DBPIA-NURIMEDIA



Similar documents
Microsoft PowerPoint - ISS_3rd IP_공주대학교 조정호

<30312DC1A4BAB8C5EBBDC5C7E0C1A4B9D7C1A4C3A52DC1A4BFB5C3B62E687770>

(Table of Contents) 2 (Specifications) 3 ~ 10 (Introduction) 11 (Storage Bins) 11 (Legs) 11 (Important Operating Requirements) 11 (Location Selection)

THE JOURNAL OF KOREAN INSTITUTE OF ELECTROMAGNETIC ENGINEERING AND SCIENCE Dec.; 27(12),

04_이근원_21~27.hwp

DBPIA-NURIMEDIA

???? 1

<35335FBCDBC7D1C1A42DB8E2B8AEBDBAC5CDC0C720C0FCB1E2C0FB20C6AFBCBA20BAD0BCAE2E687770>

THE JOURNAL OF KOREAN INSTITUTE OF ELECTROMAGNETIC ENGINEERING AND SCIENCE Mar.; 28(3),

THE JOURNAL OF KOREAN INSTITUTE OF ELECTROMAGNETIC ENGINEERING AND SCIENCE Nov.; 26(11),

인문사회과학기술융합학회

THE JOURNAL OF KOREAN INSTITUTE OF ELECTROMAGNETIC ENGINEERING AND SCIENCE. vol. 29, no. 10, Oct ,,. 0.5 %.., cm mm FR4 (ε r =4.4)

(specifications) 3 ~ 10 (introduction) 11 (storage bin) 11 (legs) 11 (important operating requirements) 11 (location selection) 12 (storage bin) 12 (i

DBPIA-NURIMEDIA

14.531~539(08-037).fm

<30345F D F FC0CCB5BFC8F15FB5B5B7CEC5CDB3CEC0C720B0BBB1B8BACE20B0E6B0FCBCB3B0E8B0A120C5CDB3CE20B3BBBACEC1B6B8ED2E687770>

09권오설_ok.hwp

DBPIA-NURIMEDIA

ePapyrus PDF Document

Kor. J. Aesthet. Cosmetol., 및 자아존중감과 스트레스와도 밀접한 관계가 있고, 만족 정도 에 따라 전반적인 생활에도 영향을 미치므로 신체는 갈수록 개 인적, 사회적 차원에서 중요해지고 있다(안희진, 2010). 따라서 외모만족도는 개인의 신체는 타

DBPIA-NURIMEDIA

<38305FC0B1C3A2BCB12D4D41544C41422C D756C696E6BB8A620C0CCBFEBC7D12E687770>

(JBE Vol. 21, No. 1, January 2016) (Regular Paper) 21 1, (JBE Vol. 21, No. 1, January 2016) ISSN 228

???? 1

03-서연옥.hwp

<313920C0CCB1E2BFF82E687770>

Æ÷Àå½Ã¼³94š

<352EC7E3C5C2BFB55FB1B3C5EBB5A5C0CCC5CD5FC0DABFACB0FAC7D0B4EBC7D02E687770>

DBPIA-NURIMEDIA

(JH)

- 1 -

12(4) 10.fm

10(3)-10.fm

WOMA Pumps - Z Line

878 Yu Kim, Dongjae Kim 지막 용량수준까지도 멈춤 규칙이 만족되지 않아 시행이 종료되지 않는 경우에는 MTD의 추정이 불가 능하다는 단점이 있다. 최근 이 SM방법의 단점을 보완하기 위해 O Quigley 등 (1990)이 제안한 CRM(Continu

THE JOURNAL OF KOREAN INSTITUTE OF ELECTROMAGNETIC ENGINEERING AND SCIENCE Jun.; 27(6),

3. 클라우드 컴퓨팅 상호 운용성 기반의 서비스 평가 방법론 개발.hwp

제목없음

Journal of Educational Innovation Research 2016, Vol. 26, No. 3, pp.1-16 DOI: * A Study on Good School

