processor 사용율제공 Concurrent CF task의수가48에서 112개로증가 Structure size의증가 System-Managed Duplexing의성능향상 CF-to-CF의교환signal 감소 28 / 51
29 CFCC Level 15 Updates 29 / 51
30 CFCC Level 15 Updates 30 / 51
31 CFCC Level 15 Updates 31 / 51
32 CFCC Level 15 Updates 32 / 51
33 CFCC Level 15 Updates Concurrent CF task 의수가 48 개에서 114 개로증가로인해 structure size 도증가하게됨 CF 내의각 structure 의일정부분은 control information 을저장하는데할당됨 더많은 task 의수는더많은 control information 을필요로함 각 structure 별로고정된양만큼의 structure size 가증가하게됨 14MB 10MB 1000 Elements/ 500 Entries 10MB 6MB 1000 Elements/ 500 Entries 6MB 1000 Elements/ 500 Entries 2MB Control Information Control Information Control Information CF level 14 CF level 15 CF level / 51
34 CFCC Level 15 Updates 34 / 51
35 CFCC Level 15 Updates 35 / 51
36 1. Performance on Sysplex components 1) Coupling Facility CF Service time and Delays System-Managed Duplexing CF Structure performance CFCC Level 15 Updates 2) XCF 2. Performance on Sysplex configurations 36 / 51
37 XCF 의성능 Transport class definition Buffer definitions Signaling paths 37 / 51
38 XCF - Overview COUPLE SYSPLEX(&SYSPLEX.) PCOUPLE(SYS1.XCFCDS.PRI) ACOUPLE(SYS1.XCFCDS.ALT) INTERVAL(85) CLEANUP(15) MAXMSG(2000) RETRY(10) CLASSDEF CLASS(DEFAULTS) CLASSLEN(956) GROUP(UNDESIG) CLASSDEF CLASS(SMALL) CLASSLEN(4028) GROUP(UNDESIG) CASSDEF CLASS(LARGE) CLASSLEN(16316) GROUP(UNDESIG) PATHOUT STRNAME(IXCSTR1) CLASS(DEFAULT) PATHOUT STRNAME(IXCSTR2) CLASS(SMALL) PATHOUT STRNAME(IXCSTR3) CLASS(LARGE) PATHOUT STRNAME(IXCSTR4) CLASS(DEFAULT) PATHIN STRNAME(IXCSTR1,IXCSTR2,IXCSTR3,IXCSTR4) 38 / 51
39 XCF Message Buffers Message Buffer 의크기 XCF는고정된 internal buffer크기를가지고있음 : 1K, 4K, 8K,,64K 실제 message 크기에가장맞는transport class를선택 Transport class에정의된것들보다큰 message는가장큰message buffer를 expand시킨후에전달 Message buffer를 expand/contract 시도를위해서는변경을위한 XCF internal signal이만들어져서교환되어야함으로 overhead가발생함 => 이를줄이기위해서 GROUP(UNDESIG) 권장 D XCF,CD,CLASS=ALL command로실제각transport class를사용하고있는 message들의실제 SIZE를 display할수있음 XCF USAGE BY SYSTEM REMOTE SYSTEMS OUTBOUND FROM XXXX BUFFER ALL TO TRANSPORT BUFFER REQ % % % % PATHS REQ SYSTEM CLASS LENGTH OUT SML FIT BIG OVR UNAVAIL REJECT XXXY DEFAULT , LONG36K 36,796 1, LONG62K 62, LONG8K 8, / 51
40 XCF Message Buffers D XCF,ClassDef,CLASS=ALL 40 / 51
41 XCF Message Buffers Message Buffer Pools MAXMSG 파라미터를이용하여 message buffer pool 에할당될수있는 virtual storage 의최대크기를설정 MAXMSG 파라미터는 COUPLE definition 에, CLASSDEF, PATHIN, PATHOUT 에정의할수있음 XCF buffer 가부족한경우에는심각한성능저하현상이발생할수있음 => buffer 의부족으로 reject 되는 message 가존재하는지반드시확인해야함 MAXMSG 의 default 값은 SETXCF command 를사용하여동적으로변경가능 41 / 51
42 XCF Signaling Paths Signaling path의종류 CF List Structure를통한연결 하나의 path가 inbound/outbound로사용가능 Mail box 방식 가장빠른 data transfer rate을가짐 모든크기의 message 전송에적합 Member의수에관계없이정의가능 Application의 SRB time이증가 CTC를통한연결 Inbound/Outbound path에대한별도의정의 Point to point 연결 작은크기의 message 전송에적합 Member의수가늘어날경우정의하기가까다로움 SAP Utilization 증가 42 / 51
43 XCF Signaling Paths Path 의수 No path 상황 XCF 는다른 transport class 를이용하여 request 를전달함 Path definition 상의문제나, physical path 의문제일가능성이큼 Path 가부족한상황 CF structure : PATHOUT link 의수가모자라면 AVG Q LENGTH 와 BUSY count 가증가함 CTC uni-directional, bi-directional 이모두가능하나성능측면을고려하면 uni-directional 을권장함 Uni-directional 구성에서는최소 4 개의 pysical CTC link 가필요함 CTC link 에서는 AVG Q LENGTH 가의미가없으며, RMF Channel activity report 를참조해야함 Channel utilization 70% 이하권장 43 / 51