02 Reihe bis 750 bar GB-9.03

DBPIA-NURIMEDIA

ISO17025.PDF

대형디젤기관의 Cooled-EGR제어 시스템 개발에 관한 실험적 연구

Corporation Limited MODEL 제 품 제 원 스텐레스장축 NS_100 10A -사용압력 : 5.0 MPa -사용온도: -196 ~+60 -사용유체 : LN₂, LO₂, LAr, -사용용도 : 초저온배관, 초저온 저장탱크, 기타 50A Cryogenic

DBPIA-NURIMEDIA

<30312DC1A4BAB8C5EBBDC5C7E0C1A420B9D720C1A4C3A52DBDC5C1F82E687770>

untitled

Journal of Educational Innovation Research 2018, Vol. 28, No. 4, pp DOI: * A Research Trend

DBPIA-NURIMEDIA

08김현휘_ok.hwp

<30312DC1A4BAB8C5EBBDC5C7E0C1A4B9D7C1A4C3A528B1E8C1BEB9E8292E687770>

12.077~081(A12_이종국).fm

DBPIA-NURIMEDIA

Journal of Educational Innovation Research 2018, Vol. 28, No. 1, pp DOI: * A Analysis of

회원번호 대표자 공동자 KR000****1 권 * 영 KR000****1 박 * 순 KR000****1 박 * 애 이 * 홍 KR000****2 김 * 근 하 * 희 KR000****2 박 * 순 KR000****3 최 * 정 KR000****4 박 * 희 조 * 제

인문사회과학기술융합학회

보급형 냉동식 드라이어_FX1-21, F5-130, F25-335

THE JOURNAL OF KOREAN INSTITUTE OF ELECTROMAGNETIC ENGINEERING AND SCIENCE Mar.; 25(3),

슬라이드 제목 없음

Lumbar spine

<31362DB1E8C7FDBFF82DC0FABFB9BBEA20B5B6B8B3BFB5C8ADC0C720B1B8C0FC20B8B6C4C9C6C32E687770>

THE JOURNAL OF KOREAN INSTITUTE OF ELECTROMAGNETIC ENGINEERING AND SCIENCE Sep.; 30(9),

괘상원리에 기초한 도심재개발 경관 이원관계의 해석

Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography, Vol. 33, No. 4, , 서론. (Heo, 2013). (Park et al., 2

10(3)-09.fm

Journal of Educational Innovation Research 2018, Vol. 28, No. 1, pp DOI: A study on Characte

THE JOURNAL OF KOREAN INSTITUTE OF ELECTROMAGNETIC ENGINEERING AND SCIENCE. vol. 29, no. 6, Jun Rate). STAP(Space-Time Adaptive Processing)., -

Journal of Educational Innovation Research 2017, Vol. 27, No. 3, pp DOI: (NCS) Method of Con

DBPIA-NURIMEDIA

THE JOURNAL OF KOREAN INSTITUTE OF ELECTROMAGNETIC ENGINEERING AND SCIENCE Feb.; 29(2), IS

Analysis of objective and error source of ski technical championship Jin Su Seok 1, Seoung ki Kang 1 *, Jae Hyung Lee 1, & Won Il Son 2 1 yong in Univ

<31325FB1E8B0E6BCBA2E687770>


DBPIA-NURIMEDIA

DBPIA-NURIMEDIA

서울도시연구_13권4호.hwp

Journal of Educational Innovation Research 2018, Vol. 28, No. 3, pp DOI: * Strenghening the Cap

Journal of Educational Innovation Research 2018, Vol. 28, No. 3, pp DOI: NCS : * A Study on

<C1A4C3A5BAB8B0EDBCAD2E687770>

Journal of Educational Innovation Research 2017, Vol. 27, No. 4, pp DOI: * A Study on Teache

Journal of Educational Innovation Research 2019, Vol. 29, No. 2, pp DOI: 3 * Effects of 9th

DBPIA-NURIMEDIA

<353420B1C7B9CCB6F52DC1F5B0ADC7F6BDC7C0BB20C0CCBFEBC7D120BEC6B5BFB1B3C0B0C7C1B7CEB1D7B7A52E687770>

< C0CCC8A3BCBA2D20BFACB7E1C0FCC1F620BDBAC5C320C6F3BFAD20C8B0BFEB20C0FCB5BFBDC420C8F7C6AEC6DFC7C120BDC3BDBAC5DB2E687770>

저작자표시 - 비영리 - 변경금지 2.0 대한민국 이용자는아래의조건을따르는경우에한하여자유롭게 이저작물을복제, 배포, 전송, 전시, 공연및방송할수있습니다. 다음과같은조건을따라야합니다 : 저작자표시. 귀하는원저작자를표시하여야합니다. 비영리. 귀하는이저작물을영리목적으로이용할

Æ÷Àå82š

<303920B9DAC2F7BDC42DB3C3B8C C0C720B8F0BCBCB0FCB3BB28C7D0B0FAC8AEC0CE292E687770>

<303420C0E5C1D8BFB52DC2F8BFEBC7FC20B0B3C0CE20B3C3B9E6BDC3BDBAC5DB20B0B3B9DF2E687770>

KIM Sook Young : Lee Jungsook, a Korean Independence Activist and a Nurse during the 이며 나름 의식이 깨어있던 지식인들이라 할 수 있을 것이다. 교육을 받은 간 호부들은 환자를 돌보는 그들의 직업적 소

歯1.PDF

(2) : :, α. α (3)., (3). α α (4) (4). (3). (1) (2) Antoine. (5) (6) 80, α =181.08kPa, =47.38kPa.. Figure 1.

歯Trap관련.PDF

歯국문-Heatran소개자료1111.PDF

KC CODE KCS 국가건설기준표준시방서 Korean Construction Specification KCS : 2017 상수도공사 공기기계설비 2017 년 8 월일제정 국가건설기준

?????????????????2009-????????

I 서론 치과용 임플란트는 Brånemark 등1의 골유착 (osseointegration) 발견 이후 끊임없는 발전 을 거듭해 왔다. Brånemark 등 1 이 밝혀낸 골 유착은 임플란트의 표면과 living bone 사이에 연조직 층 의 생성이 없이 직접 골조직이

°í¼®ÁÖ Ãâ·Â

Journal of Educational Innovation Research 2018, Vol. 28, No. 4, pp DOI: * A S

Microsoft Word - 1-차우창.doc

歯coolingtower개요_1_.PDF

Transcription:

Journal of the Korean Society of Marine Engineering, Vol. 38, No. 9 pp. 1021~1026, 2014 ISSN 2234-7925 (Print) J. Korean Soc. of Marine Engineering (JKOSME) ISSN 2234-8352 (Online) http://dx.doi.org/10.5916/jkosme.2014.38.9.1021 Original Paper 운전조건 변화에 따른 hot-gas 바이패스 냉동장치의 성능 특성 백승문 1 손창효 2 허정호 3 최인수 4 윤정인 (Received August 20, 2014; Revised October 1, 2014;Accepted October 14, 2014) Performance characteristics of hot-gas bypass refrigerator with the variation of operation conditions Seung-Moon Baek 1 Chang-Hyo Son 2 Jeong-Ho Heo 3 In-Soo Choi 4 Jung-In Yoon 요약: 본 논문에서는 hot-gas를 이용한 다양한 바이패스 제어 방식 중에서 증발기 흡입부 방식에 대해 각각의 성능에 영 향을 미치는 외기온도, 출수온도, 과열 및 과냉도 등에 대해서 알아보았다. 그 주요 결과를 요약하면 다음과 같다. 우선, 증발기 흡입부로 hot-gas를 바이패스 하였을 경우에 냉동장치의 성능은 외기온도, 출수온도, 과열 및 과냉도 등에 영향을 받는 것을 알 수 있었다. 따라서 이러한 변수에 대한 최적화를 통해 본 냉동장치의 기초 설계 자료를 제공할 수 있다. 그리고 증발기 흡입부 hot-gas 바이패스 방식의 운전특성을 고찰하여 본 논문에서 제안하는 냉동장치에 대한 적용 가능 성을 확인할 수 있었다. 주제어: hot-gas 바이패스, 증기압축식 냉동기, 성능(COP), 압축일량, 냉동부하 Abstract: In this paper, among various systems applying hot-gas bypass control, outdoor temperature, outlet temperature of water cooler, superheating and subcooling degree, which are the factors affecting the performance of the system bypassing hot-gas to evaporator inlet were analyzed. The main results were summarized as following. Frist of all, performance of refrigeration system bypassing hot-gas to evaporator inlet was affected by outdoor temperature, outlet temperature of water cooler, superheating and sub cooling degree. Thus, providing basic planning date of refrigeration system obtained through optimization of variables is expectable. Thus, providing the basic design data of refrigeration system can be offered by performing the optimization of these variables. Also, the feasibility of this refrigeration system proposed in this paper was obtained by analyzing operating characteristics of the system bypassing hot-gas to evaporator inlet. Keywords: COP(coefficient of performance), Compressor work, Hot-gas bypass, Refrigeration load, Vapor compression refrigerator 1. 서 론 산업용 공작기계 분야에서는 고속가공에 의한 수축과 팽 창(열변형)을 최소화하기 위하여 오일냉동기나 수냉동기를 사용하고 있다. 오일냉동기는 공작기계 구동부(스핀들 헤드, 스크류, 기어박스, 절삭유 탱크 등)의 유압작동유나 절삭유 를 일정한 온도로 유지시켜 줌으로서 열변형을 최소화하여 가공정밀도를 향상시켜주고, 고속가공을 가능하게 해준다. 현재 주로 보급되어 사용되는 산업용 냉동기의 제어방식은 원하는 온도를 얻기 위하여 냉각 시스템의 압축기를 on-off 제어하는 방식으로, 설정 온도에 대한 2차 유체(오일/냉수) 의 편차가 ±1 내에서 제어되는 방식이지만, 실제 현장에서 의 급격한 부하 변화에 의하여 ±3~7 까지 차이가 난다. 이 것은 곧 생산품의 질 저하로 이어지게 된다. 따라서 On-off 제어하는 방식은 정밀기계인 로봇시스템,정보저장기기, 공작기계,반도체장비,전자현미경,광학장비,정밀수술 장비 3차원 측정기 등에 사용하기에는 부적합하다. 따라서 이를 보완한 제어방식으로는 압축기 출구의 고온고압 가스 를 이용하여 온도를 제어하는 hot-gas 바이패스를 조절하여 온도를 제어하는 방식이 부각되고 있다[1]. 본 연구와 관련된 산업용 공작기계용 냉동기의 온도제어 에 대한 종래의 연구를 살펴보면 다음과 같다. Lee 등[2]의 경우 hot-gas 우회 방식의 오일쿨러 성능 평가를 위해 레귤레 Corresponding Author (ORCID: http://orcid.org/0000-0002-1099-3435): Department of Refrigeration and Air Conditioning Engineering, Pukyong National University, Yongdang-dong, Nam-gu, Busan, 608-739, Korea, E-mail: yoonji@pknu.ac.kr, Tel: 051-629-6180 1 Department of Refrigeration and Air Conditioning Engineering, Pukyong National University, E-mail: hottock77@pknu.ac.kr, Tel: 051-629-6180 2 Department of Refrigeration and Air Conditioning Engineering, Pukyong National University, E-mail: sonch@pknu.ac.kr, Tel: 051-629-6180 3 Department of Refrigeration and Air Conditioning Engineering, Pukyong National University, E-mail: gjdudghl123@naver.com, Tel: 051-629-6180 4 Tongmyong University, E-mail: ischoi@tu.ac.kr, Tel: 051-629-3570 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. Copyright c The Korean Society of Marine Engineering