44 XCF Signaling Paths Message Transfer Time Signaling path의용량이충분한지를알아볼수있는지표 2 millisecond 이하로유지 MXFER TIME의단위는 microsecond D XCF,PI,STRNM=IXCSTR1,STATUS=WORKING STRNAME REMOTE PATHIN UNUSED LAST MXFER PATHIN SYSTEM STATUS PATHS RETRY MAXMSG RECVD TIME IXCSTR1 WORKING WBA1 WORKING WBA2 WORKING WBA3 WORKING WBI1 WORKING / 51
45 XCF Tuning 목표 Transfer time을줄여라 Mean transfer time MXFER TIME in RMF Traffic을줄이기위해서는, Locking false contention을줄여라 ENQs를줄이기위해GRS star 구성 Link 사용의최적화 CTC 보다는 CF-based link사용 Transport Class buffer size Buffer가크면storage 낭비 Buffer가작으면expand를위한cost 발생 45 / 51
46 1. Performance on Sysplex components 1) Coupling Facility CF Service time and Delays System-Managed Duplexing CF Structure performance CFCC Level 15 Updates 2) XCF 2. Performance on Sysplex configurations 46 / 51
47 CF partition 구성 제 2 장 : Performance on Sysplex configurations Standalone CF Dedicated processor(s) Best for production Shared processor(s) Test 혹은 non-datasharing production Dynamic CF dispatching Competition from other partitions ICF (Internal Coupling Facility) Dedicated or shared processor(s) Optional shared processors(s) expansion Availability considerations Addressed by CF duplexing 47 / 51
48 Shared CF CP 구성 제 2 장 : Performance on Sysplex configurations PR/SM Dedicated CP Shared CP OS #2 CF #2 OS #1 프로세서 A Sync Async Async Sync Async 프로세서 B CF #1 CF #3 CF #4 Dedicated CP Shared CP PR/SM Shared CP를사용하는 CF로가는Sync req는 PR/SM에의해Async로변환된다. RMF의 CHNGED에반영되지않는다. 48 / 51
49 CF Coupling Link Performance 제 2 장 : Performance on Sysplex configurations Compatibility mode (=c*) Connect G6 and earlier Link 당 2 개의 buffer Peer mode zseries/z9 CPCs간의연결만가능 Link당 7개의 buffer Effective data rate 200MBs/s (HCD type=cfp) 500MBs/s (HCD type=cbp) 1500MBs/s (HCD type=cbp) xx (HCD type=icp) xx (HCD type=icp) 하나의 Link가 sender/receiver 역할 49 / 51
50 Coupling Technology vs. Host Processor Speed 제 2 장 : Performance on Sysplex configurations CF HOST z890 z9-bc z9-ec z10-ec z890 ISC 13% 15% 16% 21% ICB/IC 9% 10% 10% 13% z990 ISC 13% 14% 14% 19% ICB/IC 9% 9% 9% 13% z9-bc ISC 12% 13% 14% 19% CIB % ICB/IC 8% 9% 10% 12% z9-ec ISC 12% 13% 14% 18% CIB % ICB/IC 8% 8% 9% 11% z10-ec ISC 11% 12% 13% 17% CIB % ICB/IC 7% 7% 8% 10% * 9 CF ops/mips 기준 Data Sharing에소요되는HOST CPU측 cost (HOST Effect라고부름 ) CF의 processor 속도가 HOST processor 속도보다현저히느릴경우, HOST측에가해지는 cost 증가 z/os V1.2 이상에서는 heuristic algorithm에의해host Effect를 15% 정도이하로유지 CF ops/mips 계산방식 (sum of total req/sec of two CFs) (total MIPS of attached systems) 50 / 51
51 Q&A 감사합니다. 51 / 51
solution map_....
SOLUTION BROCHURE RELIABLE STORAGE SOLUTIONS ETERNUS FOR RELIABILITY AND AVAILABILITY PROTECT YOUR DATA AND SUPPORT BUSINESS FLEXIBILITY WITH FUJITSU STORAGE SOLUTIONS kr.fujitsu.com INDEX 1. Storage System
More informationThe Self-Managing Database : Automatic Health Monitoring and Alerting
The Self-Managing Database : Automatic Health Monitoring and Alerting Agenda Oracle 10g Enterpirse Manager Oracle 10g 3 rd Party PL/SQL API Summary (Self-Managing Database) ? 6% 6% 12% 55% 6% Source: IOUG
More informationPowerChute Personal Edition v3.1.0 에이전트 사용 설명서
PowerChute Personal Edition v3.1.0 990-3772D-019 4/2019 Schneider Electric IT Corporation Schneider Electric IT Corporation.. Schneider Electric IT Corporation,,,.,. Schneider Electric IT Corporation..
More informationPowerPoint 프레젠테이션
Reasons for Poor Performance Programs 60% Design 20% System 2.5% Database 17.5% Source: ORACLE Performance Tuning 1 SMS TOOL DBA Monitoring TOOL Administration TOOL Performance Insight Backup SQL TUNING
More informationPCServerMgmt7
Web Windows NT/2000 Server DP&NM Lab 1 Contents 2 Windows NT Service Provider Management Application Web UI 3 . PC,, Client/Server Network 4 (1),,, PC Mainframe PC Backbone Server TCP/IP DCS PLC Network
More information1217 WebTrafMon II
(1/28) (2/28) (10 Mbps ) Video, Audio. (3/28) 10 ~ 15 ( : telnet, ftp ),, (4/28) UDP/TCP (5/28) centralized environment packet header information analysis network traffic data, capture presentation network
More informationAPOGEE Insight_KR_Base_3P11
Technical Specification Sheet Document No. 149-332P25 September, 2010 Insight 3.11 Base Workstation 그림 1. Insight Base 메인메뉴 Insight Base Insight Insight Base, Insight Base Insight Base Insight Windows
More informationuntitled
3 IBM WebSphere User Conference ESB (e-mail : ljm@kr.ibm.com) Infrastructure Solution, IGS 2005. 9.13 ESB 를통한어플리케이션통합구축 2 IT 40%. IT,,.,, (Real Time Enterprise), End to End Access Processes bounded by
More informationOracle9i Real Application Clusters
Senior Sales Consultant Oracle Corporation Oracle9i Real Application Clusters Agenda? ? (interconnect) (clusterware) Oracle9i Real Application Clusters computing is a breakthrough technology. The ability
More information6주차.key
6, Process concept A program in execution Program code PCB (process control block) Program counter, registers, etc. Stack Heap Data section => global variable Process in memory Process state New Running
More information歯CRM개괄_허순영.PDF
CRM 2000. 8. KAIST CRM CRM CRM CRM :,, KAIST : 50%-60%, 20% 60%-80%. AMR Research 10.. CRM. 5. Harvard Business review 60%, 13%. Michaelson & Associates KAIST CRM? ( ),,, -,,, CRM needs,,, dynamically
More information세션 3 (오이식).ppt
05. 7. 21 1. EAI 2. EAI Architecture 3. EAI 4. Copyright 2005 MOCOCO, Inc.. All rights reserved. Copyright 2005 MOCOCO, Inc.. All rights reserved. ntents EAI 1 EAI EAI EAI EAI EAI EAI EAI Copyright 2005
More informationecorp-프로젝트제안서작성실무(양식3)
(BSC: Balanced ScoreCard) ( ) (Value Chain) (Firm Infrastructure) (Support Activities) (Human Resource Management) (Technology Development) (Primary Activities) (Procurement) (Inbound (Outbound (Marketing
More informationDBPIA-NURIMEDIA
논문 10-35-03-03 한국통신학회논문지 '10-03 Vol. 35 No. 3 원활한 채널 변경을 지원하는 효율적인 IPTV 채널 관리 알고리즘 준회원 주 현 철*, 정회원 송 황 준* Effective IPTV Channel Control Algorithm Supporting Smooth Channel Zapping HyunChul Joo* Associate
More informationOPCTalk for Hitachi Ethernet 1 2. Path. DCOMwindow NT/2000 network server. Winsock update win95. . . 3 Excel CSV. Update Background Thread Client Command Queue Size Client Dynamic Scan Block Block
More informationSK IoT IoT SK IoT onem2m OIC IoT onem2m LG IoT SK IoT KAIST NCSoft Yo Studio tidev kr 5 SK IoT DMB SK IoT A M LG SDS 6 OS API 7 ios API API BaaS Backend as a Service IoT IoT ThingPlug SK IoT SK M2M M2M
More informationMAX+plus II Getting Started - 무작정따라하기
무작정 따라하기 2001 10 4 / Version 20-2 0 MAX+plus II Digital, Schematic Capture MAX+plus II, IC, CPLD FPGA (Logic) ALTERA PLD FLEX10K Series EPF10K10QC208-4 MAX+plus II Project, Schematic, Design Compilation,
More informationo o o 8.2.1. Host Error 8.2.2. Message Error 8.2.3. Recipient Error 8.2.4. Error 8.2.5. Host 8.5.1. Rule 8.5.2. Error 8.5.3. Retry Rule 8.11.1. Intermittently
More informationOracle Database 10g: Self-Managing Database DB TSC
Oracle Database 10g: Self-Managing Database DB TSC Agenda Overview System Resource Application & SQL Storage Space Backup & Recovery ½ Cost ? 6% 12 % 6% 6% 55% : IOUG 2001 DBA Survey ? 6% & 12 % 6% 6%
More informationIntro to Servlet, EJB, JSP, WS
! Introduction to J2EE (2) - EJB, Web Services J2EE iseminar.. 1544-3355 ( ) iseminar Chat. 1 Who Are We? Business Solutions Consultant Oracle Application Server 10g Business Solutions Consultant Oracle10g
More information歯A1.1함진호.ppt
The Overall Architecture of Optical Internet ETRI ? ? Payload Header Header Recognition Processing, and Generation A 1 setup 1 1 C B 2 2 2 Delay line Synchronizer New Header D - : 20Km/sec, 1µsec200 A
More informationMicrosoft PowerPoint - 3.공영DBM_최동욱_본부장-중소기업의_실용주의_CRM
中 규모 기업의 실용주의CRM 전략 (CRM for SMB) 공영DBM 솔루션컨설팅 사업부 본부장 최동욱 2007. 10. 25 Agenda I. 중소기업의 고객관리, CRM의 중요성 1. 국내외 CRM 동향 2. 고객관리, CRM의 중요성 3. CRM 도입의 기대효과 II. CRM정의 및 우리회사 적합성 1. 중소기업에 유용한 CRM의 정의 2. LTV(Life
More information목 차