백승문 손창효 허정호 최인수 윤정인 이팅 밸브의 개폐에 의한 온도변화 특성과 hot-gas량을 측정 등을 통한 분석을 실시하였으며, hot-gas 바이패스를 이용하 여 오일쿨러의 성능을 평가하였고, 조절 밸브의 개폐량 및 제어를 통하여 시간에 따른 온도제어 오차를 확인하였다. Roh 등[3]은 hot-gas 바이패스 밸브를 적용한 R744용 냉 동공조장치에서 냉동부하 변화에 따라 냉매유량을 제어할 경우 냉동 사이클의 성능에 미치는 인자들을 이론적으로 파악 및 분석하였다. R744를 이용한 초임계 냉동사이클 구 동 시뮬레이션을 실시하였으나, 부하변화 및 외기온도 변 화 등에 대한 것은 제외 되었다. Yaqub 등[4]-[6]은 hot-gas 바이패스 방식에는 크게 3가지 가 있으며, 이 3가지 방식을 각각프로그램과 실험을 통해 냉 각부하 변화와 바이패스량에 다라 COP와 외부유체가 어떤 양상을 보이는지 관찰 및 분석하고 각각의 특징을 설명하고 자 하였다. 연구에서는 압축기 토출에서 팽창기 출구 측으로 바이패스하는 방법을 제시하고 있다. 하지만 제어 온도대가 저온영역으로 공작기계를 사용하는 온도대에 대한 자료가 아니며, 부분부하에 따른 성능 비교 분석에 국한되었다. 따라서 본 논문에서는 부하변화에 따른 hot-gas 바이패 스 방식별 냉동사이클의 성능 비교 에 대한 연구 결과를 바탕으로, hot-gas를 이용한 다양한 바이패스 제어 방식 중 에서 증발기 흡입부 방식에 대해 각각의 성능 특성을 외기 온도의 변화, 출구온도의 변화 등에 따른 성능 비교를 이론 적으로 규명한다. Q e y COP W h (a) Schematic diagram (4) 2. 증발기 흡입측 hot-gas 바이패스 냉동장치 및 관계식 Figure 1는 압축기 토출부의 고온고압의 냉매가스를 증발 기 입구로 바이패스 시키는 방식의 장치 개략도를 나타낸 것이며, 이 장치의 각 상태점을 P-h선도에 나타낸 것이다. 이 방식은 바이패스되는 고온 냉매를 압축기 입구로 보내는 방식이 아니기 때문에 압축기가 과열될 우려는 없다. 우선, 팽창밸브와 hot-gas 바이패스 밸브를 통해 유입되는 혼합점에서 질량과 에너지 보존식을 적용하면 다음과 같다. m total m m (1) 그리고 증발기내 냉동능력은 바이패스 유량비 (y m m total )를 이용하면 식 (2)로 정리된다. Q e m total y 또한 압축일량은 식 (3)로 정리된다. m total (2) W m total (3) 이 장치의 COP는 냉동능력 Q e 와 압축일량 W의 관계로부 터 식 (4)로 계산할 수 있다. (b) P-h diagram Figure 1: Schematics and P-h diagram of hot-gas bypass type refrigeration cycle 3. 가정 및 분석 조건 전술한 3가지 hot-gas 바이패스 방식에 사용한 냉매는 R22이며, 열역학적인 물성치와 성능분석은 HYSYS 상용 소프트웨어를 이용하였다. 그리고 hot-gas 바이패스 방식별 성능 분석을 위해 다음과 같이 가정하였다. - 열교환기내의 열 손실은 무시한다. - 배관내 압력강하와 열손실은 무시한다. - 운동에너지와 위치에너지의 변화는 고려하지 않는 것 으로 가정한다. 한국마린엔지니어링학회지 제38권 제9호(2014. 11) 1022