Oracle 9i Admim 1. Oracle RDBMS 1.1 (System Global Area:SGA) 1.1.1 (Shared Pool) 1.1.2 (Database Buffer Cache) 1.1.3 (Redo Log Buffer) 1.1.4 Java Pool Large Pool 1.2 Program Global Area (PGA) 1.3 Oracle
More information슬라이드 1
DB2 performance Tips 2009/10/15 Hong, Mee Hee GTS. MTS., IBM Korea Performance 의의미는? Performance ( noun ) The fulfillment of a claim, promise, or request Online Response time 초당수행된 Transaction Transaction
More informationIT현황리포트 내지 완
2007 Global Information Technology Development Reports 8 9 12 13 14 15 16 18 19 20 21 24 25 26 27 28 29 32 33 34 35 36 38 39 40 41 42 43 46 47 48 49 50 51 54 55 56 57 58 60 61 62 63
More informationInteg
HP Integrity HP Chipset Itanium 2(Processor 9100) HP Integrity HP, Itanium. HP Integrity Blade BL860c HP Integrity Blade BL870c HP Integrity rx2660 HP Integrity rx3600 HP Integrity rx6600 2 HP Integrity
More informationuntitled
SAS Korea / Professional Service Division 2 3 Corporate Performance Management Definition ý... is a system that provides organizations with a method of measuring and aligning the organization strategy
More informationOrcad Capture 9.x
OrCAD Capture Workbook (Ver 10.xx) 0 Capture 1 2 3 Capture for window 4.opj ( OrCAD Project file) Design file Programe link file..dsn (OrCAD Design file) Design file..olb (OrCAD Library file) file..upd
More information금오공대 컴퓨터공학전공 강의자료
데이터베이스및설계 Chap 1. 데이터베이스환경 (#2/2) 2013.03.04. 오병우 컴퓨터공학과 Database 용어 " 데이타베이스 용어의기원 1963.6 제 1 차 SDC 심포지움 컴퓨터중심의데이타베이스개발과관리 Development and Management of a Computer-centered Data Base 자기테이프장치에저장된데이터파일을의미
More informationORANGE FOR ORACLE V4.0 INSTALLATION GUIDE (Online Upgrade) ORANGE CONFIGURATION ADMIN O
Orange for ORACLE V4.0 Installation Guide ORANGE FOR ORACLE V4.0 INSTALLATION GUIDE...1 1....2 1.1...2 1.2...2 1.2.1...2 1.2.2 (Online Upgrade)...11 1.3 ORANGE CONFIGURATION ADMIN...12 1.3.1 Orange Configuration
More informationARMBOOT 1
100% 2003222 : : : () PGPnet 1 (Sniffer) 1, 2,,, (Sniffer), (Sniffer),, (Expert) 3, (Dashboard), (Host Table), (Matrix), (ART, Application Response Time), (History), (Protocol Distribution), 1 (Select
More information2 2000. 8. 31
IT update 00 1 / 2000.8.30 IT update Information Technology 2 2000. 8. 31 C o n t e n t s 2000. 8. 31 3 4 2000. 8. 31 2000. 8. 31 5 6 2000. 8. 31 2000. 8. 31 7 8 2000. 8. 31 2000. 8. 31 9 1 0 2000. 8.
More informationMicrosoft PowerPoint - SVPSVI for LGNSYS_20120320.ppt
IBM Partner Program March, 2012 Jaemin, Lee SWG Channels, IBM Korea SWG Channels 2012 IBM Corporation Agenda IBM Korea SWG Channels Software Value Plus Software Value Incentive Revalidation 2 IBM Software
More informationthesis
( Design and Implementation of a Generalized Management Information Repository Service for Network and System Management ) ssp@nile nile.postech.ac..ac.kr DPE Lab. 1997 12 16 GMIRS GMIRS GMIRS prototype
More informationCD-RW_Advanced.PDF
HP CD-Writer Program User Guide - - Ver. 2.0 HP CD-RW Adaptec Easy CD Creator Copier, Direct CD. HP CD-RW,. Easy CD Creator 3.5C, Direct CD 3.0., HP. HP CD-RW TEAM ( 02-3270-0803 ) < > 1. CD...3 CD...5
More informationvm-웨어-01장
Chapter 16 21 (Agenda). (Green),., 2010. IT IT. IT 2007 3.1% 2030 11.1%, IT 2007 1.1.% 2030 4.7%, 2020 4 IT. 1 IT, IT. (Virtualization),. 2009 /IT 2010 10 2. 6 2008. 1970 MIT IBM (Mainframe), x86 1. (http
More information2005 2004 2003 2002 2001 2000 Security Surveillance Ubiquitous Infra Internet Infra Telematics Security Surveillance Telematics Internet Infra Solutions Camera Site (NETWORK) Monitoring & Control
More informationVoice Portal using Oracle 9i AS Wireless
Voice Portal Platform using Oracle9iAS Wireless 20020829 Oracle Technology Day 1 Contents Introduction Voice Portal Voice Web Voice XML Voice Portal Platform using Oracle9iAS Wireless Voice Portal Video
More informationSMB_ICMP_UDP(huichang).PDF
SMB(Server Message Block) UDP(User Datagram Protocol) ICMP(Internet Control Message Protocol) SMB (Server Message Block) SMB? : Microsoft IBM, Intel,. Unix NFS. SMB client/server. Client server request
More information10주차.key
10, Process synchronization (concurrently) ( ) => critical section ( ) / =>, A, B / Race condition int counter; Process A { counter++; } Process B { counter ;.. } counter++ register1 = counter register1
More information슬라이드 제목 없음
(JTC1/SC6) sjkoh@knu.ac.kr JTC1 JTC1/SC6/WG7 ECTP/RMCP/MMC (JTC1/SC6) 2/48 JTC1 ISO/IEC JTC1 Joint Technical Committee 1 ( ) ISO/TC 97 ( ) IEC/TC 83 ( ) Information Technology (IT) http://www.jtc1.org
More informationUSER GUIDE
Solution Package Volume II DATABASE MIGRATION 2010. 1. 9. U.Tu System 1 U.Tu System SeeMAGMA SYSTEM 차 례 1. INPUT & OUTPUT DATABASE LAYOUT...2 2. IPO 중 VB DATA DEFINE 자동작성...4 3. DATABASE UNLOAD...6 4.
More informationBackup Exec
(sjin.kim@veritas.com) www.veritas veritas.co..co.kr ? 24 X 7 X 365 Global Data Access.. 100% Storage Used Terabytes 9 8 7 6 5 4 3 2 1 0 2000 2001 2002 2003 IDC (TB) 93%. 199693,000 TB 2000831,000 TB.
More information<313630313032C6AFC1FD28B1C7C7F5C1DF292E687770>
양성자가속기연구센터 양성자가속기 개발 및 운영현황 DOI: 10.3938/PhiT.25.001 권혁중 김한성 Development and Operational Status of the Proton Linear Accelerator at the KOMAC Hyeok-Jung KWON and Han-Sung KIM A 100-MeV proton linear accelerator
More informationSwitching
Switching 강의의목표 Switching/Switching Network의필요성을이해한다. 세가지대표적교환기술에열거하고그차이를설명할수있다. 각교환기술의장, 단점을비교하여설명할수있다. Packet Switching 에서 Fairness 문제와 Pipelining 을 패킷크기와연계하여설명할수있다. Soft Switch 개념을이해하고설명할수있다. 교재 Chapter
More information歯sql_tuning2
SQL Tuning (2) SQL SQL SQL Tuning ROW(1) ROW(2) ROW(n) update ROW(2) at time 1 & Uncommitted update ROW(2) at time 2 SQLDBA> @ UTLLOCKT WAITING_SESSION TYPE MODE_REQUESTED MODE_HELD LOCK_ID1
More informationNetwork seminar.key
Intro to Network .. 2 4 ( ) ( ). ?!? ~! This is ~ ( ) /,,,???? TCP/IP Application Layer Transfer Layer Internet Layer Data Link Layer Physical Layer OSI 7 TCP/IP Application Layer Transfer Layer 3 4 Network
More information02이승민선생_오라클.PDF
Oracle Internet Procurement Agenda 1 2 3 4 5 Introduction Oracle Solution Overview Oracle Internet Procurement Value Proposition Reference Conclusion e-procurement, E- Commerce Internet Automated Transactions
More informationPRO1_16E [읽기 전용]
MPI PG 720 Siemens AG 1999 All rights reserved File: PRO1_16E1 Information and MPI 2 MPI 3 : 4 GD 5 : 6 : 7 GD 8 GD 9 GD 10 GD 11 : 12 : 13 : 14 SFC 60 SFC 61 15 NETPRO 16 SIMATIC 17 S7 18 1 MPI MPI S7-300
More information제20회_해킹방지워크샵_(이재석)
IoT DDoS DNS (jaeseog@sherpain.net) (www.sherpain.net) DDoS DNS DDoS / DDoS(Distributed DoS)? B Asia Broadband B Bots connect to a C&C to create an overlay network (botnet) C&C Provider JP Corp. Bye Bye!
More information001지식백서_4도
White Paper on Knowledge Service Industry Message Message Contents Contents Contents Contents Chapter 1 Part 1. Part 2. Part 3. Chapter
More informationChap06(Interprocess Communication).PDF
Interprocess Communication 2002 2 Hyun-Ju Park Introduction (interprocess communication; IPC) IPC data transfer sharing data event notification resource sharing process control Interprocess Communication
More information# Old State Mew State Trigger Actions 1 - TCP/IP NOT CONNECTED Initialization 2 TCP/IP NOT HSMS NOT TCP/IP Connect Succeeds: CONNECTED SELECTED 1. TCP/IP "accecpt" succeeds. Start T7 timeout 1. Cancel
More informationMicrosoft PowerPoint - eSlim SV5-2510 [080116]
Innovation for Total Solution Provider!! eslim SV5-2510 Opteron Server 2008. 03 ESLIM KOREA INC. 1. 제 품 개 요 eslim SV5-2510 Server Quad-Core and Dual-Core Opteron 2000 Series 6 internal HDD bays for SAS
More informationez-md+_manual01
ez-md+ HDMI/SDI Cross Converter with Audio Mux/Demux Operation manual REVISION NUMBER: 1.0.0 DISTRIBUTION DATE: NOVEMBER. 2018 저작권 알림 Copyright 2006~2018 LUMANTEK Co., Ltd. All Rights Reserved 루먼텍 사에서
More informationSRC PLUS 제어기 MANUAL
,,,, DE FIN E I N T R E A L L O C E N D SU B E N D S U B M O TIO
More informationSchoolNet튜토리얼.PDF
Interoperability :,, Reusability: : Manageability : Accessibility :, LMS Durability : (Specifications), AICC (Aviation Industry CBT Committee) : 1988, /, LMS IMS : 1997EduCom NLII,,,,, ARIADNE (Alliance