운전조건 변화에 따른 hot-gas 바이패스 냉동장치의 성능 특성 본 절에서는 위의 3가지 방식을 각각 적용한 냉동사이클 의 냉각부하, 외기온도, 출수온도, 과열도 조건에 따른 각 방식별 압축일량, COP, 바이패스비율 y를 구하고 이를 비 교 및 분석하고자 한다. Table 1은 3가지 방식별 사이클 특 성 파악을 위한 분석조건 및 각 방식별 성능 비교를 위한 변수들의 적용범위를 나타낸 것이다. Figure 2는 증발기흡 입측으로의 hot-gas 바이패스 방식을 각각 HYSYS 프로그 램으로 모사한 것이다. Table 1: Assumed conditions *Reference values Refrigeration load [kw] 1~3 Outdoor temperature [ ] 5, 15, 25, 35* Water temperature of evaporator 10*, 15, 20, [ ] outlet 25 Condensing temperature [ ] 45* Evaporation temperature [ ] 5* Superheating degree [ ] 0*, 5, 10 Pressure drop in heat exchanger [kpa] 0*, 10, 20, 30 Compressor efficiency [%] 70 Figure 3: Variation of compressor work with respect to outdoor temperature Figure 4: Variation of COP with respect to refrigeration load Figure 2: HYSYS diagram of hot-gas bypass type cycle III 4. 결과 및 고찰 4.1 외기 온도의 영향 Figure 3은 외기온도 변화에 따른 압축일량 변화를 나타 낸 것이다. 외기온도가 상승할수록 압축일량이 증가하는 경향을 보였다. 그 이유는 외기의 온도가 증가할수록 압축 일이 증가하는 것을 볼 수 있는데, 이는 외기온도에 따라 냉매의 응축온도가 결정되기 때문이다. 즉 외기온도가 증 가할수록 냉매의 응축온도, 응축 압력이 상승으로 인해 압 축일량이 증가하는 것을 볼 수 있다. Figure 5: Variation of bypass ratio with respect to refrigeration load 한국마린엔지니어링학회지 제38권 제9호(2014. 11) 1023