More information1. 회사소개 및 연혁 - 회사소개 회사소개 회사연혁 대표이사: 한종열 관계사 설립일 : 03. 11. 05 자본금 : 11.5억원 인 원 : 18명 에스오넷 미도리야전기코리 아 미도리야전기(일본) 2008 2007 Cisco Premier Partner 취득 Cisco Physical Security ATP 취득(진행) 서울시 강남구 도심방범CCTV관제센터
More informationIntra_DW_Ch4.PDF
The Intranet Data Warehouse Richard Tanler Ch4 : Online Analytic Processing: From Data To Information 2000. 4. 14 All rights reserved OLAP OLAP OLAP OLAP OLAP OLAP is a label, rather than a technology
More information<BCF6BDC3323030392D31385FB0EDBCD3B5B5B7CEC8DEB0D4C5B8BFEEB5B5C0D4B1B8BBF3BFACB1B85FB1C7BFB5C0CE2E687770>
... 수시연구 2009-18.. 고속도로 휴게타운 도입구상 연구 A Study on the Concept of Service Town at the Expressway Service Area... 권영인 임재경 이창운... 서 문 우리나라는 경제성장과 함께 도시화가 지속적으로 진행되어 지방 지역의 인구감소와 경기의 침체가 계속되고 있습니다. 정부의 다각 적인
More informationexample code are examined in this stage The low pressure pressurizer reactor trip module of the Plant Protection System was programmed as subject for
2003 Development of the Software Generation Method using Model Driven Software Engineering Tool,,,,, Hoon-Seon Chang, Jae-Cheon Jung, Jae-Hack Kim Hee-Hwan Han, Do-Yeon Kim, Young-Woo Chang Wang Sik, Moon
More information슬라이드 1
[ CRM Fair 2004 ] CRM 1. CRM Trend 2. Customer Single View 3. Marketing Automation 4. ROI Management 5. Conclusion 1. CRM Trend 1. CRM Trend Operational CRM Analytical CRM Sales Mgt. &Prcs. Legacy System
More information1.LAN의 특징과 각종 방식
0 Chapter 1. LAN I. LAN 1. - - - - Switching - 2. LAN - (Topology) - (Cable) - - 2.1 1) / LAN - - (point to point) 2) LAN - 3) LAN - 2.2 1) Bound - - (Twisted Pair) - (Coaxial cable) - (Fiber Optics) 1
More information62
2 instance database physical storage 2 1 62 63 tablespace datafiles 2 2 64 1 2 logical view control files datafiles redo log files 65 2 3 9i OMF Oracle Managed Files, OMF 9i 9i / / OMF 9i 66 8 1MB 8 10MB
More informationthesis
CORBA TMN Surveillance System DPNM Lab, GSIT, POSTECH Email: mnd@postech.ac.kr Contents Motivation & Goal Related Work CORBA TMN Surveillance System Implementation Conclusion & Future Work 2 Motivation
More informationETL_project_best_practice1.ppt
ETL ETL Data,., Data Warehouse DataData Warehouse ETL tool/system: ETL, ETL Process Data Warehouse Platform Database, Access Method Data Source Data Operational Data Near Real-Time Data Modeling Refresh/Replication
More information리뉴얼 xtremI 최종 softcopy
SSD를 100% 이해한 CONTENTS SSD? 03 04 05 06 07 08 09 10 11 12 13 15 14 17 18 18 19 03 SSD SSD? Solid State Drive(SSD) NAND NAND DRAM SSD [ 1. SSD ] CPU( )RAM Cache Memory Firmware GB RAM Cache Memory Memory
More information김기남_ATDC2016_160620_[키노트].key
metatron Enterprise Big Data SKT Metatron/Big Data Big Data Big Data... metatron Ready to Enterprise Big Data Big Data Big Data Big Data?? Data Raw. CRM SCM MES TCO Data & Store & Processing Computational
More informationuntitled
Logistics Strategic Planning pnjlee@cjcci.or.kr Difference between 3PL and SCM Factors Third-Party Logistics Supply Chain Management Goal Demand Management End User Satisfaction Just-in-case Lower
More informationAGENDA 01 02 03 모바일 산업의 환경변화 모바일 클라우드 서비스의 등장 모바일 클라우드 서비스 융합사례
모바일 클라우드 서비스 융합사례와 시장 전망 및 신 사업전략 2011. 10 AGENDA 01 02 03 모바일 산업의 환경변화 모바일 클라우드 서비스의 등장 모바일 클라우드 서비스 융합사례 AGENDA 01. 모바일 산업의 환경 변화 가치 사슬의 분화/결합 모바일 업계에서도 PC 산업과 유사한 모듈화/분업화 진행 PC 산업 IBM à WinTel 시대 à
More informationuntitled
CAN BUS RS232 Line Ethernet CAN H/W FIFO RS232 FIFO IP ARP CAN S/W FIFO TERMINAL Emulator COMMAND Interpreter ICMP TCP UDP PROTOCOL Converter TELNET DHCP C2E SW1 CAN RS232 RJ45 Power
More informationVOL.76.2008/2 Technical SmartPlant Materials - Document Management SmartPlant Materials에서 기본적인 Document를 관리하고자 할 때 필요한 세팅, 파일 업로드 방법 그리고 Path Type인 Ph
인터그래프코리아(주)뉴스레터 통권 제76회 비매품 News Letters Information Systems for the plant Lifecycle Proccess Power & Marine Intergraph 2008 Contents Intergraph 2008 SmartPlant Materials Customer Status 인터그래프(주) 파트너사
More informationMS-SQL SERVER 대비 기능
Business! ORACLE MS - SQL ORACLE MS - SQL Clustering A-Z A-F G-L M-R S-Z T-Z Microsoft EE : Works for benchmarks only CREATE VIEW Customers AS SELECT * FROM Server1.TableOwner.Customers_33 UNION ALL SELECT
More informationchapter4
Basic Netw rk 1. ก ก ก 2. 3. ก ก 4. ก 2 1. 2. 3. 4. ก 5. ก 6. ก ก 7. ก 3 ก ก ก ก (Mainframe) ก ก ก ก (Terminal) ก ก ก ก ก ก ก ก 4 ก (Dumb Terminal) ก ก ก ก Mainframe ก CPU ก ก ก ก 5 ก ก ก ก ก ก ก ก ก ก
More information목차 BUG offline replicator 에서유효하지않은로그를읽을경우비정상종료할수있다... 3 BUG 각 partition 이서로다른 tablespace 를가지고, column type 이 CLOB 이며, 해당 table 을 truncate
ALTIBASE HDB 6.1.1.5.6 Patch Notes 목차 BUG-39240 offline replicator 에서유효하지않은로그를읽을경우비정상종료할수있다... 3 BUG-41443 각 partition 이서로다른 tablespace 를가지고, column type 이 CLOB 이며, 해당 table 을 truncate 한뒤, hash partition
More information歯4.PDF
21 WDM * OADM MUX/DEMUX EDFA Er + Doped Fiber Isolator Isolator GFF WDM Coupler 1.48 um LD 1.48 um LD Transmitter Receiver MUX EDFA OADM DEMUX Switch Fiber Optics Micro Optics Waveguide Optics Isolator,
More informationDBPIA-NURIMEDIA
무선 센서 네트워크 환경에서 링크 품질에 기반한 라우팅에 대한 효과적인 싱크홀 공격 탐지 기법 901 무선 센서 네트워크 환경에서 링크 품질에 기반한 라우팅에 대한 효과적인 싱크홀 공격 탐지 기법 (A Effective Sinkhole Attack Detection Mechanism for LQI based Routing in WSN) 최병구 조응준 (Byung
More informationMicrosoft Word - USB복사기.doc
Version: SD/USB 80130 Content Index 1. Introduction 1.1 제품개요------------------------------------------------------------P.02 1.2 모델별 제품사양-------------------------------------------------------P.04 2. Function
More informationhd1300_k_v1r2_Final_.PDF
Starter's Kit for HelloDevice 1300 Version 11 1 2 1 2 3 31 32 33 34 35 36 4 41 42 43 5 51 52 6 61 62 Appendix A (cross-over) IP 3 Starter's Kit for HelloDevice 1300 1 HelloDevice 1300 Starter's Kit HelloDevice
More informationI
I II III (C B ) (C L ) (HL) Min c ij x ij f i y i i H j H i H s.t. y i 1, k K, i W k C B C L p (HL) x ij y i, i H, k K i, j W k x ij y i {0,1}, i, j H. K W k k H K i i f i i d ij i j r ij i j c ij r ij
More informationuntitled
Push... 2 Push... 4 Push... 5 Push... 13 Push... 15 1 FORCS Co., LTD A Leader of Enterprise e-business Solution Push (Daemon ), Push Push Observer. Push., Observer. Session. Thread Thread. Observer ID.
More information지의 절반 정도를 데이터센터 냉각, 공조 등의 설비가 사용하며 나머지 절반을 IT 장비가 사용하고 있음을 고 있으므로, 본 고에서는 JTC1/SC39에서의 그린 데 이터센터 표준화 동향을 다루도록 한다. 알 수 있다[1]. 그러므로 데이터센터 에너지 효율의 향 상을 위
표준 시험인증 기술 동향 그린 데이터센터 표준화 및 인증제 동향 정상진 ETRI 표준연구센터 미래인프라표준연구팀 선임연구원 김문구 한국IT서비스산업협회 산업진흥팀 팀장 1. 머리말 스마트 네트워크의 시대가 개막됨에 따라 급속히 증 가하는 콘텐츠의 저장, 클라우드 컴퓨팅을 포함한 다양 한 서비스의 제공 등의 목적을 위해 활용되는 데이터센 터의 수가 증가하고 있으며,
More information³»Áö¼öÁ¤
Active Directory Active Directory Active Directory Active Directory m Active Directory m Active Directory m Active Directory m Active Directory m Active Directory m Active Directory m Active
More information15_3oracle
Principal Consultant Corporate Management Team ( Oracle HRMS ) Agenda 1. Oracle Overview 2. HR Transformation 3. Oracle HRMS Initiatives 4. Oracle HRMS Model 5. Oracle HRMS System 6. Business Benefit 7.