백승문 손창효 허정호 최인수 윤정인 Figure 4는 외기온도와 냉각부하 변화에 따른 COP를 나 타낸 그래프이다. 압축일량은 냉각부하에 관련 없이 일정 하므로 COP변화는 냉각부하가 증가함에 따라 증가하는 선 형적으로 증가하는 경향을 보였으며, 각 외기온도에 따라 COP 상승 기울기가 다른 경향을 보였다. 이는 동일한 냉각 부하에서 외기온도가 낮을수록 압축일량이 감소하기 때문 에 상대적으로 그 기울기가 증가하므로 외기온도가 낮을수 록 시스템의 COP는 높아짐을 보였다. 그리고 외기 온도가 35도에서 5도까지 낮아지면 COP는 273.6%, 외기 온도가 55도에서 5도까지 낮아지면 COP는 183.7%, 외기 온도가 15도에서 5도까지 낮아지면 COP는 95.6% 증가한다. Figure 5는 외기온도와 증발기 냉각부하 변화에 따른 냉 매의 바이패스율을 나타낸 그래프이다. 증발기 흡입측으로 의 hot-gas 바이패스 방식은 압축기 토출 냉매배관에서 증 발기 입구에 연결된 바이패스배관으로 유입되는 바이패스 유량이 증가할수록 필요냉각열량이 감소한다. 이는 바이패 스 유량이 증가하면 증발기 입구의 건도가 상승되며, 냉각 부하가 낮아질 경우 바이패스 비율이 높아지게 되기 때문 이다. Figure 5에서 보듯이 냉각 부하 증가 시 바이패스 비 율이 감소하는 것을 알 수 있다. 또한 각 외기온도에 따라 바이패스 비율 또한 다른데, 외기온도가 낮을수록 바이패 스 유량이 점차 커지는 경향을 보였다. 이는 외기온도는 응 축압력과 관련이 있다. 외기온도가 높은 경우는 그만큼 응 축기에서 응축시켜야 되는 냉매량이 많아야 된다. 그러므 로 응축기로 유입되는 냉매량이 많아지기 때문에 상대적으 로 바이패스관으로 유입되는 냉매량은 작아지게 되어 바이 패스율이 낮아지게 되는 것이다. 4.2 증발기 출구 수온의 영향 Figure 6은 증발기 출구 수온 변화에 따른 압축일량을 나 타낸 것이다. Figure 6에서 보듯이 증발기 출구 수온이 상승할수록 압 축일량이 감소하는데, 이는 냉매의 증발온도와 연동되는 증 발기 출구 수온이 높아지면 냉매의 증발온도가 상승하고 증 발압력 또한 상승한다. 그러므로 압축기가 응축압력까지 승 압해야 할 압력은 감소하기 때문에 압축일량은 감소한다. Figure 7은 증발기 출구 수온 변화에 따른 COP 변화를 나타낸 것이다. 냉각부하가 일정한 조건에서 압축일량은 증발기 출구 수온이 증가할수록 감소하므로 COP도 증발기 출구 수온이 증가할수록 증가한다. 각 증발기 출구 수온에 따라 COP의 증가 기울기가 다른 것을 볼 수 있는데, 이는 압축일량은 냉각부하에 영향을 받 지 않지만 증발기 출구 수온이 높을수록 감소하기 때문이다. 그러므로 COP는 압축일이 가장 큰 냉각기 출구 수온 10 부 터 가장 적은 25 까지 점차 증가하는 것을 볼 수 있다. Figure 8은 증발기 출구 수온과 증발기 냉각부하 변화에 따른 냉매의 바이패스율을 나타낸 그래프이다. 냉각부하가 증가할수록 바이패스율이 감소하는 것을 볼 수 있다. 증발 Figure 6: Variation of compressor work with respect to water temperature of evaporator outlet Figure 7: Variation of COP with respect to water temperature of evaporator outlet Figure 8: Variation of bypass ratio with respect to water temperature of evaporator outlet 한국마린엔지니어링학회지 제38권 제9호(2014. 11) 1024