More informationSLA QoS
SLA QoS 2002. 12. 13 Email: really97@postech.ac.kr QoS QoS SLA POS-SLMS (-Service Level Monitoring System) SLA (Service Level Agreement) SLA SLA TM Forum SLA QoS QoS SLA SLA QoS QoS SLA POS-SLMS ( Service
More informationスライド タイトルなし
2 3 회사 소개 60%출자 40%출자 주식회사 NTT데이타 아이테크 NTT DATA의 영업협력이나 첨단기술제공, 인재육성등 여러가지 지원을 통해서 SII 그룹을 대상으로 고도의 정보 서비스를 제공 함과 동시에 NTT DATA ITEC 가 보유하고 있는 높은 업무 노하우 와 SCM을 비롯한 ERP분야의 기술력을 살려서 조립가공계 및 제조업 등 새로운 시장에
More informationMicrosoft PowerPoint ppt
Wireless LAN 최양희서울대학교컴퓨터공학부 Radio-Based Wireless LANs Most widely used method Adv: penetrating walls and other obstacles with little attenuation. Disadv: security, interference, etc. 3 approaches: ISM
More information歯김병철.PDF
3G IETF byckim@mission.cnu.ac.kr kckim@konkuk.ac.kr Mobile IP WG Seamoby WG ROHC WG 3G IETF 3G IETF Mobile IP WG 3GIP Seamoby WG ROHC WG MIP WG / NAI Mobile IP / AAA IPv4 / MIP WG RFC2002bis MIPv6 INRIA
More informationSomething that can be seen, touched or otherwise sensed
Something that can be seen, touched or otherwise sensed Things about an object Weight Height Material Things an object does Pen writes Book stores words Water have Fresh water Rivers Oceans have
More informationMicrosoft Word - JAVS_UDT-1_상세_메뉴얼.doc
UDT-1 TRANSPORTER 한글 상세 제품 설명서 SoundPrime. 저작권 본 저작권은 Soundprime 이 소유하고 있습니다. Soundprime 의 허가 없이 정보 검색 시스템상에서 복사, 수정, 전달, 번역, 저장을 금지하며, 컴퓨터언어나 다른 어떠한 언어로도 수정될 수 없습니다. 또한 다른 형식이나 전기적, 기계적, 자기적, 광학적, 화학적,
More information인켈(국문)pdf.pdf
M F - 2 5 0 Portable Digital Music Player FM PRESET STEREOMONO FM FM FM FM EQ PC Install Disc MP3/FM Program U S B P C Firmware Upgrade General Repeat Mode FM Band Sleep Time Power Off Time Resume Load
More informationMulti Channel Analysis. Multi Channel Analytics :!! - (Ad network ) Report! -! -!. Valuepotion Multi Channel Analytics! (1) Install! (2) 3 (4 ~ 6 Page
Multi Channel Analysis. Multi Channel Analytics :!! - (Ad network ) Report! -! -!. Valuepotion Multi Channel Analytics! (1) Install! (2) 3 (4 ~ 6 Page ) Install!. (Ad@m, Inmobi, Google..)!. OS(Android
More information05(533-537) CPLV12-04.hwp
모바일 OS 환경의 사용자 반응성 향상 기법 533 모바일 OS 환경의 사용자 반응성 향상 기법 (Enhancing Interactivity in Mobile Operating Systems) 배선욱 김정한 (Sunwook Bae) 엄영익 (Young Ik Eom) (Junghan Kim) 요 약 사용자 반응성은 컴퓨팅 시스템에서 가장 중요 한 요소 중에 하나이고,
More informationFMX M JPG 15MB 320x240 30fps, 160Kbps 11MB View operation,, seek seek Random Access Average Read Sequential Read 12 FMX () 2
FMX FMX 20062 () wwwexellencom sales@exellencom () 1 FMX 1 11 5M JPG 15MB 320x240 30fps, 160Kbps 11MB View operation,, seek seek Random Access Average Read Sequential Read 12 FMX () 2 FMX FMX D E (one
More informationMicrosoft PowerPoint - 알고리즘_1주차_2차시.pptx
Chapter 2 Secondary Storage and System Software References: 1. M. J. Folk and B. Zoellick, File Structures, Addison-Wesley. 목차 Disks Storage as a Hierarchy Buffer Management Flash Memory 영남대학교데이터베이스연구실
More informationDIB-100_K(90x120)
Operation Manual 사용설명서 Direct Box * 본 제품을 사용하기 전에 반드시 방송방식 및 전원접압을 확인하여 사용하시기 바랍니다. MADE IN KOREA 2009. 7 124447 사용하시기 전에 사용하시기 전에 본 기기의 성능을 충분히 발휘시키기 위해 본 설명서를 처음부터 끝까지 잘 읽으시고 올바른 사용법으로 오래도록 Inter-M 제품을
More informationuntitled
15 Patterns of Creative Process Redesign J. Ray Cho Abstract Process Innovation (PI) is a fundamental rethinking and redesign of business processes to achieve improvements in critical contemporary measures
More information, N-. N- DLNA(Digital Living Network Alliance).,. DLNA DLNA. DLNA,, UPnP, IPv4, HTTP DLNA. DLNA, DLNA [1]. DLNA DLNA DLNA., [2]. DLNA UPnP. DLNA DLNA.
http://dx.doi.org/10.5909/jeb.2012.17.1.37 DLNA a), a), a) Effective Utilization of DLNA Functions in Home Media Devices Ki Cheol Kang a), Se Young Kim a), and Dae Jin Kim a) DLNA(Digital Living Network
More information05Àå
CHAPTER 05 NT,, XP,. NT NTFS, XP. D,,. XP x NT,,, ( x, x ). NT/ /XP,.. PC NT NT. + Guide to Software: Understanding and Installing Windows 2000 and Windows NT + SOFTWARE Guide to Software 3/e SOFTWARE
More information