운전조건 변화에 따른 hot-gas 바이패스 냉동장치의 성능 특성 기 흡입측으로의 hot-gas 바이패스 방식은 압축기 토출 냉 매배관에서 증발기 입구에 연결된 바이패스배관으로 유입 되는 바이패스 유량이 감수할수록 필요 냉각열량이 증가 한다. 이는 바이패스 유량이 감소하면 증발기 입구의 건 도가 하락하며, 냉각부하가 높아질 경우 바이패스 비율이 낮아지게 되기 때문이다. Figure 9에서 보듯이 냉각부하 증가시 바이패스율이 감소하는 것을 알 수 있다. 각 증발 기 출구 수온에 따른 바이패스율은 출수온도가 증가할수 록 증가하는 것을 알 수 있다. Figure 9: Variation of compressor work with respect to superheat degree Figure 10: Variation of COP with respect to refrigeration load Figure 11: Variation of bypass ratio with respect to refrigeration load 4.3 증발기 출구 과열도의 영향 Figure 9는 증발기 출구 과열도 증가에 따른 압축일량의 변화를 나타낸 것이다. 과열도가 증가할수록 압축일이 증 가하는 것을 알 수 있는데, 이는 과열도로 인해서 압축기 흡입 온도가 상승하고, 그 결과 P-h선도상에서 압축기 입출 구 엔탈피차가 증가하기 때문이다. Figure 10은 증발기 출구 냉매 과열도 변화에 따른 COP 의 변화를 나타낸 것이다. 냉각부하가 일정한 조건에서 압축일량은 과열도가 증가 할수록 증가하므로 COP는 과열도가 증가할수록 감소한다. 상대적으로 압축일이 가장 작은 과열도 0 가 COP가 높았 고 5, 10 순으로 COP가 높은 것을 볼 수 있다. Figure 11은 증발기 출구 냉매 과열도 변화에 따른 바이 패스비율 변화를 나타낸 것이다. 냉각부하가 증가할수록 바이패스율이 감소하는 것을 볼 수 있다. 이는 바이패스 유 량이 감소하면 증발기 입구의 건도가 하락하며, 냉각부하 가 높아질 경우 바이패스율이 낮아지게 되기 때문이다. 과 열도 0, 5, 10 사이의 바이패스율이 큰 차이를 보이지 않 는 것을 볼 수 있다. 전 냉각부하에서 비율이 전체적으로 높은 것은 과열도 10 이며 5, 0 순으로 바이패스 비율 이 낮아진다. 5. 결론 지금까지 hot-gas를 이용한 다양한 바이패스 제어 방식 중에서 증발기 흡입부 방식에 대해 각각의 성능에 영향을 미치는 외기온도, 출수온도, 과열 및 과냉도 등에 대해서 알아보았다. 그 주요 결과를 요약하면 다음과 같다. 우선, 증발기 흡입부로 hot-gas를 바이패스하여 온도를 제어하는 냉동장치의 성능은 냉매 응축압력을 결정하는 외기온도, 냉매 증발압력을 결정하는 출수온도에 순으로 가장 크게 영향을 받는다. 또한 과열 및 과냉도 등에도 영향을 받는 것을 알 수 있었지만 외기온도와 출수온도에 비해서는 영 향이 적음을 알 수 있었다. 따라서 이러한 변수에 대한 최 적화를 통해 본 냉동장치에 기초 설계 자료를 제공할 수 있을 것으로 판단된다. 그리고 증발기 흡입부 방식에 대한 hot-gas 바이패스 제어의 운전특성을 고찰하여 본 제어 방 식을 적용한 냉동장치의 대한 이해를 높임과 동시에 용도 및 목적에 따른 사용 가능성을 검토하였다. 한국마린엔지니어링학회지 제38권 제9호(2014. 11) 1025

백승문 손창효 허정호 최인수 윤정인 후 기 본 연구는 산업통상자원부가 지원하는 지역특화산업육 성사업 기술개발 결과임을 밝히며 연구비 지원에 감사드립 니다.(과제번호 : R0002687) References [1] S. M. Baek, C. G. Moon, E. P. Kim, S. K. Jeong, and J. I. Yoon, The characteristic study of capacity control of an industrial cooler using an invertor compressor with varing the ambient temperatures, The Korean Society of Marine Engineering, vol. 35, no. 2, pp. 238-243, 2011 (in Korean). [2] S. W. Lee and C.W. Lee, Assessment capability of oil cooler with Hot-gas, Korean Society for Precision Engineering, vol. 24, no. 6, pp. 459-460, 2007 (in Korean). [3] G. S. Roh and C. H. Son, Performance analysis for load control of R744 (carbon dioxide) transcritical refrigeration system using hot gas by-pass valve, Journal of the Korea Academia-Industrial Cooperation Society, vol. 10, no. 9, pp. 2189-2194, 2009 (in Korean). [4] M. Yaqub, S. M. Zubair, and S. H. Khan, Second-law-based thermodynamic analysis of Hot-gas by-pass, capacity-control schemes for refrigeration and air-conditioning systems, Energy, vol. 20, no. 6, pp. 483-493, 1995. [5] M. Yaqub and S. M. Zubair. Thermodynamic analysis of capacity-control schemes for refrigeration and air-conditioning systems, Energy, vol. 21, no. 6, pp. 463-472, 1996 [6] M. Yaqub, M, Z. Syed, and J. R. Khan, Performance evaluation of hot-gas bypass capacity control scheme for refrigeration and air-conditioning systems, Energy, vol. 25, no. 6, pp. 543-561, 2000. [7] i/marine_engineering, Accessed December 11, 2012. 한국마린엔지니어링학회지 제38권 제9호(2014. 11) 1026